| 1 | Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV HT line/LT line & Creation of sub stations/Augumentation of Substations. (Material and Labour) |
| 2 | 8 mtr. Long ST Pole (ST-410 SP-15) |
| 3 | 9 mtr. Long ST Pole (ST-410 SP33) |
| 4 | 8 mtr. Long PCC Pole (WL-200KG) |
| 5 | 9 mtr. Long PCC Pole (WL-300KG) |
| 6 | 11 mtr. Long ST Pole (ST-410 SP56) |
| 7 | GI V Cross -arm with top Bracket including clamps |
| 8 | GI Channel X-arm including clamps and Angle for braces |
| 9 | 30sqmm ACSR Weasel Conductor |
| 10 | 20 sqmm ACSR Squirrel Conductor |
| 11 | 50 sqmm ACSR Rabbit Conductor |
| 12 | 100 sqmm ACSR Dog Conductor |
| 13 | 50 sqmm AB(LT) Cable (3x50+1x16+1x35mm²) XLPE (1.1kv,3+1 c,Al) |
| 14 | 70 sqmm AB(LT) Cable (3x70+1x16+1x50mm²) XLPE (1.1kv,3+1 c,Al) |
| 15 | 120 sqmm AB(LT) Cable (3x120+1x16+1x70mm²) XLPE (1.1kv,3+1 c,Al) |
| 16 | Suspension/Tension Clamp With eye hook |
| 17 | Insulating piercing Connectors |
| 18 | Straight through cable jointing kit AB 50 sqmm |
| 19 | Straight through cable jointing kit AB 95 sqmm |
| 20 | Straight through cable jointing kit AB 120 sqmm |
| 21 | Straight through cable jointing kit XLPE 50 sqmm |
| 22 | Straight through cable jointing kit XLPE 95 sqmm |
| 23 | Straight through cable jointing kit XLPE 120 sqmm |
| 24 | 11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm |
| 25 | 11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings |
| 26 | Galvanized Nuts and Bolts |
| 27 | Danger Plates with Clamps |
| 28 | Anti- Climbing Device with Clamps |
| 29 | Earthing of poles complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm. |
| 30 | Painting of ST Poles 8/9/11 mtr. including cross arm, clamps with 2 coats of Aluminium Paint over 1 coat of Red Oxide |
| 31 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 32 | CT PT unit along with3 phase trivector meter and along with control cables and other allied acessories |
| 33 | 11/0.433kV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate |
| 34 | 11/0.433kV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate |
| 35 | 11/0.433kV, 3-phase 100 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate |
| 36 | 11/0.433kV, 3-phase 250 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Copper Wound, and with LV Cable Box having detachable Aluminium Gland plate |
| 37 | 11/0.433kV, 3-phase 400 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Copper Wound, and with LV Cable Box having detachable Aluminium Gland plate |
| 38 | Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type |
| 39 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 40 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 41 | 95 mm² Single-Core Cable, 1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type including Thimbling |
| 42 | 120 mm² Single-Core Cable, 1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type including Thimbling |
| 43 | 185 mm² Single-Core Cable, 1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type including Thimbling |
| 44 | 300 mm² Single-Core Cable, 1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type including Thimbling |
| 45 | 400 mm² Single-Core Cable, 1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type including Thimbling |
| 46 | LT Distribution box for 25 KVA DTR with MCCB for incomer and SfU's for outgoing circuits. |
| 47 | LT Distribution box for 63 KVA DTR with MCCB for incomer and SfU's for outgoing circuits. |
| 48 | LT Distribution box for 100 KVA DTR with MCCB for incomer and SfU's for outgoing circuits. |
| 49 | LT Distribution box for 250 KVA DTR with MCCB for incomer and SfU's for outgoing circuits. |
| 50 | LT Distribution box for 400 KVA DTR with MCCB for incomer and SfU's for outgoing circuits. |
| 51 | Cement bottoming of ST poles in 1:2:4 mix as per REC standards |
| 52 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 25mmX3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber with RCC slab cover. |
| 53 | Painting of substation ST poles/cross arms/clamps with one coat of Red oxide and two coats of aluminium paint |
| 54 | LT Switch made of Flat iron 50x6mm Aluminium strip 50x6mm fixed on Bus bar insulator complete |
| 55 | 3 phase 4 wire LT Prodigy Meter |
| 56 | GI Mukki/U-Clamp for shackle insulator |
| 57 | Pole mounted 1phase LT distribution Box with minimum four numbers of Meter Capabilities |
| 58 | Pole mounted 3 phase LT distribution Box with minimum two numbers of Meter Capabilities |
| 59 | 16kN Shackle Insulators |
| 60 | LT line spacers (1-phase, 2-wire) |
| 61 | LT line spacers (3-phase, 4-wire) |
| 62 | PG Clamps of different sizes |
| 63 | T Clamps 630 mm |
| 64 | T Clamps 400 mm |
| 65 | 11KV 3 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 50 SQMM |
| 66 | 11KV 3 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 70 Sqmm |
| 67 | 11KV 3 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 95 Sqmm |
| 68 | 11KV 3 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 120 Sqmm |
| 69 | 11KV 3 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 185 Sqmm |
| 70 | LT 3.5 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 25 SQMM |
| 71 | LT 3.5 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 35 Sqmm |
| 72 | LT 3.5 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 50 Sqmm |
| 73 | LT 3.5 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 70 Sqmm |
| 74 | LT 3.5 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 95 Sqmm |
| 75 | LT 3.5 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 120 Sqmm |
| 76 | LT 3.5 core XLPE of reputed make like Havels polycap etc or its equivalent as per IS standard of 185 Sqmm |
| 77 | Heat Shrinkable Kit (Outdoor type )11KV of 95 sqmm XLPE |
| 78 | Heat Shrinkable Kit (Outdoor type )11KV of 120 sqmm XLPE |
| 79 | Heat Shrinkable Kit (Outdoor type )11KV of 95 sqmm AB Cable |
| 80 | Heat Shrinkable Kit (Outdoor type )11KV of 120sqmm AB Cable |
| 81 | LT Pannel comprising of Feeder pillar box made of 1.5 mm thick CCRA Sheets, Powder coated comprising of Incomer MCCB 200 A 4poles 35 KA -1 No., Outgoing MCCB 63 A 4 poles 25 KA -5 No., Aluminium Bus bar 200 A capacity 1 set , Voltmeter ammeter indicator set - 1No., Supplying and fixing of Star Delta starter 10 HP automatic- 5Nos, Copper Cable 10sqmm 200 mtr ,3 and 1/2 XLPE Armoured 70 sq mm-200 mtrs |
| 82 | Dismantling of old 25/63/100 KVA Transformer with allied works & carriage /transportation of dismantled transformer/materials from site to Divisional Store Udhampur. |
| 83 | Dismentling of old 250/400 KVA Transformer with allied works & carriage /transportation of dismantled transformer/materials from site to Divisional Store Udhampur. |
| 84 | Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV HT line/LT line & Creation of sub stations/Augumentation of Substations. |
| 85 | 8 mtr. Long ST Pole (to be supplied by the deptt. At Divisional Store of ED Udhampur) |
| 86 | 9 mtr. Long ST Pole (to be supplied by the deptt. At Divisional Store of ED Udhampur) |
| 87 | 8 mtr. Long PCC Pole (to be supplied by the deptt. At Divisional Store of ED Udhampur) |
| 88 | 9 mtr. Long PCC Pole (to be supplied by the deptt. At Divisional Store of ED Udhampur) |
| 89 | 11 mtr. Long ST Pole (to be supplied by the deptt. At Divisional Store of ED Udhampur) |
| 90 | 50 sqmm AB(LT) Cable (3x50+1x16+1x35mm²) XLPE (1.1kv,3+1 c,Al) (to be supplied by the deptt. At Divisional Store of ED Udhampur) |
| 91 | 70 sqmm AB(LT) Cable (3x70+1x16+1x50mm²) XLPE (1.1kv,3+1 c,Al) (to be supplied by the deptt. At Divisional Store of ED Udhampur) |
| 92 | 120 sqmm AB(LT) Cable (3x120+1x16+1x70mm²) XLPE (1.1kv,3+1 c,Al) (to be supplied by the deptt. At Divisional Store of ED Udhampur) |
| 93 | 30 Sqmm ACSR Weasel Conductor (to be supplied by the deptt. At Divisional Store of ED Udhampur) |
| 94 | 20 Sqmm ACSR Squirrel Conductor (to be supplied by the deptt. At Divisional Store of ED Udhampur) |
| 95 | 50 Sqmm ACSR Rabbit Conductor (to be supplied by the deptt. At Divisional Store of ED Udhampur) |
| 96 | Transformer 25 KVA ( to be supplied by deptt at Divisional Store of ED Udhampur. |
| 97 | Transformer 63 KVA ( to be supplied by deptt at Divisional Store of ED Udhampur. |
| 98 | Transformer 100 KVA ( to be supplied by deptt at Divisional Store of ED Udhampur. |
| 99 | Transformer 250 KVA ( to be supplied by deptt at Divisional Store of ED Udhampur. |
| 100 | Transformer 400 KVA ( to be supplied by deptt at Divisional Store of ED Udhampur. Please Enable Macros to View BoQ information |