| 1 | NS Item -NS item- Art work and wall painting on the external and internal walls of office buildings, schools, and public/community toilets, Community Centre, including necessary plaster repairs, wall putty, surface preparation, and painting, complete in all respects. The work shall include the supply of all materials, labour, tools, plants, scaffolding, and equipment required for proper execution of the work. The contractor shall also provide GPS-enabled photographs before commencement and after completion of the work, as per directions of the Engineer-in-Charge. |
| 2 | NS Item -Supply, Installation, Testing and Commissioning of 1000 LPH R.O. Water Purifier Plant suitable for raw water having TDS up to 4000 PPM in Municipal Committee Kalanaur.Sr. No. Description Qty1. SS-202 Skid, 1000 LPH, 1` =1 No.2. Raw Water Pump (CRI Royal 1 HP) =1 No.3. FRP Vessel 1354 C-Flow =2 Nos.4. Multi Port Valve (MPV) 1` TMF BK =2 Nos.5. Sand Media =150 Kg6. Activated Carbon Media =25 Kg7. Installation Kit =1 Lot8. Anti-scalant Arrangement =1 Set9. Low Pressure Switch (LPS) =1 Nos.10. High Pressure Switch (HPS) =1 Nos.11. Housing 20` BB, 1` =1 Nos.12. Spun Filter Candle 20` BB =2 Nos.13. RO Membrane URN 4040 =4 Nos.14. FRP Membrane Housing 4040 =2 Nos.15. High Pressure Pump CRI 2/19 MTP =1 Nos.16. Rotameter 2400 LPH =2 Nos.17. Pressure Gauges =2 Nos.18. Control Panel with TDS Meter =1 Nos.19. Dosing Pump =1 Nos.20. Anti-scalant Chemical =5 Litres21. Astral UPVC Piping and Fittings =1 Lot22. Labour, Testing and Commissioning =1 Job23. RO System suitable for Raw Water TDS up to 4000 PPM =Complete |
| 3 | NS Item -Supply and Erection of 7.5HP Open Well Submersible Pump, 3 phase to complete the work complete in all respect up to entire satisfaction of engineer-in- charge. (Make: - Texmo| Jindal| V-Guard |Havells) |
| 4 | HSR Item 6.25.1-Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge. 1. All works up to plinth levelHSR Rate(Rs.) 4464.00 Through Rate |
| 5 | HSR Item 6.30.5-Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantileversHSR Rate(Rs.) 296.00 Through Rate |
| 6 | HSR Item 10.62-Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.HSR Rate(Rs.) 570.00 Through Rate |
| 7 | HSR Item 6.30.3-Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platformHSR Rate(Rs.) 208.00 Through Rate |
| 8 | HSR Item 11.6.1-15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand)HSR Rate(Rs.) 138.00 Through Rate |
| 9 | HSR Item 7.22.1-Brick work with common burnt clay nonmodular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand)HSR Rate(Rs.) 4404.00 Through Rate |
| 10 | HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand)HSR Rate(Rs.) 113.00 Through Rate |
| 11 | HSR Item 10.100.2-Cement Concrete 1:8:16 Flooring 2. Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth.HSR Rate(Rs.) 1863.00 Through Rate |
| 12 | HSR Item 10.63.2-Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mmHSR Rate(Rs.) 987.00 Through Rate |
| 13 | HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soilHSR Rate(Rs.) 78.00 Through Rate |
| 14 | HSR Item 6.16-Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).HSR Rate(Rs.) 6113.00 Through Rate |
| 15 | HSR Item 7.21.1-Brick work with common burnt clay nonmodular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand)HSR Rate(Rs.) 4128.00 Through Rate |
| 16 | HSR Item 11.95.1-Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)HSR Rate(Rs.) 88.00 Through Rate |
| 17 | HSR Item 22.86.1-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia PipesHSR Rate(Rs.) 205.00 Through Rate |
| 18 | HSR Item 6.14.1-Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zoneIII): 3 graded stone aggregate 20 mm nominal size)HSR Rate(Rs.) 4374.00 Through Rate |
| 19 | HSR Item 6.15.1-Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zoneIII) : 3 graded stone aggregate 20 mm nominal size)HSR Rate(Rs.) 5969.00 Through Rate |
| 20 | HSR Item 6.29.3-Centering and shuttering including strutting, propping etc. and removal of form work for : 3. Columns, piers, abutments, pillars, posts and strutsHSR Rate(Rs.) 261.00 Through Rate |
| 21 | HSR Item 10.7-Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4HSR Rate(Rs.) 216.00 Through Rate |
| 22 | HSR Item 9.11.1-10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10HSR Rate(Rs.) 488.00 Through Rate |
| 23 | HSR Item 11.58-Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. completeHSR Rate(Rs.) 32.00 Through Rate |
| 24 | HSR Item 22.104.1-Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal boreHSR Rate(Rs.) 346.00 Through Rate |
| 25 | HSR Item 2.B2008- B2008. PVC blind pipe 200 mm dia as per IS: 12818HSR Rate(Rs.) 704.00 Rate |
| 26 | HSR Item 6.34.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more.HSR Rate(Rs.) 68.00 Through Rate |
| 27 | HSR Item 13.29.2-Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksHSR Rate(Rs.) 83.00 Through Rate |
| 28 | HSR Item 20.71.2-Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 2. 56\\" (1400mm)HSR Rate(Rs.) 2361.00 Through Rate |
| 29 | HSR Item 23.4.4.1-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.1. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group AHSR Rate(Rs.) 725.00 Through Rate |
| 30 | HSR Item 23.4.1.1-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group AHSR Rate(Rs.) 520.00 Through Rate Please Enable Macros to View BoQ information |