| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8138/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: REPAIRS TO AREA DRAINS, SEWAGE LINES, MANHOLES, COVER SLABS, HUME PIPE CULVERTS INCLUDING CLEANING OF CHOCKED SEWAGE LINES AND MANHOLES, COMPOUND WALL, HARDSTANDING ETC AND OTHER CONNECTED MAINTENANCE WORKS OF MISC NATURE AT CQA ( ICV) AREA UNDER GE GOLCONDA Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Demolition of cement concrete (Un-reinforced) in ground floors and pavings n exc. 15cm thick (Below or above ground level). |
| 3 | M&L for 100 mm thick PCC 1:2:4 type B-1, (using 20mm graded stone aggregate) for footpath / hard standing finishing surface of concrete even and rough without using extra cement complete all as specified and directed. |
| 4 | Demolition of brick work or stone/ boulder /PCC block masonry, built in cement mortar including all quoins, pillars etc. |
| 5 | M&L for square rubble masonry Secunderabad pattern , well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed. |
| 6 | M & L for PCC type D2 1:4:8 ( using 40mm graded stone aggregate) in foundations, filling and mass Concrete complete all as specified and directed. |
| 7 | M&L for flush pointing with CM 1:4 to random rubble masonry, uncoursed or brought upto course complete |
| 8 | M&L for brick work with sub class b bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 9 | M&L Rendering 15mm thick on brick work or concrete surface of walls in cement mortar 1 : 4 and finished even and smooth without using extra cement complete all as specified and directed. |
| 10 | M&L Rendering 15mm thick on fair faces of stone masonry surface of walls in cement mortar 1 : 4 and finished even and smooth without using extra cement complete all as specified and directed. |
| 11 | M&L for Preparing of newly plastered surfaces and applying three coats of white wash on walls complete and all as specified and directed. |
| 12 | M & L preparation of new surfaces of walls plastered or unplastered etc and applying two coat of cement based paint on wall surfaces as specified and directed. |
| 13 | M&L PCC 1:2:4, type Bo (using 20 mm graded stone aggregated) as in coping/ benching to manholes and drains including necessary form work complete all as specified and directed. |
| 14 | Demolition floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises. |
| 15 | M & L for 60mm thick machine pressed precast cement concrete tiles of interlocking pattern with grey cement and pigment rubber moulded with vibration technology set and jointed as per manufactures instructions laying over sand cushioning complete all as specified and as directed by Engr-in-charge. Note : (i) Rate quoted by contractor shall deemed to inclusive of filleting the side of pavement with PCC (1:2:4) type B1.(ii) Sand cushion should be measured & paid separately. |
| 16 | M & L for sand filling under floors including watering and consolidation complete all as specified. |
| 17 | M&L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base and finishing surface of concrete even and rough to receive the topping layer. |
| 18 | M&L chequered cement concrete tiles 300x300x25 mm thick with grey cement and pigment, machine pressed, set jointed and pointed in neat cement slurry in floors including 15 mm thick screed bed layer in CM 1:6 complete all as specified and directed. |
| 19 | Taking down cement plaster any description on brick or stone walls, roof plaster etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 20 | M & L preparation of old decorated surfaces of walls plastered or unplastered by brooming down or steel wire brushing, scrapping down smoke soots, moulds ,moss and efflorescent salts and treading oil and greasy spots etc and applying one coat of cement based paint complete all as specified. |
| 21 | Ditto as Item No.19 here in before but two coats of cement based paint. |
| 22 | Maintenance of sewage system SGSW/PVC/RCC pipe including Nahani / floor traps, Soil/waste pipe running on external wall of building and in trenches with fittings like bends, junctions, etc. gully traps, manholes of all description and sewage lines of all sizes upto soak well of sewage system including dewatering of soak wells complete in perfect running/flowing order without destruction by removing all blockage in the system including de-watering from soakage well by pumping out as directed as and when required including PCC/Brick drain in running condition by removing all surplus spoil in Md, OTM at Md/OTM Accommodation at CQA(ICV) Yeddumailaram, complete all as specified and directed.Notes for item No. 1:- (i) Contractor shall deploy minimum 1 safaiwala solely for the maintenance of sewage system against this item. This safaiwala shall not be deployed for any works other than the scope catered for in this item and will report to the respective complaint cell and will be issued daily complaint slips by the JE i/c. For the work catered against other items of this Schedule, the contractor shall deploy separate safaiwala in addition to the safaiwala deployed against this item. (ii) The shift time will be decided by JE/Engr-in-Charge and can be changed at any time as per requirement. However the timings for the day shift of 8 hours shall be from 0830 Hrs to 1730 Hrs with a lunch break from 1300 hrs to 1400 hrs with weekly holiday on sunday.(iii) The rate quoted is deemed to be inclusive of the cost of T&P for maint/cleaning work. (iv) Penal recovery for absence of workers/ technical supervisor on any day lesser than the specified minimum strength shall be as under:- (a) Safaiwala - Rs.2300.00 Per day per person(v) Solid waste / sludge / silt deposited in the manholes which can not be removed by rodding, shall be ordered under respective item of this schedule and paid accordingly. |
| 23 | Excavation in trenches n.exc 1.5m wide & n.exc 1.5m depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in hard and dense soil complete all as specified and directed. |
| 24 | All as per item No. 22 here-in-before but exc 1.5m and n.exc 3.00m in depth |
| 25 | Bailing out water from manholes manually or mechanically & taking out foreign material and removing same from MD lands including taking out manhole covers and replacing manhole covers in position on manholes of any size & depth complete all as directed. |
| 26 | Cleaning of septic tanks completely by emptying the liquid /semi solid foul contents, any depth mechanically as specified completely, cleaning the inlets /outlets etc including disposal of soil/sludge outside MD land complete all as specified and directed.Note:- The quantity actual measured at site shall be deducted 20% for bulkage of sludge. |
| 27 | Cleaning of drain pipes upto 150mm dia by rodding from manholes by mechanically or manually including well flushing with water and placing back manhole covers after cleaning complete all as specified and directed by Engineer-In-Charge. |
| 28 | Cleaning of drain pipes upto 300mm dia by rodding from manholes by mechanically or manually including well flushing with water and placing back manhole covers after cleaning complete all as specified and directed by Engineer-In-Charge. |
| 29 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 30 | M&L for Pre-cast Cement Concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in cover slabs for manholes etc., set in cement mortar (1:4) including mouldings complete all as specified and directed.Note: Reinforcement will be measured and paid separately. |
| 31 | M&L for Mild steel TMT bars, 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire complete all as specified and directed. |
| 32 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with all kind of soil complete all as specified and directed. |
| 33 | M&L for removing excavated surplus soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 34 | Supply and Fix Double walled corrugated pipes of outer dia 160mm and inner dia 136mm, SN-18 pipes confirming to IS 16205(Part 24- 2018)/ IS 14930 including all necessary packing, special fittings, cutting & jointing complete laid in trenches including taking down existing pipe complete all as specified and directed. |
| 35 | S & F PVC( SWR ) pipes 75mm dia single socketed , in any length with rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches including taking down complete all as specified and directed. |
| 36 | S & F PVC( SWR ) pipes 110mm dia single socketed , in any length with rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches including taking down complete all as specified and directed. |
| 37 | Dismantling fencing wire mesh of any type & description.. |
| 38 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed |
| 39 | Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out in hard/ dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 M and making good surface complete all as specified and directed. |
| 40 | M & L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation filling & mass concrete for post/pillars etc complete all as specified and directed. |
| 41 | S & F Mild steel work Angles, bars, flats etc. as in fencing post struts including cutting tops to shape as directed including embedding in concrete and all necessary drilling holes, bolting or riveting , welding notching for wire and similar work confirming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 42 | S & F mild steel screw bolts of 11 to 15mm diameter of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and not exc 10cm complete all as specified and as directed. |
| 43 | Supply only MS galvanised chain link fencing heavy zinc coated (Hot dip), aperture size 50mm and wire of 8 Swg (4 mm) complete all as specified and directed. |
| 44 | Fixing only chain link fencing any mesh size and type to any type of standard, rails, iron angle posts, straining bolts etc including provision of binding wire complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |