| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) BANGALORE NAME OF WORK : REPAIRS MAINTENANCE TO COMPUND WALL, PERIMETER WALL, CATTLE FENCING , CHAIN LINK FENCING, BARBED WIRE, CONCERTINA COIL & OTHER B/R WORKS IN RED QTRS, MTC, GJC, TRINITY OFFCRS MESS AREA AT CHAFB. CA NO: GE(AF)/B/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) complete all as specified and as directed by Engr-in-charge.Note: All demolition materials shall be removed from site and deposited out side Defence land his risk and cost, no extra payment shall be madeon this account . site to be clean and level after removing of debris as required and directed by Engr-in-charge. |
| 3 | Demolition of brick work or stone masonary built in cement mortar including all quoins arches pillars etc, but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and as directed by Engr-in-charge. |
| 4 | Material and labour for precast cement concrete block masonry with solid blocks type C1, 1:3:6 (Using 20mm graded stone aggregate) exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed by Engr-in-charge. |
| 5 | Material and labour for providing precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints) type C1, 1:3:6 (Using 20mm graded stone aggregate) and setting in cement mortar 1:6 complete all as specified and as directed by Engr-in-charge. |
| 6 | Material and labour for 100mm thick PCC 1:2:4 type B-2 (Using 40mm graded stone aggregate) for floor including finishing the surface even and smooth with using extra cement complete all as specified and as directed by Engr-in-charge. |
| 7 | Material and labour for 75mm thick PCC 1:2:4 type B-1 (Using 20mm graded stone aggregate) for hard standing, including finishing the surface even and fair complete all as specified and as directed by Engr-in-charge. |
| 8 | Material and labour for 50mm thick PCC 1:2:4 type B-2 (Using 20mm graded stone aggregate) for floor including finishing the surface even and fair complete all as specified and as directed by Engr-in-charge. |
| 9 | Material and labour for forming construction joint 30mm deep x 10mm wide filled with sealing compound, grade 'A' complete all as specified and as directed by Engr-in-charge. |
| 10 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engr-in-charge. |
| 11 | Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. |
| 12 | Material and labour for rendering 15mm thick other then fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. |
| 13 | Material and labour for preparing new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer on surfaces of walls complete all as specified and as directed by Engr-in-charge. |
| 14 | Material and labour for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by Engr-in-charge. |
| 15 | Material and labour preparation of old painted plaster surface of any description not otherwise described for road kerb stone, concrete, stone, brick edging etc., surface over 10 cm width or girth and applying one coat of synthetic enamel paint of any colour complete all as specified and as directed by Engr-in-charge. |
| 16 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design and pattern as in foot path, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness and size/ shape, made by table vibratory method using PU mould, laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed by Engr-in-charge. |
| 17 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design and pattern as in foot path, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness and size/ shape, made by table vibratory method using PU mould, laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed by Engr-in-charge. |
| 18 | Providing and laying of machine pressed precast conctete glossy finish interlocking paver block any shape and size confirming to IS 15658-2006 of 100mm thickness M-35 grade and pointed with grey cement mixed with pigment to match complete all as specified and as directed by Engr-in-charge. |
| 19 | Relaying of machine pressed precast conctete coloured interlocking paver block any shape and size old serviceable of 60mm thickness with grey cement and pigments complete all as specified and as directed by Engr-in-charge. |
| 20 | Relaying of machine pressed precast conctete coloured interlocking paver block any shape and size old serviceable of 80mm thickness with grey cement and pigments complete all as specified and as directed by Engr-in-charge. |
| 21 | Relaying of machine pressed precast conctete coloured interlocking paver block any shape and size old serviceable of 100mm thickness with grey cement and pigments complete all as specified and as directed by Engr-in-charge. |
| 22 | Material and labour for 40 mm thick sand cushioning including watering for interlocking tiles complete all as specified and as directed by Engr-in-charge. |
| 23 | Material and labour for hardcore of gauge not exc 63mm of broken stone, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-in-charge. |
| 24 | Material and labour for 75mm thick cement concrete type C-2, 1:3:6 (Using 40mm graded stone aggregate) as in flooring, foot path, hard standing, plinth protection, bases of water tanks etc., finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. |
| 25 | Material and labour for coloured designed chequered cement concrete tiles of a size 300x300x25mm thick with grey cement and pigment in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed of cement mortar 1:6 complete all as specified and as directed by Engr-in-charge. |
| 26 | Material and labour for preparing of old chequered tiled and paver block surfaces/ existing footpath by removing all the caked mud with wire brushes and cleaning surfaces with necessary acid and description not otherwise described and applying one coat of weather proof tile guard apex paint of any colour complete all as specified and as directed by Engr-in-charge. |
| 27 | All as per item No.25 here-in-before but applying one coat of weather proof tile guard apex paint of any colour complete including one coat of alkali resistant primer complete all as specified and as directed by Engr-in-charge. |
| 28 | All as per item No.25 here-in-before but two coats of weather proof tile guard apex paint of any colour complete all as specified and as directed by Engr-in-charge. |
| 29 | Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and as directed by Engr-in-charge. |
| 30 | Supply and fix for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engr-in-charge. |
| 31 | Material and labour for two coats of synthetic enamel paints over a coats of red oxide zine chrome primer including prepration of new /previously untreated steel surfaces of any description over 10cm in width or girth not otherwise described complete all as specified and as directed by Engr-in-charge. |
| 32 | Material and labour for preparation of old painted surface of any description not otherwise described steel and iron surface over 10cm width or girth and applying one coat of synthetic enamel paint of any colour complete all as specified and as directed by Engr-in-charge. |
| 33 | Material and labour for preparation of old decorated plsatered or unplastered surface of walls including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc., and applying one coat of white washing complete all as specified and as directed by Engr-in-charge. |
| 34 | All as per item No.32 here-in-before but two coats of white washing on walls complete all as specified and as directed by Engr-in-charge. |
| 35 | Material and labour for two coats of cement based over a coat of primer on plastered and other surfaces with alkali resistant priming paint including preparation of old surface after complete removal of existing treatment complete all as specified and as directed by Engr-in-charge. |
| 36 | Material and labour for preparation of old decorated surface of wall and applying one coat of cement based paint complete all as specified and as directed by Engr-in-charge. |
| 37 | Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6, including dismantling of masonry complete all as specified and as directed by Engr-in-charge. |
| 38 | Material and labour for flush pointing to random rubble masonry, uncoursed or brought upto course in CM 1:4 complete all as specified and as directed by Engr-in-charge. |
| 39 | Material and labour for rendering 10mm thick on fair faces of concrete surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. |
| 40 | Supply and fix in repair 1.25mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc., as required complete all as specified and as directed by Engr-in-charge. |
| 41 | Supply and fix for steel work in tubular trusses including special shaped washer etc., complete using ERW or indluding butt welded tubes conforming to I.S.1161-1998 grade St-240 complete all as specified and as directed by Engr-in-charge. |
| 42 | Supply and fix for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., not exc 10 kg each brackets, conforming to Fe.290. Gde-E-165 complete all as specified and as directed by Engr-in-charge. |
| 43 | Material and labour for running welding in repairs for thickness of metal not exc 6mm complete all as specified and as directed by Engr-in-charge. |
| 44 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings complete all as specified and as directed by Engr-in-charge. |
| 45 | Supply and fix for prepainted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws/ J hooks and bolts complete all as specified and as directed by Engr-in-charge. |
| 46 | Supply and fix for prepainted galvalume aluminium zinc coating GI based plain steel sheeting 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws/ J hooks and bolts complete all as specified and as directed by Engr-in-charge. |
| 47 | Supply and fix in repair galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc., complete all as specified and as directed by Engr-in-charge.Note: Eeach line wire to be measured. |
| 48 | Repair to existing galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining including strenthing, tighting, and binding with new or old fencing post /flat iron /nuts, bolts etc., complete all as specified and as directed by Engr-in-charge.Note: Fencing post /flat iron /nuts, bolts etc., required as new item will be measured and paid separately. |
| 49 | Supply and fix in repairs concertina coil of gauge 2.6mm and using coil of 61 cm dia over MS angle brackets with barbed wire complete all as specified and as directed by Engr-in-charge. |
| 50 | Repair to existing concertina coil of gauge 2.6mm and using coil of 61 cm dia including strenthing, tighting and binding with new or old fencing post /flat iron /nuts, bolts etc., complete all as specified and as directed by Engr-in-charge.Note: Fencing post /flat iron /nuts, bolts etc., required as new item will be measured and paid separately. |
| 51 | Material and labour for preparation of old painted surface of any description not otherwise described steel and iron surface not exc 10 cm width or girth and applying one coat of synthetic eanmel paint of any colour complete all as specified and as directed by Engr-in-charge. |
| 52 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-charge. |
| 53 | Material and labour for cement concrete 1:2:4, type B-1 (Using 20mm graded stone aggregate) as in coping, kerb etc., including necessary form work complete all as specified and as directed by Engr-in-charge. |
| 54 | Material and labour for 75mm thick cement concrete type C-2, 1:3:6 (Using 40mm graded stone aggregate) as in flooring, foot path, hard standing, plinth protection, bases of water tanks etc., complete all as specified and as directed by Engr-in-charge. |
| 55 | Material and labour for PCC 1:3:6 type C-2 (Using 40mm graded stone aggregates) in fixing of fencing post fillings and mass concrete complete all as specified and as directed by Engr-in-charge. |
| 56 | Material and labour for broken glass coping on top of walls in cement mortar 1:3 complete all as specified and as directed by Engr-in-charge. |
| 57 | Removing old dumped junk/ building materials/ debris/ tree roots, trunk and branches of any size etc., to a distance of 30 KM or beyond, out of premises of metropolitan area, including loading, unloading by manually or by mechanical means (JCB) and to be transported through tractor-trolly or tipper and stacking at the destination complete all as specified and as directed by Engr-in-charge. |
| 58 | Demolition of reinforced cement concrete in ground floors (below or above ground level) complete all as specified and as directed by Engr-in-charge. |
| 59 | Excavation in trenches not exc 1.5m wide and not exc 1.50m in depth for foundations etc., and getting out in hard /dense soil complete all as specified and as directed by Engr-in-charge. |
| 60 | Material and labour PCC 1:4:8 type D-2 (Using 40mm graded stone aggregates) in foundation, fillings and mass concrete complete all as specified and as directed by Engr-in-charge. |
| 61 | Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed by Engr-in-charge. |
| 62 | Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete, square, rectangular or polygonal complete all as specified and as directed by Engr-in-charge. |
| 63 | Use and waste of form work to side and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintel beam, tie beam, cantilevers, shelves including supports, overhangs, etc., also splays between floors and rough finished complete all as specified and as directed by Engr-in-charge. |
| 64 | Material and labour for TMT bars 10mm dia and over, cut to length, bent to shape required, inculding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-charge. |
| 65 | All as per item No.65 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed by Engr-in-charge. |
| 66 | Material and labour for RCC (nominal mix) type B1 1:2:4 (Using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for coloumns, etc., basement slabs, under reamed piles and mass concrete complete all as specified and as directed by Engr-in-charge. |
| 67 | Material and labour for RCC (nominal mix) type B1 1:2:4 (Using 20mm graded stone aggregate) in columns, pillars, piers, posts and struts complete all as specified and as directed by Engr-in-charge. |
| 68 | Material and labour for RCC (nominal mix) type B1 1:2:4 (Using 20mm graded stone aggregate) in beams, cantilevers, bressummers, tie beam, lintels over 1.5m span complete all as specified and as directed by Engr-in-charge. |
| 69 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm in hard /dense soil complete all as specified and as directed by Engr-in-charge. |
| 70 | Supply and fix for 6mm thick coloured, opaque, multiwall polycarbonate sheet including fitting to the frame work complete all as specified and as directed by Engr-in-charge. |
| 71 | Grubbing up tree trunk including cutting of trunk portion exc 30cm and not exc 100cm girth protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance not exc 50m and clearing site complete all as specified and as directed by Engr-in-charge. |
| 72 | Cutting of roots of girth exc 20 cm and making clear site for excuetion of work and removing of unserviceable material to a distance not exc 50m and clearing site complete all as specified and as directed by Engr-in-charge. |
| 73 | Removing excavated material (soil) not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and as directed by Engr-in-charge. Total in Figures 0.0 23 Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |