|
| 1 | S&F in replacement of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 25 sq mm 4 core, laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed by Engineer-in-Charge.Note: Earthwork, RFR, removing of excavated soil, precast concrete cable cover, sand for cusioning of cable & GI protection pipe shall be measured and paid seperately under respective of BOQ. |
| 2 | All as per item No. 1 here-in-above, but cross sectional area 35 sq mm 3.5 core. |
| 3 | All as per item No. 1 here-in-above, but cross sectional area 50 sq mm 3.5 core. |
| 4 | All as per item No. 1 here-in-above, but cross sectional area 70 sq mm 3.5 core. |
| 5 | All as per item No. 1 here-in-above, but cross sectional area 95 sq mm 3.5 core. |
| 6 | All as per item No. 1 here-in-above, but cross sectional area 120 sq mm 3.5 core. |
| 7 | All as per item No. 1 here-in-above, but cross sectional area 185 sq mm 3.5 core. |
| 8 | Supplying and laying for GI tubing light grade including accessories for protection of cables on poles / under road crossing of sizes 80 mm bore including taking down of existing pipe, complete all as specified and directed. |
| 9 | All as per item No. 8 here-in-above, but sizes 50 mm bore |
| 10 | All as per item No. 8 here-in-above, but sizes 40 mm bore |
| 11 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in all type soil, complete all as specified and directed. |
| 12 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth upto 3.0 m for erection of poles, struts/stays, leveling of yard etc not exceeding 10 Sqm on plan and getting out in all type soil, complete all as specified and directed. |
| 13 | Supply and spreading clean, dry, fine river tibba sand for under ground electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I. |
| 14 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250 mm x 150 mm x 40 mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10 mm over underground cables for protection, complete all as specified and as directed. |
| 15 | Returning, filling in including spreading, levelling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge. |
| 16 | Removal of surplus excavated spoil not exceeding 50 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 17 | M&L for Auguring/ Driling /Boring of holes under road, pavement, hard standing by trenchless technology by mannual /machine, including fixing of GI/HDPE pipe of 100 mm bore dia, complete all as specified and directed. |
| 18 | Re-routing/relaying of existing LT cable PVC/XLPE insulated aluminium conductor armoured with glavanised steel wire complete of any size and core from any position i.e ground /wall/poles/ culverts etc complete with protection cover, sand, pipe complete all as specified and directed by Engineer-in-charge. Note:- (i) Old cable as obtained shall be re-used. (ii) Old serviceable protection cover, protection pipe and sand obtained under this item shall be reused if found serviceable.(iii) Earth work and any other new items,if required for completon of wotk shall be measured and paid separately under relavent items. |
| 19 | Material and labour for two coats of synthetic enameled paint through spray painting of outdoor type double door LT panels/feeder pillar box and replacement of unserviceable of door hinges, sliding bolts, cable entry MS sheets, cable glands, pedestal locks, bow handle and connected accessories where required by welding, cutting, drilling etc and incl fixing with MS nuts and bolts and cleaning of panels from inside and outside and removing any faulty part of cable and preparing the cable for connection with suitable Al lugs and insulating with proper colour code PVC tape whereever required and complete all as specified and directed by Engr-in-Charge. Note:- 1) Proper shut down will be taken by the authorised rep only. 2) Panel should be made vermin proof and close properly after repair. |
| 20 | Material and labour for steel structure, cross arms, bracing supports, clamps, back plates of any type, section incl. nuts, bolts, washers, welding, fabrication/bending cold or hot in any size and shape required at site complete applying of two coats of aluminum paints over a coat of red oxide primer including dismantling of existing structure complete all as directed by Engr-in-charge. |
| 21 | Material and labour for replacement of old unserviceable CT of LT Panel /Feeder pillar box with CT of ratio upto 200/5 Amps or as required at site according the load including connecting, disconnecting and testing complete all as directed at site. |
| 22 | Material and labour for replacement of old unserviceable indicator lamp any type with LED based indicating lamps of RYB colour incl disconnecting and connecting of the same all as directed at site. |
| 23 | M&L for fabrication of copper busbar iE26:E29 hot in any size and shape all as directed and including R,Y,B insulation mounted on epoxy cast/polymer glass insulators complete all as specified and directed. |
| 24 | Supply, fixing and replacement of ACB 800 Amps, 4 pole, breaking capacity 50 KA, 415 Volts, 3 Phase ,4 wire, microprocesssor release type (Icu=Ics=100%), with inbuilt memmory, and draw out type including accessories like nut bolts, lugs etc suitable setting complete all as specified and directed. |
| 25 | Supply, fixing and replacement of MCCB 630, Amps 4 pole,breaking capacity 50 KA ,415 Volts 3 Phase 4 wire, microprocesssor release type MTX1.0 (Icu=Ics=100%), Uimp=8kV including accessories like spreaders, nut bolts, lugs etc suitable setting complete all as specified and directed. |
| 26 | Supply, fixing and replacement of MCCB 400 Amps, 4 pole,breaking capacity 50 KA ,415 Volts, 3 Phase, 4 wire, microprocesssor release type MTX1.0 (Icu=Ics=100%), Uimp=8kV including accessories like spreaders, nut bolts, lugs etc suitable setting complete all as specified and directed. |
| 27 | Supply, fixing and replacement of MCCB 250 Amps 4 pole ,breaking capacity 36 KA, 415 Volts 3 Phase 4 wire,thermal magnetic adujstable release type MTX1.0 (Icu=Ics=100%), Uimp=8kV including accessories like spreaders, nut bolts, lugs etc suitable setting complete all as specified and directed. |
| 28 | Supply, fixing and replacement of MCCB160 Amps, 4 pole ,breaking capacity 36 KA, 415 Volts, 3 Phase 4 wire,thermal magnetic adujstable release type MTX1.0 (Icu=Ics=100%), Uimp=8kV including accessories like spreaders, nut, bolts, lugs etc suitable settingcomplete all as specified and directed. |
| 29 | Supply, fixing and replacement of MCB TPN 63 Amp, breaking capacity 10 KA, \\"C\\"series , 240 Volt complete all as specified and directed. |
| 30 | S&F in replacement of MCB TPN 100 Amp, breaking capacity 10 KA, \\"C\\"series , 240 Volt complete all as specified and directed. |
| 31 | M&L for end outdoor/indoor jointing kit suitable for 25 to 50 sqmm 3.5/4 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable including taking down of existing kit, complete all as specified and directed. |
| 32 | M&L for end outdoor/indoor jointing kit suitable for 70 to 95 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable & taking down of existing kit, complete all as specified and directed. |
| 33 | M&L for end outdoor/indoor jointing kit suitable for 120 to 185 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable & taking down of existing kit, complete all as specified and directed. |
| 34 | M&L for end outdoor/indoor jointing kit suitable for 240 to 300 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable & taking down of existing kit, complete all as specified and directed. |
| 35 | M& Lfor Earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip of size 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I (2009) connected to LT panel boards all as specified and directed including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1(using 20 mm graded crushed stone aggregate ) as in pit, 20mm dia GI pipe medium grade for watering pipe, 40 mm dia bore GI light grade as earth strip protection pipe, 50 mm thick pre-cast RCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate ) as in cover slab of size 300 mm x300 mm x 50mm as earth pit cover slab with & including 8 mm dia TMT bars @ 100 mm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing on completion including dismantling/taking down of old unserveciable earthing complete all as specified and directed. Note-(i) Unit rate quoted by bidder deemed to be included excavation a(ii) Rate included for excavation & earth work in any type of strata as shown in electric plate no-3 in SSR Part-I. |
| 36 | Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 600 amps duly insulated by insulation of RYB colour of suitable rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm and including of lowers on both sides including embedding the panel in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and including danger board and including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and including dismantling/taking down of old unserveciable panel with comprising of the following:- |
| 37 | (A) IN COMING |
| 38 | (a) MCCB 4 Pole, 415 Volts,breaking capacity 36 KA,400 Amp rating microprocessor release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No |
| 39 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. |
| 40 | (c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No |
| 41 | (B) OUT GOING |
| 42 | (a) MCCB 4 Pole 415 Volts 25 KA 160 Amp rating thermal adjustable release release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -02 Nos |
| 43 | (b) MCCB 4 Pole 415 Volts 25 KA 250 Amp rating thermal adjustable release release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -02 Nos |
| 44 | Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 400 amps duly insulated by insulation of RYB colour 100 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm and including of lowers on both sides including embedding the panel in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and including danger board and including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and including dismantling/taking down of old unserveciable panel with comprising of the following:- |
| 45 | (A) IN COMING |
| 46 | (a) MCCB 4 Pole ,415 Volts ,breaking capacity 36 KA, 250 Amp rating microprocessor release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No |
| 47 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. |
| 48 | (c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No |
| 49 | (B) OUT GOING |
| 50 | (a) MCCB 4 Pole ,415 Volts, breaking capacity 25 KA ,100 Amp rating thermal adjustable release release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -04 Nos |
| 51 | Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 300 amps duly insulated by insulation of RYB colour 100 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm and including of lowers on both sides including embedding the panel in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and including danger board and including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and including dismantling/taking down of old unserveciablepanel with comprising of the following:- |
| 52 | (A) IN COMING |
| 53 | (a) MCCB 4 Pole, 415 Volts, breaking capacity 25 KA, 160 Amp rating thermal adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No |
| 54 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. |
| 55 | (c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No |
| 56 | (B) OUT GOING |
| 57 | (b) MCB TPN 63 A 'C' Series Breaking capacity 10 KA -04 Nos |
| 58 | Supply, fixing, testing and commissioning as in replacement of feeder piller box, outdoor type, floor mounted, factory made CPRI approved suitable for 415 volt, 4 pole, 50 Hz, AC supply system having aluminium bus bar duly insulated by insulation of RYB and neutral colour coding 400 Amps rating mounted on porcelain insulators. The size of the panel should not be less than 600 x 500 x 350 mm and panel shall be powder coated, factory made double door made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50 mm x 50 mm x 5mm and ground clearance 600 mm minimum duly embedded in PCC (1:3:6) type C-1 platform and including wiring of multistranded copper cable of suitable size including lugs and cable gland to incoming and outgoing cables all as directed at site and including dismantling/taking down of old unserveciablepillar box with comprising of following:- |
| 59 | INCOMING:- |
| 60 | (a) MCCB TPN, 415 volts, breaking capacity 25 KA, 160 Amps - 01 No. |
| 61 | (b) RYB LED indication lamp panel mounting type (Set of three) - 01 No |
| 62 | Supply, fixing, testing and commissioning as in replacement of feeder piller box, outdoor type, floor mounted, factory made CPRI approved suitable for 415 volt, 4 pole, 50 Hz, AC supply system having aluminium bus bar duly insulated by insulation of RYB and neutral colour coding 400 Amps rating mounted on porcelain insulators. The size of the panel should not be less than 600 x 500 x 350 mm and panel shall be powder coated, factory made double door made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50 mm x 50 mm x 5mm and ground clearance 600 mm minimum duly embedded in PCC (1:3:6) type C-1 platform and including wiring of multistranded copper cable of suitable size including lugs and cable gland to incoming and outgoing cables all as directed at site and including dismantling/taking down of old unserveciable pillar box with comprising of following:- |
| 63 | INCOMING:- |
| 64 | (a) MCCB TPN, 415 volts , breaking capacity 25 KA, 125 Amps - 01 No. |
| 65 | (b) RYB LED indication lamp panel mounting type (Set of three) - 01 No |
| 66 | Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 300 amps duly insulated by insulation of RYB colour 100 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm and including of lowers on both sides including embedding the panel in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and including danger board and including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and including dismantling/taking down of old unserveciable panel with comprising of the following:- |
| 67 | (A) IN COMING |
| 68 | (a) MCCB 4 Pole, 415 Volts, breaking capacity 25 KA, 125 Amp rating thermal adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No |
| 69 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. |
| 70 | (c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No. |
| 71 | (B) OUT GOING |
| 72 | (a) MCCB 63 A, four pole ,breaking capcity 25 KA rating thermal adjustable release type -03 Nos |
| 73 | Material and labour Cement concrete (1:2:4) type B -1( using 20 mm graded crushed stone aggregate) for pedestal of poles/copping including ,fair finishing to exposed surfaces using extra cement including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed. |
| 74 | Material and labour for plain cement concrete (1:3:6), type C -2 (using 40 mm graded crushed stone aggregate ) for foundation of pole /struts/stay assembly, foundations,filling & mass concrete , foundation of pole ,struts & stay assembly etc complete all as specified and directed |
| 75 | Material and labour in replacement for prestressed cement concrete poles 9 M long of size 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10, conforming to relavent latest IS including dismantling and refixing of cross arm, security light fittings, brackets or any other existing fittings etc connecting, testing including dismantling and removal of broken pole and coping complete all as specified and directed at site. NOTE:- (i) Earthwork, PCC will be measured and paid separately under relevant item.(ii) Removal of dismantled items from site are included in rate quoted by the contractor. (iii) Manufacture's test certificate for pole shall be produced before execution work. |
| 76 | Supply and fix in replacement pin type porcelain insulator, vitreous white brown or green including one galvanised mild steel spindle two GI washer and GI Nuts 100 mm height 65 mm dia for 1100 volts grade complete all as specified and directed |
| 77 | Supply and fix in replacement shackle Type, porcelain, vitreous, white, brown or green insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel straps of size 31 x 3 mm, insulator bolt of 12 mm dia, washers and nut complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 78 | Supply and fix in replacement shackle Type, porcelain, vitreous, white, brown or green insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel straps of size 31 x 3 mm, insulator bolt of 12 mm dia, washers and nut complete all as specified and as directed. Please Enable Macros to View BoQ information |