| 1 | Material and labour for excavating in trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth for taking out/laying of under ground cable, pole or stay and getting out in soft/loose soil, complete all as specified and as directed. |
| 2 | Returning filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed. NOTE : The top of filled trench shall be made proud by using the excavated soil to cater for subsequent settlement of soil. |
| 3 | Removing excavated materials (soils) not exc 50.00mtr and depositing where directed at a level not exc 1.50 mtr above the starting point in soil, complete all as specified and as directed. |
| 4 | Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine not exceeding 10 mtr in a single length complete all as directed. |
| 5 | Supply and filling for dry sand in cable protection trenches before and after the cables are laid, for sand cushioning to cables complete all as specified and directed. NOTE : thickness after punning of sand shall be (minimum as specified in SSR) measured and paid in this item. |
| 6 | Material and labour for brick protection for UG XLPE cable with burnt clay old size sub class 'B' bricks laid dry and flat abutting each other with gaps between adjacent brick not more than 10mm and width equal to length of brick in trenches across the cable complete all as directed by Engineer-In-Charge.Make: Best quality locally available which is duly approved by GE. |
| 7 | Supply, lay and fix 50 mm bore galvanized iron tubing (light grade) including all fittings and laid in trenches, walls and ceilings or laid in floors complete all as specified and directed.Note: Excavation shall be measured and paid in separate item |
| 8 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured, electric power cables (heavy duty) 1100 Volts grade conforming to IS 7098 with aluminium conductor multi-strand of cross-sectional area 25 Sqmm 4 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. also taking out existing unserviceable UG cables all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 9 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured, electric power cables (heavy duty) 1100 Volts grade conforming to IS 7098 with aluminium conductor multi-strand of cross-sectional area 16 Sqmm 4 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. also taking out existing unserviceable UG cables all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 10 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured, electric power cables (heavy duty) 1100 Volts grade conforming to IS 7098 with aluminium conductor multi-strand of cross-sectional area 10 Sqmm 2 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. also taking out existing unserviceable UG cables all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 11 | Supply and fix as in replacement LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specifed and directed. Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 12 | Supply and fix as in replacement LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specifed and directed. Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 13 | Supply and fix as in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specifed and directed. Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 14 | Supply and fix as in replacement LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specifed and directed. Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 15 | Supply and fix as in replacement LED high mast light 250 watt including connection etc. complete with unique moduar design and scalable solution with IP66 protection ideal for stadium lighting and highmast application complete all as specifed and directed. Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 16 | Supply and fixing PVC insulated and PVC round sheathed, copper conductor (flexible) industrial cable 2.5 sqmm, three core 3 Run and 1.5 sqmm earthing cable in and including through GI tube of light grade of 15mm bore dia for connection of street light on pole / wall from over head conductor / junction box / DB including termination clip etc all as specified including taking down as directed by Engr-in-Charge. |
| 17 | Material and labour for cable junction box with IP 66 protection (halogen free and weather proof) for outdoor installations of size 240 x 130 x 110 mm with terminals including SP MCB of 6 A, gland for cable, FI clamp of size 20x3 mm, nuts, bolts, washers, provision of connectors for connection of cables etc complete or all including taking down as specified or directed. |
| 18 | Supply and fix as in repair MCB SP 240 volts, 50 Hz capacity 6-32 Amps 'C' curve all as specified. |
| 19 | Supply and fixing in replacement Astronomical Street Light time Switch alongwith suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 12 kW load equally distributed over 3-phase .Contactor Rating: 65.Amps (4-pole).MCB (4-pole) Rating: 63.Amps (3 nos.) |
| 20 | Material and labour for preparation of old painted steel surface of LT Poles of height 8.5 / 9 mtrs height of LT OH line or street light steel tubular poles above ground level coping including cross arm channels, flat iron clamp in LT OH line by scrapping with wire brush and applying two coats of aluminium paint including pole numbering all as specified and directed by Engineer-in-Charge. |
| 21 | Supply and fix in replacement analog time switches 1/3 module as per existing make. Please Enable Macros to View BoQ information |
| 22 | Supply and fix in replacement analog time switches 1/3 module as per existing make. Please Enable Macros to View BoQ information |