| 1 | Taking down and dismantling existing of any type street / post lantern /Garden light /flood light fittings any type any wattage for repair or replacement of burnt /worn out accessories and refixed in position after repair all as directed. Note :- (i) Labour charges for taking down and repairs / refixing after repair and minor spares like nuts, bolts , insulation materials & cleaning of area upto one mtr around the street light pole shall be deemed to be included in the rate . |
| 2 | S & F Pressure die cast aluminium housing LED street light luminaires with IP66, 70/72 Watt with PC lens & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and directed. |
| 3 | S & F LED floodlight luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66, Turbo LED series, 150Watt, Surge Protection > 5KV to 10KV & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and directed. |
| 4 | S & F LED floodlight luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66, Turbo LED series ,100Watt & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and directed. |
| 5 | S&F Digital type Time switch having sleek MCB shaped design with Front display and DIN rail mounting, power reserve for atleast 1500 hrs, operating voltage - 240 V AC, 50 Hz, working temp. upto 55 degree celcius complete with all accessories. Make - L&T Crono, CAT No. - 67DDT0 or equivalent in M/s Legrand/ABB/Havells. |
| 6 | S & F power contactor 3 pole, type ML-3, with 2 NO + 2 NC aux contacts with standard coil voltage 415 volts, Rating 40 Amp including testing connecting commissioning complete all as specified and directed. Make L & T, Siemens,Schneider, ABB or eqivalent |
| 7 | M & L for GI pipe Light grade 40 mm bore with all fittings complete laid in trenches all as specified and directed. |
| 8 | M&L for PCC 1:3:6 type C2 using (40 mm graded stone aggregate) as in foundation and coping of bollard light complete all as specified &directed. |
| 9 | M&L for PCC type B-1, 1:2:4 using (20 mm gradded stone aggregate) as in filling of road/floor cutting while laying of LT cable, including form work if required at site complete all as specified & directed. |
| 10 | Supply & Fixing, Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed armoured heavy duty cable 1100 volts grade, aluminum conductor in trenches / ducts of following sizes incl taking out cable all as specified and directed |
| 11 | (a) 2 core 10 Sqmm |
| 12 | (b) 4 core 16 Sqmm |
| 13 | (c) 3.5 core 25 Sqmm |
| 14 | (d) 3.5 core 35 Sqmm |
| 15 | (e) 3.5 Core 50 Sqmm |
| 16 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in any type soil complete all as specified and directed. |
| 17 | Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed. |
| 18 | Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point all as specified and directed . |
| 19 | Supply and laying in trench of double wall corrugated pipe of size 40 x 32mm outer and inner dia, orange colour as per IS code : 16205 (Part-24), complete all as specified and directed. |
| 20 | Supply & Fix in repair bracket for street light fittings made out of 40 mm bore medium grade GI tubing 1.5 m long bent to shape and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer repair all as specified and directed. |
| 21 | Supply and connect twin core PVC insulated multistranded 1100 volt grade copper conductor cable of size 2.5 sqmm single runs drawn through existing pipe complete all as specified and directed. |
| 22 | Taking out cable loop after necessary excavation, cutting the burnt out damage end of cable, refixing the cable providing suitable size of brass cable gland and aluminium lugs complete with all necessary connection with the existing system and refilling of excavated soil making finishing with the existing ground surface for the following sizes:- |
| 23 | (a) 4 core 16 Sqmm |
| 24 | (b) 4 core 25 Sqmm |
| 25 | (c) 3.5 core 35 Sqmm |
| 26 | (d) 3.5 core 50 Sqmm |
| 27 | M & L for Preparing old surfaces of street light poles 8.5/9 mtr long and painting (exposed surfaces) with one coat of aluminium paint, including numbering and pasting reflector tape 3 differnt colour for around the pole with applying one coats of white wash painting on coping of pole complete all as specified and directed by Engineer-in-Charge. |
| 28 | S & F FRP Moulded cable looping box of size 250 mm x200 mmx115 mm complete with electrolytic aluminum bus bar suitable size capacity for 3 phase and neutral fixed on ebonite insulator and one MCB 6-16 A complete all as specified and directed. make : SINTEX / MEW/ NATIONAL |
| 29 | Supply and fixing post top lantern LED type 20/25 watt 230 volt AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 30 | Supply and fix LED bollard cone type light fitting 20W complete with all accessories and making suitable foundations as specified and directed. |
| 31 | Supply and fixing LED Street light fitting 30/35 watt 230 V, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant includng thermal management in multiple optic complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge. |
| 32 | S & F MCCB 4 pole having thermal adustable and fixed magnetic release range 63 to 125 A and breaking capacity Icu, 16 KA at 415 V, 50 Hz, AC complete all as specified and directed. |
| 33 | S & F Changeover switch on load 100 Amps alongwith steel sheet enclosure, conforms to IEC 947 - 3, AC-23A front operated 4 pole 415V, 50 Hz, complete all as specified and directed. Please Enable Macros to View BoQ information |