| 1 | Provide all materials labour T&P etc. complete and constructed Bye-pass chamber for pump house ( 1000 (L) x 1000 (W) x 1150 (H) mm ) drawing (drawing no.D-3) and as per the specifications for civil work given in the bid document including supply of all material labour and T&P etc complete as per instructions of Engineer -in -charge. |
| 2 | 25mm thick 1:2:4 p.C.C. floor with cement, coarse sand and 20mm gauge stone ballast with base concrete (75mm thick) 1:4:8 cement, local sand & brick ballast 40mm gauge. |
| 3 | 12mm thick Plaster with cement ,coarse sand in 1:4 over wall in place of previously removed damaged wall plaster including supply of all materials,labour, T&P etc complete. |
| 4 | Double priming coat with putty and double coat Exterior emulsion paint 100% acrylic smooth (Apex weather coat ) Asian ,Berger weatherproof new work including supply of all materials, labour, T&P etc. required for proper completion of work as per directions of engineer in charge. |
| 5 | Supply of Flush door incluiding all material T&P etc complete |
| 6 | Installation of Electronic type Dosing System incluiding supply of all labour T&P etc complete |
| 7 | Dismentling of exist damaged & loose plaster incluiding all labour T&P etc complete |
| 8 | Supply of all material, labour, T&P etc. oomplete for fixing of railing in three rows on one side with 20mm GT pipe (class - medium), necessary J\Angle posts 50*50*6 mm or RCC Post in stair case, balcony and top dome including welding or angle with grouted MS plate, bending and fixing of G1 pipe including supply or U-clamp & nut bolts as per specification and instructions of Engineer-in-charge. |
| 9 | Supply of all material, labour, T&P etc. complete for installation of Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules.It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed metal of propr size prescribed by ISS 2309-1969 including earthing pit as per directions of engineer in charge . |
| 10 | Supply of all material, labour, T&P etc. complete for installation of Water level indicator fabricated with good quality minimum 45mm x 45mm x 6mm M.S.angle and 3mm thick 6mm flat M.S.sheet. The indicator board scale made of 3mm thick M.S. plate should have a clear width of minimum 25cm painted with good Asian paint.It should also consists of 3mm brass wire rope minimum 4 smooth pulleys about 8 cm dia with guides,15cm dia copper ball float which shall be completely water tight suitable pointer of brass etc. as per directions of engineer in charge. |
| 11 | Cleaning of Over Head R.C.C. Tank ( independent staging) including disposal or slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations: (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of sill and other deposits. (ii) Entire surface area ot the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated su1tace shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. UP To 250 KL |
| 12 | Double priming coat with putty and double coat Exterior emulsion paint 100% acrylic smooth (Apex weather coat ) Asian ,Berger weatherproof new work including supply of all materials, labour, T&P etc. required for proper completion of work as per directions of engineer in charge. |
| 13 | Supply & Fixing of Mosquito net around the ventilator including labour T&P etc complete as per direction of Engineer-in-charge |
| 14 | Supply of following sizes pipes for distribution system conforming to latest/ relevant I.S. 4984/1995 Specifications with all jointing materials and specials conforming to latest/relevant I.S. specifications including F.O.R. destination and all taxes and insurance etc. with loading, unloading and Carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of Engineer ‐in ‐ charge. 63 mm dia HDPE Pipe PN‐6: Class PE‐100 |
| 15 | Excavation of earth in ordinary soil (loam, clay or sand) for pipe line and rising main trenches including lift upto 1.50 m and lead upto 50 m and refilling watering, ramming of the excavated earth into the trench and also disposal of surplus earth upto 50m from the center of the trenches including supply of all material labour, T&P etc complete as per instructions of Engineer ‐in ‐charge. 63 mm dia HDPE Pipe PN‐6: Class PE‐100 |
| 16 | Provision for following types of Culvert/Road Crossing crossing along the alignment of pipe line complete as per instructions of Engineer ‐in ‐charge. ( casing of pipe is done by concreting) |
| 17 | Bituminus Road |
| 18 | Interlocking Road |
| 19 | C.C. Road |
| 20 | Providing and fixing GI Pipe complete with GI Fitings and clamps including making of good the wall etc.. |
| 21 | Replacement of Damage upvc 200 Lit. Tank & supply of new 200 Lit. UPVC including loading unloading etc for the proper completion of the work. |
| 22 | Construction of Sluice Valve Chamber Please Enable Macros to View BoQ information |