| 1 | Taking down carefully existing copper/Aluminum point wiring (light,fan, socket or power) complete including fixture and fittings such as switches, bellpushes, ceiling roses, pendents, regulators, sockets, light fitting, call bells etc removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing complete all as specified and directed. |
| 2 | M & L for Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: - |
| 3 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified. |
| 4 | One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified |
| 5 | One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified. |
| 6 | One Bell/Buzzer point controlled by one push button with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified |
| 7 | One light point controlled by two way switch. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified. |
| 8 | One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified. |
| 9 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified. |
| 10 | One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified. |
| 11 | One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified. |
| 12 | One socket outlet three pin, 5/15 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified. |
| 13 | One Bell/Buzzer point controlled by one push button with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC heavy duty concealed conduit all as specified. |
| 14 | M & L for inverter wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable,one light point /one 5 Amp socket point only.including drawn though PVC conduct all as specified and as directed. |
| 15 | S&F Switch modular type single pole, one way, 6 Amp, one module, complete all as specified. |
| 16 | S&F Switch modular type single pole one way, 16 Amp, one module, complete all as specified. |
| 17 | S&F Switch modular type single pole, two way, 6 Amp, one module, complete all as specified |
| 18 | S&F Bell push switch modular type single pole one way, 6 Amp, one module, complete all as specified. |
| 19 | S&F Socket outlet modular type, multipurpose, 3 pin, single pole one way, 6 Amp, two module, shutter type complete all as specified. |
| 20 | S&F Socket outlet modular type multipurpose 3 pin, 2 in 1 single pole one way 6/16 Amp, two module, shutter type complete all as specified. |
| 21 | S&F in repair Modular telephone socket one module complete. |
| 22 | S&F Fan regulator, modular type, 5 step, high speed, two module complete all as specified. |
| 23 | S&F in repair Switch piano, flush type single pole, one way 5 Amp complete all as specified |
| 24 | S&F in repair Switch piano, flush type single pole, two way 5 Amp complete all as specified |
| 25 | S&F in repair Switch piano, flush type single pole, one way 15 Amp complete all as specified |
| 26 | S&F in repair Bell push 5/6 Amps 230 V AC complete all as specified |
| 27 | S&F in repair Socket outlet 3 pin, 5A, flush type all as specified |
| 28 | S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified |
| 29 | S&F in repair Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified |
| 30 | S&F in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified |
| 31 | S&F Ceiling rose, 3 terminal PVC/polycarbonate, suitable for 230 V, AC, 50 Hz supply. |
| 32 | S&F call bell ding dong type AC 230 V complete. |
| 33 | Supply and Fixing only wall mounted extruded Aluminium/ integrated LED batten fixture with tube 1.2 m, 22 watt, 1.2 m 3000/6500K, white /worm white efficacy not less than 90 lumen/watt extruded Aluminium/polycarbonate, PC diffusor and integrated inbuilt driver complete including making connection complete all as specified and directed |
| 34 | Supply and Fixing only decorative wall light fixture made of polycarbonate suitable for retrofit 9W LED lamp(base B-22) complete with PC diffusor & including one 9W LED lamp(base B-22), 3000/6500K, not less than 90 lumen/watt efficacy including making connection complete all as specified and directed. |
| 35 | Supply and Fix only integrated round shape 12/18 watt 220V AC surface type 3000/6500K,efficacy not less than 90 lumen/watt with high efficiency PMMA diffusor soft glare free light complete and integrated inbuilt driver, holders, LED lamps square/round type etc including making connection complete all specified and directed |
| 36 | S&F LED light fitting 9/10W bulkhead luminaires including LED light, driver, holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed |
| 37 | S&F Lamp holder PVC/polycarbonate type with back plate complete all as specified |
| 38 | S&F post top lantern LED type 20 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistance complete with driver and lamp complete all as specified and directed |
| 39 | S&F LED downlighter/spot light fitting, recessed mounted, round shaped of ceiling cut outφ160mm, 12watts efficacy not less than 90 lumen/watt, 3000/6500K extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed. |
| 40 | S&F LED landscape/bollard light fitting, round shaped of 0.6m pole size, 10watts, efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, IP65, PC diffusor, module and inbuilt driver complete including making connection & fixing of pole base with nut and bolt to PCC pedestal/coping complete all as specified and directed |
| 41 | S&F in repair LED AC Rope 60 LED/M 6500K/4000K IP65, waterproof, with reflector, multicolor complete C ROPE 60 LED/M Light Accessories complete all as specified and directed. |
| 42 | S&F LED string light with white/ warm white colour with minimum 50 LED/ M lamps and length 20 mtrs long out door type 6500K/4000K IP65, waterproof, with reflector, complete with all Accessories complete all as specified and directed. |
| 43 | S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 4 sqmm along with earth wire 4.0 sqmm copper conductor single core wire connected by common earth in PVC surface/recessed PVC/steel conduit complete all as specified.(Note :- two lengths of 4.0 sqmm cable and one length of 4.0 sqmm earth cable will be measured as one running length) |
| 44 | S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 6 sqmm along with earth wire 6.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit complete all as specified.(Note :- two lengths of 6.0 sqmm cable and one length of 6.0 sqmm earth cable will be measured as one running length) |
| 45 | S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 10 sqmm along with earth wire 10.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit complete all as specified.(Note :- two lengths of 10.0 sqmm cable and one length of 10.0 sqmm earth cable will be measured as one running length) |
| 46 | S&F in replacement sub main four single core PVC copper conductor unsheathed wire multi stranded 10 sqmm along with earth wire 10.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit complete all as specified.(Note :- four lengths of 10.0 sqmm cable and one length of 10.0 sqmm earth cable will be measured as one running length) |
| 47 | S&F in replacement sheet metal encloser double door VERTICAL TPN 415V 8 way ISI marked IP-54 complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed |
| 48 | S&F in replacement sheet metal encloser double door 4 way TPN 415V ISI marked IP-54 complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed |
| 49 | S&F in replacement sheet metal encloser double door 12 way SPN 240V ISI IP-54 marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed |
| 50 | S&F in replacement single pole and neutral enclosure 240V with a two pin and earth plug and socket complete with one double pole MCB 20Amp complete all as specified and directed |
| 51 | S&F in repair MCB 6-32 Amp 240V SP 10 KA ‘B’ series complete all as specified and directed. |
| 52 | S&F in repair MCB 40-63 Amp 240V SPN 10 KA ‘C’ series complete all as specified and directed |
| 53 | S&F in repair MCB 415V 40 to 100Amp TPN 10 KA ‘C’ series complete all as specified and directed |
| 54 | S&F in repair MCCB 415V, FP 100 to 125A 16kA complete all as specified and directed. Please Enable Macros to View BoQ information |
| 55 | S&F in repair MCCB 415V, FP 100 to 125A 16kA complete all as specified and directed. Please Enable Macros to View BoQ information |