| Sl. No. | Item Description |
| 1 | H.S.R. Item |
| 2 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2Outer Sheathed, /1100V grade as per IS 7098(Part 1) 1988with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-incharge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables.70Sqmm size |
| 3 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2Outer Sheathed, /1100V grade as per IS 7098(Part 1) 1988with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-incharge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables.25Sqmm size |
| 4 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2Outer Sheathed, /1100V grade as per IS 7098(Part 1) 1988with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-incharge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables.16Sqmm size |
| 5 | Motorized Gate valve: Removal of existing gate valves and Supply, Installation, Testing and Commissioning of motorized gate valves as per design in existing Channels (MOC of valve SS-316) including Electrical Panels, Electro-mechanical actuator non intrusive type with IP-68protection with manual override wheel integrated with central PLC/SCADA, cables along with tray, Civil works, elctric and instrumentation work complete in all respect as Per Specifications and make mentioned in the DNIT. |
| 6 | Mechanical Grit Mechanism: Desilting, cleaning and removal of existing grit mechanism and Supply, Installation, Testing and Commissioning of Mechanical Grit mechanism including screw classifier, deflector, Electro-mechanical actuator non intrusive type with IP-68protection with manual override wheel integrated with central PLC/SCADA, scrappers, valves, cable with tray, panel, Organic return pump with drive head, scrapper, valves, electric and instrumentation work in existing grit channel for 15 MLD average flow with peak factor 2.25complete in all respect as per specification mentioned in DNIT |
| 7 | AIR BLOWER: Removal of existing blowers including all components. Supply, Installation, Testing and commissioning of Rotary Twin/Tri Lobe type Air Blower having capacity 3750NM³/Hr along with suitable size main header MS pipe epoxy coated, electric motor, acoustic, VFD panels including Electromechanical actuator with IP-68protection integrated with central PLC/SCADA, suitable size Power, control/signal cables along with tray and all other civil, electrical, mechanical and instrumentation work complete in all respect as per the specifications of DNIT` |
| 8 | CENTRIFUGE: Removal of installed damaged centrifuge pumps, Providing and installing 2no. centrifuges as per design (1Working plus 1Stand bye) including, feed pump, VFD panels with Electro-mechanical actuator with IP-68protection integrated with central PLC/SCADA, suitable size Power, control/signal cables along with tray, replacement of all open and underground pipe fittings and all other civil, electrical, mechanical and instrumentation work complete in all respect as per the specifications of DNIT |
| 9 | CHLORINATION SYSTEM: Design, installation, Testing and commissioning of Chlorination system including chlorine dosing pumps, Emergency equipments, complete in all respect. for 15.00MLD STP complete in all respect and entire satisfaction of Engineer-in-charge |
| 10 | Electromagnetic Flow meter: Supply, installation and commissioning of Electromagnetic Flow meter of 800 mm Dia, 4-20mA output and RS-485communication complete in all respect as per specifications mentioned in DNIT (2at treated effluent) |
| 11 | Supplying, Installation, Testing and Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV plus or better norms along with having Prime Power Rating of KVA as below, 415volts at 1500RPM, 0.8 lagging power factor at 415V suitable for 50Hz, 3phase system, including testing at factory and site with fuel, load for test and other necessary arrangements with rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Turbocharged Diesel engine 4stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500RPM suitable for above output of alternator at 40Deg C, 50%RH and at 1000Meter MSL , capable of taking 10%over loading for one hour after 12hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV plus or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018. (B) Engine mounted Instrument Panel fitted with and having digital display for following: (As per HSR, Gazette notification no. 15-2026Dated on: 13April 2026)(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubrication Oil trip indication(ix) Engine Running Hours indication (x) Fuel Level` (C) Alternator: Synchronous alternator rated of appropriate KVA, 415volts at 1500RPM, 3phase 50Hz, AC supply with 0.8lagging power factor at 40 0C, 50%RH and at 1000Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10%over loading for one hour after 12hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613suitable for tropical conditions and with class- H insulation. (D) Base Frame and Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (E) FUEL TANK: Daily service fuel tank of suitable liters capacity, fabricated out of 3mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications and accessories as required as per specifications. (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/conection through bus-trunking. Such arrangements on acoustic enclosure should be water proof and dust-proof conforming to IP-65protection. The enclosure shall be as per CPCB IV plus or better norms etc. and.(I) AMF Panel: Free standing floor mounted IP 42automatic mains failure control panel including auto bypass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering and protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase and Total), KW and provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4pole motorised electrically operated draw out with cradle type 3position ACB/ MCCB with electronic release for O/C and E/F and shunt trip. `2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2nos Over voltage relay, 2Nos. reverse power relay and 2Nos. under voltage relay).4. 3Sets of current transformers 15P 10accuracy for protection and 15VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN and L_L), kW, kVA (Phase and Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier,D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour and due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel, interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.19. Suitable rating of AC contactors/ ATS / ACB with control wiring.` 100KVA |
| 12 | EWQMS (Effluent water quality monitoring system): Supply, Installation, Testing, Commissioning, Operation and Comprehensive Annual Maintenance of effluent quality monitoring system at 15.00MLD capacity STP for online (continuous) measurement of PH, Total Suspended Solids (TSS), Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cables, local data acquisition and display of data on continuous basis for up linking the data to CPCB, HSPCB and PHED, TUV approved complete in all respect as per Central Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluents.Multi-parameter measuring converter, for connecting up to 18intelligent sensors Scope including 8analog inputs / outputs (4inputs and 4outputs) (0/4-20Ma), wide- range power supply Optical COD/BOD and TSS probe with spectral processing of the UV-VIS range, for measurement in the outlet / effluent of 15.00MLD capacity STP with integrated with automatic cleaning complete in all respect.Robust digital pH/ORP sensor for pH/ORP electrodes, with built-in pre-amplifier and temperature sensor with Automatic Temperature Compensation (ATC) Cable length 100Meter (minimum) complete in all respect.Sensor adapter cable for all intelligent sensors, with IP68water proof connection to the intelligent Sensor Net system. Cable length 100meter (minimum) complete in all respect.Data transfer to CPCB, HSPCB and PHED servers complete in all respect.Providing GSM 3G, 4G modem with mobile network connectivity including network including complete in all respect. |
| 13 | Replacement of panel of 320KVA DG set including Battery, charges, body damages etc complete in all respect as per site condition and scope of work mentioned in DNIT |
