| 1 | Supply of following |
| 2 | PVC cable 120 mm2 |
| 3 | ACCESSORIES OF LT AERIAL BUNCHED CABLESuspension Clamp (35-50mm) |
| 4 | ACCESSORIES OF LT AERIAL BUNCHED CABLEDead end Clamp (35-50 mm) |
| 5 | ACCESSORIES OF LT AERIAL BUNCHED CABLEService Anchor Clamp (18-50mm) |
| 6 | ACCESSORIES OF LT AERIAL BUNCHED CABLE3-Ph. Dist. Box (25-50 mm) |
| 7 | ACCESSORIES OF LT AERIAL BUNCHED CABLEIPC Main 16-95 Sq. mm &Tap 4 to 35(50) Sq. mm |
| 8 | ACCESSORIES OF LT AERIAL BUNCHED CABLE -Cable Ties |
| 9 | ACCESSORIES OF LT AERIAL BUNCHED CABLE -Eye Hook |
| 10 | ACCESSORIES OF LT AERIAL BUNCHED CABLE -Pole clamp (25/50 mm) |
| 11 | Rewireable Porcelain Cut out 200 Amp |
| 12 | 11KV Polymer Disc Insulator |
| 13 | 11KV Polymer Pin Insulator |
| 14 | L.T. Stay insulator |
| 15 | 11Kv stay insulator |
| 16 | 11KV disc fitting upto 7/3.8mm, 2-U Bolt type |
| 17 | 11KV Gang operated switch (Polymeric type) |
| 18 | Lighting Arrester 9KV, 5KA polymer LA |
| 19 | Stay set complete |
| 20 | GI stay wire 3/12SWG |
| 21 | NUTS and BOLTs 16X75mm(3) |
| 22 | NUTS and BOLTs 16X90mm(4) |
| 23 | Streps with Nuts and Bolt |
| 24 | Danger Plate HT |
| 25 | 11KV DO Fuse 3 phase |
| 26 | 11 KV Covered Conductor (70 SQMM) |
| 27 | Insulating Piercing Connector for 11 kV CC to CC 70 sqmm |
| 28 | Non-metallic helical ties for covered conductor 11kV |
| 29 | 11 KV Disc insulator Tension Hardware , 45 KN suitable for stringing Covered Conductor inc all accessories |
| 30 | Channel 100x50x6mm (Galvanised) |
| 31 | Channel 75x40x6mm (Galvanised) |
| 32 | Angle 50X50X6mm (Galvanised) |
| 33 | Angle 65X65X6mm (Galvanised) |
| 34 | Aluminium Lugs 120mm sq |
| 35 | Supply of Megger 1000VA |
| 36 | Supply of Clamp Meter |
| 37 | LT arrial Bunch Cable 3X70 1X50 1X65sqmm |
| 38 | 9 Mtrs Full Gulvanised Pole (410 SP-32) |
| 39 | Insulating Piercing Connector for 11 kV CC 70 sqmm to Bare 75-150 sqmm |
| 40 | 8 Mtrs Full Gulvanised Pole (410 SP-15) |
| 41 | Erection of following |
| 42 | Erection of 9.0mtrs length of Full Gulvanised POLE at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with withsoil upto the ground level, ramming and making completein all respect |
| 43 | Erection of 8.0mtrs length of Full Gulvanised POLE at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with withsoil upto the ground level, ramming and making completein all respect |
| 44 | Erection of complete Stay Set direct in earth complete with 19mmx1800 mm long stay rod anchor plate of size 300x300x8 mm thimble turn buckle 7/3.15mm dia G.I standed stay wire and stain screw, insulator etc with supply of M.S clamp, Nuts & bolt etc as required to complete the job |
| 45 | Erection of M.S.Channel Cross-Arm,0.3 to 1.2 Mtr.Long75 x40 x 40 x 6 mm ( Excluding the cost ofBack Clamp, Nuts & Bolts) |
| 46 | Erection of M.S.Channel Cross-Arm,0.6 to 2.8Mtr.Long100 x50 x 50 x 6 mm ( Excluding the cost ofBackClamp, Nuts & Bolts) |
| 47 | Erection of M.S.Angle Cross-Arm,1.0 to 2.8 Mtr.Long 65 x65 x 6 mm ( Excluding thecost of BackClamp, Nuts &Bolts) |
| 48 | Erection of M.S.Channel Cross-Arm,1.3 to 2.8 Mtr.Long75 x40 x 40 x 6 mm ( Excluding the cost ofBack Clamp, Nuts & Bolts) |
| 49 | Erection of 11KV Pin insulator along with Pin. |
| 50 | Erection of 11KV Single Disc insulator set along with necessary fittings |
| 51 | Earthing with G.I pipe 2.5mtr. Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing (excluding supply of G.I.Pipe, Salt & Charcoal, Gi wire, nuts &boIts, etc. as required) |
| 52 | Laying of 8 SWG GI wire at 300mm below the ground level for earthing of Sub-Station equipments from the earth electrode |
| 53 | Supply of 60Kg Salt & 55Kg Charcoal ( For 1 Pit). |
| 54 | Supply of M.S.Nuts & Bolt i/c Washer of assortedsize ISI Marked machine made |
| 55 | Febrication of Cross-Arms by MS Channel/MS Angle as per specification |
| 56 | Erection of 11KV DOF unit set of three nos. including necessary connection complete as per technical specification. (Excluding the cost of back clamp, Nuts & Bolts) |
| 57 | Erection of 11KV 200 Amp. GOS unit set of three nos. including necessary connection complete as per technical specification.(Excluding the cost of back cIamp,Nuts & Bolts) |
| 58 | Installation/Positioning of 1J/0.430KV,3-Phase 100 KVA ofDistribution Transformer on Pole with necessary connections & fitting fixing of all allied accessories components as required for making complete inall respect for energizing |
| 59 | Carriage of 11/0.430, 3-Phase 100KVA transformer by Mechanical Transport from the Site /Store/Worshop to working site Vis-a-vis including loading, unloading and placing on base, as required, a) Upto the lead range 25KM From MMD Store to Sub DivisionStore |
| 60 | Fitting-Fixing of Service main 1/3Phase distributionBox of 1.1 KV grade on PCC/Steel Pole with the help Pole brackets or Steel Straps &buckIes asperdirection of Engineering In-Charge. |
| 61 | Positioning of cable drum, removing of cable fromdrum and Laying, hoisting & drawing of AB Cable3X70-95+1x16-25+1x50-95sqmm of 101 KV gradeas per direction of EngineeringIn-Charge. |
| 62 | Erection & Fitting-Fixing of Insulated suspentionClamp including Pole clamp, Eye hook for cable massenger of 1.1 IV grade on PCC/Steel Pole with the help Pole brackets or Steel Straps &buckIes asper direction of Engineering In-Charge. |
| 63 | Erection & Fitting-Fixing of Insulation Piercing Connectors(IPC) all sizes of 1.1 IV grade including connection from main cable to Distribution box, Tee-Off line asper direction of Engineering In- Charge. |
| 64 | Maintaining adequate clearance from overhead live conductors by Trimming of tree branches for Way Leaves |
| 65 | Erection & Fitting-Fixing of Insulated Dead end enchoring Clamp including Pole clamp, Eye hook for cable massenger of 1.1 KV grade on PCC/Steel Pole with the help Pole brackets or Steel Straps &buckIes asper direction of EngineeringIn-Charge. |
| 66 | Erection of Fencing with Supply of Fencing Materials-Providing 1.8 mtr height chain link fenching around substationareas with angle post 65X65X6mm placed every 2.5 mtr apart embeded in cement concret block of 30X30X60mm of 1:3:.6 (1 cement : 3 river sand: 6 jhama brick aggregate 20mm. nominal size) and every 12th post and corner post to be shrutted and embeded in cement concrete block of 45X45X60mm of same mix, both two post should be fitted with GI stapple of M.S flat of 6mm. Two suitable gates made of 50mm dia GI pipe and chain link are to be provided within substation fenching (width of gate shall be 4 mtr and height1.8 mtr and the 2nd gate of 1.2mtr width 1.8 mtr height. |
| 67 | Stringing of 11KV Covered Conductor 70 sqmm (all 3 phases) as per specification and approved drawings, stringing of covered conductors at proper tension/ sag, fitting and fixing of all accesories Piercing Connectors , Jointing Sleeves, insulator binding using approved Non-metallic helical ties, jumpering, connections to other lines etc. complete in all respect. |
| 68 | Grouting of 9mtr long S.T.P pole 0.273 cum/pole |
| 69 | Grouting of 8mtr long S.T.P pole 0.273 cum/pole |
| 70 | ERECTION OF CUT OUT WITH CABLE CONNECTION |
| 71 | Fitting ,fixing of Wooden Plank For Cut Out with clamp nut &bolt rtc as required Please Enable Macros to View BoQ information |