| 1 | Total amount of the \\"Rate Schedule\\" sheet SCHEDULE OF QUANTITY AND RATE FOR GIVING 800 KVA NEW CONNECTION TO M/S UUSDA FOR SEWERAGE TREATMENT PLANT, KUANWALA UNDER EDSD, BALAWALA UNDER EDD, RAIPUR AGAINST E-TENDER SPECIFICATION NO.34/EDCRDDUN/2026-27 Name of The Bidder's Firm: 0.0 Sl. No. Description of Work Unit Qty Rate Amount Part [A] (Supply Portion) |
| 2 | 11 KV H.S. Kit 3x120 mm. (Indoor type) |
| 3 | 11 KV H.S Kit 3x120 mm. (Outdoor type) |
| 4 | 11 KV H/S Jointing Kit 240 sqmm. (I/D) |
| 5 | 11 KV H/S Jointing Kit 240 sqmm. (O/D) |
| 6 | Bolt & Nuts off size |
| 7 | Insulated Electrical Piller Taparia |
| 8 | G.I. Earth Strip 65x6 mm. |
| 9 | G.I. Strip 40x6 mm. |
| 10 | KM 21 150 W HPSV Led with All Accessories |
| 11 | Rubber Mat (Chaquired Shet) 5 mtr x3 mtr. 12 mm. |
| 12 | Sundry Item Lug Glade etc. |
| 13 | Battery 12 V |
| 14 | Dange Board |
| 15 | Perforated Tray 200 mm. for Cable trench |
| 16 | 11 KV VCB Panel |
| 17 | 33 KV CT PT Combination with Meter Box 200/1A |
| 18 | Fire Extinguisher |
| 19 | D- Sapnner Set upto 32 mm. |
| 20 | 33 KV XLPE HS Jointing Kit 3x300 sqmm. Straight |
| 21 | Wall Clock |
| 22 | Control Panel Inc 33 KV Double Circuit |
| 23 | 33 KV XLPE HS Jointing Kit 3x300 sqmm. (Straight) |
| 24 | Name Plate of Equipment TG LI BI CT CB etc. |
| 25 | 11 KV Hand Gloves |
| 26 | 33 KV Hand Gloves |
| 27 | First Aid Box |
| 28 | Trolly Stand for Invertor & Battery |
| 29 | Shock Treatment Chart |
| 30 | Shutdown Breakdown Board |
| 31 | Pipe Wrench 12 |
| 32 | Instruction Board |
| 33 | Maximum & Minimum Display Board |
| 34 | Sub-Station Named Board |
| 35 | Single Line Diagram Board |
| 36 | Earth Chain (Brass) |
| 37 | Steel Almirah |
| 38 | Steel Cabinet |
| 39 | Steel Chair |
| 40 | Meggar 5 KV Digital |
| 41 | Invertor |
| 42 | Steel Office Chair Godrej |
| 43 | Spring Charging Mechanism 33 KV VCB |
| 44 | 33/.04 33 KV 25 KVA T/F . 0.0 Part [B] (Labour Portion) |
| 45 | Cartage of ST pole from store centre to construction site with loading, unloading at both points. (loading, unloading pluse carriage per pole) and proper stacking. (0-20 Km.) SP-72 Nos 1.0 0.0 SP-55 Nos 12.0 0.0 |
| 46 | Head load cartage of following Poles from road to site Upto 0 to 1 Km. SP-72 No. 1.0 0.0 |
| 47 | Erection of Bus Isolator Structure |
| 48 | Supply and Laying of HDPE Pipe |
| 49 | Erection of 33 KV Control Panel (feeder /transformer ) |
| 50 | Erection of following Double support pole in proper level and alignment alongwith fixing of all accessories, like top channel, X-bracing & clamps as per RESSPO construction Manual. SP-72 Nos 1.0 0.0 SP-55 Nos 5.0 0.0 |
| 51 | Grouting of pole in size 0.45x0.45x1/9 of the support in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement,sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO construction Manual. |
| 52 | Muffing of poles size 0.45 cm x 0.60 cm radious with cc 1:3:6 (1 cement : 3 coarse sand : 6 graded stone 10mm nominal size) block size 45cm height from ground level including cost of cement, stone and sand etc. |
| 53 | Dismantling of existing LT/HT line. including disc fitting, Insulator, clamps, Nut & Bolts and consumer connections and Street light connections etc. including rolling of conductor and cartage back from site to JE store Single pole PCC Pole Nos 1.0 0.0 Double pole PCC Pole Nos 1.0 0.0 SP-55 Nos 3.0 0.0 |
| 54 | Dismantling of Transformers from double pole /plinth including opening of all connections, circuts & earthing strip etc. 100 KVA Nos 1.0 0.0 |
| 55 | T-off Connection Complete 11 KV line |
| 56 | T-off Connection Complete 33 KV line |
| 57 | Mounting & Fixing of TPMO on double pole structures including making of connections complete work |
| 58 | Mounting & Fixing of Fuse sets on double pole structures including making of connections complete work |
| 59 | Mounting and Fixing of Lightning arrestor set (3 Nos.) on double pole structure including making all connections by G.I. strip size 35x6 mm to earth point complete work (excluding cost of G.I.Strip) |
| 60 | Laying of Dog conductor in HT Line |
| 61 | Fixing of 11 KV XLPE Jointing Kit |
| 62 | Fixing of 33 KV XLPE Jointing Kit |
| 63 | Fixing of 33 KV XLPE Straight Through |
| 64 | Erection of 11 KV VCB ( O/G or B/C or I/C ) Panel |
| 65 | Manual Shifting of 11 KV VCB O/G |
| 66 | Cartage of the following capacity transformers from store center to construction site with loading and unloading at both points. (Loading, unloading plus carriage of T/F). (0-20 Km) 11 KV panels Nos 6.0 0.0 |
| 67 | Cartage Power Transformer by Road. (0-20KM) 1.5/3 MVA Power T/F Nos 1.0 0.0 |
| 68 | Shifting of 5/3 MVA Power Transformer from road site to work site / store center to loading site place with the manual pulling |
| 69 | Loading of (3/1.5) MVA Transformer at Sub Station in Vehicle. |
| 70 | Unloading of (3/1.5) MVA Transformer at Sub Station complete. |
| 71 | Erection of power T/F(3/1.5 MVA) |
| 72 | Erection of cable/neutral stand |
| 73 | Laying of U/G 11 KV Cable in trench |
| 74 | Route cleareance by cutting of tree branches / proning, lopping and chopping of trees for L.T., 11 & 33 KV line. |
| 75 | Supply and Fixing of GI Pipe (with Socket) 6 inch Dia as per site requirement |
| 76 | Installation /Fixing of 33 KV Isolator |
| 77 | Digging of Pit for Trench 0.6 x 0.15 x 1.5 m |
| 78 | Laying of U/G 33 KV Cable(trecnchless) |
| 79 | Making Special type separate earthing for neutral /body of Power transformer by digging 3x4x12 feet deep pit at corner of Swithchyard with duly provided 1 No. coal Iron earth plates of size 18''x18''x½'' jointing them with 6'' long bolt duly coverod with layer of softcoal 60 Kg. and salt 20 Kg. (Total 80 Kg.) connecting them with the main erath mat, The earth plate shall be connected with 35x6 mm GI Strip and GI strip shall be laid upto the neutral and T/F body separately (Including supply of steel). |
| 80 | Fabrication of M.S. Channel Angle iron after cutting in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESSPO sehedule and local approved drawing. |
| 81 | Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 82 | Erection of following Single support pole in proper level and alignment alongwith fixing of all accessories, like top channel & clamps as per RESPO construction Manual. SP-55 Nos 2.0 0.0 |
| 83 | Fixing of RCC cable route marker Including cost material |
| 84 | Painting of Isolator/LA/CT/Structure |
| 85 | Providing and fixing of Danger Board and number plate complete by providing clamps of M.S. Flat 50x6 mm and Nuts & Bolts, danger Boards of M.S. Sheet 2 mm Thick 11''x7'' size (Including cost of all material) |
| 86 | Charges for Civil Work (As per Annexure-1 of BOQ) |
| 87 | Installation Stand of Chuggi etc. |
| 88 | Supply & Fixing of Fire Bucket |
| 89 | Erection of 33/0.4 33 KV 25 KVA Sub-Station Transformer |
| 90 | Supply & Erection Gravel Pitching 1/2 -3/4 |
| 91 | Construction of Transformer Plinth with size 2x2x1.1 meter above ground level and 0.6 meter below ground level including the cost of material such as cement, brick, ballast, sand etc. complete work as RESPO norms. Excavation of earth of size 2.1x2.1x1.2 meter Cum 3203.0 0.0 Cement concreting work in ratio 1:4:8 Cum 65320.0 0.0 Brick work in 1:4 ratio Cum 88400.0 0.0 RR massonary work in 1:6 ratio Cum 64050.0 0.0 RCC Work of 1:2:4 ratio 15 cm thickness Cum 87110.0 0.0 Cement Plaster on side walls in 1:4 ratio Sqm 16.0 0.0 |
| 92 | Opening & Making of Jumper of Section Pole |
| 93 | Erection, providing and fixing of wire mesh of size 50x35 mm around plinth and toe wall duly welded with frame of M.S angle iron 35x35x6 mm and strip of size 35x6 mm in mid of each side along with wire mesh (width of wire mesh 1.5 meter ) with the height of 0.5 meter above the plinth and 2 meter above the toe wall with 1 No. gate and locking arrangment in the toe wall size including grouting of 6 Nos. legs in the ratio in block of size 0.25x0.25x0.45 meter including gravlling of shingle of size 20 to 40 mm and complete painting of wire mesh with aluminium paint with two coat (Including the cost of cement and all material) |
| 94 | Erection of 33 KV Vaccum Circuit Breaker in all respect, making connection including testing and commissioning. |
| 95 | Installation / mounting of new Tranformer on plinth pole structure and fixing of channel / angle etc. and making all connections of HT and LT side and its complete commissioning. On Double Pole 100 KVA Nos 1.0 0.0 Total - Part [B] 0.0 TOTAL [Part-(A) + Part (B)] 0.0 Place Date Superintending Engineer Annexure-1 ABSTRACT OF COST Name of Work :- Construction of S.G.R. Building and other related works SL.NO. ITEM OF WORK DSR CODE UNIT QTY |
| 96 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 97 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5m |
| 98 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 99 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level . 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 100 | Providing and laying in position cement concrete in ratio 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 101 | Providing and laying in position specified grade of reinforced cement concrete in ratio 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level |
| 102 | Reinforced cement concrete work in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement. |
| 103 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 104 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 105 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. |
| 106 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 107 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 108 | Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 109 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges. |
| 110 | Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level including the cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces but excluding the cost of reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 111 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. |
| 112 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 113 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 114 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 115 | Half brick masonry with F.P.S. brick of class designation 75 in foundations and plinth in. cement mortar 1:4 (1 cement : 4 coarse sand) |
| 116 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level. |
| 117 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab upto 0.50 sqm |
| 118 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work |
| 119 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 120 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete….With 12 mm mild steel U beading |
| 121 | Strutural steel work riveted bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 122 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.: ---Hot finished welded type tubes |
| 123 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. |
| 124 | Steel work welded in built up sections/ framed work including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 125 | Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 1 O mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 1 O mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame • concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 126 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate. |
| 127 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick. |
| 128 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 129 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 130 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.75 mm diameter |
| 131 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.110 mm diameter |
| 132 | 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) |
| 133 | 15mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1cement :6 coarse sand) |
| 134 | 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. |
| 135 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.New work (two or more coats) over and including priming coat with cement primer. |
| 136 | Finishing walls with textured exterior paint of required shade for new work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 137 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 138 | Forming groove of uniform size from 12x12mm and upto 25x15mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. |
| 139 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 140 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
| 141 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 142 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 143 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm |
| 144 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. --- 10 litre capacity - White |
| 145 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 146 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe-----32 mm dia |
| 147 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 148 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P. brass screws with concealed fitting arrangement of approved quality an colour. 450mm long towel rail with total length of 495mm 78mm wide and effective height of 88mm, weighing not less than 170gms. |
| 149 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall..15 mm nominal dia Pipes |
| 150 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall 20 mm nominal dia Pipes |
| 151 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore |
| 152 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore |
| 153 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 154 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :15 mm nominal bore |
| 155 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 156 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore. |
| 157 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15 mm nominal bore |
| 158 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 a(15mm nominal bore) |
| 159 | Providing and fixing PTMT grating of approved quality and colour. Circular type. 100 mm nominal dia. |
| 160 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. |
| 161 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For.... fixed portion Powder coated aluminium (minimum thickness of powdercoating 50 micron) |
| 162 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powdercoating 50 micron) |
| 163 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. |
| 164 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):: With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm) |
| 165 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 166 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with moduler type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group B |
| 167 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required :2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 168 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required :2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 169 | Supplying and fixing followingModular type switch/ socket on the existing switch box/ cover including connections : 5/6 amps switch |
| 170 | Supplying and fixing following Modular type switch/ socket on the existing switch box/ cover including connections : 3 pin 5/6 amp socket outlet |
| 171 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 172 | Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess including providing and fixing 6 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required(For light plugs to be used in non residential buildings). |
| 173 | Supplying and fixing suitable size GI box with modular plate and cover in front on ...... providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. |
| 174 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 175 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 176 | supply and fixing following way, single pole and neuteral, sheet steel, MCB distribution board cosumer unit, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, hinged frount acrylic cover for the MCB knobs, detachable gland plate, interconnection, phosphatized and powder painted including earthing etc. as required. ( But without MCB/RCCB/Isolator ) 2+12 way |
| 177 | Supply and fixing 5 amps to 32 amps rating, 240 volts, 'C' serise, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and neutral |
| 178 | Supply and fixing following rating, 63 amps double pole, 240 volts, isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. |
| 179 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 180 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 181 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, earthing etc. complete as required. Please Enable Macros to View BoQ information |