Tender For Replacement Of Precision Air Conditioners ( Pac) Of Hbni Server Room And Other Miscellaneous Work , Anushaktinagar, Mumbai -94., Hbni, Anushaktinagar, Mumbai-Maharashtra
TDR : 56006092
Tender Notice
BOQ
20 Days Left
Hbni, Anushaktinagar, Mumbai
Maharashtra
Tender For Replacement Of Precision Air Conditioners ( Pac) Of Hbni Server Room And Other Miscellaneous Work , Anushaktinagar, Mumbai -94.
Name of Work:- Replacement of Precision air conditioners ( PAC) of HBNI Server room and other miscellaneous work , Anushaktinagar, Mumbai -94.
Sl. No.
Item Description
1
Dismantling and shifting of existing Precision air conditioners (TSS-1).
2
Supply, installation, testing and commissioning of floor mounted, bottom discharge precision air conditioners of nominal cooling capacity greater than 20 TR as per technical specification ( TSS-2).
3
Supply and installation of initial charge of eco-friendly refrigerant gas as per technical specification ( TSS-3).
4
Supply, installation, testing and commissioning of interconnecting 18 SWG hard copper piping between indoor and outdoor unit as per technical specification ( TSS-4).
5
Supply, installation, testing and commissioning of thermal insulation of interconnecting copper piping between indoor and outdoor unit as per technical specification ( TSS-5).
6
Supply and installation of interconnecting flexible copper cabling between indoor and outdoor unit , 3 core x 2.5 sq. mm. as per technical specification ( TSS-6).
7
Supply and installation of insulated PVC drain piping of 40 mm dia. as per technical specification ( TSS-7).
8
Supply and installation of aluminium volume control , multi louvered dampers as per technical specification ( TSS-8).
9
Supply and installation of GI perforated tray of 300 mm width and 75 mm height as per technical specification ( TSS-9).
10
Supply, fabrication and installation of MS structure as per technical specification (TSS-10).
11
Supply, fabrication and installation of fire retardant flexible canvass connections constructed between PAC unit and dampers / ducting of required size as per technical specification (TSS-11).
12
Supply and installation of communication cable for PAC sequencing , 0.75 sq. mm , 3 core shielded cable.
13
Supply, installation, testing and commissioning of floor mounted, tower type split air conditioner of nominal cooling capacity 3 TR as per technical specification ( TSS-12)
14
Supply, installation, testing and commissioning of butterfly valve of 150 mm dia as per as per technical specification ( TSS-13) Please Enable Macros to View BoQ information