Tender For Cleaning/Maint Of Oht, Ug Sumps, Semi-Ug Sump, And Sedimentation Tanks At Various Location At Af Stn Singarsi Under Age (I) Af Stn Singarsi.
Tender Overview
Project Description
Tender for Cleaning/Maint Of Oht, Ug Sumps, Semi-Ug Sump, And Sedimentation Tanks At Various Location At Af Stn Singarsi Under Age (I) Af Stn Singarsi.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M&L for six stage cleaning and sterilization of inner surface of semi-UG Sump of capacity 1 Lakh Gallon installed at pump installations (Near 1 Lakh gallon pump house) through bacteriological & Ultraviolet ray treatment. Six stages are as under :-(a) First stage is Mechanised De-watering to drain out the remnant water using high capacity de-watering system, after the water has been drained off through valve.(b) Second stage is Sludge Removal, sucking out sludge settled on the floor of the tank using special sludge pumping equipment.(c) Third stage is High Pressure Cleaning, where the walls & ceilings of the tanks are thoroughly cleaned using special high pressure jet cleaners which rid of the walls off depositions, algae and all conrtaminants which cling onto the internal surface of the tank helping the microbiological contamination to grow.(d) Fourth stage is vacuum cleaning using industrial vacuum cleaner to remove the resultant contaminant, making the tank absolutely speck-free.(e) Fifth stage Anti-Bacterial Spray, make the walls & ceilings totally sterile from bacterial contamination using govt. certified anti-bacterial agents.(f) Sixth stage is UV Radiation treatment where final sterilization and disinfection is done using UV radiation by UV radiaotr which is used to kill any suspended or floating bacteria remaining in the tank.Note:-(i) Cleaning of external surfaces, lid wall of the tank, structure for all scales and other particles any algae, hives and any type of vegetaion or any other unwanted matters, scraping of old paint and painting with two coats of cement based water proof apex paint complete all as directed.(ii) A sticker of appropriate size and colour as directed by Engr in Charge and non degradeable material with printed details as under :-Date of Cleaning and Expiry date will be written.(iii) Painting of raising main, distribution, wash out and overflow pipes with suitable colour coding.(iv) All safety equipments required and necessary insurance for safey of working labour to execute the work is responsible of the contactor.(v) Clearing of premises around storage tank of vegetations/scrap/unwanted matters/debris shall be deemed to be included in the quoted price. |
| 2 | M&L for six stage cleaning and sterilization of inner surface of Over Head Tank of capacity 1 Lakh Gallon installed at pump installations (Near 1 Lakh gallon pump house) through bacteriological & Ultraviolet ray treatment. Six stages are as under :-(a) First stage is Mechanised De-watering to drain out the remnant water using high capacity de-watering system, after the water has been drained off through valve.(b) Second stage is Sludge Removal, sucking out sludge settled on the floor of the tank using special sludge pumping equipment.(c) Third stage is High Pressure Cleaning, where the walls & ceilings of the tanks are thoroughly cleaned using special high pressure jet cleaners which rid of the walls off depositions, algae and all conrtaminants which cling onto the internal surface of the tank helping the microbiological contamination to grow.(d) Fourth stage is vacuum cleaning using industrial vacuum cleaner to remove the resultant contaminant, making the tank absolutely speck-free.(e) Fifth stage Anti-Bacterial Spray, make the walls & ceilings totally sterile from bacterial contamination using govt. certified anti-bacterial agents.(f) Sixth stage is UV Radiation treatment where final sterilization and disinfection is done using UV radiation by UV radiaotr which is used to kill any suspended or floating bacteria remaining in the tank.Note:-(i) Cleaning of external surfaces, lid wall of the tank, structure for all scales and other particles any algae, hives and any type of vegetaion or any other unwanted matters, scraping of old paint and painting with two coats of cement based water proof apex paint complete all as directed.(ii) A sticker of appropriate size and colour as directed by Engr in Charge and non degradeable material with printed details as under :-Date of Cleaning and Expiry date will be written.(iii) Painting of raising main, distribution, wash out and overflow pipes with suitable colour coding.(iv) All safety equipments required and necessary insurance for safey of working labour to execute the work is responsible of the contactor.(v) Clearing of premises around storage tank of vegetations/scrap/unwanted matters/debris shall be deemed to be included in the quoted price. |
| 3 | M&L for six stage cleaning and sterilization of inner surface of Settling Tank (Sedmintation tank) of capacity 40000 Gallon (incl cogulation well & cascade aerators with baffle walls) installed at booster pump house through bacteriological & Ultraviolet ray treatment. Six stages are as under :-(a) First stage is Mechanised De-watering to drain out the remnant water using high capacity de-watering system, after the water has been drained off through valve.(b) Second stage is Sludge Removal, sucking out sludge settled on the floor of the tank using special sludge pumping equipment.(c) Third stage is High Pressure Cleaning, where the walls & ceilings of the tanks are thoroughly cleaned using special high pressure jet cleaners which rid of the walls off depositions, algae and all conrtaminants which cling onto the internal surface of the tank helping the microbiological contamination to grow.(d) Fourth stage is vacuum cleaning using industrial vacuum cleaner to remove the resultant contaminant, making the tank absolutely speck-free.(e) Fifth stage Anti-Bacterial Spray, make the walls & ceilings totally sterile from bacterial contamination using govt. certified anti-bacterial agents.(f) Sixth stage is UV Radiation treatment where final sterilization and disinfection is done using UV radiation by UV radiaotr which is used to kill any suspended or floating bacteria remaining in the tank.Note:-(i) Cleaning of external surfaces, lid wall of the tank, structure for all scales and other particles any algae, hives and any type of vegetaion or any other unwanted matters, scraping of old paint and painting with two coats of cement based water proof apex paint complete all as directed.(ii) A sticker of appropriate size and colour as directed by Engr in Charge and non degradeable material with printed details as under :-Date of Cleaning and Expiry date will be written.(iii) Painting of raising main, distribution, wash out and overflow pipes with suitable colour coding.(iv) All safety equipments required and necessary insurance for safey of working labour to execute the work is responsible of the contactor.(v) Clearing of premises around storage tank of vegetations/scrap/unwanted matters/debris shall be deemed to be included in the quoted price. |
| 4 | M&L for six stage cleaning and sterilization of inner surface of Storage Tank of capacity 20000 Gallon installed at booster pump house through bacteriological & Ultraviolet ray treatment. Six stages are as under :-(a) First stage is Mechanised De-watering to drain out the remnant water using high capacity de-watering system, after the water has been drained off through valve.(b) Second stage is Sludge Removal, sucking out sludge settled on the floor of the tank using special sludge pumping equipment.(c) Third stage is High Pressure Cleaning, where the walls & ceilings of the tanks are thoroughly cleaned using special high pressure jet cleaners which rid of the walls off depositions, algae and all conrtaminants which cling onto the internal surface of the tank helping the microbiological contamination to grow.(d) Fourth stage is vacuum cleaning using industrial vacuum cleaner to remove the resultant contaminant, making the tank absolutely speck-free.(e) Fifth stage Anti-Bacterial Spray, make the walls & ceilings totally sterile from bacterial contamination using govt. certified anti-bacterial agents.(f) Sixth stage is UV Radiation treatment where final sterilization and disinfection is done using UV radiation by UV radiaotr which is used to kill any suspended or floating bacteria remaining in the tank.Note:-(i) Cleaning of external surfaces, lid wall of the tank, structure for all scales and other particles any algae, hives and any type of vegetaion or any other unwanted matters, scraping of old paint and painting with two coats of cement based water proof apex paint complete all as directed.(ii) A sticker of appropriate size and colour as directed by Engr in Charge and non degradeable material with printed details as under :-Date of Cleaning and Expiry date will be written.(iii) Painting of raising main, distribution, wash out and overflow pipes with suitable colour coding.(iv) All safety equipments required and necessary insurance for safey of working labour to execute the work is responsible of the contactor.(v) Clearing of premises around storage tank of vegetations/scrap/unwanted matters/debris shall be deemed to be included in the quoted price. |
