Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #56007882

Tender For Repair/Replacement Of Burnt Mccbs, Mcb Dbs, Submain Wiring, Internal Fittings & Fixtures, Earthing Service Connection, Meter Box And Connected Work In Jcos/Or Md Accn At Sp Line, Mp Line, Kb Line Odf, Taj View, Sheron Line, Bp Line & Aats

Issued by Statutory Bodies & Commissions/Committees · Agra, Uttar Pradesh
Tender Value
30 Lakhs
Estimated cost
Bid Submission
07 Jul 2026
1 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Burnt Mccbs, Mcb Dbs, Submain Wiring, Internal Fittings & Fixtures, Earthing Service Connection, Meter Box And Connected Work In Jcos/Or Md Accn At Sp Line, Mp Line, Kb Line Odf, Taj View, Sheron Line, Bp Line & Aats Under Ge (East) Agra

BOQ

Name of Work:- REPAIR/REPLACEMENT OF BURNT MCCBs, MCB DBs, SUBMAIN WIRING, INTERNAL FITTINGS & FIXTURES, EARTHING SERVICE CONNECTION, METER BOX AND CONNECTED WORK IN JCOs/OR MD ACCN AT SP LINE, MP LINE, KB LINE ODF, TAJ VIEW, SHERON LINE, BP LINE & AATS UNDER GE (EAST) AGRA
Sl. No. Item Description
1Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete and all as specified and directed.
2M&L for Point wiring complete with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, MS sunken boxes duly painted with one coat of red oxide and one coat of black paint not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. (a) One light/Fan/Exhaust Fan point controlled by one switch.
3All as per item No 2 here in before but for one 3 Pin 5 Amp switch Socket outlet point on an independent board.
4All as per item No 2 above but one 3 Pin 5 Amp switch Socket outlet point on Same board with other switches.
5All as per item No 2 above but One Bell/Buzzer point controlled by one push button on same board with other switches or independent.
6All as per item No 2 above but One light point controlled by two 2 way switches.
7All as per item No 2 here in before but with cable size FRLSH cable 4 Sq mm for one AC socket out let 15 Amps and multistrand insulated copper earth continuity conductor of size FRLSH cable 4 sqmm all as specified and directed
8M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FRLSH PVC insulated unsheathed cable with proper colour coding drawn in existing PVC concealed conduit with all accessories and FRLSH PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, including cutting and chasing of wall surface for sunken box and connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. One light /fan/Exhaust Fan point controlled by one switch
9All as per item No 8 here in before but for one 3 Pin 5 Amp switch Socket outlet point on an independent board.
10All as per item No 8 above but one 3 Pin 5 Amp switch Socket outlet point on Same board with other switches.
11All as per item No 8 above but One Bell/Buzzer point controlled by one push button on same board with other switches or independent.
12All as per item No 8 above but One light point controlled by two 2 way switches.
13All as per item No 8 here in before but with cable size FRLSH cable 4 Sq mm for one AC socket out let/ 15 Amps and multistrand insulated copper earth continuity conductor of size FRLSH cable 4 sqmm all as specified and directed
14S&F switch piano flush button single pole one way 5/6 amps 240 volts with polycarbonate body complete all as specified and directed.
15S&F switch piano flush button single pole one way 20 amps 240 Volts with polycarbonate body complete all as specified and directed.
16S&F switch piano flush button single pole two way 6 amps 240 Volts with polycarbonate body complete all as specified and directed.
17S&F socket 5 amps 3 pin flush type, 240 volts. with polycarbonate body com-plete all as specified and directed.
18S&F socket outlet, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
19S&F Bell push, flush type, 5/6 amp, complete all as specified and directed.
20S&F in repair call bell, Ding dong type, 230 volts AC single pole complete all as directed.
21S&F ceiling rose , PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals all as specified and directed.
22S&F in repair stepped type electronic fan regulator switch/socket type ISI marked on the existing phenolic laminated sheet etc. as required, complete all as specified and directed.
23S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (Approx 4 feet 20W) luminaire lumen >2000 lm, system efficiency of >100 lumens /W, with Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
24S&F in repair Inverter LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 3-4 hours, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (Approx 4 feet 20W) luminaire complete all as specified and directed.
25S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >100 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
26S&F in replacement LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 25 mm dia GI light grade pipe, 1.00 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 35x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduit including all accessories and fixing arrangements for fixing the light fitting and writing the date of fixing on security light with permt marker complete all as specified and directed.
27S&F in repair of bulk head fitting made from POLYCARBONATE, IP-65, IK 08, SURGE 4KV Protection cover suitable for bulk head fitting integrated type 10 watts LED ,6500K , including inbuilt electronic driver complete and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.50 Sqmm and fixing arrangements for fixing the light fitting complete all as specified & directed.
28M&L in repair for Submain wiring with two single core FRLSH 4 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall or ceiling for sub main connection including FRLSH 4 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly including taking down old unsv submain wiring complete all as specified. Note:- Two single core FRLSH 4 sqmm copper conductor, one run PVC conduit and one run of FRLSH 4 sqmm earth wire shall be considered & measured as one unit.
29M&L in repair Submain wiring with two single core FRLSH 6 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall or ceiling for sub main connection including FRLSH 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connec-tion to earth dolly including taking down old unsv submain complete all as specified.Note:- Two single core FRLSH 6 sqmm copper conductor, one run PVC conduit and one run of FRLSH 6 sqmm earth wire shall be considered & measured as one unit.
30S&F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp, complete all as specified and directed.
31Supply, installation, testing and commissioning of indoor type wall mounting size min (680 X 1100 X 245mm), Polycarbonate CPRI approved OEM made Meter Panel suitable for 04 (four) Single phase meter. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel type wall mounted on mounting structure RAL 7016. The meter panel should be anti-acid & anti corrosive & fully transparent Door for meter vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only degree of ingress protection IP65 in accordance with IEC 60529. The gasket should be internally embedded made of polyurethane and enclosure make. The manufacturer of board/panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1 complete all as specified and directed. Note : Re-fixed the energy meter in new meter cabinet including all necessary electrical connection. General Specification & Electrical Parameters: 4 Meter DB Ref No. 2236 / 2023(REV-1).Type of Panel: -Thermoplastic Polycarbonate. Panel Size: -680x 1100x 245mmDegree of Protection: -IP65(EN60 529) SystemVoltage:415V,50Hz,4wire+E Installation: -Indoor Floor mountingCable Entry: -Incoming/outgoing from bottom. Finish Shade: -Enclosure & Accessories: RAL 7035 Mounting structure: RAL 7016Incomer: 125 A, FP 25mA MCCB-01 NosOutgoing: 40A DP 10kA MCB – 4 Nos(10-60)A, 1Phase PREPAID ENERGY METER-4 Nos (Provision Only)Terminals- 10SQMM TERMINAL BLOCK- 8 Nos10SQMM TERMINAL BLOCK- 4 NosMake-Hensel/Rittel/Schnieder
32S&F Single Source Single Phase Two Wire AC Static Energy (10-60A) Class:1.0 Key pad based Pre-payment Electronic Energy Meter with Customer Interface Unit (CIU) including taking down old unsv meter and deposit to AGE E/M yard complete all as specified and directed.
33S&F Single Source Three Phase Four Wire AC Static Energy (10-60A) Class:1.0 Key padbased Pre-payment Electronic Energy Meter with Customer Interface Unit (CIU) including taking down old unsv meter and deposit to AGE E/M yard complete all as specified and directed.
34S&F in repair of sheet metal enclosure Vertical TPN DB 4 Way double door As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar for each phase with 2 Neutral bar, 2 earthbar and Cable ties for Cable manage-ment, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for easy of installation, Prefitted masking sheet, Reversible Door for IP 43 DB's, suitable for 160 Amp MCCB as incomer and SP/TP MCB's as outgoing including taking down old unsv MCB DB and MCBs complete all as specified and directed.
35S&F in repair MCB DB triple pole with neutral sheet metal enclosure double door type, 415 Volts AC, with appropriate size bus bar plate and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCBs and with enclo-sure blank plates for unused way suitable for 4 way ISI marked including taking down old unsv MCB DB and MCBs complete all as specified and directed.
36S&F in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with appropriate size bus bar and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 4 way ISI marked, including taking down old unsv MCB DB and MCBs complete all as specified and directed.
37S&F in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with appropriate size bus bar and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 8 way ISI marked, including taking down old unsv MCB DB and MCBs complete all as specified and directed.
38S&F in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with appropriate size bus bar and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 12 way ISI marked, including taking down old unsv MCB DB and MCBs complete all as specified and directed.
39S&F in repair MCB TPN 40-63 Amp rating 415V, 10KA 'C' curve and current carrying ca-pacity in the MCB DB complete with connection complete all as specified and directed.
40S&F in repair MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection complete all as specified and directed.
41S&F in repair MCB SPN 40-63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection complete all as specified and directed.
42S&F in repair MCCB 4 pole, 160 Amps, 50 Hz, Icu=25 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 80% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard complete all as specified and directed.
43M&L for earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , con-nected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed.Notes:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor complete all as specified and directed.
44S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chas-es or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated sit-uation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
45S&F in repair switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
46S&F in repair Switch piano flush button single pole one way 20 amps 240 Volts with polycarbonate body complete all as specified and directed.
47S&F in repair socket 5 amps 3 pin flush type, 240 volts. with polycarbonate body com-plete all as specified and directed.
48S&F in repair socket outlet, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 240 volts with polycarbonate body complete all as specified and directed.
49Taking down, electric meters 10-60 amps in meter panel and refixing in same position after necessary repair and connectng complete as specified and direced.
50S&F in repair 4 Pair Telephone Cable 0.4 sqmm copper of diameter and is insulated with a special grade polyethylene compound on the latest state-of-the-art extruders. The cores are twisted together with a uniform lay from meter to CIU units, complete all as specified and directed.
51S&F Rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
52S&F in repair of sunk in cast iron/Pressed steel terminal box of size 5\\"x 5\\", 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint out side/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications, complete all as specified and directed.
53S&F in repair of sunk in cast iron/Pressed steel terminal box of size 7\\"x 5\\", 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint out side/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications, complete all as specified and directed.
54S&F in repair of sunk in cast iron/Pressed steel terminal box of size 8\\"x 10\\", 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint out side/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications, complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56007882
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 07-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Burnt Mccbs, Mcb Dbs, Submain Wiring, Internal Fittings & Fixtures, Earthing Service Connection, Meter Box And Connected Work In Jcos/Or Md Accn At Sp Line, Mp Line, Kb Line Odf, Taj View, Sheron Line, Bp Line & Aats Under Ge (East) Agra
Basic Detail
Tender No 9907/E8
Bidding Type Tender
Location
City Agra
State Uttar Pradesh
Key Dates
Publish Date 16 Jun 2026
Submission Date 07 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
13495e9e-f48b-43f0-946c-effab60aa14b.html
BOQ_864993.xls
PS9907.pdf
Tender9907.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

13495e9e-f48b-43f0-946c-effab60aa14b.html

xls

BOQ_864993.xls

pdf

PS9907.pdf

pdf

Tender9907.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders