| 1 | Repair of automatic starter, delta starter installed at Filtration plants 1,2,3&4 at sitlee job involves replacing damaged air break contactor, repairing replacing damaged contact kits replacing damaged power contacts complete job with the cost of material and labour charges.40HP (Rate to be quoted by the contractor) |
| 2 | Repair of automatic starter, delta starter installed at Filtration plants 1,2,3&4 at sitlee job involves replacing damaged air break contactor, repairing replacing damaged contact kits replacing damaged power contacts complete job with the cost of material and labour charges.30HP (Rate to be quoted by the contractor) |
| 3 | 25HP (Rate to be quoted by the contractor) |
| 4 | 20HP (Rate to be quoted by the contractor) |
| 5 | 15HP (Rate to be quoted by the contractor ) |
| 6 | 10HP (Rate to be quoted by the contractor ) |
| 7 | Repair to DOL Starter by replacing its damaged over load relay / conductor and testing complete.7.50 HP ( Rate to be quoted by the contractor ) |
| 8 | 3.00HP ( Rate to be quoted by the contractor ) |
| 9 | 2.00HP ( Rate to be quoted by the contractor ) |
| 10 | 1.00HP ( Rate to be quoted by the contractor ) |
| 11 | Rewinding of induction motor pumps, blowers, gears, flash mixers and strirrers installed at Filtration plant no. 1,2,3&4 sitlee Job involves the dismantling of motor from bed plate loading and shifting the same to work shop extracting out damaged old winding from slots, insulting the slots properly making and fixing them into slots, making all coil connections, varnishing the stator reassembling the motor, shifting it back to site, fitting it and making proper alignment with pump making of necessary electrical connections and testing it at site on full load job involves cost of material and labour charges including to & from carriages after deducting the cost of material i.e old burnt copper wire 40HP (Rate to be quoted by the contractor) |
| 12 | 25HP (Rate to be quoted by the contractor) |
| 13 | 15HP (Rate to be quoted by the contractor) |
| 14 | 10HP (Rate to be quoted by the contractor) |
| 15 | 7.50HP (Rate to be quoted by the contractor) |
| 16 | 2.00HP (Rate to be quoted by the contractor) |
| 17 | 1.00HP (Rate to be quoted by the contractor) |
| 18 | Providing and installation of 3 Pole Main switches of heavy duty and standard quality confirming to ISI Standards 100AMP (Rate to be quoted by the contractor) |
| 19 | 63AMP (Rate to be quoted by the contractor) |
| 20 | 32AMP (Rate to be quoted by the contractor) |
| 21 | 16AMP (Rate to be quoted by the contractor) |
| 22 | Providing and fixing of 4.00 sqmm. 3 core copper cable for filtration plants, chemical houses (Rate to be quoted by the contractor) |
| 23 | Job for repair to blower installed at Filtration plants at Sitlee job includes dismentalling of blower to gear shaft by welding and turning and bearing size at both ends providing and fitting of new mains gear with pin replacement of demo foil Bearing 3208, 4nos oil seal 4 nos repair of body casing by drilling and topping, fitting of new studs and nuts. Job includes repair to pulley by bush fitting turning and boring and key way making job also includes all cost of material and key way making.(Rate to be quoted by the contractor) |
| 24 | Replacing damaged belts and bet bearing with cost of bearing and fitting charges on PS and CF Tanks.(Rate to be quoted by the contractor) |
| 25 | Supply and fitting of LED Lights 85 WATTS (Rate to be quoted by the contractor) |
| 26 | Supply and fitting of LED Lights 70WATTS (Rate to be quoted by the contractor) |
| 27 | Supply and fitting of LED Lights 56 WATTS (Rate to be quoted by the contractor) |
| 28 | Supply and fitting of LED Lights 40 WATTS (Rate to be quoted by the contractor) |
| 29 | 12 WATTS (Rate to be quoted by the contractor) |
| 30 | 18 WATTS (Rate to be quoted by the contractor) |
| 31 | Supply and fitting of LED Lights 20 WATTS (Rate to be quoted by the contractor) |
| 32 | Providing & laying of internal wiring 1.50 mm2 incl plastic batten. (Rate to be quoted by the contractor) |
| 33 | Providing & laying of 2.5 mm 2 multistand for filtration plant & chemical house.(Rate to be quoted by the contractor) |
| 34 | Providing 7 fixing of 6.00 sqm 3 core copper cable for filtration plants chemical house.(Rate to be quoted by the contractor) |
| 35 | Providing & fixing of 16.00 sqm 3 core copper cable.(Rate to be quoted by the contractor) |
| 36 | Providing & fixing of 10.00 sqm 3 core copper cable.(Rate to be quoted by the contractor) |
| 37 | Providing & installation of 4 pole main switches heavy duty and standard quality confirming to ISI Standards.MCB 125cc Amp (Rate to be quoted by the contractor) |
| 38 | Providing & Fixing of MCB With box (Rate to be quoted by the contractor)16 Amp |
| 39 | 32 Amp.(Rate to be quoted by the contractor) |
| 40 | Providing & Fixing of switches 5 Amp.(Rate to be quoted by the contractor) |
| 41 | Providing & Fixing of socket 5 Amp (Rate to be quoted by the contractor) |
| 42 | 15 Amp (Rate to be quoted by the contractor) |
| 43 | Providing & Fixing of combined switches 15 Amp.(Rate to be quoted by the contractor) |
| 44 | Providing & Fitting of Tube lights complete 18 Watt (Rate to be quoted by the contractor) |
| 45 | 24 Watt (Rate to be quoted by the contractor) |
| 46 | Providing & Fitting of Bulb Holder 7 Watt (Rate to be quoted by the contractor) |
| 47 | 9 Watt (Rate to be quoted by the contractor) |
| 48 | Providing & Fitting of thimble bush (Rate to be quoted by the contractor) |
| 49 | Providing & Fitting of Mica Sheets 9”X 6” (Rate to be quoted by the contractor) |
| 50 | Providing & Fitting of Mica Sheets 9”X 11\\" (Rate to be quoted by the contractor) |
| 51 | 11”x 13” (Rate to be quoted by the contractor) |
| 52 | Providing & Fitting of DP / Insulator 100 Amp.(Rate to be quoted by the contractor) |
| 53 | Supply of PVC Tape roll (Rate to be quoted by the contractor) |
| 54 | Supplying installation, testing and commissioning of LED Bulb on the existing angle holder as required ISI Mark 9 Watt. (Rate to be quoted by the contractor) |
| 55 | Supplying installation, testing and commissioning of LED Bulb on the existing angle holder as required ISI Mark 12 Watt. (Rate to be quoted by the contractor) |
| 56 | Supplying installation, testing and commissioning of LED Bulb on the existing angle holder as required ISI Mark 20 Watt. (Rate to be quoted by the contractor) |
| 57 | Supply, installtion, testing, and commissioning of ceiling fan 1200 mm, including wiring the down rods of standard length ( upto 30cm) as required ISI Mark.(Rate to be quoted by the contractor) |
| 58 | Supply, installtion, testing, and commissioning of exhaust fan including making good the damage (300mm shutter type) as required ISI Mark.(Rate to be quoted by the contractor) Please Enable Macros to View BoQ information |