| 1 | MATERIALS FOR 11 KV Cut Point with 90 Degree AngleH W fitting(B&S) 70KN, 3Bolt |
| 2 | Disc insulator (B&S) 70 KN polymer |
| 3 | WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR |
| 4 | POLYCARBONATE BIRD GUARD |
| 5 | MATERIALS FOR 11 KV Pin Points With WPB80 sq.mm AAA conductor |
| 6 | SUPPLY OF FOLLOWING EQUIPMENT & MATERIALS WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)-DP(Total Pole Weight with Base Plate & Stiffner=334.84 KG+10.74 KG= 345.58 KG) |
| 7 | Top Channel(GI) GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg) |
| 8 | Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280) |
| 9 | AB Switch Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg) |
| 10 | AB Switch Side Support Channel(GI) 100X50X6mm,9.56 KG/Mtr., each Channel(GI) length 0.35 mtr., 2 no's Channel(GI) required =( 9.56x2x0.35) |
| 11 | Channel(GI) Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 0.8 Mtr., 1 no's Channel(GI) required =( 7.14x0.8x1) |
| 12 | HG/ DO Fuse Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg) |
| 13 | Cantilever Support Channel(GI) 75x40x4.8 mm GI Channel(GI) (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg) |
| 14 | Cantilever Support Angle(GI) 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg) |
| 15 | Transformer Base GI Channel(GI) 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg) |
| 16 | Transformer Base Support GI Channel(GI) 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg) |
| 17 | Transformer Belting Angle(GI) 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg) |
| 18 | Transformer Belting Support Angle(GI) 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Kg) |
| 19 | LTDB Mounting Angle(GI) 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg) |
| 20 | 50x6mm Flat(GI) for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg) |
| 21 | 100 KVA , 11/ 0.4 KV (AL) Transformer, BIS Energy Loss level II, Ammendment-4 |
| 22 | LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 100 KVA S/S |
| 23 | 55 SQ.MM. AAAC XLPE Covered Conductor |
| 24 | 4 Cx 150 mm2 LT XLPE Cable(Armoured) - FOR 100 KVA Trf. |
| 25 | AB Switch(11KV,200A.3pole,50Hz) |
| 26 | H.G.Fuse( 11KV.200A.3Pole) |
| 27 | WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR |
| 28 | POLYCARBONATE BIRD GUARD |
| 29 | Disc insulator (B&S)70 KN polymer |
| 30 | H W fitting (B&S)70KN(3bolted) |
| 31 | Lightning Arrester(12KV,10KA) Station Class 2 |
| 32 | 11KV pin insulator polymer |
| 33 | HT stay set complete |
| 34 | HT stay Clamp (1.9Kg/pair) |
| 35 | HT stay insulator TYPE-C |
| 36 | 7/10 SWG GI stay wire, Grade -2 (15Kg./ Set) |
| 37 | 40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long |
| 38 | GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP) |
| 39 | GI Barbed wire/Anticlimbing device (3Kg /Pole) |
| 40 | Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 8 no's = (8x0.59x0.510) |
| 41 | Danger plate 11kv |
| 42 | Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 2 no's = (2x0.59x0.510) |
| 43 | Name plate |
| 44 | Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background |
| 45 | Black Colour Paint(GIS Numbering & Zebra Stripping) for numbering |
| 46 | Civil and Services WorksConcreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1800mm) = 0.450Cu.mtr(Per Pole) (For WPB Pole) |
| 47 | Couping ratio 1:1.5:3(M-20 Grade) (500mmX500mmX450mm) = 0.113Cu.mtr(Per Pole) |
| 48 | PCC ratio 1:3:6(M-10 Grade) For DSS Area (5X3X0.1)= 1.5 Cu. mtr. |
| 49 | Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6(M-10 Grade) size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator . |
| 50 | Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earthresistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI)around pipe . |
| 51 | Laying of 4 Cx 150 mm2 LT XLPE Cable |
| 52 | SITC and Erection of GI Fencing with Gate |
| 53 | Supply of AL Lugs suitable for 150 sq mm cable/conductor, Crimping with cable and Fixing/connecting include supply and erection of PVC Tape as per voltage requirement. |
| 54 | Supply and erection of double Compression Flameproof Type Glanding for armored Cable 3.5/4C 120-185sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly .Supply to be done as per TPCODL Spec and approved make dowells. Please Enable Macros to View BoQ information |