Tender For Supply, Installing, Commissioning & Testing Ht 11 Kv, 3 Phase 50 Hz , Rupturing Capacity 350 Mva Indoor Type, Vcb Panel Totally Metal Clad Withdrawable Type Vacuum Circuit Breaker Including Suitable As Incomer, Including Cable Connection W

Issued by Statutory Bodies & Commissions/Committees · AGE (I) Bhalra, Jammu and Kashmir
Tender Value
75.95 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
9 days left
EMD
1.38 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
AGE (I) Bhalra → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply, Installing, Commissioning & Testing Ht 11 Kv, 3 Phase 50 Hz , Rupturing Capacity 350 Mva Indoor Type, Vcb Panel Totally Metal Clad Withdrawable Type Vacuum Circuit Breaker Including Suitable As Incomer, Including Cable Connection With Copper Busbar Of Suitable Rating. Horizontal Isolation Horizontal Drawout Type Vcb Of Capacity Minimum 800 Amps Rated Current, Iac-25Ka/0.1 Sec. The Switch Gear Panel Shall Be Made Up Of Crca Sheet Steel Duly Powder Coated Not Less Than 2.5Mm Thick For Load Bearing Section And Not Less Than 2 Mm Thickness For Non-Load Bearing And Shall Be Totally Dust And Vermin Proof. (I) Continuous Current Rating Minimum-800A. (Ii) Short Circuit Withstand Current Minimum 25 Ka For 3 Sec. (Iii) Operating Mechanism Of The Vcb Are Suitable For 10000 Mechanical Operations (Iv) Ct Ratio Should Be 400-200/5-5, Core 1: Class 1 ,15 Va Core 2: 5P10. 15Va Burden (V) Cast Resin Drawout Type Potential Transformer 11 Kv/V3/110V/V3/110V/3, 100 Va , Ci 0.5 (Vi) Protection Arrangements For The Breaker Shall Comprise Of The Following:- (A) Each Of The Incomer Switchgear Units Shall Be Provided With Over Voltage (59), Under Voltage (27). The Over Voltage Element Shall Have Setting Of 100 To 200% In Steps Of 1% And Under Voltage Element Shall Have Setting Of 30 To 90% In Steps Of 1%. Alongwith Over Current (50/51) And Earth Fault (50N/51N) Protection, The Main Protection Relays Should Be Scada Compatible With Iec 61850 Edition 2 On 2 Nos. Fo Ports. Relay Should Generate Goose Message As Per Iec 61850 Standard For Interlocking And Also Ensure Interoperability With Third Party Relays. (B) Master Trip Relay (C) Tcs Relay (Vii) The Following Meters, Indications And Acessories Are To Be Provided With The Panel. (A) Digital Volt Meter/Ammeter With Built In Selector Switch (B) Necessary Dc Supply With Powerpack, Healthy Indication Lamp & Switch. (C) Multi-Function Meter. (D) Control:- (D1) Tnc (Trip, Neutral & Close) Breaker Control Switch With Indicating Arrangement. (D2) Local/Remote Selector Switch For Breaker Open/Close Operations. Vcb Panels Should Be Manufactured, Designed & Supplied By Oem Only(Abb, Cgpisl, Siemens, Schneider). Vcb Panels From The System Houses Are Not Acceptable. All The Main Components Like Vcb/Relays/Vi/Panel Should Be Of Same Manufacturer.Vacuum Interrupter Shall Be Of Oem Make Only. Note: Altitude Of Site Is 1600M , Supply, Installing, Commissioning & Testing Ht 11 Kv, 3 Phase 50 Hz, Rupturing Capacity 350 Mva Indoor Type, Vcb Panel Totally Metal Clad Withdrawable Type Vacuum Circuit Breaker Including Suitable As Outgoing, Including Cable Connection With Copper Busbar Of Suitable Rating. Horizontal Isolation Horizontal Drawout Type Vcb Of Capacity Minimum 630 Amps Rated Current,25Ka/0.1 Sec. The Switch Gear Panel Shall Be Made Up Of Crca Sheet Steel Duly Powder Coated Not Less Than 2.5Mm Thick For Load Bearing Section And Not Less Than 2 Mm Thickness For Non-Load Bearing And Shall Be Totally Dust And Vermin Proof. (I) Continious Current Rating Minimum-630A. (Ii) Short Circuit Withstand Current Minimum 25 Ka For 3 Sec. (Iii) Operating Mechanism Of The Vcb Are Suitable For 10000 Mechanical Operations (Iv) Ct Ratio Should Be 200-100/5-5, Core 1: Class 1 ,15 Va Core 2: 5P10. 15Va Burden (V) Protection Arrangements For The Breaker Shall Comprise Of The Following:- (A) Each Of The Outgoing Switchgear Units Shall Be Provided With Over Current (50/51) And Earth Fault (50N/51N) Protection, The Main Protection Relays Should Be Scada Compatible With Iec 61850 Edition 2 On 2 Nos. Fo Ports. Relay Should Generate Goose Message As Per Iec 61850 Standard For Interlocking And Also Ensure Interoperability With Third Party Relays. (B) Master Trip Relay (C) Tcs Relay (D) Auxillary Relay(6 Elements) (Vii) The Following Meters, Indications And Acessories Are To Be Provided With The Panel. (A) Digital Ammeter With Built In Selector Switch (B) Necessary Dc Supply With Powerpack, Healthy Indication Lamp & Switch. (C) Control:- (C1) Tnc (Trip, Neutral & Close) Breaker Control Switch With Indicating Arrangement. (C2) Local/Remote Selector Switch For Breaker Open/Close Operations. Vcb Panels Should Be Manufactured, Designed & Supplied By Oem Only(Abb, Cgpisl, Siemens, Schneider). Vcb Panels From The System Houses Are Not Acceptable. All The Main Components Like Vcb/Relays/Vi/Panel Should Be Of Same Manufacturer.Vacuum Interrupter Shall Be Of Oem Make Only. Note:Altitude Of Site Is 1600M , Supply, Installing, Commissioning & Testing Ht 11 Kv, 3 Phase 50 Hz , Rupturing Capacity 350 Mva Indoor Type , Vcb Panel Totally Metal Clad Withdrawable Type Vacuum Circuit Breaker Including Suitable As Bus Coupler , Including Cable Connection With Copper Busbar Of Suitable Rating. Horizontal Isolation Horizontal Drawout Type Vcb Of Capacity Minimum 800 Amps Rated Current,25Ka/0.1 Sec . The Switch Gear Panel Shall Be Made Up Of Crca Sheet Steel Duly Powder Coated Not Less Than 2.5Mm Thick For Load Bearing Section And Not Less Than 2 Mm Thickness For Non-Load Bearing And Shall Be Totally Dust And Vermin Proof. (I) Continious Current Rating Minimum-800A. (Ii) Short Circuit Withstand Current Minimum 25 Ka For 3 Sec. (Iii) Operating Mechanism Of The Vcb Are Suitable For 10000 Mechanical Operations (Iv) Ct Ratio Should Be 400-200/5-5, Core 1: Class 1 ,15 Va Core 2: 5P10. 15Va Burden (V) Protection Arrangements For The Breaker Shall Comprise Of The Following:- (A) Each Of The Bus Coupler Switchgear Units Shall Be Provided With Over Current (50/51) And Earth Fault (50N/51N) Protection, The Main Protection Relay Should Be Scada Compatible With Iec 61850 Edition 2 On 2 Nos. Fo Ports. Relay Should Generate Goose Message As Per Iec 61850 Standard For Interlocking And Also Ensure Interoperability With Third Party Relays. (B) Master Trip Relay (C) Tcs Relay (Vi) The Following Meters, Indications And Acessories Are To Be Provided With The Panel. (A) Digital Volt Meter/Ammeter With Built In Selector Switch (B) Necessary Dc Supply With Powerpack, Healthy Indication Lamp & Switch. (C) Multi-Function Meter. (D) Control:- (D1) Tnc (Trip, Neutral & Close) Breaker Control Switch With Indicating Arrangement. (D2) Local/Remote Selector Switch For Breaker Open/Close Operations. Vcb Panels Should Be Manufactured, Designed & Supplied By Oem Only(Abb, Cgpisl, Siemens, Schneider). Vcb Panels From The System Houses Are Not Acceptable. All The Main Components Like Vcb/Relays/Vi/Panel Should Be Of Same Manufacturer.Vacuum Interrupter Shall Be Of Oem Make Only. Note: Altitude Of Site Is 1600M. , Supply And Installation Of 33 Kv Single Phase Out Door Oil Cooled Pt Of Ratio 11 Kv/Rt3/110 V/ Rt3/ 110V/ Rt3, Class 0.5-3, Burden 50 Va - 50 Va Complete With Oil Filling Etc. Complete All As Specified And Directed. , Xlpe Insulated Cable, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty)With Stranded Aluminium Conductor, 11000 Volts Grade, Of Size 3 Core 120 Sqmm Complete All As Specified And Directed. , Xlpe Insulated Cable, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty)With Stranded Aluminium Conductor, 11000 Volts Grade, Of Size 3 Core 120 Sqmm Complete All As Specified And Directed.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 02-Jul-2026 corrigendum BOQ 14-Jul-2026

BOQ

Name of Work:-
Sl. No. Item Description
1Supply, installing, Commissioning & testing HT 11 KV, 3 Phase 50 Hz , rupturing capacity 350 MVA indoor type, VCB panel totally metal clad withdrawable type Vacuum Circuit Breaker including suitable as Incomer, including cable connection with Copper busbar of suitable rating. horizontal isolation horizontal drawout type VCB of capacity minimum 800 Amps rated current, IAC-25kA/0.1 Sec. The switch gear panel shall be made up of CRCA sheet steel duly powder coated not less than 2.5mm thick for load bearing section and not less than 2 mm thickness for non-load bearing and shall be totally dust and vermin proof. (i) Continuous current rating minimum-800A.(ii) Short circuit withstand current minimum 25 KA for 3 Sec.(iii) Operating Mechanism of the VCB are suitable for 10000 Mechanical Operations (iv) CT Ratio should be 400-200/5-5, core 1: Class 1 ,15 VA Core 2: 5P10. 15VA burden(v) Cast resin drawout type potential transformer 11 KV/V3/110V/V3/110V/3, 100 VA , CI 0.5 (vi) Protection arrangements for the breaker shall comprise of the following:- (a) Each of the incomer switchgear units shall be provided with over voltage (59), under voltage (27). The over voltage element shall have setting of 100 to 200% in steps of 1% and under voltage element shall have setting of 30 to 90% in steps of 1%. Alongwith over current (50/51) and earth fault (50N/51N) protection, the main protection relays should be SCADA compatible with IEC 61850 Edition 2 on 2 nos. FO ports. Relay should generate GOOSE message as per IEC 61850 standard for interlocking and also ensure interoperability with third party relays. (b) Master Trip Relay (c) TCS Relay(vii) The following meters, indications and acessories are to be provided with the panel. (a) Digital Volt Meter/Ammeter with built in selector switch (b) Necessary DC Supply with powerpack, healthy indication lamp & switch. (c) Multi-function meter. (d) Control:- (d1) TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement. (d2) Local/remote selector switch for breaker open/close operations.VCB Panels should be Manufactured, designed & supplied by OEM only(ABB, CGPISL, SIEMENS, SCHNEIDER). VCB Panels from the System houses are not acceptable. All the main components like VCB/Relays/VI/Panel should be of same manufacturer.Vacuum interrupter shall be of OEM Make only. Note: Altitude of site is 1600M
2Supply, installing, Commissioning & testing HT 11 KV, 3 Phase 50 Hz, rupturing capacity 350 MVA indoor type, VCB panel totally metal clad withdrawable type Vacuum Circuit Breaker including suitable as Outgoing, including cable connection with Copper busbar of suitable rating. horizontal isolation horizontal drawout type VCB of capacity minimum 630 Amps rated current,25kA/0.1 Sec. The switch gear panel shall be made up of CRCA sheet steel duly powder coated not less than 2.5mm thick for load bearing section and not less than 2 mm thickness for non-load bearing and shall be totally dust and vermin proof. (i) Continious current rating minimum-630A.(ii) Short circuit withstand current minimum 25 KA for 3 Sec.(iii) Operating Mechanism of the VCB are suitable for 10000 Mechanical Operations (iv) CT Ratio should be 200-100/5-5, core 1: Class 1 ,15 VA Core 2: 5P10. 15VA burden (v) Protection arrangements for the breaker shall comprise of the following:- (a) Each of the outgoing switchgear units shall be provided with over current (50/51) and earth fault (50N/51N) protection, the main protection relays should be SCADA compatible with IEC 61850 Edition 2 on 2 nos. FO ports. Relay should generate GOOSE message as per IEC 61850 standard for interlocking and also ensure interoperability with third party relays. (b) Master Trip Relay (c) TCS Relay (d) Auxillary Relay(6 Elements)(vii) The following meters, indications and acessories are to be provided with the panel. (a) Digital Ammeter with built in selector switch (b) Necessary DC Supply with powerpack, healthy indication lamp & switch. (c) Control:- (c1) TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement. (c2) Local/remote selector switch for breaker open/close operations.VCB Panels should be Manufactured, designed & supplied by OEM only(ABB, CGPISL, SIEMENS, SCHNEIDER). VCB Panels from the System houses are not acceptable. All the main components like VCB/Relays/VI/Panel should be of same manufacturer.Vacuum interrupter shall be of OEM Make only.Note:Altitude of site is 1600M
3Supply, installing, Commissioning & testing HT 11 KV, 3 Phase 50 Hz , rupturing capacity 350 MVA indoor type , VCB panel totally metal clad withdrawable type Vacuum Circuit Breaker including suitable as Bus coupler , including cable connection with Copper busbar of suitable rating. horizontal isolation horizontal drawout type VCB of capacity minimum 800 Amps rated current,25kA/0.1 Sec . The switch gear panel shall be made up of CRCA sheet steel duly powder coated not less than 2.5mm thick for load bearing section and not less than 2 mm thickness for non-load bearing and shall be totally dust and vermin proof. (i) Continious current rating minimum-800A.(ii) Short circuit withstand current minimum 25 KA for 3 Sec.(iii) Operating Mechanism of the VCB are suitable for 10000 Mechanical Operations (iv) CT Ratio should be 400-200/5-5, core 1: Class 1 ,15 VA Core 2: 5P10. 15VA burden(v) Protection arrangements for the breaker shall comprise of the following:-(a) Each of the Bus coupler switchgear units shall be provided with over current (50/51) and earth fault (50N/51N) protection, the main protection relay should be SCADA compatible with IEC 61850 Edition 2 on 2 nos. FO ports. Relay should generate GOOSE message as per IEC 61850 standard for interlocking and also ensure interoperability with third party relays.(b) Master Trip Relay(c) TCS Relay(vi) The following meters, indications and acessories are to be provided with the panel. (a) Digital Volt Meter/Ammeter with built in selector switch (b) Necessary DC Supply with powerpack, healthy indication lamp & switch. (c) Multi-function meter. (d) Control:- (d1) TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement. (d2) Local/remote selector switch for breaker open/close operations.VCB Panels should be Manufactured, designed & supplied by OEM only(ABB, CGPISL, SIEMENS, SCHNEIDER). VCB Panels from the System houses are not acceptable. All the main components like VCB/Relays/VI/Panel should be of same manufacturer.Vacuum interrupter shall be of OEM Make only.Note: Altitude of site is 1600M.
4Supply and installation of 33 KV single phase out door oil cooled PT of ratio 11 KV/rt3/110 V/ rt3/ 110V/ rt3, Class 0.5-3, Burden 50 VA – 50 VA complete with oil filling etc. complete all as specified and directed.
5XLPE insulated cable, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sqmm complete all as specified and directed. Please Enable Macros to View BoQ information
6XLPE insulated cable, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sqmm complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56017673
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 75.95 Lakhs
LAST DATE 14-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Supply, Installing, Commissioning & Testing Ht 11 Kv, 3 Phase 50 Hz , Rupturing Capacity 350 Mva Indoor Type, Vcb Panel Totally Metal Clad Withdrawable Type Vacuum Circuit Breaker Including Suitable As Incomer, Including Cable Connection With Copper Busbar Of Suitable Rating. Horizontal Isolation Horizontal Drawout Type Vcb Of Capacity Minimum 800 Amps Rated Current, Iac-25Ka/0.1 Sec. The Switch Gear Panel Shall Be Made Up Of Crca Sheet Steel Duly Powder Coated Not Less Than 2.5Mm Thick For Load Bearing Section And Not Less Than 2 Mm Thickness For Non-Load Bearing And Shall Be Totally Dust And Vermin Proof. (I) Continuous Current Rating Minimum-800A. (Ii) Short Circuit Withstand Current Minimum 25 Ka For 3 Sec. (Iii) Operating Mechanism Of The Vcb Are Suitable For 10000 Mechanical Operations (Iv) Ct Ratio Should Be 400-200/5-5, Core 1: Class 1 ,15 Va Core 2: 5P10. 15Va Burden (V) Cast Resin Drawout Type Potential Transformer 11 Kv/V3/110V/V3/110V/3, 100 Va , Ci 0.5 (Vi) Protection Arrangements For The Breaker Shall Comprise Of The Following:- (A) Each Of The Incomer Switchgear Units Shall Be Provided With Over Voltage (59), Under Voltage (27). The Over Voltage Element Shall Have Setting Of 100 To 200% In Steps Of 1% And Under Voltage Element Shall Have Setting Of 30 To 90% In Steps Of 1%. Alongwith Over Current (50/51) And Earth Fault (50N/51N) Protection, The Main Protection Relays Should Be Scada Compatible With Iec 61850 Edition 2 On 2 Nos. Fo Ports. Relay Should Generate Goose Message As Per Iec 61850 Standard For Interlocking And Also Ensure Interoperability With Third Party Relays. (B) Master Trip Relay (C) Tcs Relay (Vii) The Following Meters, Indications And Acessories Are To Be Provided With The Panel. (A) Digital Volt Meter/Ammeter With Built In Selector Switch (B) Necessary Dc Supply With Powerpack, Healthy Indication Lamp & Switch. (C) Multi-Function Meter. (D) Control:- (D1) Tnc (Trip, Neutral & Close) Breaker Control Switch With Indicating Arrangement. (D2) Local/Remote Selector Switch For Breaker Open/Close Operations. Vcb Panels Should Be Manufactured, Designed & Supplied By Oem Only(Abb, Cgpisl, Siemens, Schneider). Vcb Panels From The System Houses Are Not Acceptable. All The Main Components Like Vcb/Relays/Vi/Panel Should Be Of Same Manufacturer.Vacuum Interrupter Shall Be Of Oem Make Only. Note: Altitude Of Site Is 1600M , Supply, Installing, Commissioning & Testing Ht 11 Kv, 3 Phase 50 Hz, Rupturing Capacity 350 Mva Indoor Type, Vcb Panel Totally Metal Clad Withdrawable Type Vacuum Circuit Breaker Including Suitable As Outgoing, Including Cable Connection With Copper Busbar Of Suitable Rating. Horizontal Isolation Horizontal Drawout Type Vcb Of Capacity Minimum 630 Amps Rated Current,25Ka/0.1 Sec. The Switch Gear Panel Shall Be Made Up Of Crca Sheet Steel Duly Powder Coated Not Less Than 2.5Mm Thick For Load Bearing Section And Not Less Than 2 Mm Thickness For Non-Load Bearing And Shall Be Totally Dust And Vermin Proof. (I) Continious Current Rating Minimum-630A. (Ii) Short Circuit Withstand Current Minimum 25 Ka For 3 Sec. (Iii) Operating Mechanism Of The Vcb Are Suitable For 10000 Mechanical Operations (Iv) Ct Ratio Should Be 200-100/5-5, Core 1: Class 1 ,15 Va Core 2: 5P10. 15Va Burden (V) Protection Arrangements For The Breaker Shall Comprise Of The Following:- (A) Each Of The Outgoing Switchgear Units Shall Be Provided With Over Current (50/51) And Earth Fault (50N/51N) Protection, The Main Protection Relays Should Be Scada Compatible With Iec 61850 Edition 2 On 2 Nos. Fo Ports. Relay Should Generate Goose Message As Per Iec 61850 Standard For Interlocking And Also Ensure Interoperability With Third Party Relays. (B) Master Trip Relay (C) Tcs Relay (D) Auxillary Relay(6 Elements) (Vii) The Following Meters, Indications And Acessories Are To Be Provided With The Panel. (A) Digital Ammeter With Built In Selector Switch (B) Necessary Dc Supply With Powerpack, Healthy Indication Lamp & Switch. (C) Control:- (C1) Tnc (Trip, Neutral & Close) Breaker Control Switch With Indicating Arrangement. (C2) Local/Remote Selector Switch For Breaker Open/Close Operations. Vcb Panels Should Be Manufactured, Designed & Supplied By Oem Only(Abb, Cgpisl, Siemens, Schneider). Vcb Panels From The System Houses Are Not Acceptable. All The Main Components Like Vcb/Relays/Vi/Panel Should Be Of Same Manufacturer.Vacuum Interrupter Shall Be Of Oem Make Only. Note:Altitude Of Site Is 1600M , Supply, Installing, Commissioning & Testing Ht 11 Kv, 3 Phase 50 Hz , Rupturing Capacity 350 Mva Indoor Type , Vcb Panel Totally Metal Clad Withdrawable Type Vacuum Circuit Breaker Including Suitable As Bus Coupler , Including Cable Connection With Copper Busbar Of Suitable Rating. Horizontal Isolation Horizontal Drawout Type Vcb Of Capacity Minimum 800 Amps Rated Current,25Ka/0.1 Sec . The Switch Gear Panel Shall Be Made Up Of Crca Sheet Steel Duly Powder Coated Not Less Than 2.5Mm Thick For Load Bearing Section And Not Less Than 2 Mm Thickness For Non-Load Bearing And Shall Be Totally Dust And Vermin Proof. (I) Continious Current Rating Minimum-800A. (Ii) Short Circuit Withstand Current Minimum 25 Ka For 3 Sec. (Iii) Operating Mechanism Of The Vcb Are Suitable For 10000 Mechanical Operations (Iv) Ct Ratio Should Be 400-200/5-5, Core 1: Class 1 ,15 Va Core 2: 5P10. 15Va Burden (V) Protection Arrangements For The Breaker Shall Comprise Of The Following:- (A) Each Of The Bus Coupler Switchgear Units Shall Be Provided With Over Current (50/51) And Earth Fault (50N/51N) Protection, The Main Protection Relay Should Be Scada Compatible With Iec 61850 Edition 2 On 2 Nos. Fo Ports. Relay Should Generate Goose Message As Per Iec 61850 Standard For Interlocking And Also Ensure Interoperability With Third Party Relays. (B) Master Trip Relay (C) Tcs Relay (Vi) The Following Meters, Indications And Acessories Are To Be Provided With The Panel. (A) Digital Volt Meter/Ammeter With Built In Selector Switch (B) Necessary Dc Supply With Powerpack, Healthy Indication Lamp & Switch. (C) Multi-Function Meter. (D) Control:- (D1) Tnc (Trip, Neutral & Close) Breaker Control Switch With Indicating Arrangement. (D2) Local/Remote Selector Switch For Breaker Open/Close Operations. Vcb Panels Should Be Manufactured, Designed & Supplied By Oem Only(Abb, Cgpisl, Siemens, Schneider). Vcb Panels From The System Houses Are Not Acceptable. All The Main Components Like Vcb/Relays/Vi/Panel Should Be Of Same Manufacturer.Vacuum Interrupter Shall Be Of Oem Make Only. Note: Altitude Of Site Is 1600M. , Supply And Installation Of 33 Kv Single Phase Out Door Oil Cooled Pt Of Ratio 11 Kv/Rt3/110 V/ Rt3/ 110V/ Rt3, Class 0.5-3, Burden 50 Va - 50 Va Complete With Oil Filling Etc. Complete All As Specified And Directed. , Xlpe Insulated Cable, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty)With Stranded Aluminium Conductor, 11000 Volts Grade, Of Size 3 Core 120 Sqmm Complete All As Specified And Directed. , Xlpe Insulated Cable, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty)With Stranded Aluminium Conductor, 11000 Volts Grade, Of Size 3 Core 120 Sqmm Complete All As Specified And Directed.
Basic Detail
Tender No CWE/NGT-32/2026-27
Bidding Type Tender
Location
City AGE (I) Bhalra
State Jammu and Kashmir
Key Dates
Publish Date 02 Jul 2026
Submission Date 14 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 75.95 Lakhs
Tender Fee 1000
EMD 1.38 Lakhs
Exemption Available
Document List
8a2bae76-08e2-4cd6-81df-d22b982b85e0.html
BOQ_865016.xls
tender32.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 9 days
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

8a2bae76-08e2-4cd6-81df-d22b982b85e0.html

xls

BOQ_865016.xls

pdf

tender32.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders