| 1 | Construction of Drain work from Chamtkari Balaji Temple to Kanwarpura Road in Ward No. 28 |
| 2 | Dismantling of existing structures like culverts, bridges, retainingwalls, CC road and other structure comprising of masonry, cementconcrete, wood work, steel work, including T&P and scaffoldingwherever necessary, sorting the dismantled material, disposal ofunserviceable material and stacking the serviceable material with alllifts and lead of 50 metres as directed by EngineerCement Concrete Grade M-15 and above and PCC blocks |
| 3 | Earth work in excavation in foundation, trenches etc. includingdressing of sides and ramming of bottoms, including getting out theexcavated material, refilling after laying pipe/ foundation anddisposal of surplus excavated material at a lead upto 50m suitablesite as per direction of Engineer for following depths, below naturalground / Road top level. |
| 4 | Carriage of Materials by mechanical transport including loading, unloading andstacking :: 2 km |
| 5 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work upto plinthlevel1:5:10 (1 cement : 5 fine/ coarse sand : 10 graded stone aggregate40 mm nominal size |
| 6 | Centring and shuttering with plywood or steel sheet upto two stories( each story of height upto 3.5 metre from floor level) includingstrutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, buttresses, plinthand string courses |
| 7 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work upto plinthlevel1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size |
| 8 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded20mm nominal size stone aggregate) finished with a floating coat ofneat cement including cement slurry, but excluding the cost ofnosing of steps etc. complete. including Providing /mixing ofsynthetic fibers compulsorily complying with IS 16481:2022 of 06mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e.125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ |
| 9 | Providing, lowering, laying in trenches, aligning, fixing in position andjointing socketed rubber gasket type ISI marked uPVC pipes ofClass III (6 Kg/sqcm) suitable for potable water with rubber ringjoints (as per IS 4985-2000) of following outer dia with allaccessories (excluding specials) complete including all material,labour, hydraulic testing and commissioning as per TechnicalSpecifications and as per direction of Engineer.Note : E/w to be measured and paid separately.110 mm dia |
| 10 | Providing and Laying Reinforced cement concrete pipe NP4/prestressed concrete pipe for culverts including jointing ends andfixing collar with cement mortar 1:2 complete as per clause 1000 &2900 of MoRT&H specification including all material, labour formwork, machinery300 mm internal diameter |
| 11 | Earth work in excavation in foundation, trenches etc. includingdressing of sides and ramming of bottoms, including getting out theexcavated material, refilling after laying pipe/ foundation anddisposal of surplus excavated material at a lead upto 50m suitablesite as per direction of Engineer for following depths, below naturalground / Road top level. |
| 12 | Carriage of Materials by mechanical transport including loading, unloading andstacking :: 2 km |
| 13 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work upto plinthlevel1:5:10 (1 cement : 5 fine/ coarse sand : 10 graded stone aggregate40 mm nominal size |
| 14 | Providing granular bedding having width = outer dia of pipe (Bc) +500mm, thickness below pipe = 0.25Bc or 100mm (whichever ishigher) and haunching = 0.5Bc, with graded hard crusher brokenstone of 100% passing through 20mm sieve, 20 to 50 % passingthrough 10mm sieve and 100 % retain on 6.3mm sieve, laying inlayers of thickness 10/15cm including ramming, consolidation etccomplete for all type of pipes of following sizes as per drawing andor as directed by Engineer450 mm internal diameter |
| 15 | Centring and shuttering with plywood or steel sheet upto two stories( each story of height upto 3.5 metre from floor level) includingstrutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, buttresses, plinthand string courses |
| 16 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work upto plinthlevel1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size |
| 17 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded20mm nominal size stone aggregate) finished with a floating coat ofneat cement including cement slurry, but excluding the cost ofnosing of steps etc. complete. including Providing /mixing ofsynthetic fibers compulsorily complying with IS 16481:2022 of 06mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e.125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ |
| 18 | Providing and Laying Reinforced cement concrete pipe NP4/prestressed concrete pipe for culverts including jointing ends andfixing collar with cement mortar 1:2 complete as per clause 1000 &2900 of MoRT&H specification including all material, labour formwork, machinery.450 mm internal diameter |
| 19 | Providing and fixing of reinforced Ferro-Cement drain coversdesigned for 'AA' class loading duly marked on cover with adequatesteel reinforcement having thickness 75mm to 150mm anti corrosivebitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtureslike plasticizer, bond improving compound, shrinkage, resistancecompound, abrasion resistant complete as per approved design etcStandard Size 2100x500mm (150mm thick) for span 1201 to1500mm Please Enable Macros to View BoQ information |