Tender for Special Repair To Bldg No T-70 Of 5136 Coy Asc (Comp) At Supply Point Averipatti Under Ge 863 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified. |
| 2 | M&L 25mm thick cement concrete type B-O, 1:2:4 (12.5mm graded agg ) as in sub flooring complete all as specified. |
| 3 | M&L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over 20mm thick cement screed bed in CM(1:4) including rubbing and polishing complete all as specified & directed. |
| 4 | M&L 75 mm thick PCC 1:3:6 Type C-2 using 20mm crushed stone aggregate as in plinth protection and finished even and smooth without using extra cement complete all as specified. |
| 5 | Bitumastic filling, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, as in plinth protection complete all as specified & directed. |
| 6 | Demolition of precast concrete articles and precast concrete block walling, built in cement mortar or cement lime mortar for ashlar facings, dressed stonework, complete all as specified and directed by Engr-in-charge. |
| 7 | M&L for block masonry with solid pre-cast cement concrete blocks made out of cement concrete 1: 3: 6 type C-1, using 20 mm graded stone aggregate, any width and setting in cement mortar 1 : 6, complete all as specified and directed by Engr-in-charge. |
| 8 | Dismantling of plain or corrugated steel sheeting, any guage, thickness from roof covering complete all as specified. |
| 9 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 10 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified. |
| 12 | S&F rolled mild steel Fe -290(Gde E-165) for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified. |
| 13 | Dismantling wall and ceiling boards of any description or any thickness including cover fillets as directed. |
| 14 | S&F powder coated GI snap grid of size 605 X 605mm frame work for false ceiling including hangers 2mm dia G.I. (upto 1200mm length) adjusting level fixed to steel member/purlins hangers or roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long whereever required or tie on structural steel complete all as specified and directed.. |
| 15 | S&F Exposed metal frame ceiling with 8mm thick decorative laminated calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mmX600mm grid (frame work for ceiling shall be measured and paid seprately) complete all as specified and directed. |
| 16 | S&F in repairs 19/20 mm dia curtain rails mild steel chromium plated with fixing brackets, stops, roller etc, complete all as specified and directed. |
| 17 | Taking down cement or cement lime plaster any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 18 | M&L 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement (with water proofing compound) complete all as specified and directed. |
| 19 | M&L for 10mm thick rendering in CM (1:6) on internal surfaces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed. |
| 20 | M&L for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over 2 mm thick wall care putty on walls, complete all as specified and directed. |
| 21 | M&L two coats cement base paint on plastered surface including preparation of newly plastered surfaces complete all as specified. |
| 22 | Taking down chowkats or frames(without taking off shutters from the frame) area exc 1.5 Sqm but n.exc 4.0 Sqm each. |
| 23 | S &F 125 x 60mm factory made pressed steel frames conforming to IS, for doors with one or more rebatesmade out of 1.25mm thick mild steerl sheet including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified & directed. |
| 24 | Taking down chowkhats with shutters (without taking off shutters from the frame) and removing from site, area not exceeding 1.5 Sqm each, complete all as specified and directed. |
| 25 | S & F of 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified & directed. |
| 26 | S& F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified. |
| 27 | S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat of red oxide zinc chrome primer, complete all as specified & directed. |
| 28 | S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat of red oxide zinc chrome primer, complete all as specified & directed. |
| 29 | S&F framed work such as framed guard bars, barred iron doors, grills, gratings, etc with ends of bars shouldered or riveted framed guard bars and similar work confirming to Fe-290. Gde E-165 complete all as specified and directed. |
| 30 | S&F 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified. |
| 31 | S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified. |
| 32 | S&F 100mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified. |
| 33 | S & F butt hinges, 100mm medium weight, cold rolled mild steel complete all as specified. |
| 34 | S&F 150 mm Aluminium handles, cast type, anodised complete all as specified and directed. |
| 35 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n,exc 0.5 Sqm, each pane complete all as specified. |
| 36 | S&F in repairs 4 mm thick ordinary quality sheet glass glazing with oil putty and glazing clips fixed complete to wooden/Steel window not exc .5 sqm in each pane including hacking out old broken glass (any thickness, size, quality or description) from metel frame including punching or drilling out old glazing pins/spring clips complete all as specified. |
| 37 | S & F in repair Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples all as specified. |
| 38 | S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm, complete all as specified and directed. |
| 39 | M&L for preparing new or previously untreated surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as spd and directed. |
| 40 | M&L for preparation of old surfaces & applying one coat of oil bound distemper on wall as specified. |
| 41 | M&L one coats of synthetic enamal paint to steel surfaces of any discription not otherwise described over 10cm width or girth preparation of old surfaces complete all as specified. |
| 42 | M & L for preparation of old plastered surfaces of wall including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coat of cement based paint complete all as specified and directed. |
| 43 | M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as spd and directed. |
| 44 | S&F 110 mm bore, PVC (SWR) pipes single socketed/ elbow/ tee, in any length with rubber ring joints, laid in trenches or in floors after dismantling old one complete all as specified. |
| 45 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level). |
| 46 | M & L factory made, precast concrete, machine pressed, interlocking paver block any shape and size, conforming to IS 15658-2006, of 80mm thickness, M-40 Grade, with grey cement and pigment,(in top layer),different colours, laid over complete all as specified and directed. |
| 47 | M & L for 40mm thick fine sand cushioning and joints filled with fine sand, complete all as specified and directed. |
| 48 | M&L for 75 mm thick P.C.C 1:4:8 type B-2 using 40mm graded stone agg as in sub base of floor complete all as specified and as directed. |
| 49 | M & L for PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in copings, bed blocks, etc including necessary form work complete all as specified and directed. |
| 50 | Demolition of precast concrete block walling masonary, built in cement mortar or cement lime mortar incl all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles. |
| 51 | M&L 1:3:6 type C-1 precast cement concrete (20mm graded stone aggregate) block masonary with solid blocks exc 10 cm in width and not exc 20cm in width and setting in cement mortar 1:6. |
| 52 | Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 53 | M&L for PCC 1:2:4 B1 20mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 54 | Extra forming fair finished drain or fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, mould, mitred/stopped ends etc complete all as specified and as directed. |
| 55 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 56 | M&L for point wiring using approved colour coding as per IS by using FRLS PVC insulated 1.5 Sqmm multistranded,1100 volt grade copper conductor cable unsheathed type, alongwith 1.5 Sqmm FRLS PVC insulated stranded copper conductor cable for continous earthing in & incl casing capping point wiring with accessories having ISI mark for one light/fan/bell point/5 amp indep/power point/same board controlled by one switch complete all as specified and directed. |
| 57 | All as per item No 56 here-in-before but for one multipin socket outlet 5 Amp but using 2x 1.5 + 1 x 1.5 sqmm multistranded FRLS copper cable on the independent board. |
| 58 | All as per item No 56 here-in-before but for one multipin socket outlet 5 Amp on the same board with other switches. |
| 59 | All as per item No 56 here-in-before but for one multipin socket outlet 15 Amp, but using 2 x2.5 +1 x 2.5 sqmm multistranded FRLS copper cable, independent board. |
| 60 | All as per item No 56 here-in-before but for single pole and neutral enclosure with a two pin plug and socket, but using 2 x4.0 +1 x 4.0 sqmm multistranded FRLS copper cable, independent board |
| 61 | S&F in replacement of switch piano type 5 Amp, 230 Volt, flush type single pole one way complete all as specified and directed. |
| 62 | S&F in replacement of socket outlet multipin 5 Amp 230 Volt flush type complete all as specified and directed. |
| 63 | S&F in replacement of switch piano type 15 Amp, 230 Volt, flush type single pole one way complete all as specified and directed. |
| 64 | S&F in replacement of socket outlet multi pin 15 Amp 230 Volt flush type complete all as specified and directed. |
| 65 | S&F In replacement of for Lamp holder, PVC/Polycarbonate type with back plate suitable for Angle/batten fittings complete all as specified and directed |
| 66 | S&F of rechargeable led bulb minimum 4 Hrs Battery backup 9 Watt B-22 Base complete all as specified and directed. |
| 67 | S&F in rplacement of Ceiling rose, 3 terminal, PVC isolated body complete all as specified and directed |
| 68 | S&F in replacement of LED light fitting 20W, 220 volt AC, having colour temperature daylight (6500K), Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 69 | S&F single pole and neutral enclosure with a two pin plug and socket complete with one single pole MCB 32 Amp complete all as specified and directed. |
| 70 | S&F in replacement LED light fitting 1x10W/1X12W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 71 | Supply and fixing of exhaust fan, steel body AC single Phase 230V of size 450m sweep heavy duty with, blades, and frame and louvers complete all as specified and directed. |
| 72 | S&F including flushing in wall MCB distribution board vertical TPN 4 way 415 volt AC double door sheet with bus bar neutral earth bar including provision of MCB TPN 63 amp conforming to IP 43 as incomer complete all as specified and directed. |
| 73 | S&F MCB TPN 63 amp 415 volt with bearing capacity of 16 KA complete all as sp[ecified and directed. |
| 74 | S&F in replacement of sheet metal enclosure double door distribution board single pole and neutral, 12 way 240 volt with 200 amps rated bus bar complete with bus and neutral link complete all as specified and directed. |
| 75 | S&F in replacement of MCB 6 to 32 amp rating 240V, 10KA 'B' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 76 | S&F in replacement of MCB SPN 40 amp2 amp rating 240V, 10KA 'B' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 77 | Supply & laying LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 16 sqmm 4 core as per IS specification laid through GI pipe/on floor/wall complete all as specified and directed |
| 78 | Supply and laying of GI pipe light galvanized with all fitting laid in trenches for cable proctection of 50 mm bore all as specified and directed. |
| 79 | M&L in replacement of Earthing complete with galvanised steel earth plate electrode 600×600×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as directed. |
| 80 | Supply and fixing Building LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed. |
| 81 | Supply, laying and drawing in and including 20 mm dia casing caping including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed. |
| 82 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/dense soil for laying / taking up/ taking down of cables and getting out and leveling of bottom surface to required level all as specified and directed by Engineer- in- Charge. |
| 83 | Returning filling in,. Including spreading, leveling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. |
| 84 | Removing excavated material (i.e. soil) from site to a distance n. exec 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge. |
| 85 | Supply and fixing ceiling fans complete with blades, down rods, remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 86 | S&F for fixing of GI pipe (light grade) bracket of 40mm dia size of 1.2 mtr long bent to shape for fixing of LED street light fittings and fixing to pole, walls etc including fixing of clamp, nut, bolt etc as specified and directed. |
| 87 | S&F of double wall corrugated HDPE duct pipe of 50 mm outer dia PN 10 of approved colour with fittings for cable protection complete all as directed. |
| 88 | Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender