Tender For Certain Repair/ Replacement Of U/S Security/ Street Lights, Mccb,S And Misc Works At Dalhousie Cantt
Tender Value
9.50 Lakhs
Estimated cost
Bid Submission
09 Jul 2026
7 days left
EMD
19000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dalhousie → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Certain Repair/ Replacement Of U/S Security/ Street Lights, Mccb,S And Misc Works At Dalhousie Cantt
BOQ
| Sl. No. | Item Description |
| 1 | M&L for taking down existing street / post lantern /Garden light fittings from pole/wall/garden any type any wattage for repair or replacement of burnt /worn out accessories and refixing in position after repair all as directed.Note :- (i) Accessories only wherever required shall be measured and paid seperately .(ii) Labour charges for taking down and repairs / refixing after repair and minor spares like wiring connection, nuts, bolts, insulation materials & cleaning of area upto one mtr around the street light pole shall be deemed to be included in the rate . |
| 2 | M&L for taking down old u/s light fittings and S & F pressure die cast aluminium housing LED street light luminaires with IP66, 70 Watt & accessories on existing bracket and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and directed. Make : Havells Cat No ENDURASUNDOWNSL70WLED765PASYBOTG or equivalent cat part of make as specified in list of make here-in-after. |
| 3 | M&L for taking down old u/s light fittings and S & F in repalcement LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66, Turbo LED series ,120Watt & accessories on existing position and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and directed. Make : Bajaj Cat ref No BARFEG120W LED or equivalent cat part of make as specified in list of make here-in-after. |
| 4 | M&L for taking down old u/s light fittings and S & F in repalcement LED floodlight luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66, Turbo LED series ,70Watt & accessories on existing position and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and directed. Make : Bajaj Cat ref No BARFEG70W LED or equivalent cat part of make as specified in list of make here-in-after. |
| 5 | S&F Digital type Time switch having sleek MCB shaped design with Front display and DIN rail mounting, power reserve for atleast 1500 hrs, operating voltage - 240 V AC, 50 Hz, working temp. upto 55 degree celcius complete with all accessories. Make - L&T Crono, CAT No. - 67DDT0 or equivalent in M/s Legrand/ABB/Havells. |
| 6 | S & F power contactor 3 pole, type ML-3, with 2 NO + 2 NC aux contacts with standard coil voltage 415 volts 5.5KW including testing connecting commissioning complete all as specified and directed.Make CE cat part No LC1D1210M7 or equivalent make of LEGRAND/ABB/L&T |
| 7 | Supply and erection of steel tubular swaged pole 410 SP 31, 9 Mtr long complete with cast iron base plate, finial Taper plug, bolts, nuts, and screws as specified type conforming to IS 2713 complete including 2 coats of aluminium paint over one coat of red oxide zinc chrome primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole including taking out old pole, complete all as specified and directed. |
| 8 | M & L for GI pipe Light grade 50 mm bore with all fittings including taking up or dwon existing pipe complete laid in trenches all as specified and directed. |
| 9 | M & L for GI pipe Light grade 40 mm bore with all fittings including taking up or dwon existing pipe complete laid in trenches all as specified and directed. |
| 10 | M&L for PCC 1:3:6 type C2 using (40 mm gradded stone aggregate) as in foundation of pole complete all as specified &directed. |
| 11 | M&L for PCC type B-1, 1:2:4 using (20 mm gradded stone aggregate) as in coping, including form work complete all as specified & directed. |
| 12 | Supply & Fixing, Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of size 2 cire 10 sqmm incl taking out cable all as specified and directed |
| 13 | All as per item no.12 here-in-before but of sze 4 core 16 Sqmm |
| 14 | All as per item no.12 here-in-before but of sze 4 core 25 Sqmm |
| 15 | All as per item no.12 here-in-before but of sze 3.5 core 35 Sqmm |
| 16 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in any type of soil complete all as specified and directed. |
| 17 | Excavation in trenches not exc 1.5 mtr wide and exc 1.5 mtr depth and getting out in any type of soil complete all as specified and directed. |
| 18 | Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed. |
| 19 | Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point all as specified and directed . |
| 20 | Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge. |
| 21 | Supply & laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed. |
| 22 | M&L for cutting road/hard standing n exc 30mm width and n exc 45cm depth and refilling alter laying of cable with excavated material and top layer with PCC (1:2:4) type B2 using 20/40 mm graded stone aggregate upto 100mm from top finish ground level all as specified and directed by Engr-in-Charge. |
| 23 | Supply & Fix in replacement bracket for street light fittings made out of 40 mm bore medium grade GI tubing 1.5 m long bent to shape and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer repair all as specified and directed. |
| 24 | Supply and connect in repair twin core PVC insulated multistranded 1100 volt grade copper conductor cable of size 2.5 sqmm single runs drawn through existing pipe |
| 25 | Taking out cable loop after necessary excavation, cutting the burnt out damage end of cable, refixing the cable providing suitable size of brass cable gland and aluminium lugs complete with all necessary connection with the existing system and refilling of excavated soil making finishing with the existing ground surface of size 4 core 16 Sqmm to 50 Sqmm |
| 26 | M & L for Preparing old surfaces of street light poles 8.5/9 mtr long and painting (exposed surfaces) with one coat of aluminium paint, including numbering and pasting reflector tape 3 differnt colour for around the pole with applying one coats of white wash painting on coping of pole complete all as specified and directed by Engineer-in-Charge. |
| 27 | S & F in repacement FRP Moulded cable looping box of size 250 mm x200 mmx115 mm complete with electrolytic aluminum bus bar suitable size capacity for 3 phase and neutral fixed on ebonite insulator and one MCB 6-16 A complete all as specified and directed. Make : SINTEX / MEW/ NATIONAL |
| 28 | M&L for taking down old u/s light fittings and Supply and fixing in position post top lantern LED type 20/25 watt 230 volt AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete |
| 29 | M&L for taking down old u/s light fittings and Supply and fix in position LED bollard 8/10 W cone type light fitting complete with all accessories and making suitable foundations incl taking down of old u/s light fittings all as specified and directed. |
| 30 | Supply and installtion in replacement Street light timer panel 3 phase maximum load capacity 6 kw capacity, Contact Rating 32 Amps TP ,MCB rating 40 Amps TPN with 24 Hours working digital timer switch outdoor type panel with canopy and locking arrangement of panel with all incoming and outgoing cable connection and complete testing all as specified and directed by Engineer in charge. Make:- Havells Cat Part No IHXTS03060 or equivalent cat part of make as specified in list of make here-in-after. |
| 31 | Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI & connected to Earthing test point and earth dolly all as shown in elect plate No 5 of SSR Pt-I incl all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 15 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc all as specified and as directed by Engr-in-charge. |
| 32 | M&L for taking down the U/S street light from pole/wall and S & F in repalcement LED Street light fitting 30/35 watt 230 V, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant includng thermal management in multiple optic complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge. |
| 33 | S & F in replacement MCCB 4 pole having thermal adustable and fixed magnetic release range 63 to 125 A and breaking capacity Icu, 25 KA at 415 V, 50 Hz, AC complete all specified all as specified and directed. |
| 34 | S & F in repacement LED driver 25 to 45 watt street light with voltage surge protector single phase 240V all as directed by Engr-in-Charge. Make - Bajaj (NEXO 35W), cat ref NEXO 42L WH PC SD PD, HALONIX Cat ref : HLSLD E2-45-CWDL-R01/ Surya CAT Ref SLDNH:25:0740:28:32:BI:A(3226) IP 66 and Cat No :SLDNH : 045: 0660: 56-66: KG:A, 45W IP 66 |
| 35 | S & F in repalcement LED driver 70 to 120 watt flood light with voltage surge protector single phase 240V all as directed by Engr-in-Charge. Make Halonix model No HLFLD-ML01-100-CWL-R/ SURYA Drive cat ref : SLDNH : 72:1150:52-56:BI:A |
| 36 | S & F in replacement LED driver 150 TO 250 watt flood light with voltage surge protector single phase 240V all as directed by Engr-in-Charge. Make Orient Elect, Model FLP 250W, Cat Ref LFSMP-250-CT-HL Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysJul 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 days