| 1 | M&L for Repair to pot holes any depth, not exc 1 sqm each including sweeping free from dust and mud or water, scoring sunken surfaces in roads, paths, etc cutting around edges to at least 25mm in depth, and making good by applying tack coat @ 5 Kgs per 10 Sqm and laying premixed bituminious macadam well rammed and sealed with paving bitumen 60/70 or VG-30 grade@ 9.8 Kgs per 10 Sqm, blinded with 0.09 Cum of stone chipping of size 6.3mm and again well rolled with 8 to 10 tonne power roller (Iincluding supply of pre-mixed macadam, binder and chipping) depth of pot holes exc 30mm complete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for Preparing existing black top surface or bituminous macadam surfaces by brushing with brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc on back top/concrete surfaces than applying evenly priming tack coat with paving bitumen 60/70 or VG-30 penetration over the prepared surface by mechanical sprayer @ 5 Kgs/10 Sqm of surface area complete all as specified and directed by the Engineer -in-Charge. |
| 3 | M&L for applying bituminous premixed semi dense asphaltic concrete 40mm thick (consolidated thickness) with 5.5% binder content of paving bitumen 60/70 or VG-30 grade by weight of total mix including cement filler, on surfaces rolled & compacted with using 8 to 10 tonne capacity power roller to achieve the required compactness, camber and gradient mixed in hot mix plant using design mix and laid by mechanical paver finisher. Complete all as specified and directed by the Engineer-in-charge. |
| 4 | M&L for premixed bituminous macadam laid, rolled and compacted to required gradient and camber n.exc 75mm thickness (consolidated thickness) with 4% binder content of VG -30 by weight of total mix, mixed in hot mix plant and laid by mechnical paver finished complete. |
| 5 | M&L for preparation of existing bituminous surfaces, removing, dust, dirt grease and other foreign matters etc to receive the marking and M&L for thermo plastic (Reflective) line marking having 1.0 mm thickness (average) of uniform surface finish conforming to BS 3262 (Part 1) 1989 read in conjunction with the MOST specification 803 clause 4.2.2 on bituminous surfaces in white/yelow clour and super imposed with glass beads confirming to BS 6088 read in conjuction with and MOST specification 803 clause 4.3.3 complete all as specified and directed.Note - MOST specification 803 shall be followed strictly for execution of work & suitable machine shall be used for the marking as approved by the GE. Shape & size/ patterns of marking shall be as approved by the GE. |
| 6 | S&F in repair cat eyes/road studs for roadways sign permanent surface mounted type having tough poly carbonate micro replicated corner cube reflector lenses with a protective abrssion resistant ceramor coating having body of weather proof and impect resistant thermoplasit complete as per manufacturer,s instruction and as directed. (Colour :- Yellow/Red/Amber) Make: Series 290 of 3M or Road Star or Equivalent. |
| 7 | S&F in repair solar cat eyes/road studs size (mm) 125L x 125B x 25H including stem height 53mm approx housing dia cast aluminium (grade LM-6) fully water proof and weather proof and weatherproof coating visible distance upto 400mtr LED-6 super bright amber led (3 Nos each side) yellow charged, flush frequency 1.2 Hz-1.8Hz including solar panel 3.5V/110MA & battery one PC sub ‘C’ type Ni-Cd rechargeable battery 1.2V/2.5AH temp range 20C to 70C fixed on road for roadway sign complete as per manufacturer’s instruction and directed by Engr-in-Charge Make- 3M/Avery Dennision/Dark Eye/Green/Greenlite/Road Star Cat Part No. GSR-909 or Equivalent. |
| 8 | M&L for Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exc 400 sqm & depth exc 50 mm & n exc 100 mm. Complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L 150 MM Soling gravelled macadam or bituminous macadam surfaces in areas n exc 400 sqm and depth of n exc 50mm & n exc 100 mm complete all as specified & directed . |
| 10 | M&L for 150 mm thick water bound macadam in two layers of 75 mm each (compacted thickness), with coarse aggregate of stone (granite / trap/ basalt) of grading 2 (63 mm to 40 mm size) or of grading 3 (50 mm to 20 mm size), spread, rolled and consolidated to required gradient and camber required. Complete all as specified & directed. |
| 11 | S&F in repair plastic speed bumbs (Speed breakers) not less 400 mm wide blocks & yellow colours fixed with necessary spikes/screws to the road surface etc. Complete all as specified & directed by Engr -in - Charge. |
| 12 | S&F in repair solar cat eyes/road studs size (mm) 125L x 125B x 25H including stem height 53mm approx housing dia cast aluminium (grade LM-6) fully water proof and weather proof and weatherproof coating visible distance upto 400mtr LED-6 super bright amber led (3 Nos each side) yellow charged, flush frequency 1.2 Hz-1.8Hz including solar panel 3.5V/110MA & battery one PC sub ‘C’ type Ni-Cd rechargeable battery 1.2V/2.5AH temp range 20C to 70C fixed on road for roadway sign complete as per manufacturer’s instruction and directed by Engr-in-Charge Make- 3M/Avery Dennision/Dark Eye/Green/Greenlite/Road Star Cat Part No. GSR-909 or Equivalent. |
| 13 | S&F in repair high intensity prismatic retro - reflective (3m/Avery) sheet of colour as directed, self adhesive, fixed on steel/concrete surface etc all as specified and directed. |
| 14 | S&F in repair metal tubular dealineator made out of ABS round body fitted with 2 Nos 65mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600mm height duly powder cated and thermo plastic elastomer 3 bands of green , red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protections including embedding in PCC 1:2:4 (150x150x300 mm ) type B1 complete all as specified and directed. |
| 15 | Dismantling wrought iron or mild steel work of any description not otherwise provided for . |
| 16 | S & F of rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting and also fastening confirming to Fe – 410 – W(Gde E - 250) quality 'B' complete all as specified and directed. |
| 17 | M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc complete all as specified and directed. |
| 18 | M & L in repair 4 mm thick aluminium composite panel cladding work of choice colour incl necessary bracing for fixing to frames work or wall surface by means of reveting as directed and specified by engineer in charge. |
| 19 | S& F in repairs 12 \\" stainless steel alphabets polished fixed to ACP Panels /clading work / or metal frame work |
| 20 | S & F Plastic Kerb Stone (size 300x150x120mm) with Led lightting, high intensity, UV Protected, water proof with IP567-65 and tested as per IS 16104 standard more energy-efficient, more illuminating, including all necessary point wiring and electrical connection fixed on steel/concrete surface etc all as specified and directed. |
| 21 | M&L for Machine pressed precast PCC kerb stones of grade M-30 of size 300 mm x 150 mm x 300 mm (depth) as used in road kerbs and similar articles with plain faces, set in CM 1:4 complete all as specified and directed. |
| 22 | M&L for Machine pressed precast PCC kerb stones of grade M-30 of size 300 mm x 150 mm x 450 mm (depth) as used in road kerbs and similar articles with plain faces, set in CM 1:4 complete all as specified and directed. |
| 23 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for. Complete all as specified & directed. |
| 24 | M&L for preparing new concrete surfaces and applying Two coats of Synthetic Enamel Paint over a coat of primer complete all as specified and directed by Engr-In-Charge. |
| 25 | M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed. |
| 26 | M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 27 | S&F machine pressed precast concrete interlocking paver block any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement & pigment complete all as specified & directed. |
| 28 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 29 | S&F in repairs 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed |
| 30 | S&F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 31 | M&L for preparing old painted concrete surfaces and applying one coat of Synthetic Enamel Paint complete all as specified and directed by Engr-In-Charge. Please Enable Macros to View BoQ information |