| 1 | Schedule 'A' Part-I (Term contract for existing squash courts and sport complex of Keithelmanbi Grn) |
| 2 | Dismantling wooden boarding in lining of walls/ flooring and partitions, excluding supporting members but including stacking within 50 metres lead : Thickness above 10 mm up to 25 mm |
| 3 | Providing and fixing World Squash Federation (WSF) approved wooden flooring system for squash court, consisting of seasoned hardwood (maple/beech) top layer over engineered subfloor system with shock absorbing pads/battens, moisture barrier, fixing system, sanding, polishing, and game line markings, complete in all respects as directed by Engineer-in-Charge, conforming to World Squash Federation. |
| 4 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 5 | Supplying and applying for proper rebound treatment to squash court walls cement based hard plaster with a total thickness of 15mm on striking wall of squash court. The hard plaster shall confirm the requirements of World Squash Federation (WSF) consisting of a base coat 11 mm thick and finishing coat 4 mm thick as per specifications including surface preparation with smooth impact-resistant surface complete in all respects as directed by Engineer-in-Charge, conforming to World Squash Federation. |
| 6 | Providing and applying “Ultima” or equivalent high-quality acrylic polyurethane / specialized sports wall paint on squash court walls to achieve smooth, non-gloss finish, including surface preparation, putty application, sanding, primer coat, minimum two coats of paint and finishing complete as per standard, conforming to World Squash Federation, as directed by Engineer-in-Charge. |
| 7 | Providing and fixing squash court sound board (tin board) on the front wall at specified height, fabricated with 22 gauge MS/ galvanized steel sheet, properly fixed with frame/ anchors, finished with smooth surface and painted with durable non-gloss coating, including marking line, complete in all respects as per World Squash Federation and as directed by Engineer-in-Charge. |
| 8 | Supply, installation, testing and commissioning of suspended type surface mounted LED batten fitting with CRCA body having system output not less than 3700 Lumens and wattage not less than 37W and latest LED technology of consistent light output, IP20 rating CRI>80, power factor>0.95, THD less than10%, stable color performance and colour temperature not less than 5700K and energy saving, suitable foruseon 230V,50 Hz,A.C supply, ceiling at the height of 5-6 Mtrs including wiring with 1.5 Sqmm/ 2.5 Sqmm single core copper wire incl suitable PVC conduit & connections etc. complete as required. |
| 9 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats. |
| 10 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface. |
| 11 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Old work (one or more coats) i/c the cost of the ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 12 | Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters Kiln seasoned and chemically treated hollock wood |
| 13 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) incl dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 14 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 15 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. Please Enable Macros to View BoQ information |