| 1 | Earth Work of open excavation of made up soil except hard roak requiring blasting and depositing on bank with in all leads and lifts as per SS20B, including cost of all labour, equipments and all incidental charges such as bailing out water, providing and maintaining necessary cofferdams, sheeting, shoring, bracing and their subsequent removal, removal of all logs, stumps, grubs and other deleterious matter and obstructions, trimming bottom of excavation backfilling, and clearing the site and disposal of all surplus materials etc., completer as per relevant standard specification |
| 2 | Plain Cement Concrete 1:4:8 (one cement four Parts of crushed stone M-sand and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification (The crushed stone sand to be used on cocrete work shell conform to gradation as per IS :383-1970 ) |
| 3 | Centering for soffits of RCC slab including strutting up to 3m in height using M.S. sheets of size 80cm x 60cm B.C. 10’ gauge stiffened M.S. angles of size 25mm x 25mm x 3mm laid down silver oak (country wood) joists of size 10cm x 6.50cm (spaced at about 75mm c/c) and supported by casuarinas props of 10cm to 13cm dia (spaced at about 75mm c/c) complying with std. specification as directed by the departmental officers |
| 4 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - |
| 5 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors |
| 6 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9\\" X 43/8\\"X 2 3/4\\" including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 7 | Plastering with cement mortar (1:4) 20mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309) |
| 8 | Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 9 | Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 10 | Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. |
| 11 | Wiring with 2x1.5sqmm(22/0.3) PVC insulated unsheathed SC. Cu.Conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A F.T. switch inflush with wall, covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (For electronic regulator) (5 Points Per Coil) SD 22 |
| 12 | supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 Von 7/20 GI bearer wirefor service connection mains SD 65 |
| 13 | Supply and fixing of 4 Feet LED 18W Fitting with LED 18W tube (Lower End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting SD-440 |
| 14 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete. |
| 15 | Providing bus shelter in stainless steel columns of four numbers(302 SS) at size 150 mmx to a height of 2.44 m, roof frame of SS 202 @ 302 section size 50 mm x50 mm etc, including multi walled wallet poly carbonate sheet of 6 mm size of 6 .00 mx 2.00 m the number of members with three numbers of 4 seater seating arrangements and necessary bolts and nuts top bottom and side breakers 1500 mm dia stainless steel vertical 3.15 mm horizontal pipes front flashing and L angles are front and back rest stainless steel sheet with 1.6 mm thick sear rest with support pipes provision for roote board of 2 mm thick outer frame using 3 mm thick acrylic sheet od 5 mm thick for signage board lighting board arrangements including all fixtures and bolts nuts etc., |
| 16 | GST18% Please Enable Macros to View BoQ information |