| 1 | Taking down cement plaster on brick or PCC, stone masonry wall etc including Raking out joints, hacking for key surubbing down with water etc complete all as specified and directed. |
| 2 | M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings, colour patterns of stone chippings shall be same as adjacent existing surface and approved by Engr -in - charge in cluding taking out existing stone grit & plaster complete all as specified (Payment for providing grooves shall be made separately). |
| 3 | M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens,nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove similar to adjecent existing surface complete as per specifications and direction of the Engineer-in-charge : |
| 4 | M&L for rendering 15mm thick on external surfaces of walls etc in cement mortar 1:4 with Pidi Proof 101 LW(+) or Dr fixit or equivalent liquid water proofing admixture @ 200 ml per bag of cement finished even and smooth without using extra cement complete all as specified and directed. (Rate of Water proofing admixture shall deemed to be included under this item). Note :- The Rates are inclding Use of all scaffoldings up to 14 M ht of buildings . |
| 5 | Material and labour for rendering/plastering, 10mm to 30 mm thick as required at site in cement mortar (1:3) , for repair of RCC chajja, roof projection, fin facia , balcony railing etc including applying neat cement slurry @ 3 Kg/sqm befor rendering , finishing surface even and smooth without using extra cement as specified and directed. Note :- The Rates are inclding Use of all scaffoldings up to 14 M ht of buildings . |
| 6 | M&L for rendering 15 mm thick on internal surfaces of walls etc in cement mortar 1:6 with Pidi Proof 101 LW(+) or Dr fixit or equivalent liquid water proofing admixture @ 200 ml per bag of cement finished even and smooth without using extra cement complete all as specified and directed. (Rate of Water proofing admixture shall deemed to be included under this item). |
| 7 | M&L rendering 10 mm thick in CM (1:3) on ceiling surfaces finished even & smooth without using extra cement. |
| 8 | Material & Labour for scraping out loose mortar / concrete by chiseling / wire brushing complete and applying rust removing solution (rebaklene soulution) to exposed corroded reinforcement and applying a coat of epoxy primer (Nitozink primer from M/s Fosroc or equivalent as approved by GE) as per manufacture instructions providing and fixing of wire mesh of weight 2.5 Kg per Sqm and apply 25mm average thickness in CM (1:4) mixed with liquid integral water proofing compound (complast 'X' as per manufacture instructions) with gunitting machine at a pressure not less than 5Kg/Sqcm finally rendering 10mm thick plaster in CM 1:4 using liquid integral water proofing compound (complast 'X' 421 i.e. from M/s Fosroc and nitobound AR from M/s Fosroc or equivalent as approved by GE) in the proportion recommended by the manfacture complete all as specifed & directed.Note :- The Rates are inclding Use of all scaffoldings up to 14 M ht of buildings. |
| 9 | M&L for applying two coats of homogenious mixture super latex 302 of Dr fixit or equivalent in the ratio (1:4:7) (One part super latex, 4 part water and 7 parts of cement) @ 1.50 Kg /sqm on surface before plastering complete all as directed. |
| 10 | Dismantling wrought iron or mild steel work of any description not otherwise provided as specified and directed. |
| 11 | M&L for Framed work such as grills,gratings, etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings framework of water tanks and similar work conforming to Fe.290.Gde |
| 12 | Material & Labour for mirror polished machine cut kota stone slab all around marble strips of 50-100mm wide flooring 20-25 mm thick over 20 mm thick screed bed or bedding layer in cement sand screed in 1:6 base laid and jointed with grey cement slurry mixed with colouring pigment to match the colour or shade of kota stone slab including rubbing, polishing complete all as specified & directed.Note:- Size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced. Marble strip shall be measured and paid seperately under respective items here in before. |
| 13 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dadoand pillar laid over cement screed and jointed with 10mm thick cement backing coat in CM 1:3 complete all as specified and as directed. |
| 14 | M&L for brickwork with old clay bricks straight or curved on plain with mean radius exc 6 m built in CM1:6 incl demolition built in CM of any description including demolition of brick work complete all as specified and directed. |
| 15 | M&L for brickwork with old size clay bricks straight or curved on plian with built in half brick wall CM1:6 incl demolition built in CM of any description including demolition of brick work complete all as specified and directed. |
| 16 | Taking up or down 15 mm steel tubing and connections,including cleaning for refixing or removal to store all as specified and directed. |
| 17 | Taking up or down 20 mm steel tubing and connections,including cleaning for refixing or removal to store all as specified and directed. |
| 18 | Taking up or down 25 to 32 mm steel tubing and connections,including cleaning for refixing or removal to store all as specified and directed. |
| 19 | S&F 15 mm dia bore Medium grade GI Pipes with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed. |
| 20 | S&F 20 mm dia bore Medium grade GI Pipes with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed. |
| 21 | S&F 25 mm dia bore Medium grade GI Pipes with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed. |
| 22 | Demolition and breaking up rain water pipe (PVC , AC, or re- in forced cement concrete )of size 75 & 100 mm bore complete all as specfied and directed. |
| 23 | S&F PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to walls as specified and directed. |
| 24 | S&F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints fixed to walls as specified and directed. |
| 25 | Fixing only as in repair PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to walls as specified and directed. |
| 26 | Fixing only as in repair PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints fixed to walls as specified and directed. |
| 27 | S&F 75mm dia PVC (SWR) bend /shoe without oval access door |
| 28 | S&F 110mm dia PVC (SWR) bend with oval access door |
| 29 | S&F 110mm dia PVC (SWR) bend /shoe without oval access door |
| 30 | S&F110mm dia PVC (SWR) branch piece (single Y)equal or unequal with oval access door |
| 31 | S&F PVC (SWR) cowls 110mm dia. |
| 32 | S&F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door. |
| 33 | S&Fin repairs ball ptmt valve high pressure of polethene float and fly nut complete screwed for iron pipe and fixed, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed of 20mm bore as specified and directed. |
| 34 | Removal of plants/trees//Shrubs from roof tops/sides, external walls of bldg, chajjas, wall junctions of rains water/CI soil /waste pipe junctions including taking out the roots entered in wall/slab surfaces and making good the disturbed surface using (1:2:4) type B-O or cement mortar (1:2)including repairing the GI/CI/PVC pipe joints which were damged during cutting/taking out process to match with the existing and finishing the disturbed surface to match with existing including necessary scaffolding/staging upto a height of 15 .00 M from the ground level complete all as specified and directed. |
| 35 | Disconnecting water tubings near water tanks, taking out old rusted GI tube short lengths (nipples) embedded in RCC/PVC tank walls as out lets/inlets by chiselling and replacing with new nipples, making good with cement concrete 1:2:4 and refixing of tubing all as directed by Engineer-in-charge. Note: Rates are incl Supply & fixing of new nipple/long screw complete all as specified and directed. |
| 36 | M&L RCC 1:1/2 : 3 as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands plinth courses, string courses lacing courses, parapets and railings upto 60 cm in height copings, kneelers, apex stones bed plates, kerbs not provided cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. Note :- 1. Necessary from work is including this same item only 2.The Rates are inclding Use of all scaffoldings up to 14 M ht of buildings 3.TMT bar shall be measured and paid separately. |
| 37 | M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 38 | M&L for 75mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cement complete all as specified and directed. |
| 39 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on Newly Plastered surfacs of brick (plastered or un-plastered) or concrete surface including preparation complete all as specified and directed. Note: 1. Exterior Primer & Acrylic emulsion paint to be applied on wall surfaces with airless spray machine (Mechanical means) as approved by Engr-in-Charge 2nd coat shall be applied after 1st coat is dry approximately 6-8 hrs between two coats.Note :- The Rates are inclding Use of all scaffoldings up to 14 M ht of buildings. |
| 40 | M&L for complete removal of existing treatment on wall/roof projections including facia, cornices, etc by scrapping with mechanical sander (having mechnical vaccum mechanism ) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour complete all as specified and directed by Engr-in-charge. |
| 41 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on old prepared surface of brick (plastered or un-plastered) or concrete surface complete all as specified and directed. Note: 1. Exterior Primer & Acrylic emulsion paint to be applied on wall surfaces with airless spray machine (Mechanical means) as approved by Engr-in-Charge . 2nd coat shall be applied after 1st coat is dry approximately 6-8 hrs between two coats.2. Preparation of surfaces shall be measured and paid separately Note :- The Rates are inclding Use of all scaffoldings up to 14 M ht of buildings . |
| 42 | M&L for Preparation of newly plastered wall surfaces and applying Two coat of Oil Bound Distemper over a coat of primer using roller complete all as specified and directed. |
| 43 | M&L for preparation of newly plastered ceiling surfaces and applying two coats of white wash all as specified and directed. |
| 44 | M&L for preperation of old decorated plastered suface of walls applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives complete all as specified and directed. Note :- 1. Exterior Primer & Acrylic emulsion paint to be applied on wall surfaces with airless spray machine (Mechanical means) as approved by Engr-in-Charge . 2nd coat shall be applied after 1st coat is dry approximately 6-8 hrs between two coats.2. Preparation of surfaces shall be measured and paid separately 3. Rates are inclding Use of all scaffoldings up to 14 M ht of buildings . |
| 45 | M&L for preperation of old decorated plastered suface of walls applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives complete all as specified and directed. Note :- 1. Exterior Primer & Acrylic emulsion paint to be applied on wall surfaces with airless spray machine (Mechanical means) as approved by Engr-in-Charge. 2nd coat shall be applied after 1st coat is dry approximately 6-8 hrs between two coats.2. Preparation of surfaces shall be measured and paid separately 3. Rates are inclding Use of all scaffoldings up to 14 M ht of buildings . |
| 46 | M&L for complete removel of existing treatment of old plastered ceiling surfaces and applying two coats of white wash all as specified. |
| 47 | M&L for preperation of old decorated plastered suface of walls & applying two coat of distemper oil emulsion white or tinted on old decorated surfaces of walls Complete all as specified & directed. |
| 48 | M&L for one coat of synthetic enamel paint on old wood or wooden based surfaces of any description over 10cm width or girth including preparation surfaces complete all as specified and directed. |
| 49 | M&L for one coat of synthetic enamel paint on old steel surfaces of any description over 10cm width or girth including preparation of old painted steel surfaces complete all as specified and directed. |
| 50 | M&L for two coat of synthetic enamel paint on steel surfaces of any description over 10cm width or girth including preparatin of new steel surfaces over one coat of red oxide, zinc coating complete all as specified and directed. Please Enable Macros to View BoQ information |