| 1 | Supply & fixing, jointing, connecting & testing in trenches XLPE/PVC insulated PVC sheathed armoured heavy duty cable 1100 volts grade, aluminum conductor in trenches / ducts of following sizes including taking out cable all as specified and directed : |
| 2 | 4 core 16 Sqmm |
| 3 | 3.5 core 25 Sqmm |
| 4 | 3.5 core 50 Sqmm |
| 5 | 3.5 core 95 Sqmm |
| 6 | 3.5 core 120 Sqmm |
| 7 | Supply and fixing of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overlall PVC sheathed in service connection size of 6 sqmm one twin core cable flat complete all as specified and directed by Engineer-in-charge. |
| 8 | Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in any type of soil including taking out faulty cable covers complete all as specified and directed. |
| 9 | Excavation in trenches not exc 1.5 mtr wide and exc 1.5 mtr depth and getting out in any type of soil complete all as specified and directed. |
| 10 | Excavation in trenches not exc 1.5 mtr wide and exc 1.5 mtr depth and getting out in Hard /dense soil complete all as specified and directed. |
| 11 | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed. |
| 12 | Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point. |
| 13 | Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge. |
| 14 | Supply & laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed. |
| 15 | M&L for High quality LT line phase separator as per REC specification suitable for 3/4 wire spacing for conductors 300 mm made out of polypropelene |
| 16 | M&L cable end terminal box outdoor type (heat shrinkable) suitable for 1.1KV 3.5 core XLPE LT cable size 70 to 120 sqmm with all jointing material, complete all as specified. |
| 17 | M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 40 mm bore of pipe including taking up or dwon existing pipe complete all as specified. |
| 18 | M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 50 mm bore of pipe including taking up or dwon existing pipe complete all as specified. |
| 19 | M & L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations ,filling and mass concrete includings necessary form work complete all as specified & directed |
| 20 | M&L for PCC type B-1, 1:2:4 using (20 mm gradded stone aggregate) as in coping, including form work complete all as specified & directed. |
| 21 | Straining only existing loose conductors / GI wire of any size complete all as and directed by Engineer-in-Charge.Note:- Distance between two poles shall be measured as a single span. |
| 22 | Material and labour for dismantling and taking down old insulators any type complete all as spd and directed. |
| 23 | M & L in replacement for shackle type, porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for 75 mm height, 90 mm dia, 1100 volts grade complete all as specified. |
| 24 | M&L for preparation of surfaces, scraping of old paint of steel tubular pole and cross arms, applying two coat of synthetic aluminium paint over a coat of red oxide primer on LT pole including three layer of reflective tape strips on around the pole after paint & numbering with writing letters of figures (block), height n'exc 10 cm and letter of figures n'exc 10 Nos with white letter under black circle for electric pole complete all as directed including preparation of surfaces of pole/ cross arms complete all as directed. |
| 25 | S&F Steel tubular swagged poles complete with GI base plate, finial taper plug, bolts, nuts and screws specified type 410 SP-31(9 mtrs long) complete with cast iron base plate, finial Taper plug, bolts, nuts, and screws as specified type conforming to IS 2713 complete including 2 coats of aluminium paint over one coat of red oxide zinc chrome primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole including taking out old pole, complete all as specified and directed. |
| 26 | Trimming of Tree branches upto 20 cm grith from the tree near LT overhead line to provide horizontal clearance of 30 cm vertical clearance of 60 cm and pole to pole distance 30 to 35 Mtr all as specified and directed by Engr-In-Charge.Note:-T & P for cutting branches an wastage removal of branches deemed to be inlcuded in the qouted rate. |
| 27 | Supply and fixing in replacement Thimble Aluminium crimping type for 16 to 25 sqmm size cable complete all as directed and specified. |
| 28 | Supply and fixing in replacement Thimble Aluminium crimping type for 50 to 120sqmm size cable complete all as directed and specified. |
| 29 | S & F in replacement of MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 63 to 125 Amps complete all as specified and directed. |
| 30 | S & F in replacement of MCCB -DPX3 200 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 200 Amps complete all as specified and directed. |
| 31 | S & F in replacement of MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 250 Amps complete all as specified and directed. |
| 32 | M&L for outdoor type factroy made bus bar chamber of size 0.75 x 0.45 x 0.40 meter depth made out of CRCA sheet 3.15mm thick with 4 Nos aluminium busbars of capacity 200 Amps, with colour code supported on incoming and outgoing under ground cables with LED R,Y,B, indicator lamp, panel having angle iron frame made of 40x40x 6 mm angle iron and 50 cms long legs embeded upto 20 cms in PCC & 30 cms clear above ground complete including painting with two coat of powder coated paint over a coat of red oxide primer on exterior and interior faces, errection of Bus Bar chamber duly grouted with PCC including earth work complete all as specified and directed by Engineer-in-Charge. |
| 33 | M&L for repair and painting to electric control panel/LT Panel/Feeder Piller box /Bus bar panel any type and any size of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and welding work as required including replacement of door hinges and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified and specified. |
| 34 | Supply and fixing in replacement miniature circuit breaker (MCB) TPN 63 Amps, 415V, 10KA 'B' curve and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge. |
| 35 | M&L for cutting road/PCC hard stand for crossing UG cable n. exc 30cm in width and n.ext 60 cm deep and refiling the same with excavated material with to layer of upto 100mm depth PCC (1:3:6) type B2 using 20/40mm graded stone aggregate after laying the cable all as specified and directed by Engr-in-Charge |
| 36 | Supply install commissioning, testing and fabrication in repacement of LT panel board outdoor type double door apoxy painted made out of 3.0mm thick CRCA sheet factory made of size not less than 1.5x1.25x0.45m duly painted floor mounted suitable for 3 phase 4 wire, 415 V, 50 HZ system , dust and vermin proof with locking arrangement including MS angle Iron panel mounting frame of suitable size made of 40x40x6mm angle and having legs min 60cm long duly painted witth two coats of black bitumenous paint over a coat of red oxide primer embeded in PCC 1:2:4 suitable for and including following accessories :- |
| 37 | (a) MCCB 250A, 35 KA, 3 Pole, 415 Volts - 01 No (For incoming) with adjustable thermal megnetic release setting)(b) MCCB 160 A, 25KA, 3 Pole, 415 Volts - 02 Nos (for outgoing) with adjustable thermal magnetic release settings)(c) MCCB 100 A, 25KA, 3 Pole, 415 Volts - 02 Nos (for outgoing) with adjustable thermal magnetic release settings)(d) MCCB 63 A, 25KA, 3 Pole, 415 Volts - 02 Nos (for outgoing) with adjustable thermal magnetic release settings)(e) Aluminium bus bar 3 phase and neutral supported on insulatores with color code of cap 400 Amp -01 Nos (set of 4 strips) inclusing digital Ammeter 0-400 Amp and Voltmer 0-500V with selector switch and phase indicator LED lamp R,Y,B-03 Nos) Please Enable Macros to View BoQ information |