| 5 | M&L for six stage cleaning and sterilization of inner surface of Storage Tank of capacity 50000 Gallon capacity installed at various pump installations through bacteriological & Ultraviolet ray treatment. Six stages are as under :-(a) First stage is Mechanised De-watering to drain out the remnant water using high capacity de-watering system, after the water has been drained off through valve.(b) Second stage is Sludge Removal, sucking out sludge settled on the floor of the tank using special sludge pumping equipment.(c) Third stage is High Pressure Cleaning, where the walls & ceilings of the tanks are thoroughly cleaned using special high pressure jet cleaners which rid of the walls off depositions, algae and all conrtaminants which cling onto the internal surface of the tank helping the microbiological contamination to grow.(d) Fourth stage is vacuum cleaning using industrial vacuum cleaner to remove the resultant contaminant, making the tank absolutely speck-free.(e) Fifth stage Anti-Bacterial Spray, make the walls & ceilings totally sterile from bacterial contamination using govt. certified anti-bacterial agents.(f) Sixth stage is UV Radiation treatment where final sterilization and disinfection is done using UV radiation by UV radiaotr which is used to kill any suspended or floating bacteria remaining in the tank.Note:-(i) Cleaning of external surfaces, lid wall of the tank, structure for all scales and other particles any algae, hives and any type of vegetaion or any other unwanted matters, scraping of old paint and painting with two coats of cement based water proof apex paint complete all as directed.(ii) A sticker of appropriate size and colour as directed by Engr in Charge and non degradeable material with printed details as under :-Date of Cleaning and Expiry date will be written.(iii) Painting of raising main, distribution, wash out and overflow pipes with suitable colour coding.(iv) All safety equipments required and necessary insurance for safey of working labour to execute the work is responsible of the contactor.(v) Clearing of premises around storage tank of vegetations/scrap/unwanted matters/debris shall be deemed to be included in the quoted price. |
| 6 | M&L for six stage cleaning and sterilization of inner surface of Semi-UG/RCC overhead storage tank of capacity 10000 Gallon capacity installed at various pump installations at any height through bacteriological & Ultraviolet ray treatment. Six stages are as under :-(a) First stage is Mechanised De-watering to drain out the remnant water using high capacity de-watering system, after the water has been drained off through valve.(b) Second stage is Sludge Removal, sucking out sludge settled on the floor of the tank using special sludge pumping equipment.(c) Third stage is High Pressure Cleaning, where the walls & ceilings of the tanks are thoroughly cleaned using special high pressure jet cleaners which rid of the walls off depositions, algae and all conrtaminants which cling onto the internal surface of the tank helping the microbiological contamination to grow.(d) Fourth stage is vacuum cleaning using industrial vacuum cleaner to remove the resultant contaminant, making the tank absolutely speck-free.(e) Fifth stage Anti-Bacterial Spray, make the walls & ceilings totally sterile from bacterial contamination using govt. certified anti-bacterial agents.(f) Sixth stage is UV Radiation treatment where final sterilization and disinfection is done using UV radiation by UV radiaotr which is used to kill any suspended or floating bacteria remaining in the tank.Note:-(i) Cleaning of external surfaces, lid wall of the tank, structure for all scales and other particles any algae, hives and any type of vegetaion or any other unwanted matters, scraping of old paint and painting with two coats of cement based water proof apex paint complete all as directed.(ii) A sticker of appropriate size and colour as directed by Engr in Charge and non degradeable material with printed details as under :-Date of Cleaning and Expiry date will be written.(iii) Painting of raising main, distribution, wash out and overflow pipes with suitable colour coding.(iv) All safety equipments required and necessary insurance for safey of working labour to execute the work is responsible of the contactor.(v) Clearing of premises around storage tank of vegetations/scrap/unwanted matters/debris shall be deemed to be included in the quoted price. |
| 7 | M&L for six stage cleaning and sterilization of inner surface of UG sump of capacity 5000 Litres capacity installed at various pump installations at any height through bacteriological & Ultraviolet ray treatment. Six stages are as under :-(a) First stage is Mechanised De-watering to drain out the remnant water using high capacity de-watering system, after the water has been drained off through valve.(b) Second stage is Sludge Removal, sucking out sludge settled on the floor of the tank using special sludge pumping equipment.(c) Third stage is High Pressure Cleaning, where the walls & ceilings of the tanks are thoroughly cleaned using special high pressure jet cleaners which rid of the walls off depositions, algae and all conrtaminants which cling onto the internal surface of the tank helping the microbiological contamination to grow.(d) Fourth stage is vacuum cleaning using industrial vacuum cleaner to remove the resultant contaminant, making the tank absolutely speck-free.(e) Fifth stage Anti-Bacterial Spray, make the walls & ceilings totally sterile from bacterial contamination using govt. certified anti-bacterial agents.(f) Sixth stage is UV Radiation treatment where final sterilization and disinfection is done using UV radiation by UV radiaotr which is used to kill any suspended or floating bacteria remaining in the tank.Note:-(i) Cleaning of external surfaces, lid wall of the tank, structure for all scales and other particles any algae, hives and any type of vegetaion or any other unwanted matters, scraping of old paint and painting with two coats of cement based water proof apex paint complete all as directed.(ii) A sticker of appropriate size and colour as directed by Engr in Charge and non degradeable material with printed details as under :-Date of Cleaning and Expiry date will be written.(iii) Painting of raising main, distribution, wash out and overflow pipes with suitable colour coding.(iv) All safety equipments required and necessary insurance for safey of working labour to execute the work is responsible of the contactor.(v) Clearing of premises around storage tank of vegetations/scrap/unwanted matters/debris shall be deemed to be included in the quoted price. |
| 8 | Cleaning of jack well including taking out of sludge / desilting from jack well water and depositing upto 150 mtr to 200 mtr distance after blocking of Jackwell Intake and lifting from 12 to 15 meter depth from Jack well pump room flooring level including required dewatering complete including any type of materials required for the job all complete all as specified and as directed.Note: Any type of De-sludging pump/de-watering pump required is deemed to be included in the quoted price. |
| 9 | Collecting of water samples from (a) Gumani dam (b) booster pump house (c) Domestic area (01 Lakh Gallon) (d) Technical Area (04 No. P/H) of 5 Ltrs each from each location in container as recommended, transporting it to Govt recognised Lab for testing forwarding to the test house and carrying out chemical testing water for iron, PH value, hardness, turbidity, chloride, fluoride, arsenic, colour odour, TDS,E-coli test as per IS 10500:12 by Govt approved laboratory and submitting the report in triplicate complete all as specified and as directed . |
| 10 | M&L for cleaning of inner surface of various SWT of 10000 Gallon capacity installed at various location at AF Stn Singarsi.Stages of cleaning are as under :-(a) First stage is Mechanised De-watering to drain out the remnant water using high capacity de-watering system, after the water has been drained off through valve.(b) Second stage is Sludge Removal, sucking out sludge settled on the floor of the tank using special sludge pumping equipment.(c) Third stage is High Pressure Cleaning, where the walls & ceilings of the tanks are thoroughly cleaned using special high pressure jet cleaners which rid of the walls off depositions, algae and all conrtaminants which cling onto the internal surface of the tank helping the microbiological contamination to grow.(d) Fourth stage is vacuum cleaning using industrial vacuum cleaner to remove the resultant contaminant, making the tank absolutely speck-free.Note:-(i) Cleaning of external surfaces, lid wall of the tank, structure for all scales and other particles any algae, hives and any type of vegetation or any other unwanted matters, complete all as directed.(ii) A sticker of appropriate size and colour as directed by Engr in Charge and non degradeable material with printed details as under :-Date of Cleaning and Expiry date will be written.(iii) All safety equipments required and necessary insurance for safey of working labour to execute the work is responsible of the contactor.(iv) Clearing of premises around storage tank of vegetations/scrap/unwanted matters/debris shall be deemed to be included in the quoted price.(v) Repainting of marking plates of SWT with yellow colour with letter 'SWT' and the corresponding SWT number marked in black. |
| 11 | S & F in repair brass stainer for suction 100 mm Dia ISI Marked brass made complete all as specified and directed. |
| 12 | S & F in repair for cast iron sluice valve of 100 mm dia ISI Marked, confIrming to IS14846 both ends flanged with brass spindle, class PN1.6 and necessary new MS nuts, bolts, washer and gasket, including taking out old u/s ones for credit and making good etc complete all as specified and directed by Engr-in-Charge. |
| 13 | S & F in repair for cast iron sluice valve of 150 mm dia ISI Marked, confIrming to IS14846 both ends flanged with brass spindle, class PN1.6 and necessary new MS nuts, bolts, washer and gasket, including taking out old u/s ones for credit and making good etc complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L for joint with rubber or fibre board gasket (incl. bolts, nuts, washers and white lead or mineral oil) of size 150mm dia complete all as specified and as directed by Engr-in-Charge. |
| 15 | M&L for joint with rubber or fibre board gasket (incl. bolts, nuts, washers and white lead or mineral oil) of size 100mm dia complete all as specified and as directed by Engr-in-Charge. |
| 16 | M & L for applying two coat of synthetic enamel paint of existing colour shade on surfaces of any description, over 10 cm in width or girth, not otherwise described complete all as specified and as directed by Engr-in-Charge. |
| 17 | Demolition of concrete of any description and in any position not otherwise specifically provided for and disposal of debris/rubbish to a distance n.exc 100 m all as specified and as directed by Engr-in-Charge. |
| 18 | Demolition of brickwork or stone/boulder masonry, built in cement motor including quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles and disposal of debris/rubbish to a distance n.exc 100 m all as specified and as directed by Engr-in-Charge. |
| 19 | M&L for providing cement concrete type B0 1:2:4 (12.5 mm graded aggregate) in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands plinth courses, string courses lacing courses, parapets and railings upto 60 cm in height copings, kneelers, apex stones bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed.Note:-The rates include for use of form work (straight or curved). |
| 20 | Supply, Installation, Testing & Commissioning of outdoor type LT Panel 415 V, 3-ph, 50 Hz capacity, CPRI approved, of size not less than W (1m) x H(0.6m) x D(0.4m) made out of CRCA sheet 3.2 mm thick, verminproof, Floor Mounted, totally enclosed with front & rear opening, hinged doors alongwith suitable locking arrangements, weather and waterproof having required number of copper busbars of capacity 400 A for R,Y,B and Neutral with heat proof colour code and mounted on insulators, stickering of switchgears, danger notice plate, including connecting incoming and outgoing cables with necessary PCC 1:3:6 foundation on floor comprising the following:-Incoming(a) LED Indicating lamps - 03 Nos. Make: C&S/Neptune/L&T/Vaisnavo(b) Digital 3-Phase VIF Meter (VLN, VLL,I1, I2, I3 ,F), accuracy class-1, 4 digit -01 No.(c) MCCB 4P, 415 V, Adjustable type, 400A with breaking capacity 36 KA with provision to mount accessories (internal/sidewise) alongwith shunt trip release & spreader link-01 Set.(d) Voltage Monitoring relay with selectable UV (-2% to 20%) & OV (2% to 20%) monitoring & Single phase preventer alongwith LED indication for the same-01 No.(d) CT 300/5A, 5VA burden, CL 1.0-01 SetOutgoing (a) 04 Nos. threaded (04 on each strip) busbars of current carrying capacity 400A each with heatproof colour code for R, Y, B & N.-01 set(b) MCB TPN/FP,415V, breaking capacity 10 KA, class 'B'-01 No.(Note: Cost includes necessary control cable/power wiring connections,MCBs lugs/ other accessories necessary for LT Feeder Panel) |
| 21 | Supply, Installation, Testing & Commissioning of outdoor type LT Panel 415 V, 3-ph, 50 Hz capacity, CPRI approved, of size not less than W (0.5m) x H(0.45m) x D(0.35m) made out of CRCA sheet 3.15 mm thick outdoor pedestal type, verminproof, weatherproof, totally enclosed with front & rear opening, hinged doors alongwith suitable locking arrangements, weather and waterproof having 04 number of copper busbars each of capacity 100 A for R,Y,B and Neutral with heat proof colour code and mounted on insulators, stickering of switchgears, danger notice plate, including connecting incoming and outgoing cables with necessary PCC 1:3:6 foundation on floor comprising the following:-(a) LED Indicating lamps - 03 Nos. Make: C&S/Neptune/L&T/Vaisnavo(b) 04 Nos. threaded (03 on each strip) busbar of current carrying capacity 100A each with heatproof colour code for R, Y, B & N.-01 Set(Note: Cost also includes necessary control cables, mounting insulators/ other accessories necessary for LT Panel. ) |
| 22 | Supply, Installation, Testing & Commissioning of indoor type LT Changover Panel 415 V, 3-ph, 50 Hz capacity, CPRI approved, made out of CRCA sheet 2.0 mm thick, verminproof, Floor Mounted, totally enclosed with front & rear opening, hinged doors alongwith suitable locking arrangements, weather and waterproof having required number of copper busbars of capacity 160 A for R,Y,B and Neutral with heat proof colour code and mounted on insulators, stickering of switchgears, danger notice plate, including connecting incoming and outgoing cables with necessary PCC 1:3:6 foundation on floor comprising the following:-(a) On Load Changeover Switch (4-Pole) I-O-II -02 Nos. Make: Havells Euroload IHCNFO0100 or equivalent as specified(b) LED Indicating lamps - 03 Nos. Make: C&S/Neptune/L&T/Vaisnavo(c) Digital 3-Phase AC Voltmeter of size 96mmx96mm, input-100-500 V L-L, accuracy class-1, 4 digit-03 Nos.(Note: Cost includes necessary control/power wiring connections, MCBs, lugs/ other accessories necessary for LT Changeover Panel. Further, 06 sets (R,Y, B) of copper busbar are included in the quoted price) |
| 23 | Excavation in trenches in soft/loose/hard/dense soil/surface n.exc 1.5 mtr wide and n.exc 1.5 mtr deep & getting out soil for taking out/laying of cables/foundation, footing etc.complete all as specified & directed by Engr-in-Charge. Note: Make good excavated surfaces with PCC is deemed to be included in the quoted price. |
| 24 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25 cm.complete all as specified & directed by Engr-in-Charge. |
| 25 | Removing excavated mateials n.exc 50 mtr & depositing where directed at a level n.exc 1.5 mtr above the starting point.complete all as specified & directed by Engr-in-Charge. |
| 26 | Supply and laying new dry river sand laid in trenches 8 cm below the cable and 15 cm above the cable and punned to 18 cm as cable cushioning and cover complete all as specified and as directed. |
| 27 | Supply and laying of brick well burnt locally available sub class 'B' laid over sand cushioning for cable protection in trenches width of brick perpendicular to the length of cable, complete all as specified and directed by Engr-in-Charge. |
| 28 | M & L for galvanised light grade steel conduit of size 100 mm for laying cables in road crossings/drain crossings including necessary clamps/other accessories for laying the conduit along/across the drain, complete all as specified & directed by Engr-in-charge. |
| 29 | M & L for galvanised light grade steel conduit of size 150 mm for laying cables in road crossings/drain crossings including necessary clamps/other accessories for laying the conduit along/across the drain, complete all as specified & directed by Engr-in-charge. |
| 30 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sqmm, 3.5 core as per IS 7098 (pt-1) 1988 incl. accessories necessary for installation, complete all as specified and directed by Engr-in-Charge. |
| 31 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sqmm, 3.5 core as per IS 7098 (pt-1) 1988 incl. accessories necessary for installation, complete all as specified and directed by Engr-in-Charge. |
| 32 | S & F of Cable Support Brackets of MS flat of size not less than 50x5mm with horizontal and vertical section (total length not less than 0.5 m), vertical section to be fixed on wall of trench through necessary screw/nut-bolt arrangement and horizontal section for holding cable fastened through cleat/clamp incl necessary drilling, welding, cleat/clamp, etc complete all as specified and directed by Engr-in-Charge. |
| 33 | Supply and Fix double compression copper stainless steel gland for fixing armoured cable in panel of size 3.5 C x 400 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 34 | Supply and Fix double compression copper stainless steel gland for fixing armoured cable in panel of size 3.5 C x 240 to 300 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 35 | Supply and Fix double compression copper stainless steel gland for fixing armoured cable in panel of size 3.5 C x 95 to 120 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 36 | Supply and Fix double compression copper stainless steel gland for fixing armoured cable in panel of size 3.5 C x 50 to 70 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 37 | Supply and Fix double compression copper stainless steel gland for fixing armoured cable in panel of size 3.5 C x 150 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 38 | Supply and Fix copper cable lugs of size 400 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 39 | Supply and Fix copper cable lugs of size 3.5 C x 240 to 300 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 40 | Supply and Fix copper cable lugs of size 3.5 C x 95 to 120 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 41 | Supply and Fix copper cable lugs of size 3.5 C x 50 to 70 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 42 | Supply and Fix copper cable lugs of size 3.5 C x 150 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 43 | Supply of Engine Oil 20W40 complete all as specified and directed. |
| 44 | Supply of Engine Oil 15W40 (Make:Castrol CRB Turbo Max CH-4) complete all as specified and directed. |
| 45 | Supply of coolant (Make:KOEL CARE-K-COOL) complete all as specified and directed. |
| 46 | S & F of Danger Sign Board sticker, not less than 10 cm x 10 cm size for LT Panels with following indicated on it:-\\"440 Volts Danger\\" in Red and Yellow/White complete all as specified and as directed. |
| 47 | M & L for printing Layout Plan of size not less than 0.6 m x 0.6 m of Dam/Booster P/H or supply and distribution lines from Dam to Domestic area or technical area and entire technical area on paper and fixed to board with hook for wall hanging with lamination incl hanging on wall complete, all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender