| 1 | Demolition of brick work built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed. |
| 2 | Demolition of concrete(reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 3 | Dismantling of wrought iron or mild steel work of any description or otherwise provided for complete all as specified and directed. |
| 4 | Taking down cement plaster on wall/ceiling/roof etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed. |
| 5 | M&L 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth (without using extra cement) complete all as specified and directed. |
| 6 | Same as itme No 5 above but on other than fair faces. |
| 7 | S&F MS angle Iron as in fencing posts/angle iron and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc conforming to Fe 290 GdeE165 complete all as specified and directed. |
| 8 | S&F in repair Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised MS wire stapples or steel pins etc as directed (each line wire to be measured) complete all as specified and directed. |
| 9 | M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 10 | S & F concertina coil 600mm dia strectch and fix in stress position hot deep galvanised steel wire coated with CLR anti corrosive paints making diamond shape with the help of dove tail clips (18 SWG), the concertina coil is to be fixed with barbed wire at points where coil touched the bottom barbed wire with the help of lug rings (24 SWG) including all fittings like fastener clips, steel lug rings etc complete all as specified and directed. Note: (i) Stretch length of each coil shall be 6 mtr. (ii) weight of each coil shall not be less than 9kg. |
| 11 | M&L for applying two coat of cement base paint on plastered wall surfaces over a coat of primer incl preparation of surfaces complete all as specified and directed. |
| 12 | Boring holes 3.5m deep in soil for single under reamed piles and getting out and disposal of soil to a distance of n.exc 50m (dia of pile 300mm) complete all as specified and directed. |
| 13 | Excavation in trenches in soft/ loose soil not exc 1.5m wide and beyond 1.5m deep for foundation, pier holes etc n. exc 10 sqm on plan and getting out complete all as specified and directed. |
| 14 | M&L plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 15 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 16 | Same as item No 15 above but 5 mm dia and over up to 8 mm dia as in stirrups, spacers and binders complete all as specified and directed. |
| 17 | M&L reinforced cement concrete M-25 design mix using 20mm graded stone aggregate as in foundations, footing, foundation beams, plinth beams, bases for columns, pedestal, under reamed piles, mass concrete, etc complete all as specified and directed. |
| 18 | M&L reinforcwed cement concrete M-25 design mix using 20mm graded stone aggregate as in columns, pillars, posts, struts etc complete. |
| 19 | M&L reinforcwed cement concrete M-25 design mix using 20mm graded stone aggregate as in coping, beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 20 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surface of concrete complete. |
| 21 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions flat with rough finished surface of concrete complete all as specified and directed. |
| 22 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc on flat with rough finished surfaces of concrete complete all as specified and directed. |
| 23 | M&L for old size brick work with sub class 'B' Bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 24 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 25 | Removing excavated material exc 1.50 Km but n.exc 5 Km and depositing where directed at a level n.exc 1.5m above the staring point complete all as specified and directed. |
| 26 | M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in bedding of drain etc complete all as specified and directed. |
| 27 | M&L Brickwork with sub class `B' Bricks straight or curved on plan to any radius built in CM 1:4 complete all as specified and directed. |
| 28 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in drain benching etc. surface finished even and fair complete all as specified and directed. |
| 29 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregates) as in coping of drains including necessary formwork etc complete all as specified and directed. |
| 30 | M&L for 15mm thick cement plaster on brick surfaces of drian in cement mortar 1:4 surface finished even and smooth without using extra cement all as specified and directed. |
| 31 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc all as specified and directed. |
| 32 | M&L for pre-cast RCC slabs as in manhole covers in 1:2:4 type B1 using 20 mm graded stone aggreghate, set in cement mortar (1:4) incl use and waste of form work complete all as speciied and directed. |
| 33 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and removable old rubbishes/debries from the permises of any desciption complete all as specified and directed. |
| 34 | M & L Chequered cement concrete tiles 30cm x 30 cm x 25 mm thick , set, jointed and pointed in neat slurry in floors , with grey cement and pigments, over the layer of screed bed 15 mm thick for laying floor finishes in cement mortar 1:4 complete all as specified and directed. |
| 35 | Demolition of cement concrete under drain pipes 300mm dia SGSW,AC or (Reinforcement concrete) set in cement mortor all as directed. |
| 36 | M&L for concrete bed in PCC 1:4:8 type D2 (using 40mm graded stone aggregate) to drain pipes of 300mm dia bore including packing under and haunching against the sides of the pipes after laid & tested complete all as specified and directed. |
| 37 | S & F Reinforced Cement Concerete pipe 300mm dia class NP 3 laid and jointed with collars complete all as specified and directed. Please Enable Macros to View BoQ information |