| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.opper conductor single core cable etc as required. |
| 2 | Group C |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required |
| 4 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 5 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 6 | 2X4 sq. mm + 1X4 sq. mm earth wire |
| 7 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 8 | 4X4 sq. mm + 2X4 sq. mm earth wire |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 10 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required. |
| 11 | Armoured Cable 25 Sq.mm. (3.5 core) |
| 12 | 2.2.13 Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 13 | MCCB 200 A- 250A 36 KA |
| 14 | MCCB 32 A- 100 A 18 KA |
| 15 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 16 | 63 Amps |
| 17 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 18 | 63 Amp |
| 19 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 20 | 16 way, Double door |
| 21 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 22 | Single pole |
| 23 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 24 | 40 amps |
| 25 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 26 | Earthing with Copper earth plate 600 mmx600 mmx 6 mm thick |
| 27 | Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run) |
| 28 | Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run) |
| 29 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 30 | 8 SWG Copper Wire |
| 31 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 32 | 32 mm Dia |
| 33 | Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required. |
| 34 | Exhaust Fan Heavy duty 300 MM Sweep |
| 35 | Providing and Fixing of IP20 LED fixture of 18 watt +/- 1 W LED Surface Mounted Downlighter Round Shape with minimum system lumen efficacy of 100 lm/W with Polycarbonate housing,pressure die cast heat sink and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. |
| 36 | LED 18 watt Surface Mounting |
| 37 | Providing and fixing of IP65 Bulkhead led fixture 10 W +/- 1 W Wall Mounted with minimum system lumen efficacy of 100 lm/W with Pressure Die Cast Aluminum housing, Polycarbonate Opal Diffuser and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 .The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K only with CRI of minimum 80.The Input voltage range shall be 140V to 280V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. |
| 38 | LED Bulk Head Light 10W |
| 39 | Providing and fixing Coloured anodised aluminium frames for door, window and ventilator and glazing partitionxtrusion section of Jindal/ Hindalco a s per approved shade work for door, window, ventilator and partition witviruled built up standard tubular and other sections of approved make confirming t o IS:733 and IS: 1285 anodisetransparent or dyed to require shade accordingly to IS: 1868 (minimum anodic coating of grade AC 15) fixed withraw plugs and screws or with fixing clips, necessary filling up o f gaps and junctions a t top, bottom and sides withrequired with PVC / neoprene filles etc. aluminium section shall be smooth rust free, straight, mitred and jointedmechanically wherever required including clests angle, aluminium, snap beeding for glazing/ panelling C.P. brass / stainless steel screws all complete. |
| 40 | For shutters of doors windows & ventilators including providing and fixing hinges/pivots and making provisions for fixing of fittings where ever required including the cost of PVC/neoprene gaskets as required (fittings and glazing/panelling shall b e paid for separately). |
| 41 | Providing and laying 19mm (Nineteen milimeters) thick cheema pink granite stone having semi round nosinglaid over 20mm (twenty millimeters) thick base of cement mortor 1:3(one cement: three sand) and jointed withement sluree mix pigment to match the shade of granite stone including rubbing polishing moulding and nosingomplete a s per approved specification, drawing and design inclusive o f cost and carriage o f materials with in al leads, lifts and other incidentals, a s per the direction and entire satisfaction of Engineer-In-Charge. Rate inclusive toll tax, GST and other taxesvimposed by the Government. |
| 42 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of finst and third courses of blosn bitumen 15/25 yOl! conforming to IS ippled lot it 1.10 Keper square metre of arca for each enurse second cose of fooling l e finished bitumen felt and fourth and final course of stone grit 6 deed own sire or peasized prutel spread at f eubic decimeter per square metre. includmg preparation of surface not excluding grading complete with Bitumen |
| 43 | Finishing wall with weather proof exterior grade emulsion of approved design (Apexultima) or its equarlied on undecorated wall surfaces (two coats) to give an even shade and final finish after throughly cleaning the surface to remove all dirt, dust and other foreign matter ete including sand paper smooth complete. |
| 44 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partition etc with PVC/coprens gasket etc. complete as per the architectural drawings and the directions of Engineer-In_charge (cost of aluminium snap beading shall be paid i n basic item.) Please Enable Macros to View BoQ information |