Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56009528

Tender For Construction Of Phase-B (Balance) Works At Jnv Harda (M.P.)

Issued by Government Departments · Harda, Madhya Pradesh
Tender Value
4.81 Crore
Estimated cost
Bid Submission
07 Jul 2026
6 days left
EMD
9.64 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Harda → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Phase-B (Balance) Works At Jnv Harda (M.P.)

BOQ

Name of Work:- Construction of Phase-B (Balance) works at JNV Harda (M.P.)
Sl. No. Item Description
1Discription of work
2GIRL'S DORMITORY (72 BEDS) WITH 1 NOS. WARDEN RESIDENCE (G+1)
3Earth Work
4Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
6Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
7Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
8Concrete Work
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
10Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
11Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
12Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth.
13Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
14Reinforced Cement Concrete
15Centering and shuttering including strutting, propping etc. and removal of form for all heights :
16Foundations, footings, bases of columns, etc. for mass concrete.
17Suspended floors, roofs, landings, balconies and access platform.
18Lintels, beams, plinth beams, girders, bressumers
19Columns,Pillars, Piers, Abutments, Posts and Struts.
20Edges of slabs and breaks in floors and walls Under 20 cm wide.
21Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
22Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
23Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
24Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
25All works upto plinth level
26Concrete of M25 grade with minimum cementcontent of 330 kg /cum
27(i) R.C.C. work in Footing
28(ii) R.C.C. work in Beam
29(iii) R.C.C. work in Columns
30All works above plinth level upto floor V level
31Concrete of M25 grade with minimum cementcontent of 330 kg /cum
32(i) R.C.C. work in Lintel
33(ii) R.C.C. work in Beam
34(iii) R.C.C. work in Columns
35(iv) R.C.C. work in Slab
36Expansion Joint Treatment
37Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that commodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063).
38Floor Joint of 100 mm gap
39Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).
40Wall Joint of 100 mm gap
41Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed toaccommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement.(Material shall confirm to ASTM 6063.)
42Roof Joint of 100 mm gap
43Masonry Work
44Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
45Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
46Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in superstructure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 coarse sand)
47Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
48Cladding Work
49Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
50Granite stone slab colour black, Cherry/Ruby red
51Area of slab upto 0.50 sqm
52Area of slab over 0.50 sqm
53Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
54Granite work
55Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
56Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
57Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
58Wood and PVC Work
59Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
60Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
61Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
62Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
63Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper
64Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size Kiln seasoned and chemically treated hollock wood
65Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm.
66Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
67Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.
68200 x 10mm
69150 x 10mm
70CUPBOARD / WARDROBE
71Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid board one side white color and otherside of board laminted with PVC foil of minimum 14 micronthickness of approved design pasted with hot melt adhesivefor cup boards, work stations and bathroom/kitchen cabinetetc. of required sizes comprising of virgin polymer of K value58-60 (Suspension Grade), calcium carbonate and natural fibers(wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimumdensity of 650 kg/cum and screw withdrawal strength of 1800N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spreadof flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixingwith stainless steel piano hinges/soft close clip on concealedhinges of required size with necessary full body threaded starheaded counter sunk S.S screws, all as per direction ofEngineer-In- Charge. (Note: stainless steel piano hinges/softclose clip on concealed hinges and necessary S.S screws shallbe paid separately)
7218 mm thick
7325 mm thick
74Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain white color board for backingof cup boards and bathroom/kitchen cabinets etc. of requiredsize comprising of virgin polymer of K value 58-60 (SuspensionGrade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumtoxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) &900 N (Edge), minimum compressive strength 50 N/mm2,modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class A category with property of being termite/borerproof, water/moisture proof and fire retardant and fixing withstainless steel screws etc. all as per direction of Engineer-In-Charge. (Note: stainless steel screws shall be paid separately)
756 mm thick
76Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 200 mm
77Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction ofEngineer-in-charge. 100 mm for Kitchen Cabinets
78Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand tocupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete asper direction of Engineer-in-charge
79Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge.
80Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket,Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge.(For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc.Payment of providing and fixing telescopic channel shall be paid separately)
81SS Hanging Rod for CB
82Providing and fixing 25 mm dia. SS pipe Hanging rods with SS brackets :
83Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work
84Steel Work
85Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
86Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
87Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.
88ALUMINIUM WORK
89System Aluminium Factory made Double Rebate Windows with Grill and MeshProviding and fixing of A2Z Series Double rebate windows & ventilators made of High-performance factory-made system Aluminium windows with Akzonobel powder coating of 60-70 microns (Any RAL Colour). Section for Outer frame should be a single section of 91mm x 35mm, Glass shutter frame shall be of 54mm x 30mm, Mesh shutter frame shall be of 54mm x 30mm, 5mm thick Single Glazed beading shall be of 15mm x 18mm. 5mm thick Clear Tuffened Glass shall be used in all the windows & ventilators. Stainless Steel Wire Mesh shall be used in Wire mesh Shutters. No Coupling of 2 windows shall be allowed in any type of design. 10mm Sq bar M.S. Grill/Guard bar with 150mm c/c shall be fixed in between glass & mesh shutter. All frame corners shall be joined/assembled using self-locating corner cleats (No screwing at corners shall be allowed). All Hardware shall be used from a reputed brand, weather silicon shall be used for filling the gap between window opening & window Frame complete in all respect including all taxes.
90Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
91For fixed portion
92Powder coated aluminium (minimum thickness of powder coating 50 micron
93For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
94Powder coated aluminium (minimum thickness of powder coating 50 micron)
95Providing and fixing 12 mm thick prelaminated particle board flatpressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screwsetc. complete as per architectural drawings and directions of engineerin-charge.
96Pre-laminated particle board with decorative laminationon both sides
97Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
98With float glass panes of 8 mm thickness (weight notless than 20 kg/sqm)
99Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor f nishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in-charge. With stainless steel cover plate minimum 1.25 mm thickness
100Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
101Upto 5mm depth and 5 mm width
102Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
103Flooring
104Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement
105Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
106Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
107Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
108Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
109Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
110Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well a curvilinear portions of the building all complete as per the architecturaldrawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
111Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
112Providing and fixing machine cut, mirror/ eggshell polished , granite work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charg .Granite of all colour except black, cherry/ruby red 18 mm thick (slab area above 0.50 sqm)
113Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main\\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main\\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of allT-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
11412.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardantPVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back sidemetalized polyester film so as to make the tile a completely sealed unit.
115Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
116Finishing
117External Plaster in CM 1:4 with18mm thick in Two coats comprising of first layer 12mm thick cement plaster finished with a top layer 6mm thick cement plaster cement: 4 coarse sand)
118Rate for First layer 12mm thick cement plaster DSR item No. 13.4.1=Rs. 357.35
119Rate for top layer 6mm thick cement plaster cement DSR item No. 13.4.1=Rs. 357.35/2=153.63
120Total Rate For 18mm Thick Plaster=357.35+178.68=536.03
121Extra for providing and mixing water proofing material in cement of plaster work in proportion recommended by the manufacturers.
12212mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand)
1236 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand)
124Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
125Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
126Steel Painting:Applying priming coat:
127With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
128With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
129Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
130Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
131Water Proofing
132Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
133(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
134(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
135(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
136(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
137(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
138With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
139PLUMBING ESTIMATE ( 0.375 GIRLS DORM. 72 BEDDED )
140SUB HEAD - I : SANITARY FIXTURES ( PROVIDING AND FIXING )
141Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
142White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
143Providing and Fixing White Viterous China Extended wall mounting water closet of size 780 x 370 x 690 mm of approved shape including providing and fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litre ) including seat cover and cistern fittings nuts bolts and gaskets etc complete .
144Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid
145Providing and fixing wash basin with C.I. brackets 15 mm dia CP brass single hole basin mixer of approved quality and make including painting of fittings and brackets cutting and making good the walls wherever required
146White Viterous china Wash basin size 550x400 mm with a 15 mm CP brass single hole basin mixer
147Providing and Fixing Stainless Steel A ISI 304 ( 18/8 ) kitchen sink as per IS : 13983 with CI Brackets and stainless steel plug 40 mm , including painting of fittings and brackets , cutting and making good the walls wherever required .
148Kitchen Sink with drain board
149510 x 1040 mm bowl depth 250 mm
150Providing and Fixing CP brass bib cock of approved quality conforming to IS : 8931
15115 mm nominal bore
152Providing and Fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms .
15315 mm nominal bore
154Providing and Fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS : 8931
15515 mm nominal bore
156Providing and Fixing CP brass stop cock ( concealed ) of standard design and of approved make conforming to IS : 8931
15715 mm nominal bore
158Providing and placing on terrace ( at all floor levels ) polythylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for tank .
159Providing & fixing of Waste pipe for Wash basins & Sinks including pvc waste fittings complete.
16032 mm dia
16140 mm dia
162Providing & fixing PTMT liquid soap container 109mm wide,125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
163Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
164Providing & fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P brass screws with concealed fitting arangement of approved quality and colour.
165600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gram.less
166Providing & fixing PTMT soap dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements.Weighing not less than 106gms.
167Providing & fixing 600 x 450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass Screws and washers complete .
168Providing & fixing toilet paper holder:
169C.P.brass
170Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
17115 mm nominal bore with 45cm length
172Providing and fixing CP brass shower rose with 15 or 20 mm inlet
173100 mm diameter
174Providing & Fixing CP brass single lever telephonic wall mixer of quality and make as approved by engineer - in - charge .
17515 mm nominal dia
176Providing and Fixing White Viterous China battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption ) , having water inlet from back side , including fixing to wall with suitable brackets all as per manufacturer specification and direction of engineer - in - charge .
177Providing & fixing C.P. brass Central hole wall mounted sink Mixer with aerator connecting legs & 2 nos CP brass wall flange and 2 nos CP brass stop cock including cutting & making good the walls wherever required complete in all respect as per direction of engineer - in - charge .
178Providing and fixing C.P. brass Double coat hooks fixed in Toilet wall with C.P brass wall flanges & C.P. brass screws and other required accessories complete in all respect as per direction of engineer - in - charge .
179Providing and fixing health faucet with 1 m CP brass flexible tube and swivel hook with CP brass wall flange including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge .
180Providing and fixing vertical or horizontal storage type hot water heater electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug .
18115 Litre Capacity
18225 Litre Capacity
183SUB HEAD - II : INTERNAL DRAINAGE (RAINWATER, SOIL, WASTE & FITTINGS)
184Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
185Providing and Fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams .
186Providing and Fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 Cement : 4 Fine Sand )
187Stone ware Spout
188Providing and Fixing on wall face Unplasticised rigid pvc rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
189Single Socketed Pipes
19075 mm diameter
191110 mm diameter
192Providing and Fixing on wall face Rigid Unplasticised UPVC moulded fittings / accessories for unplasticised Rigid PVC Rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
193Coupler
19475 mm diameter
195110 mm diameter
196Single Push Fit Coupler
19775 mm diameter
198110 mm diameter
199Single Tee with door
20075x75x75 mm
201110x110x110 mm
202Single Tee without door
20375x75x75 mm
204110x110x110 mm
205Bend 87.5 degree
20675 mm bend
207110 mm bend
208Shoe ( Plain )
20975 mm Shoe
210110 mm Shoe
211Providing and Fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs , screwed with MS screws of required length , including cutting brick work with fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse Sand ) and making good the wall etc . complete
21275 mm diameter
213110 mm diameter
214Providing and Fixing Soil , Waste and Vent Pipes :
215100 mm dia
216Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
21775 mm dia
218Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
219Providing and Filling the joints with spun yarn , cement slurry and cement mortar 1 : 2 ( 1 Cement : 2 fine Sand ) in SCI / CI Pipes :
22075 mm dia Pipe
221100 mm dia Pipe
222Providing and Fixing MS holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of cement concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 graded stone aggregate 20 mm nominal sizes ) including cost of cutting holes and making good the walls etc .
223For 100 mm dia Pipe
224For 75 mm dia Pipe
225Providing and Fixing Bend of Required degree with access door , insertion rubber washers 3 mm thick , bolts and nuts complete .
226100 mm dia
227Sand Cast iron S & S as per IS : 3989
228Providing and Fixing Plain Bend of Required degree .
229100 mm dia
230Sand Cast iron S & S as per IS : 3989
231Providing and Fixing Heel Rest Sanitary Bend
232100 mm dia
233Spun Cast Iron as per IS : 3989
234Providing and Fixing Double Equal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
235100x100x100x100 mm
236Spun Cast Iron as per IS : 3989
23775x75x75x75 mm
238Spun Cast Iron as per IS : 3989
239Providing and Fixing Single Equal Plain Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
240100x100x100 mm
241Sand Cast Iron S&S as per IS : 3989
24275x75x75 mm
243Sand Cast Iron S&S as per IS : 3989
244Providing and Fixing Single Unequal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
245100 x 100 x 75 mm
246Sand Cast Iron S & S as per IS : 3989
247Providing and Fixing Single Unequal Plain Junction of Required degree .
248100 x 100 x 75 mm
249Sand Cast Iron S & S as per IS : 3989
250Providing and Fixing Sand Cast Iron S & S offsets as per IS : 3989
251150 mm off sets
252With 75 mm dia Pipe
253With 100 mm dia Pipe
254Providing and Fixing door piece , insertion rubber washer 3 mm thick , bolts and nuts complete .
255100 mm
256Spun Cast Iron as per IS : 3989
25775 mm
258Spun Cast Iron as per IS : 3989
259Providing and Fixing Terminal Guard :
260100 mm
261Sand Cast Iron S & S as per IS : 3989
26275 mm
263Sand Cast Iron S & S as per IS : 3989
264Providing and Fixing Collar :
265100 mm
266Sand Cast Iron S & S as per IS : 3989
26775 mm
268Sand Cast Iron S & S as per IS : 3989
269Providing Lead Caulked Joints to Sand Cast iron / centrifugally cast spun iron pipes and fittings of diameter :
270100 mm dia pipe
27175 mm dia pipe
272Providing and Fixing MS Stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter :
273100 mm dia pipe
27475 mm dia pipe
275Providing and Fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete , including cost of cutting and making good the walls and floors .
276100 mm inlet and 100 mm outlet
277Sand Cast Iron S & S as per IS : 3989
278Painting Sand cast iron / centrifugally cast ( spun ) iron soil , waste , vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey , or buff etc . Over a coat of primer ( of approved quality ) for new work :
279100 mm diameter Pipes
28075 mm diameter Pipes
281Providing and Fixing GI Pipes complete with GI Fittings and clamps including cutting and making good the walls etc .
282Internal Work - Exposed on Wall
28332 mm dia nominal bore
28440 mm dia nominal bore
28550 mm dia nominal bore
286Painting GI Pipes and Fittings with Synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work :
28732 mm diameter pipe
28840 mm diameter pipe
28950 mm diameter pipe
290Providing and fixing multi-floor trap fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes heavy duty and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete in all respect as directed by Engineer-in-charge.
291Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe complete in all respect as directed by Engineer-in-charge.
292Providing and fixing CP Brass floor cleanout plug / Clean out plug as per drawing complete with G.I. Socket jointed to drainage pipe outlet including drip seal joint complete in all respect as directed by Engineer-in-charge.
293100 mm diameter Pipe
294150 mm diameter Pipe
295Providing and fixing Stainless Steel Grade (304) grating with ring and Stainless steel anti cockroach basket and two SS screw including fixing to the floor with cement mortar.
296SUB HEAD - III : INTERNAL WATER SUPPLY
297Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc
29815 mm dia pipes
29920 mm dia pipes
30025 mm dia pipes
30132 mm dia pipes
30240 mm dia pipes
30350 mm dia pipes
304Painting GI Pipes & Fittings with synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work .
30515 mm dia pipes
30620 mm dia pipes
30725 mm dia pipes
30832 mm dia pipes
30940 mm dia pipes
31050 mm dia pipes
311Providing and Fixing GI Union in GI Pipe including cutting and threading the pipe and making long screws etc . Complete ( New Work )
31215 mm dia pipes
31320 mm dia pipes
31425 mm dia pipes
31532 mm dia pipes
31640 mm dia pipes
31750 mm dia pipes
31865 mm dia pipes
31980 mm dia pipes
320Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makin good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.)
32115 mm dia pipes
32220 mm dia pipes
32325 mm dia .Pipes.
32432 mm dia .Pipes.
325Providing and fixing Thermoflex or Careflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification.
3269 mm thick ( Pipe Inside the Toilets and Exposed in Shafts and Terrace )
327For 15 mm dia Pipe
328For 20 mm dia Pipe
329For 25 mm dia Pipe
330For 32 mm dia Pipe
331For 40 mm dia Pipe
332For 50 mm dia Pipe
333Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc.
33440 mm dia Pipe
33550 mm dia Pipe
336Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
33715 mm dia
33820 mm dia
33925 mm dia
34032 mm dia
34140 mm dia
34250 mm dia
343INTERNAL ELECTRICAL WORK ( 0.375 GIRLS DORM. 72 BEDDED )
344SUB HEAD - I: CIRCUIT CUM POINT WIRING
345SWITCH CONTROL LIGHT POINTS
346Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. .
347Group A
348Group B
349Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
350Group A
351Group B
352MCB CONTROL LIGHT POINTS
353Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points)
354Primary point controlled by one MCB.
355Same as item above but Secondary point. i.e. Points to be looped with Primary point with 1.5 sqmm wire and Point wiring
356Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
3572 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3582 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3592 X 4 sq. mm + 1 X 4 sq. mm earth wire
3602 X 6 sq. mm + 1 X 6 sq. mm earth wire
3612 x 10 sq. mm + 1 x 6 sq.mm earth wire
3624 X 10 sq. mm + 2 X 6 sq. mm earth wire
3634 X 16 sq. mm + 2 X 6 sq. mm earth wire
364Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required.
365Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required.
366Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
367Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (AC's & Gysers)
368Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
369Telephone socket outlet
370TV antenna socket outlet
371Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3721 or 2 Module (75mmX75mm)
3736 module (78mm X 205 mm X 50 mm)
374Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3753 pin , 5/6 amps socket outlet
3765/6 amps switch
377Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
37825 mm
37932 mm
380SUBHEAD -II - FITTINGS & FIXTURES
381Supply, Installation, Testing and Commissioning of 10 W Bulk head Light.
382Supply, Installation, Testing and Commissioning of 5W Mirror Light.
383Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
3848-10 Watt
38512-15 Watt
38618 Watt
387Supplying, installation, Testing & Commissioning of LED (surface/wall) mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq. 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Batten light (System lumen efficacy >135 lm/Watt)
38818-22 Watt
389Supply, Installation, Testing and Commissioning of 10W (Nominal) Wall Bracket Light
390Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
3911200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
392Supply, installation, Testing and commissioning of 250mm Exhaust fan.
393Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
394SUBHEAD - III - DISTRIBUTION BOARDS
395Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
3966 way, Double door
3978 way, Double door
39812 way, Double door
399Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
4006 way (4 + 18), Double door
4018 way (4 + 24), Double door
402Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
403Single Pole
404Single Pole Neutral
405Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
406Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
407Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
408Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
409SUB HEAD -IV - LT CABLES & CABLE TRAYS
410Laying of one number PVC Insulated and PVC shethed /XLPE power Cables of 1.1 KV grade of following size direct in ground including excavation,sand cushioning and protecting covering and refilling the trench etc as required.
411Up to 35 sq mm.
412Above 35 sq mm and up to 95 sq mm.
413Above 95 sq mm and up to 185 sq mm.
414Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
415Upto 35 sq.mm
416Above 35 sq. mm and upto 95 sq. mm
417Above 95 sq.mm and upto 185 sq.mm
418S/ F powder coated of approved shade MS Cable Trays
419Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required..
420100 mm width X 50 mm depth X 1.6 mm thickness
421150 mm width X 50 mm depth X 1.6 mm thickness
422300 mm width X 50 mm depth X 1.6 mm thickness
423S/ F powder coated of approved shade MS Cable Tray Bends
424Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
425100 mm width X 50 mm depth X 1.6 mm thickness
426150 mm width X 50 mm depth X 1.6 mm thickness
427S/ F powder coated of approved shade MS Cable Tray Tee's
428Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
429100 mm width X 50 mm depth X 1.6 mm thickness
430150 mm width X 50 mm depth X 1.6 mm thickness
431Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
4324 X 10 sq. mm (28mm)
4334 X 16 sq. mm (28mm)
4343½ X 35 sq. mm (32mm)
4353½ X 50 sq. mm (35mm)
4363½ X 95 sq. mm (38mm)
4373½ X 120 sq. mm (38mm)
438XLPE Insulated Copper Armoured Cables
4392C x 6 Sq.mm.
4402C x 4 Sq.mm.
4413C x 6 Sq.mm.
4423C x 4 Sq.mm.
4434CX 2.5 Sq.mm
4444C x 4 Sq.mm.
445Supply and making End termination with brass Single/ Double compression gland including providing and crimping of aluminum/copper solderless lugs/ferrules for XLPE/PVC insulated armoured power aluminum/copper conductor cables 1.1 KV grade of following sizes:
446SINGLE COMPRESSION GLAND FOR AI. AR. CABLE
4474C/3C x 6/4 sq.mm.
448Single Compression Gland for Cu. Cable
4494C/3C/2C x 4/6/2.5 sq.mm.
450Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.
4514 X 10 sq. mm (25mm)
4524 X 16 sq. mm (28mm)
4533½ X 25 sq. mm (28mm)
4543½ X 35 sq. mm (32mm)
4553½ X 50 sq. mm (35mm)
4563½ X 95 sq. mm (45mm)
4573½ X 120 sq. mm (45mm)
458SUB HEAD -V - EARTHING SYSTEM
459Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
460Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
461Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
462Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
463SUB HEAD - VI :LIGHTNING CONDUCTOR
464Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including accesssories, and providing masonary enclosure with cover plate (CI heavy duty) having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required.
465Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
466Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
467Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
468Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
469Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
470Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
471Supply of Lightnig counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, meet the requirements for IS/IEC 62305 and IEC 62561-2.Tested for Electrical ,Mechanical and Chemical as per IEC 62561.
472BOYS DORMITORY (24 BEDS) WITH 1 NOS. WARDEN RESIDENCE (G)
473Earth Work
474Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
475Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
476Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
477Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
478Concrete Work
479Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
480Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
481Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
482Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth.
483Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
484Reinforced Cement Concrete
485Centering and shuttering including strutting, propping etc. and removal of form for all heights :
486Foundations, footings, bases of columns, etc. for mass concrete.
487Suspended floors, roofs, landings, balconies and access platform.
488Lintels, beams, plinth beams, girders, bressumers
489Columns,Pillars, Piers, Abutments, Posts and Struts.
490Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
491Edges of slabs and breaks in floors and walls Under 20 cm wide.
492Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
493Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
494Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
495Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
496All works upto plinth level
497Concrete of M25 grade with minimum cementcontent of 330 kg /cum
498(i) R.C.C. work in Footing
499(ii) R.C.C. work in Beam
500(iii) R.C.C. work in Columns
501All works above plinth level upto floor V level
502Concrete of M25 grade with minimum cementcontent of 330 kg /cum
503(i) R.C.C. work in Lintel
504(ii) R.C.C. work in Beam
505(iii) R.C.C. work in Columns
506(iv) R.C.C. work in Slab
507Masonry Work
508Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
509Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
510Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in superstructure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 coarse sand)
511Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
512Cladding Work
513Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
514Granite stone slab colour black, Cherry/Ruby red
515Area of slab upto 0.50 sqm
516Area of slab over 0.50 sqm
517Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
518Granite work
519Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
520Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
521Providing and fixing Ist quality Glazed vitrified tiles polished finish ofsize 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
522Wood and PVC Work
523Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
524Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
525Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
526Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
527Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper
528Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size Kiln seasoned and chemically treated hollock wood
529Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm.
530Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
531Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.
532200 x 10mm
533150 x 10mm
534CUPBOARD / WARDROBE
535Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid board one side white color and otherside of board laminted with PVC foil of minimum 14 micronthickness of approved design pasted with hot melt adhesivefor cup boards, work stations and bathroom/kitchen cabinetetc. of required sizes comprising of virgin polymer of K value58-60 (Suspension Grade), calcium carbonate and natural fibers(wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimumdensity of 650 kg/cum and screw withdrawal strength of 1800N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spreadof flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixingwith stainless steel piano hinges/soft close clip on concealedhinges of required size with necessary full body threaded starheaded counter sunk S.S screws, all as per direction ofEngineer-In- Charge. (Note: stainless steel piano hinges/softclose clip on concealed hinges and necessary S.S screws shallbe paid separately)
53618 mm thick
53725 mm thick
538Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain white color board for backingof cup boards and bathroom/kitchen cabinets etc. of requiredsize comprising of virgin polymer of K value 58-60 (SuspensionGrade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumtoxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) &900 N (Edge), minimum compressive strength 50 N/mm2,modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class A category with property of being termite/borerproof, water/moisture proof and fire retardant and fixing withstainless steel screws etc. all as per direction of Engineer-In-Charge. (Note: stainless steel screws shall be paid separately)
5396 mm thick
540Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 200 mm
541Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction ofEngineer-in-charge. 100 mm for Kitchen Cabinets
542Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand tocupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete asper direction of Engineer-in-charge
543Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge.
544Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket,Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge.(For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc.Payment of providing and fixing telescopic channel shall be paid separately)
545SS Hanging Rod for CB
546Providing and fixing 25 mm dia. SS pipe Hanging rods with SS brackets :
547Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work
548Steel Work
549Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
550Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
551Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.
552ALUMINIUM WORK
553System Aluminium Factory made Double Rebate Windows with Grill and MeshProviding and fixing of A2Z Series Double rebate windows & ventilators made of High-performance factory-made system Aluminium windows with Akzonobel powder coating of 60-70 microns (Any RAL Colour). Section for Outer frame should be a single section of 91mm x 35mm, Glass shutter frame shall be of 54mm x 30mm, Mesh shutter frame shall be of 54mm x 30mm, 5mm thick Single Glazed beading shall be of 15mm x 18mm. 5mm thick Clear Tuffened Glass shall be used in all the windows & ventilators. Stainless Steel Wire Mesh shall be used in Wire mesh Shutters. No Coupling of 2 windows shall be allowed in any type of design. 10mm Sq bar M.S. Grill/Guard bar with 150mm c/c shall be fixed in between glass & mesh shutter. All frame corners shall be joined/assembled using self-locating corner cleats (No screwing at corners shall be allowed). All Hardware shall be used from a reputed brand, weather silicon shall be used for filling the gap between window opening & window Frame complete in all respect including all taxes.
554Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
555For fixed portion
556Powder coated aluminium (minimum thickness of powder coating 50 micron
557For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
558Powder coated aluminium (minimum thickness of powder coating 50 micron)
559Providing and fixing 12 mm thick prelaminated particle board flatpressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screwsetc. complete as per architectural drawings and directions of engineerin-charge.
560Pre-laminated particle board with decorative laminationon both sides
561Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
562With float glass panes of 8 mm thickness (weight notless than 20 kg/sqm)
563Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor f nishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in-charge. With stainless steel cover plate minimum 1.25 mm thickness
564Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
565Upto 5mm depth and 5 mm width
566Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
567Flooring
568Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement
569Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
570Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
571Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
572Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
573Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
574Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well a curvilinear portions of the building all complete as per the architecturaldrawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
575Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
576Providing and fixing machine cut, mirror/ eggshell polished , granite work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charg .Granite of all colour except black, cherry/ruby red 18 mm thick (slab area above 0.50 sqm)
577Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main\\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main\\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of allT-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
57812.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardantPVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back sidemetalized polyester film so as to make the tile a completely sealed unit.
579Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
580Finishing
581External Plaster in CM 1:4 with18mm thick in Two coats comprising of first layer 12mm thick cement plaster finished with a top layer 6mm thick cement plaster cement: 4 coarse sand)
582Rate for First layer 12mm thick cement plaster DSR item No. 13.4.1=Rs. 357.35
583Rate for top layer 6mm thick cement plaster cement DSR item No. 13.4.1=Rs. 357.35/2=153.63
584Total Rate For 18mm Thick Plaster=357.35+178.68=536.03
585Extra for providing and mixing water proofing material in cement of plaster work in proportion recommended by the manufacturers.
58612mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand)
5876 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand)
588Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
589Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
590Steel Painting:Applying priming coat:
591With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
592With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
593Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
594Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
595Water Proofing
596Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
597(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
598(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
599(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
600(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
601(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
602With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
603PLUMBING ESTIMATE ( 0.125 BOYS DORM. 24 BEDDED )
604SUB HEAD - I : SANITARY FIXTURES ( PROVIDING AND FIXING )
605Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
606White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
607Providing and Fixing White Viterous China Extended wall mounting water closet of size 780 x 370 x 690 mm of approved shape including providing and fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litre ) including seat cover and cistern fittings nuts bolts and gaskets etc complete .
608Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid
609Providing and fixing wash basin with C.I. brackets 15 mm dia CP brass single hole basin mixer of approved quality and make including painting of fittings and brackets cutting and making good the walls wherever required
610White Viterous china Wash basin size 550x400 mm with a 15 mm CP brass single hole basin mixer
611Providing and Fixing Stainless Steel A ISI 304 ( 18/8 ) kitchen sink as per IS : 13983 with CI Brackets and stainless steel plug 40 mm , including painting of fittings and brackets , cutting and making good the walls wherever required .
612Kitchen Sink with drain board
613510 x 1040 mm bowl depth 250 mm
614Providing and Fixing CP brass bib cock of approved quality conforming to IS : 8931
61515 mm nominal bore
616Providing and Fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms .
61715 mm nominal bore
618Providing and Fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS : 8931
61915 mm nominal bore
620Providing and Fixing CP brass stop cock ( concealed ) of standard design and of approved make conforming to IS : 8931
62115 mm nominal bore
622Providing and placing on terrace ( at all floor levels ) polythylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for tank .
623Providing & fixing of Waste pipe for Wash basins & Sinks including pvc waste fittings complete.
62432 mm dia
62540 mm dia
626Providing & fixing PTMT liquid soap container 109mm wide,125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
627Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
628Providing & fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P brass screws with concealed fitting arangement of approved quality and colour.
629600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gram.less
630Providing & fixing PTMT soap dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements.Weighing not less than 106gms.
631Providing & fixing 600 x 450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass Screws and washers complete .
632Providing & fixing toilet paper holder:
633C.P.brass
634Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
63515 mm nominal bore with 45cm length
636Providing and fixing CP brass shower rose with 15 or 20 mm inlet
637100 mm diameter
638Providing & Fixing CP brass single lever telephonic wall mixer of quality and make as approved by engineer - in - charge .
63915 mm nominal dia
640Providing and Fixing White Viterous China battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption ) , having water inlet from back side , including fixing to wall with suitable brackets all as per manufacturer specification and direction of engineer - in - charge .
641Providing & fixing C.P. brass Central hole wall mounted sink Mixer with aerator connecting legs & 2 nos CP brass wall flange and 2 nos CP brass stop cock including cutting & making good the walls wherever required complete in all respect as per direction of engineer - in - charge .
642Providing and fixing C.P. brass Double coat hooks fixed in Toilet wall with C.P brass wall flanges & C.P. brass screws and other required accessories complete in all respect as per direction of engineer - in - charge .
643Providing and fixing health faucet with 1 m CP brass flexible tube and swivel hook with CP brass wall flange including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge .
644Providing and fixing vertical or horizontal storage type hot water heater electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug .
64515 Litre Capacity
64625 Litre Capacity
647SUB HEAD - II : INTERNAL DRAINAGE (RAINWATER, SOIL, WASTE & FITTINGS)
648Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
649Providing and Fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams .
650Providing and Fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 Cement : 4 Fine Sand )
651Stone ware Spout
652Providing and Fixing on wall face Unplasticised rigid pvc rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
653Single Socketed Pipes
65475 mm diameter
655110 mm diameter
656Providing and Fixing on wall face Rigid Unplasticised UPVC moulded fittings / accessories for unplasticised Rigid PVC Rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
657Coupler
65875 mm diameter
659110 mm diameter
660Single Push Fit Coupler
66175 mm diameter
662110 mm diameter
663Single Tee with door
66475x75x75 mm
665110x110x110 mm
666Single Tee without door
66775x75x75 mm
668110x110x110 mm
669Bend 87.5 degree
67075 mm bend
671110 mm bend
672Shoe ( Plain )
67375 mm Shoe
674110 mm Shoe
675Providing and Fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs , screwed with MS screws of required length , including cutting brick work with fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse Sand ) and making good the wall etc . complete
67675 mm diameter
677110 mm diameter
678Providing and Fixing Soil , Waste and Vent Pipes :
679100 mm dia
680Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
68175 mm dia
682Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
683Providing and Filling the joints with spun yarn , cement slurry and cement mortar 1 : 2 ( 1 Cement : 2 fine Sand ) in SCI / CI Pipes :
68475 mm dia Pipe
685100 mm dia Pipe
686Providing and Fixing MS holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of cement concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 graded stone aggregate 20 mm nominal sizes ) including cost of cutting holes and making good the walls etc .
687For 100 mm dia Pipe
688For 75 mm dia Pipe
689Providing and Fixing Bend of Required degree with access door , insertion rubber washers 3 mm thick , bolts and nuts complete .
690100 mm dia
691Sand Cast iron S & S as per IS : 3989
692Providing and Fixing Plain Bend of Required degree .
693100 mm dia
694Sand Cast iron S & S as per IS : 3989
695Providing and Fixing Heel Rest Sanitary Bend
696100 mm dia
697Spun Cast Iron as per IS : 3989
698Providing and Fixing Double Equal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
699100x100x100x100 mm
700Spun Cast Iron as per IS : 3989
70175x75x75x75 mm
702Spun Cast Iron as per IS : 3989
703Providing and Fixing Single Equal Plain Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
704100x100x100 mm
705Sand Cast Iron S&S as per IS : 3989
70675x75x75 mm
707Sand Cast Iron S&S as per IS : 3989
708Providing and Fixing Single Unequal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
709100 x 100 x 75 mm
710Sand Cast Iron S & S as per IS : 3989
711Providing and Fixing Single Unequal Plain Junction of Required degree .
712100 x 100 x 75 mm
713Sand Cast Iron S & S as per IS : 3989
714Providing and Fixing Sand Cast Iron S & S offsets as per IS : 3989
715150 mm off sets
716With 75 mm dia Pipe
717With 100 mm dia Pipe
718Providing and Fixing door piece , insertion rubber washer 3 mm thick , bolts and nuts complete .
719100 mm
720Spun Cast Iron as per IS : 3989
72175 mm
722Spun Cast Iron as per IS : 3989
723Providing and Fixing Terminal Guard :
724100 mm
725Sand Cast Iron S & S as per IS : 3989
72675 mm
727Sand Cast Iron S & S as per IS : 3989
728Providing and Fixing Collar :
729100 mm
730Sand Cast Iron S & S as per IS : 3989
73175 mm
732Sand Cast Iron S & S as per IS : 3989
733Providing Lead Caulked Joints to Sand Cast iron / centrifugally cast spun iron pipes and fittings of diameter :
734100 mm dia pipe
73575 mm dia pipe
736Providing and Fixing MS Stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter :
737100 mm dia pipe
73875 mm dia pipe
739Providing and Fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete , including cost of cutting and making good the walls and floors .
740100 mm inlet and 100 mm outlet
741Sand Cast Iron S & S as per IS : 3989
742Painting Sand cast iron / centrifugally cast ( spun ) iron soil , waste , vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey , or buff etc . Over a coat of primer ( of approved quality ) for new work :
743100 mm diameter Pipes
74475 mm diameter Pipes
745Providing and Fixing GI Pipes complete with GI Fittings and clamps including cutting and making good the walls etc .
746Internal Work - Exposed on Wall
74732 mm dia nominal bore
74840 mm dia nominal bore
74950 mm dia nominal bore
750Painting GI Pipes and Fittings with Synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work :
75132 mm diameter pipe
75240 mm diameter pipe
75350 mm diameter pipe
754Providing and fixing multi-floor trap fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes heavy duty and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete in all respect as directed by Engineer-in-charge.
755Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe complete in all respect as directed by Engineer-in-charge.
756Providing and fixing CP Brass floor cleanout plug / Clean out plug as per drawing complete with G.I. Socket jointed to drainage pipe outlet including drip seal joint complete in all respect as directed by Engineer-in-charge.
757100 mm diameter Pipe
758150 mm diameter Pipe
759Providing and fixing Stainless Steel Grade (304) grating with ring and Stainless steel anti cockroach basket and two SS screw including fixing to the floor with cement mortar.
760SUB HEAD - III : INTERNAL WATER SUPPLY
761Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc
76215 mm dia pipes
76320 mm dia pipes
76425 mm dia pipes
76532 mm dia pipes
76640 mm dia pipes
76750 mm dia pipes
768Painting GI Pipes & Fittings with synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work .
76915 mm dia pipes
77020 mm dia pipes
77125 mm dia pipes
77232 mm dia pipes
77340 mm dia pipes
77450 mm dia pipes
775Providing and Fixing GI Union in GI Pipe including cutting and threading the pipe and making long screws etc . Complete ( New Work )
77615 mm dia pipes
77720 mm dia pipes
77825 mm dia pipes
77932 mm dia pipes
78040 mm dia pipes
78150 mm dia pipes
78265 mm dia pipes
78380 mm dia pipes
784Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makin good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.)
78515 mm dia pipes
78620 mm dia pipes
78725 mm dia .Pipes.
78832 mm dia .Pipes.
789Providing and fixing Thermoflex or Careflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification.
7909 mm thick ( Pipe Inside the Toilets and Exposed in Shafts and Terrace )
791For 15 mm dia Pipe
792For 20 mm dia Pipe
793For 25 mm dia Pipe
794For 32 mm dia Pipe
795For 40 mm dia Pipe
796For 50 mm dia Pipe
797Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc.
79840 mm dia Pipe
79950 mm dia Pipe
800Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
80115 mm dia
80220 mm dia
80325 mm dia
80432 mm dia
80540 mm dia
80650 mm dia
807INTERNAL ELECTRICAL WORK ( 0.125 BOYS DORM. 24 BEDDED )
808SUB HEAD - I: CIRCUIT CUM POINT WIRING
809SWITCH CONTROL LIGHT POINTS
810Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. .
811Group A
812Group B
813Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
814Group A
815Group B
816MCB CONTROL LIGHT POINTS
817Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points)
818Primary point controlled by one MCB.
819Same as item above but Secondary point. i.e. Points to be looped with Primary point with 1.5 sqmm wire and Point wiring
820Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
8212 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
8222 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
8232 X 4 sq. mm + 1 X 4 sq. mm earth wire
8242 X 6 sq. mm + 1 X 6 sq. mm earth wire
8252 x 10 sq. mm + 1 x 6 sq.mm earth wire
8264 X 10 sq. mm + 2 X 6 sq. mm earth wire
8274 X 16 sq. mm + 2 X 6 sq. mm earth wire
828Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required.
829Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required.
830Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
831Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (AC's & Gysers)
832Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
833Telephone socket outlet
834TV antenna socket outlet
835Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
8361 or 2 Module (75mmX75mm)
8376 module (78mm X 205 mm X 50 mm)
838Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
8393 pin , 5/6 amps socket outlet
8405/6 amps switch
841Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
84225 mm
84332 mm
844SUBHEAD -II - FITTINGS & FIXTURES
845Supply, Installation, Testing and Commissioning of 10 W Bulk head Light.
846Supply, Installation, Testing and Commissioning of 5W Mirror Light.
847Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
8488-10 Watt
84912-15 Watt
85018 Watt
851Supplying, installation, Testing & Commissioning of LED (surface/wall) mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq. 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Batten light (System lumen efficacy >135 lm/Watt)
85218-22 Watt
853Supply, Installation, Testing and Commissioning of 10W (Nominal) Wall Bracket Light
854Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
8551200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
856Supply, installation, Testing and commissioning of 250mm Exhaust fan.
857Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
858SUBHEAD - III - DISTRIBUTION BOARDS
859Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8606 way, Double door
8618 way, Double door
86212 way, Double door
863Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
8646 way (4 + 18), Double door
8658 way (4 + 24), Double door
866Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
867Single Pole
868Single Pole Neutral
869Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
870Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
871Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
872Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
873SUB HEAD -IV - LT CABLES & CABLE TRAYS
874Laying of one number PVC Insulated and PVC shethed /XLPE power Cables of 1.1 KV grade of following size direct in ground including excavation,sand cushioning and protecting covering and refilling the trench etc as required.
875Up to 35 sq mm.
876Above 35 sq mm and up to 95 sq mm.
877Above 95 sq mm and up to 185 sq mm.
878Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
879Upto 35 sq.mm
880Above 35 sq. mm and upto 95 sq. mm
881Above 95 sq.mm and upto 185 sq.mm
882S/ F powder coated of approved shade MS Cable Trays
883Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required..
884100 mm width X 50 mm depth X 1.6 mm thickness
885150 mm width X 50 mm depth X 1.6 mm thickness
886300 mm width X 50 mm depth X 1.6 mm thickness
887S/ F powder coated of approved shade MS Cable Tray Bends
888Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
889100 mm width X 50 mm depth X 1.6 mm thickness
890150 mm width X 50 mm depth X 1.6 mm thickness
891S/ F powder coated of approved shade MS Cable Tray Tee's
892Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
893100 mm width X 50 mm depth X 1.6 mm thickness
894150 mm width X 50 mm depth X 1.6 mm thickness
895Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
8964 X 10 sq. mm (28mm)
8974 X 16 sq. mm (28mm)
8983½ X 35 sq. mm (32mm)
8993½ X 50 sq. mm (35mm)
9003½ X 95 sq. mm (38mm)
9013½ X 120 sq. mm (38mm)
902XLPE Insulated Copper Armoured Cables
9032C x 6 Sq.mm.
9042C x 4 Sq.mm.
9053C x 6 Sq.mm.
9063C x 4 Sq.mm.
9074CX 2.5 Sq.mm
9084C x 4 Sq.mm.
909Supply and making End termination with brass Single/ Double compression gland including providing and crimping of aluminum/copper solderless lugs/ferrules for XLPE/PVC insulated armoured power aluminum/copper conductor cables 1.1 KV grade of following sizes:
910SINGLE COMPRESSION GLAND FOR AI. AR. CABLE
9114C/3C x 6/4 sq.mm.
912Single Compression Gland for Cu. Cable
9134C/3C/2C x 4/6/2.5 sq.mm.
914Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.
9154 X 10 sq. mm (25mm)
9164 X 16 sq. mm (28mm)
9173½ X 25 sq. mm (28mm)
9183½ X 35 sq. mm (32mm)
9193½ X 50 sq. mm (35mm)
9203½ X 95 sq. mm (45mm)
9213½ X 120 sq. mm (45mm)
922SUB HEAD -V - EARTHING SYSTEM
923Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
924Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
925Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
926Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
927SUB HEAD - VI :LIGHTNING CONDUCTOR
928Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including accesssories, and providing masonary enclosure with cover plate (CI heavy duty) having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required.
929Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
930Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
931Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
932Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
933Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
934Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
935Supply of Lightnig counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, meet the requirements for IS/IEC 62305 and IEC 62561-2.Tested for Electrical ,Mechanical and Chemical as per IEC 62561.
936FOOTPATH 2.00 MT. WIDE
937Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge
938All kinds of soil
939Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level.
9401:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)s)
941Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
942Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), ncluding making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
943Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
944Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
945Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc., complete.
946Filling available excavated earth (excluding rock) in trenches, plinth, sides of oundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
947Centering and shuttering including strutting, propping etc. and removal of form for all heights :
948Foundations, footings, bases of columns, etc. for mass concrete.
949BILL OF QUANTITIES FOR WATER SUPPLY
950BILL OF QUANTITIES FOR WATER SUPPLY
951DISTRIBUTION NETWORK FOR FRESH WATER SUPPLY
952Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
953External work
95420 mm dia nominal bore
95525 mm dia nominal bore
95632 mm dia nominal bore
95740 mm dia nominal bore
95850 mm dia nominal bore
95965 mm dia nominal bore
96080 mm dia nominal bore
961Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
96220 mm diameter pipe
96325 mm diameter pipe
96432 mm diameter pipe
96540 mm diameter pipe
96650 mm diameter pipe
96765 mm diameter pipe
96880 mm diameter pipe
969Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work.
97020mm dia nominal bore
97125mm dia nominal bore
97232mm dia nominal bore
97340mm dia nominal bore
97450 mm diameter pipe
97565 mm diameter pipe
97680 mm diameter pipe
977Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :
97850 mm dia
97980 mm dia
980Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
98120 mm nominal bore
98225 mm nominal bore
98332 mm nominal bore
98440 mm nominal bore
98550 mm nominal bore
98665 mm nominal bore
98780 mm nominal bore
9881:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
989Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work)
99025 mm nominal bore
99132 mm nominal bore
99240 mm nominal bore
99350 mm nominal bore
99465 mm nominal bore
99580 mm nominal bore
996Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
997LD- 2.5
998Rectangular shape 600*450 mm internal dimensions
999Constructing masonry gate valve Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
1000With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
1001Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
1002with common burnt clay F.P.S.(non module) brick of class designation 7.5
1003ANALYSIS OF RATE FOR SURFACE DRAIN (150X250 MM)
1004Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
1005Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
1006Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level
10071:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
1008Centering and shuttering including strutting, propping etc. and removal of form for all heights :
1009Foundations, footings, bases of columns, etc. for mass concrete
1010Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in :
1011Cement mortar 1:6 (1 cement : 6 coarse sand)
101212 mm cement plaster finished with a floating coat of neat cement of mix :
10131:4 (1 cement: 4 fine sand)
1014Hume pipe
1015Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
1016Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
1017Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
1018450 mm dia. R.C.C. pipe
1019Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 gradded stone aggregate 40 mm nominal size) alround S.W. Pipes including bed concrete as per standard design.
1020BILL OF QUANTITIES FOR SEWERAGE SYSTEM
1021SUB HEAD (I) :- EXTERNAL SEWERAGE SYSTEM
1022Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. anddisposing of surplus excavated soil as directed, within a lead of 50 m :
1023All kinds of soil
1024Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
1025Supply and fixing HDPE double I.S 16098 ( Part - 2 ) 3013 for soil / waste pipe under ground drainage system with jointed with rubber ring with good quality lubricant for fittings, inclusive of all necessary specials like bends, tees, offsets, junctions, re excavtion and refillig etc complete.
1026200 mm dia.pipe
1027250 mm dia. pipe
1028Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
1029250 mm diameter Pipe (L*0.35*0.10=9.89)
1030250 mm diameter S.W. pipe (L*0.45*0.10=0.40)
1031Constructing brick masonry manhole in cement mortar 1 : 4 (1 cement : 4 coarse sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete as per standard design
1032Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)
1033With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5
1034Extra for depth for manholes:
1035size 90 X 80 cm
1036With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1037Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with FPS bricks class designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
10380.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately)
1039with common burnt clay F.P.S.(non module) brick of class designation 7.5
1040Extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m .
1041with common burnt clay F.P.S.(non module) brick of class designation 7.5
1042Providing and fixing square mouth S. W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
1043180 x 150 mm. size P type
1044With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1045Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :
1046With 20 mm dia round bar
1047ANALYSIS OF RATE FOR SEPTIC TANK ( 50 USER'S)
1048Size of Tank = 5.00 X 2.00 X 1.24 Mtr
1049Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
1050Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
1051Earth work in Excavation 1.50-3.00 mtr
1052Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
1053Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
10541:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
1055Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
1056Upto plinth level
1057Centering and shuttering including strutting, propping etc. and removal of form for:
1058Foundations, footings, bases of columns, etc. for mass concrete.
1059Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc.
1060Lintels, beams, plinth beams, girders, bressumers and cantilevers.
1061Suspended floors, roofs, landings, balconies and access platform.
1062Edges of slabs and breaks in floors and walls.
1063Under 20 cm wide
1064Providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of Engineer-in-charge.
1065Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
1066Thermo-Mechanically Treated bars.
10671:3 (1 cement: 3 fine sand)
10686 mm cement plaster on rough side of single or half brick wall of mix:
10691:3 (1 cement: 3 fine sand)
1070Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
1071HD-20
1072Circular shape 560 mm internal diameter
1073Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
1074Providing and fixing soil, waste and vent pipes
1075100 mm dia.
1076Centrifugally cast (spun) iron socketed pipe as per IS: 3989.
1077Providing and fixing terminal guard :
1078100 mm
1079Sand cast iron S&S as per IS - 3989
1080Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks
1081ANALYSIS OF RATE FOR SEPTIC TANK (100 USER'S)
1082Size of Tank = 5.70 X 2.10 X 1.70 Mtr
1083Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
1084All kinds of soil
1085ordinary rock
1086Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
1087all kinds soil
1088Take 50 % Qty of items 2.A
1089ordinary rock
1090Take 50 % Qty of items 2.A
1091Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
1092Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
10931:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
1094Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
1095Centering and shuttering including strutting, propping etc. and removal of form for:
1096Foundations, footings, bases of columns, etc. for mass concrete.
1097Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
1098Lintels, beams, plinth beams, girders, bressumers and cantilevers.
1099RCC Bend Beam
1100Suspended floors, roofs, landings, balconies and access platform.
1101Edges of slabs and breaks in floors and walls.
1102Under 20 cm wide
1103Providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of Engineer-in-charge.
1104Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
1105Thermo-Mechanically Treated bars.
110652 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
11076 mm cement plaster on rough side of single or half brick wall of mix:
11081:3 (1 cement: 3 fine sand)
1109Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
1110HD-20
1111Circular shape 560 mm internal diameter
1112Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
1113Providing and fixing soil, waste and vent pipes
1114100 mm dia.
1115Centrifugally cast (spun) iron socketed pipe as per IS: 3989.
1116Providing and fixing terminal guard :
1117100 mm
1118Sand cast iron S&S as per IS - 3989
1119Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks
1120ESTIMATE OF ELECTRICAL WORKS
1121SUBHEAD - I - MAIN BOARDS
1122Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 50 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below.
1123(Note:The contractor may select the next higher fault rating of MCCB if it is not readily available ,without any extra cost ,as the figure indicated within the bracket are required maxmum fault level of the panel.)
1124FEEDER PILLAR
1125Design, Manufacturing, supplying, fixing in position, testing and commissioning of the following front operated front access 2mm thick CRCA steel enclosure free standing, water, dust and vermin proof outdoor type Feeder pillars with IP-55 protection hinged and lockable doors complete with interconnections copper crimping lugs, brass glands bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system . The panels fault withstanding capacity shall be of 25 MVA at 415 volts. All live accessories part shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be of colure coded with Heat shrinkable PVC insulated sleeves.
1126FEEDER PILLAR-1:
1127INCOMER
11281 No. 160A, 415V, Ics=25kA, 4P MCCB with thermal magnetic trip unit.
11291 No. Digital multifunction meter (V+A+Hz) with a set of cast resin CTs 160/5A.
11301 Set of Phase indicating lamp with MCB
1131BUS BARS-I :
1132200A TPN bus bars of aluminium alloy.
1133For emergency supply
11341 No. 63A, 415V, Ics=25kA, 4P MCCB with thermal magnetic trip unit.
11351 Set of On indicating lamp with MCB
1136BUS BARS-II :
1137100A TPN bus bars of aluminium alloy.
1138OUT GOING BUS-I :
11398 Nos. 63A 415V, 4P MCCB of 15kA .
11401 No. MCB Space.
1141OUT GOING BUS-II :
11425 Nos. 63A 415V, 4P MCB of 10kA .
11431 No. 40A 415V, 4P MCB of 10kA with 40A 4P Contactor & timer switch .
11442 Nos. 25A 415V, 4P MCB of 10kA .
11451 No. MCB Space.
1146METER BOARDS
1147Supply, installation, testing and commissioning of M.V. cubical type totally enclosed dust, dump and vermin proof Meter Bords complete with bus bars, MV danger notice plate, on surface ISI marked Electronic kWh meter, indication lamps, CT's, Interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoing MCBs MCCBs and kWh meters complete as required.
1148METER BOARDS -DORMITORY BOYS & GIRLS
11491 No. 63A, 415V, Ics= 16kA, 4P MCCB with O/C, S/C protection & on indication lamp.
1150BUS BARS:
1151100A TPN bus bars of aluminium alloy.
1152OUT GOING:
11532 Nos. 40A DP MCB of 10kA with space for electronic direct kWh energy meter complete with all necessary wiring as per the Meter vendor requirement.
11547 Nos. 40A DP MCB of 10kA.
1155SUBHEAD - III - SUPPLYING & LAYING OF CABLE
1156L.T. CABLES
1157Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
11584 X 6 sq. mm
11594 X 10 sq. mm (28mm)
11604 X 16 sq. mm (28mm)
11613½ X 25 sq. mm (28mm)
11623½ X 35 sq. mm (32mm)
11633½ X 50 sq. mm (35mm)
11643½ X 150 sq. mm (50mm)
11653½ X 185 sq. mm (57mm)
11663½ X 240 sq. mm (62mm)
11673½ X 300 sq. mm (70mm) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56009528
AUTHORITY Government Departments
TENDER VALUE 4.81 Crore
LAST DATE 07-07-2026
Authority
Authority Name Uttar Pradesh Projects Corporation Limited
Work Description Tender for Construction Of Phase-B (Balance) Works At Jnv Harda (M.P.)
Basic Detail
Tender No 08/GM(T)/UPPCL/2026-27/DATE 15.06.2026
Bidding Type Tender
Location
City Harda
State Madhya Pradesh
Key Dates
Publish Date 16 Jun 2026
Submission Date 07 Jul 2026
Open Date 07 Jul 2026
Finance
Tender Value 4.81 Crore
Tender Fee 17700
EMD 9.64 Lakhs
Exemption Not Available
Document List
BID.pdf
BOQ_2176253.xls
ef15d3e8-b569-4879-8386-63129609fac0.html
Tendernotice_1 (21).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
pdf

BID.pdf

xls

BOQ_2176253.xls

html

ef15d3e8-b569-4879-8386-63129609fac0.html

pdf

Tendernotice_1 (21).pdf

TenderDetail
Loading tenders