| 14 | HT Metering Panel: Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 11kv, 3phase 50hz AC, Supply with short circuit fault level of 500Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (1IC plus 2OG)a). VCB, 11KV, 630Amp, 50KA.b). 1ph 11KV/110Volts PT (indoor type) Class 0.2Accuracy and 100VA burden -3no’ s.c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5A of 15VA burden, PS 5P10and accuracy class 0.2.d). Control panel- Cubicle type control panel suitable |
| 15 | Air Blowers 450cub/Hr 12H.P motors and Air blowers 12H.P ( Centrifuge system ) |
| 16 | Inlet STP plant gate size 200mm gear operated flanged (Blower) |
| 17 | Motorised Air valve size 150mm ( CI/DI PN16, Electric actuator) |
| 18 | Motorised Air valve size 400mm` (Air release valve ,CI body Double orifice) (Air blower) |
| 19 | centrifuge Size 300mm ( Small Sludge Centtrifuge) |
| 20 | MS/ Line replacement Air blower in sludge area size 80MM/50MM/40MM/ |
| 21 | Diffusers UPVC Pipe fitting Astrel / peince/suprime |
| 22 | STP Plant panel dressing / connecter /MCB/ copper thimble |
| 23 | Credit of old removed / Dismantled / disused / abandoned parts and materials along with all accessories complete in all respect of various components of both units of 15.00MLD STP Charkhi Dadri road such as Mechanical fine screen, Motorized gate valves, Mechanical grit mechanism, sluice gate valves, 6Air blowers having 3750cum/hr capacity, 2Centrifuges, damaged parts of Decanters, Actuators, Flow meters, RAS, SAS pumps, panels and chain pulley, Effluent quality monitoring system, Panel, Battery etc which is to be removed by contractor or available at site laying disused. |
| 24 | Less credit for old Good bricks |
| 25 | Less credit for old bricks bats |
| 26 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications with PN 1.6 complete in all respect of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and specified makes as per direction of Engineer in charge. (As per HSR, Gazette notification no. 15-2026 Dated on: 13 April 2026) 100 mm dia |
| 27 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications with PN 1.6 complete in all respect of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and specified makes as per direction of Engineer in charge. (As per HSR, Gazette notification no. 15-2026 Dated on: 13 April 2026) 150 mm dia |
| 28 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications with PN 1.6 complete in all respect of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and specified makes as per direction of Engineer in charge. (As per HSR, Gazette notification no. 15-2026 Dated on: 13 April 2026) 250 mm dia |
| 29 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for non clog sewage submersible pump motor rating of 40HP Comp tible to work with cable length of 100meters. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35%VFD should be capable of providing starting torque up to 200%while starting motor. It should have class 3C3(Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485Modbus RTU, Ambient Temperature -Heavy Duty: -10~ 50deg C Normal Duty: -10~ 40deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3class 3C3, Application Humidity Below relative humidity 95%RH (no condensation) Altitude 0to 1,000m Without deration 1,001to 4,000m With deration of 1%per rise in 100m, Vibration Up to 9.8m/sec2(1.0G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200%at 0.5Hz in Sensorless Vector Control and 150%at 3Hz in V/F, Frequency Control Range 0to 400Hz in V/F, 0to 300Hz in Sensorless 1, 0to 120Hz in Sensorless 2/ Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For IPS-Auto Market) |
| 30 | Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials (excluding CI/DI fittings) and making connection with existing pipeline required for Electromagnetic Flow Meter including cutting the existing pipe line etc. complete in all respect as per Technical Specifications and specified makes as per direction of Engineer in charge. (As per HSR, Gazette notification no. 15-2026Dated on: 13April 2026) EMF 300for DN 300mm |
| 31 | Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials (excluding CI/DI fittings) and making connection with existing pipeline required for Electromagnetic Flow Meter including cutting the existing pipe line etc. complete in all respect as per Technical Specifications and specified makes as per direction of Engineer in charge. (As per HSR, Gazette notification no. 15-2026Dated on: 13April 2026) EMF 600for DN 600mm 20.155.10 |
| 32 | Design, Manufacture, Supply, Installation,Testing and Commissioning of Indoor type PLCPanel of size approx. 800mm X 500mm X2000mm (LBH) , Fabricated out of min. 2mmthick CRCA sheet complete with latestconfiguration, necessary programming softwarefor PLC and SCADA and comprising of allaccessories not limited to the following:(As per RUIDP Rajasthan)` DI ,DO ,AI ,AO ,MCB 16A DP, MCB 6A DP, SMPS 100-240VAC/ 4.5A / 24VDC Selector Switch (Auto/Manual) and Local / Remote Control Relays `Annunciator with 24Windows NO to NC Type Microprocessor Based, Window Size 75*42mm,110VAC, with` Electronic Hooter Control Transformer 200VA Emergency STOP Push Button Panel Cooling Fan and Filter Panel Light with Door Switch, 7W Control Indication Lamp for 24VDC, 220VAC Push Button `Power Wiring plus Control Wiring plus Control TB/ Fuse2A,TB etc` `Panel Hardware, lugs, terminations, ferruls,name plate Ect.` UTILITY SOCKET 16A, 3PIN HMI Display 10Inch, Colour Isolators Dual Output, 24VDC |
| 33 | Fine Bar screen:- Supply, Installation, Testing and Commissioning of stainless steel (SS-316) Fine Bar screen (Mechanical operated) with flat bar 50mm X 2mm with 6mm spacing suitable for mounting in channel of specified size with suitable inclination complete in all respect as per technical specification, specified make and direction of the Engineer-in-Charge inclusive of Upstream Type Ultrasonic Level Sensor for following PEAK FLOW and length up to 3M. (As per HSR, Gazette notification no. 15-2026Dated on: 13April 2026) for 15.00MLD average flow with peak factor 2.25 |
| 34 | Sluice Gates:- Supply, Installation, Testing and commissioning of CI Open Channel Sluice Gates, Manually operated, Rising Spindle type suitable for mounting in between two parallel walls of an Open Channel. Water sealing shall be provided at two vertical sides and bottom side of gate aperture by means of rubber seal, mounted on gate slide and having forced contact with gate aperture. The gate shall be designed in such a manner, so that it can be operated at 2meter head. Gate frame and Shutter of CI Grade IS 210FG 260, Head Stock IS 210Grade FG 260, Hinge Pin SS ASTMA276, Yoke IS MS 2062, Flush Bottom Seal Support Bar of SS ASTM A276, Stem Operating Nut ASTM A276., Duly tested for tensile strength, Chemical testing and tested Shop tested for overall dimensions as per approved GA drawing complete in all respect as per specification and direction of Engineer in charge for following PEAK FLOW up to 3m channel depth.(As per HSR, Gazette notification no. 15-2026Dated on: 13April 2026) for 15MLD average flow with peak factor 2.25 |
| 35 | Flow Control Valve:- Providing, lowering, laying, aligning, fixing in position jointing in pipeline following dia D/F DI diaphragm type (Flow Control Valve) PN 1.6class with Electrical actuator valve, suitable for SCADA compatibility complete (including jointing and jointing material) including all material, labour, testing and commissioning as per Technical Specification and specified makes as per direction of Engineer in charge.(As per HSR, Gazette notification no. 15-2026Dated on: 13April 2026) For raw sewerage rising main line 600mm diameter |
| 36 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for non clog sewage submersible pump motor rating of 17.50HP Compatible to work with cable length of 100meters. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35%VFD should be capable of providing starting torque up to 200%while starting motor. It should have class 3C3(Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485Modbus RTU, Ambient Temperature -Heavy Duty: -10~ 50deg C Normal Duty: -10~ 40deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3class 3C3, Application Humidity Below relative humidity 95%RH (no condensation) Altitude 0 to 1,000m Without deration 1,001to 4,000m With deration of 1%per rise in 100m, Vibration Up to 9.8 m/sec2(1.0G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200%at 0.5Hz in Sensorless Vector Control and 150%at 3Hz in V/F, Frequency Control Range 0to 400Hz in V/F, 0to 300Hz in Sensorless 1, 0to 120Hz in Sensorless 2/ Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For IPS-Auto Market). |
| 37 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for non clog sewage submersible pump motor rating of 10HP Compatible to work with cable length of 100meters. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35%VFD should be capable of providing starting torque up to 200%while starting motor. It should have class 3C3(Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485Modbus RTU, Ambient Temperature -Heavy Duty: -10~ 50deg C Normal Duty: -10~ 40deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3class 3C3, Application Humidity Below relative humidity 95%RH (no condensation) Altitude 0to 1,000m Without deration 1,001to 4,000m With deration of 1%per rise in 100m, Vibration Up to 9.8 m/sec2(1.0G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200%at 0.5Hz in Sensorless Vector Control and 150%at 3Hz in V/F, Frequency Control Range 0to 400Hz in V/F, 0to 300Hz in Sensorless 1, 0to 120Hz in Sensorless 2/ Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For IPS-Auto Market) |
| 38 | HOT AIR OVEN: -• Size: 18x18x24inches• Precise Sterilization, Incubating and drying in one unit.• Better mineral / glass wool blanket insulation keeps the surface of the Instrument from being burnt.• Silent Hot Air blower unique Design of air circulation for uniform Air movement.• Unique design of Ventilation keeps the surface of the instruments from being burnt.• Polish 304grade S. Steel interior corrosion resistant long-life operation having adjustable shelves to make more space for different height.• Kanthal A-1, Super quality coil shaped heaters duly embedded / wounded on the sides and bottom for better accuracy.• Full feature with Touch Screen ControllerTemperature Controller:• HMI Display with Feather Screen Touch Digital Temperature Controller• Continuous display of Temperature, Time, Day and Date Door Open Alarm• Password Protected operations,• Data transfer port: USB portTechnical Specification:Microprocessed Electronic Digital Controller cum Indicator from few `C above ambient to 300°C ± 0.5°C having two windows display SV (Set value) and PV (Process value), auto tuning, timer up 999min (selectable) low and high temperature accuracy alarm, cycle, timer with buzzer.• Temperature Stability: ± 0.5°C• Control Panel: With Mains and Load Indicator, MCB Alarm, • Material: GI/ MS with Powder Coated• Inner: Stainless Steel 304, • Digital Setting: 0.1°C, • Digital Resolution: 0.1°C• Safety Function: Temp Over shoot high and Low Temp. Alarm ± 5°C, MCB Provided, • Insulation: Mineral Wool • Front Door: Mineral wool insulated door with glass window• Hardware: Lock and Handle Material Zinc, Base Finish: SPC, Handle Finish: Black PC with key Hinges Material Zinc, Pin Material: SS 304Grade, Finish STPC, Opening Angle: 180Deg• Power Consumption: 220/230V AC Supply ± 10%. 50HZ• Duty Cycle: Continuous,• Traceability calibration certificate of controller should be provided.• Instrument should be calibrated from NABL calibration laboratory. Steel stand should be provided along with tyres on which instrument has to be kept.` |
| 39 | Handheld Meter with pH, Conductivity and DO:- Calibration • Decimal: (1D/ 0.1D/ 0.01D):• Molar: (0.1M/ 0.01M/0.001M)• NaCI: s (0.05%: 25uS/cm: 1000uS/cm: 18mS/cm): • Standard User defined/ pH with calibration editing option, ion concentration (ISE) with calibration editing option, relative/ USA: 1.68, 4.01, 7.00, 10.01, 12.4• NIST: 1.68, 4.01, 6.86, 9.18, 12.45, • DIN: 1.09, 3.06, 4.65, 6.79, 9.23, 12.74• PWB: 4.10, 6.97v, • Compliance Certifications: NIST,• Warranty: 1year• Calibration Intervals/Alerts/Reminder Off, selectable from 2hours to 7days Contents• Continuous / Auto-stabilization (``press to read``) / At Interval/ Automatic data logging with Auto- Read and Timed measure modes: manual data logging with Continuous m• Conductivity Measurement Range: 0.01pS/cm - 200.0mS/cm• Conductivity Resolution: 0.01pS/cm- 0.1mS/cm upon selected measuring range• DO Measurement Range: 0.0- 90.0mg/L (ppm) but not less than 20mg/I• DO Resolution: 0.1mg/I• pH Measurement Range: 0- 20pH but in higher range not less than14.0• pH Resolution: Selectable: 0.001/0.01/0.1pH• pH Electrode calibration: Minimum 1-3Calibration points Calibration summary data logged and displayed• ISE Electrode Calibration: 2- 5Points• TDS Measurement Range: 0.00mg/L - 50.0g/L NaCI/0.001ppm to 200.0ppt, • TDS Resolution: 0.01mg/L up - 0.1g/L upon measuring range• Automatic Buffer Recognition: Yes• Barometric Pressure Measurement: Automatic compensation of DO when using an LDO or LBOD probe• Data Export: Download via USB connection to PC or flash memory device. Automatically transfer entire data log or as readings are taken.• Data Memory: Minimum 500records/FIFO Data Storage: Automatic, GLP ISO compliant reading data stored with calibration details.• Display: Detailed mode/Large mode,• Display Type: LCD with backlight illumination• With included Meter kit includes field case, 4 AA batteries, protective meter glove, and power adapter, USB/DC power adapter for data transfer, quick-start guide and user manual |
| 40 | BOD Incubator:- • Capacity: 171L• Volume: 6Cu ftRefrigerated Insulation and Freezing in one unit.• Puff Insulated to keep the surface Temp. of body comfortable and avoid Cooling loss.• Silent energy saving Kirloskar/ Tecumseh compressor,• Polish 304grade S. Steel interior corrosion resistant long-life operation having adjustable shelves to make more space for different Height.• Kanthal A-1tubular heater is fitted for better accuracy.• Safety Controller are provided with the Digital TemperatureController Cum Indicator.• Full features Touch Screen Controller• Inner glass door with Aluminium Frame Powder coated full view door to observe the Test.• Angle Iron Frame at bottom with castor wheel for easy movement.• Fitted with 2Nos. Fan (One for Cooling and One for Heating inside the chamber)Technical Specification• Temperature Range: 5°C- 60°C,• Temperature Stability: ± 0.5°C Max• Material: GI Sheet with powder Coated• Inner: Stainless Steel 304Grade• Safety Function: Safety Controller for safety of Digital Temp. Controller Cum Indicator and Cooling Compressor with MCB.Temperature Controllera. HMI Display with Feather Screen Touch Digital Temperature Controllerb. Continuous display of Temperature, Time, Day and Date Door Open Alarmc. Password Protected.d. Data transfer port: USB port• Cooling: Fan Cooled,• Nominal Power: - 1/3hp,• Voltage Range: - 187-264V, Type CSR, • Refrigerant: R134a,• Along with installed UPS Battery/UPS System-2KVA• Included castor wheels for easy mobility of the equipment, • Duty Cycle: Continuous, • Along with NABL Calibration certificate` |
| 41 | Bacteriological Incubator:-INCUBATOR• Size: 18x18x24inches• Precise Sterilization, Incubating and drying in one unit.• Better mineral / glass wool blanket insulation keeps the surface of the Instrument from being burnt.• Silent Hot Air blower unique Design of air circulation for uniform Air movement.• Unique design of Ventilation keeps the surface of the instruments from being burnt.• Polish 304grade S. Steel interior corrosion resistant long-life operation having adjustable shelves (shelves as required by lab)• to make more space for different height.• Kanthal A-1, Super quality coil shaped heaters duly embedded / wounded on the sides and bottom for• better accuracy.• Full feature with Touch Screen Controller Temperature Controllera. HMI Display with Feather Screen Touch Digital Temperature Controllerb. Continuous display of Temperature, Time, Day and Date Door Open Alarmc. Password Protected operations,d. Data transfer port: USB portTechnical Specification• Temperature Range: Ambient to 70°C, • Temperature Stability: ± 0.5°C, • Control Panel: With Mains and Load Indicator, MCB Alarm• Material: GI/ MS with Powder Coated, • Inner: Stainless Steel 304, • Digital Setting: 0.1°C• Digital Resolution: 0.1°C, • Safety Function: Temp Over shoot high and Low Temp. Alarm ± 5°C, MCB Provided• Insulation: Mineral Wool,• Front Door: mineral wool insulated door with glass window• Hardware: Lock and Handle Material Zinc, Base Finish: SPC, Handle Finish: Black PC with key• Hinges Material Zinc, Pin Material: SS 304Grade, Finish STPC, Opening Angle: 180”C• Power Consumption: 220/230V AC Supply plus 10%. 50HZ• Duty Cycle: Continuous• 1year warranty NABL Calibration certificate as required by laboratory` |
| 42 | Magnetic Stirrer with Hotplate (5Station):- • Magnetic stirrer 2litres capacity with hot plate and Digital Speed Indicator• Speed: 2000RPM• Heating Plate Material: Glass Ceramic Top Plate• Dimension of Heating Plate: 180mmx180mm• Two display windows for Temperature and RPM• Heat Output: 1300W• Temperature Range: Ambient to 550°C• Adjustable safety cut off: 580°C• Control accuracy of sensor: ±1K• Permissible ambient Temp.: 5- 40°C• Permissible relative moisture: 80%• USB Port: Yes (for Programming)• 7pcs Magnetic stirring bar inclusive• Dimensions of Hot Plate Body: 378mm x220 mm x103mm• IP Class -21` |
| 43 | Laboratory Refrigerators:-• Storage Temperature: 2-8”C, Vertical Shelves at least6for storage of samples, Storage Capacity 500Litres along with in-built digital temperature controller (company fitted).• Door for restricted accessibility. Castor wheels for easy mobility. Toughened glass door.• Enabled digital temperature controller to check and maintain inside temperature.• NABL calibration certificate.1year warranty as desired by concerned lab` |
| 44 | Analytical Balance:-• Analytical Balance, Capacity 220gm, Accuracy/resolution 0.01mg with internal calibration Pan Size Ø 90mm along with NABL Calibration certificate.• Provide Acrylic sheet cabinet box along with weighing balance (2feet x 2feet x 2feet) or as required by laboratory. • 1year warranty` |
| 45 | Muffle Furnace:-• Rectangular Muffle Furnace: Maximum Temp. 950°C working temp.900°C.The outer casing is made of double walled thick P.C.R.C. sheet painted with attractive stove enamel. Outer body of S.S 304grade. Heating elements are made of KANTHAL wire backed by cera wool insulation. temperature control unit consists of Energy regulator and Digital Indicator with silver thermal fuse or with PID Micro Processor controller dual dis ay with safety alarm to work on 220/230volts AC with an accuracy of ±12°C or Better.• Along with Digital timer of 99.59Hours, size -10x5x5inches. Control panel- Mains, Load Indicator, Digital Controller and Mains Indicator.• NABL Calibration certificate` |
| 46 | Water bath:-• Nominal capacity - 20L, 8holes with lid assembly• Working Temperature range — ambient to 99°C• Temperature stability ± 2.0°C• Interior dimensions (528x 325x 150) mm• Exterior dimensions (W x D x H) (530x 326x 2600)mm• Display 7Segment LED Display Tank material SS 304• Outer body SS 304• Electrical Requirements 9A• Power Consumption 1600W• Calibration certificate from NABL Lab |
| 47 | Colony Counter:- • Digital display• Min count: 9999• Dish size: 110mm• Magnification: 1.7x magnification or 2x. LED display with audio beep at every count• Full SS fabricated body duly heat cured epoxy coated from outside• Marking Pen, Magnifying Lens, Lens Holder, Operation Manual and Dust Cover or manual count switch for counting without marker pen` |
| 48 | pH Meter:-• pH Range 0to 14.00pH• Resolution/Accuracy 0.001pH/ plus 0.005pH• Operation Temp 0°C-100°C• ORP Range plus 2500mV• USB interface USB (device), data output• Resolution (beyond): 0.1( plus 1200.0mV) / 1mV• EMC- EC directive 2004/108/EC EN61326-1• Dimension: 240x190x 80mm• Weight: 0.8kg• Temp range: 0.0to100.00°C• Resolution/Accuracy: 0.1°C/ plus 0.3°C (0to 70°C)• ATC: Yes (0to1000°C)• Buffer Options USA: pH 1.68,4.01,7.00,10.01,12.45• NIST: pH1.68,4.01,6.86,9.18,12.45• No. of pH Calibration Points: minimum 3points• Electrode Arm: Yes• Memory: 100data sets• Electrode: Included ECFC7252101B, single junction pH electrode.• Temp Probe: Included• LCD DISPLAY CUSTOM dualdisplay LCD(5.6X7.Scm) Power Requirements Included, 100 /240VAC SMPS Universal Power Adapter. Inclusiveof pH electrode.` |
| 49 | SBR Decanter: Removal of damaged / non functional parts of Decanter and supply, Installation, Testing and commissioning the same as per existing site conditions for 15MLD average flow including motorized arm, DO Sensor, level sensor, Drive mechanism: Electro- mechanical actuator non intrusive type with IP-68protection with manual override wheel integrated with central PLC/SCADA. MOC of all wetted parts including weir, collection trough and arms must be SS 316including suitable size Power, control/signal cables along with tray and all other civil, electrical, mechanical and instrumentation work complete in all respect as per the specifications of DNIT |
| 50 | RAS and SAS pump with VFD: Removal of existing RAS and SAS pumps including all components. Design, supply, Installation, Testing and commissioning of subersible non clog centrifugal pumps for 15MLD average flow along with all components, guide pipe, chain pulley as per existing site conditions including Electro-mechanical actuator non intrusive type with IP-68protection with manual override wheel integrated with central PLC/SCADA, suitable size Power, control/signal cables along with tray and all other civil, electrical, mechanical and instrumentation work complete in all respect as per the specifications of DNIT |
| 51 | DIFFUSER: designing and providing Fine Bubble Membrane Diffuser (Disc). MOC EPDM high grade as per design for 15.00MLD average flow (2SBR Basin). The quantity and disc size will be as per design to maximize surface area and oxygen transfer complete in all respect to the entire satisfaction of Engineer-incharge |
| 52 | Rnovation, Repair, upgradation of installed SCADA/PLC automation system including computer, UPS, terminal blocks, actuators, control and power cables, tray etc. including SCADA Software license key complete in all respect. |
| 53 | Credit for old and removed Lab equipment`s complete in all respect. |
| 54 | Operation and Maintenance of 2Nos STP of 15MLD each based on SBR Technology [with a Total Combined Capacity of 30MLD of Phase-I and Phase-II STPs] at Dadri Road Bhiwani Town, Complete in all respects, including salary and expenses of all type of operating and supervisory staff required for operating of S.T.P., Maintenance of all type of existing Plant and Machinery ,Electric Panel Boards, repair of all type existing Lab Equipment ,civil structure, furniture, I.T. Devices and equipment`s,all electrical and mechanical equipment`s, Cutting of grass and maintenance of Horticulture,Cost of pushing/relaying Online analyzer data and other required data to HSPCB and CPCB servers on 24x7basis in a way/format as desired by HSPCB and CPCB. And Including Preventive Maintenance of all assets of STP including servicing of D.G. Sets. Including Cost of all type of Consumable items, chemicals, reagents,cost of daily sample testing at STP lab along with day to day running of lab and maintaining records as per latest CPCB and HSPCB Norms and Testing of Samples on monthly basis from third party NABL approved Lab as per sampling procedure laid down by BIS/ISO, Complete in all aspect but excluding Cost of Electricity Bills and Cost of Diesel required for running DG sets for STP which will be provided by Department, after request by Contractor 3days in advance anticipating needs of STP. (i) For 1st year during defect liability period after 3 months trial run period |
| 55 | (ii) Operation and Maintenance for 2nd year. |
| 56 | (iii) Operation and Maintenance for 3rd year |
| 57 | (iv) Operation and Maintenance for 4th year |
| 58 | (v) Operation and Maintenance for 5th year. |
| 59 | (vi) Operation and Maintenance for 6th year. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail