| 1 | Wiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group C) (DSR 2022 code 1.8.3) |
| 2 | Supplying and fixing of following sizes of medium class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm (DSR 2022 code 1.21.1) |
| 3 | Supplying and fixing of following sizes of medium class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (DSR 2022 code 1.21.2) |
| 4 | Supply of 2.5 Sq mm of FRLS PVC insulated copper conductor, single core cable, 180 mtr coil. Make: Havells/Polycab/Grandlay/Any DJB approved make. |
| 5 | Supply of 4 Sq mm of FRLS PVC insulated copper conductor, single core cable, 180 mtr coil. Make: Havells/Polycab/Grandlay/Any DJB approved make. |
| 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm (DSR 2022 code 7.5.1) |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (D.S.R 2022 Code No -1.32) |
| 8 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 06-way, Double door (D.S.R 2022 Code No -2.3.1) |
| 9 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (D.S.R 2022 Code No -2.10.1) |
| 10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredSingle pole and neutral (D.S.R 2022 Code No -2.10.2) |
| 11 | Supply of ceiling fan having size 1200 mm (48') in white colour. Make: - Anchor/orient/Standard/ Any approved make by DJB. DJB SOR 2025 Item no. 20.1.2 |
| 12 | Supply of exhaust fan having size 300 mm, 1440 R.P.M. in grey colour of single phase 230 volts. Make: - Anchor/orient/ Standard/Almonard/Any DJB approved make. (DJB SOR 2025 Item no. 20.2.1) |
| 13 | Supply of Air Circulator having size 600 mm, 1440 R.P.M. in grey colour of single phase 230 volts. Make: - Anchor/orient/ Standard/Almonard/ Any DJB approved make. DJB SOR 2025 Item no. 20.2.2 |
| 14 | Supply of higher wattage decorative ultra slim aluminum LED lighting fixture with high lumen output environmental friendly, energy efficient ready to use pack 36 W LED Make: Havells /Philips/Crompton/ DJB approved make. DJB SOR 2022 Item no. 19.3.3 |
| 15 | Providing/ Fixing of 45W L.E.D Light energy saving & environmental friendly long-life Versatile pressure die-cast aluminum IP 66 roadway laminate with high power L.E. D as light source. Make-Havells/Bajaj/Crompton. DJB SOR 2022 Item no. 19.10.5 |
| 16 | New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. 70/72-watt LED (DJB SOR 2022 Code 19.10.6) |
| 17 | Supply and fixing if 32mm dia. 02 Mtr. long G.I pipe (medium class) bracket for mounting of fluorescent/ HPMV/HPSV street light fitting on pole/ wall including bending the pipe to the required shape, 2 Nos. 40mm X 3mm flat iron clamps with nuts, bolts, and washer, painting the flat iron with primer and finish paint etc. as required. (DSR-2022 code 12.34) |
| 18 | Supply of LT Power aluminum cable, solid conductor, XLPE insulated, PVC sheathed, armoured, 650/1100 V grade as per IS 7098 (Part 1) 1988 size 2 core 10 mm2 for external, internal lightening system and fans etc. 100 mtr Coil Make: - Polycab/ Gloster/ Havells. |
| 19 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required up to 35 sq. mm (clamped with 1mm thick saddle) (DSR 2022 code 7.7.1) |
| 20 | Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC Insulated, copper conductor, single core cable and earthing etc. as req. (DSR 2022 Item No. 1.41) Please Enable Macros to View BoQ information |