| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge.All kinds of soil : |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Cold twisted bars |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls under 20 cm wide |
| 7 | Supply & Fixing of 40mm wide Pvc strips for joints |
| 8 | Providing & Laying PP (Polythene) tile approved by FIBA with minimum thickness of 15.5mm and weight not less than 320 gm/tile and other specification like, Ball Rebound, Slip resistance, force reduction as per parameters approved by FIBA. The contractor shall have to provide the unconditional warrenty of 8 years from the OEM or its Autorised Distributor in India and get the sample of tile Testeed from NABL, Accediated before payment. |
| 9 | Providing and fixing of fixed height adjustable poles (Minimum 3 inch) with net with line marking |
| 10 | Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 12 | Supply and laying of PVC Insoulated and PVC sheathead/ Xip aluminium power cable of 1.1 KV grade of following sizes on surface/ direct in ground incluidng sand cushoning protective covering and refilling the trench as required as per direction of Engineer-In-charge 16 sq.mm 2 core |
| 13 | Supply and laying of PVC sheated/xipe aluminium power cable of 1.1 KV grade of following sizes on surface/ direct in ground including sand cushoning protective covering and refilling the trench as requred as per direction of Engineer-Incharge 16 Sq.mm 2 core |
| 14 | Supply and fixing of followinjg sizes of mendium class PVC conduit along with accossories in surface/recess including cutting the wall and making good the same in case recessed conduit as required 20mm |
| 15 | Supply and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board-240 Volts, on surface/recess, complete with testing and commissioning etc. as required For 6 way, Double door SPN MCBDB |
| 16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, \\"C\\" curve, miniature circuit breaker suitable for incdective load of following poles in the existing MCBDB |
| 17 | Single Pole and Neutral 32 AMP |
| 18 | Single Pole and Neutral 63 AMP |
| 19 | Supplying, installation, testing and commissioning IP 67 Flood lights 200 Watt. Minimum Luminous Flux of Lummiaire 120 Lin/W, Colour temperature of 5700 K, Netural white, CRI> 80, 50,000 operating hours with PC lens and necessary wire for connection and other accessories required for fixing lights on existing plugs, Firm has to submit originally certificate of material from OEM or Authorized Distributor with 05 years of warranty. |
| 20 | Providing and fixing of ACP main board 3mm thickness on 1x1 inch tubular frame with writing of Name of stadium etc as per direction of Engineer-In-charge |
| 21 | Supplying, installation, testing and commissioning of 150/150 litres of water coller having full stainless steel body, colling capacity 150 ltr/hour and storage capacity 150 Ltr alongwith PVC connecting pipes as required Warantee, 3 years from the date of installation |
| 22 | Supplying, installation, testing and commissioning of the following type of water purifiers alongwith PVC connecting pipes as requred (RO+UV+UF mineral control with TDS control warrantee 3 years from the date of installation |
| 23 | Supplying, installation, testing and commissioning of the following capacity automatic voltage copper wound wall mounted single phase with range of 90-240 V alongwith wall mounting brackets & fitting. The job includes repairing the watts where necessary Warantee 3 years from the dater of installation |
| 24 | poroviding and placing for all floor levels polyethylene water storage tank ISI 12701 marked, with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes butt without fittings and the base support for tank |
| 25 | Providing and fixing G.I. pipes complete with G.I. fittings excludingtrenching and refilling etc. (external work) 15 mm dia. nominal bore (Medium) |
| 26 | Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete 15 mm nominal bore |
| 27 | Providing and fixing G.I. Union in G.I. pipe including cutting andthreading the pipe and making long screws etc. complete (new work) 15 mm nominal bore |
| 28 | Carriage of material by mechanical transport from source to the site of work including loading/unloading and stakcing complete. |
| 29 | Sand for an av. lead 95 Kms distance |
| 30 | Bajree/Stone aggregates below 40mm nominal size for an av. 35 Kms distance Please Enable Macros to View BoQ information |