| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8146/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: PROVISION OF FLOOR TILES, ALUMINIUM SLIDING WINDOWS AND ELECTRICAL FITTINGS AND FIXTURES AT ROOM NO.35 OF CQA (ICV) YEDDUMAILARAM, OFFICE PREMISES UNDER GE GOLCONDA Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and as directed |
| 3 | M&L Vitrified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with coloured cement matching with surfaces of tiles as in floor 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and as directed complete all as specified and as directed |
| 4 | All as per item No 02 above but for vertical surfaces such as skirting, dados and riser to steps over 10mm thick backing coat in cement plaster 1:3 finished even and fair to receive tiles. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 6 | Supply and fix Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors frames, shutters windows frames sliding shutters, ventilators, grills and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. Note : 4mm thick sheet glass & wire cloth will be measured and paid separately |
| 7 | S&F 4 mm thick sheet glass, ordinary quality, and sheet glass is ground or obscured or frosted on one side fixed in aluminium door/window/ventilator glazing with rubber beading complete all as specified and as directed. |
| 8 | S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.00 mm & fixed with stainless steel wire, staples all as specified and directed. |
| 9 | Dismantling Stone slabs and tiles of any description or thickness in floors, plinth protection, aprons etc. Laid, bed-ded and pointed in any mortar,complete all as specified and as directed. |
| 10 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 11 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. |
| 12 | Taking down cement plaster on wall of any description including racking out joints for key, scrubbing with water etc. complete all as specified and as directed. |
| 13 | M & L for rendering, 15mm thick in two coats, first coat 10mm thick in CM (1:6) and second coat 5mm thick in CM (1: 4) on concrete or brick wall surfaces, finished even and smooth without using extra cement, mixed with WPC @ at 2% by weight of cement (IWPC measured and paid separately) complete all as specified and as directed. |
| 14 | Supply only integral water proofing compound. |
| 15 | M & L for rendering 10mm thick in cement mortar 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and as directed. |
| 16 | M&L for two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surfaces of walls including 3mm thick wall care putty on wall and preparation of surface complete all as specified and as directed. |
| 17 | M&L for preparing new plastered surfaces of walls and applying Two coats of cement based paint over a coat of primerr complete all as specified and as directed. |
| 18 | Taking down carefully existing point wiring of any description for light, fan, sockets bells etc.) complete including fittings such as sunken boxes, switches, sockets, ceiling rose, lamp holders, brackets, fittings, fan regulators etc. and making good the disturbed surface of walls, floors etc. all as specified and directed. |
| 19 | Taking down existing sub main wiring /Service wire of any description and size including earth wire, batten, conduits and making good the disturbed surfaces of walls, floors etc. |
| 20 | M & L for providing point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLS unsheathed copper conductor cable (maintaining colour code), 1100 volts grade in and including non metallic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for concealed wiring on stone/brick, masonry walls, roof etc. including modular sunken box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fan /bell point controlled by one one-way modular switches including one run 1.5 sqmm (nominal area) PVC insulated FRLS unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly including cutting/running chases, pinning and making good the disturbed surfaces to match with the existing specification, complete all as specified & directed at site. |
| 21 | All as per item No.19 above but one 5 Amps 3/5 pin modular socket outlet on independent board complete all as specified and as directed at site. |
| 22 | All as per item No.19 above but for one 3/5 pin 5/6 Amps modular socket outlet on point same board with other switches complete all as specified and as directed at site. |
| 23 | All as per item No.19 but for One 3 15 / 16 Amps modular switch socket outlet point on independent board with 2.5 sqmm (PVC (FRLS) insulated conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and as directed at site. |
| 24 | S&F in repair Ceiling rose surface bakelite 65 x 50 mm 2/3 terminals complete all as specified and as directed at site. |
| 25 | S&F in repair Modular switch, single pole, one way, 6 Amps one module complete all as specified and as directed at site. |
| 26 | S&F in repair Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and as directed. |
| 27 | S&F in repair Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed. |
| 28 | S&F in repair Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed. |
| 29 | S&F in repair modular stepped type electronic fan regulator 220 volts, 100Watt complete all as specified and as directed. |
| 30 | S&F in repair Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 12 Ways, double door including taking down of existing sheet metal enclosure complete all as specified and as directed at site. |
| 31 | S&F in repair 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 32 | S&F in repair 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed |
| 33 | M&L for Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 6.0 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in and including PVC conduit medium grade/casing capping with all fittings suitable for concealed/surface type and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and as directed |
| 34 | S&F LED down lighter 2'x2', 36 W environmental friendly, new generation, aesthetically designed, ultra modern surface mounting luminaire with high brightness SMD LEDs as light source complete all as specified and as directed. Make: Havells Cat No. PLANOSUR2X2PL36WLED840G2S or techno commercially equivalent make as approved by GE. |
| 35 | Disconnecting the electric supply and taking down ceiling fan of 1200/1400mm sweep from any height, sealing cable end, dismantling blades and removing fan and blades and deposit to MES store etc., complete all as specified and as directed. |
| 36 | M&L for Painting of ceiling fans complete, in site with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and as directed. |
| 37 | Hanging/Fixing of ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed. |
| 38 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point including necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead testing after completion complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |