| 1 | Dismentaling of pump for over hauiling including greasing, gland packing, necessary repairs & reinstallation of the same including trial run for 10 hrs. in two spell complete as per direction of the Engineer-in- Charge.For LI |
| 2 | Providing & fitting fixing C.I coupling complete with nuts & bolts of approved quality.a)150 mmφ |
| 3 | b)190 mmφ |
| 4 | Providing and fitting fixing PVC suction hose pipes overall thickness 5 mm. of best quality at site of work (pankaj made) of approved qualitya)150 mm dia. |
| 5 | Providing and fitting fixing MS Foot valve as per relevant IS specification and the direction of the Engineer-in-charge.150 mm dia |
| 6 | Supply & fitting fixing ball bearing of approved quality for pump required during overhauling.a) 6305 ball bearing (TATA /SKF) . |
| 7 | b) 6306 ball bearing (TATA /SKF). |
| 8 | c) 6310 ball bearing (TATA /SKF). |
| 9 | Providing & fitting fixing C.I. gland of approved quality.For LI |
| 10 | Providing & fitting fixing foot valve leather washer (6 mm thick) of heavy duty at site of work of approved quality150 mm dia |
| 11 | Supplying and greasing/applying of grease of approved quality as per direction of Engineer-in-charge. |
| 12 | Supplying and fitting fixing of asbestos rope of best quality asper direciton of Engineer-in-charge10 to 12 mm thick. |
| 13 | Providing & fitting fixing MS hose clamp with nuts & bolts complete as per relevent IS specification and direciton of Engineer-in-charge.A)150mm Dia |
| 14 | Providing and fixing G.I. Bend /eIbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.125 mm dia |
| 15 | 150 mm dia. |
| 16 | Providing & fitting fixing coupling rubber bush (All Size)of approved quality.For LI |
| 17 | Providing & fitting fixing coupling star bush (All Size) of approved quality. 150 mm dia. |
| 18 | 190 mm dia |
| 19 | 225 mm dia |
| 20 | Providing and fitting fixing of brass fullway valve with handle in the GI pipe line including cutting, threading etc. complete as per CPWD specification and direction of the Engineer - in - charge 40 mm dia |
| 21 | Providing & fitting fixing Shaft sleeve bush of approved quality.a)Cast iron (CI). For LI. |
| 22 | b)Stainless Steel (SS). |
| 23 | Providing & fitting fixing Gland nut / Stag nut 100 mm long for gland of approved quality. For LI. |
| 24 | Providing & fitting fixing Pump Shaft of approved quality. |
| 25 | Dismental of horizontal pump and motor of 20/25 HP from the base and carrying the pump set to the nearest workshop for repairing the body thread of stag nut and carrying the same to the scheme and fitting fixing the pump set as before as per direction of the Engineerin- charge. |
| 26 | Providing & fitting fixing coupling star bush (All Size) of approved quality. 150 mm dia. |
| 27 | 190 mm dia |
| 28 | 225 mm dia |
| 29 | Providing & fitting fixing C.I foot valve spare parts of 125/150 mm dia at site of work of approved quality.C.I foot valve weight. |
| 30 | C.I foot valve ring |
| 31 | C.I foot valve net |
| 32 | Supplying & fitting fixing of spare parts for 20/25 HP HorizontalmotorTerminal plate |
| 33 | Dismentalling of motor for vernishing, heating etc. complete in/c reinstallation and making necessary electrical connection with main switch/starter with motor in/c trial run for 10 hrs in two spell complete as per direction of Engineer-in-charge |
| 34 | Dismentaling of old pump/motor from base & stacking of materials & return the same to Sub-Divisional store as per direction of theEngineer-in-Charge. |
| 35 | Installation of pump motor set including carriage of materials from Departmental store yard to site of work and making necessary electrical connection with main switch /starter with motor in/c commissioning & trial run for 10hrs. in two spell as per direction of the Engineer-in-charge. |
| 36 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per specification and direction of the Engineer- in-charge.a) Current range 63 Amps. |
| 37 | b) Current range 200 Amps |
| 38 | Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge.i.25 HP/18.5 kw Relay range within 13-21 + 10% |
| 39 | Repairing of OSCO starter including supplying & fixing of necessary spare parts as per direction of Engg.- In - ChargeStand finger. |
| 40 | Gola finger |
| 41 | CT Coil |
| 42 | Magnet Coil |
| 43 | Supplying & fitting fixing of 63 Amps kit cut for main & sub-mainswich (Male & female) as per direction of the engineer-in-charge. |
| 44 | 200 Amps main switch. |
| 45 | Supplying & fitting fixing of PVC insulated Copper Wire with all electrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality.7/16 Copper Wire |
| 46 | Supplying and fitting fixing AC Voltmeter (Moving Iron) on the panel board of approved quality.PU4,Range 0-400 to 0-500 |
| 47 | Providing and fitting fixing of moving iron type , Range 0-100/ 0-200 amps, (96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make ) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and the direction of the Engineer-in -charge. |
| 48 | Providing & fitting fixing of pannel board of local teak wood for fitting & fixing of electrical items including 2 nos. MS angle post ( Size 50X50X6mm 2.80 Mtr. long) nuts& bolts etc. for errection of the same by 1 : 1.5 : 3 cement concreate casting (1feetX1feetX2feet) below the ground level and painting two or more coats of synthetic enamel paint on primer as per direction of Engineer-in-Charge.Size 1.80 X 1.20 X 0.025 mtr. |
| 49 | Providing & fitting fixing of G.I. flange ( 10 mm wall thickness ) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in -charge.150 mm dia |
| 50 | Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality.150 mm dia |
| 51 | Supplying & fitting fixing manually operated oil immerged starter of approved quality.30HP Osco/BCH Make |
| 52 | Supplying & filling of Transformer oil in the oil tank of manually operated oil immerged starter of approved quality. Please Enable Macros to View BoQ information |