Tender For Repair/Replacement Of Old Ci/Gi Main Pipeline And Connected Pipeline, Valve Pits And Connected Items In Zone I, Ii, Iii & Iv At Umroi Mil Stn Under Ge Umroi
Tender Overview
Project Description
Tender for Repair/Replacement Of Old Ci/Gi Main Pipeline And Connected Pipeline, Valve Pits And Connected Items In Zone I, Ii, Iii & Iv At Umroi Mil Stn Under Ge Umroi
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-Jul-2026 |
| 2 | 27-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 30-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of pole and laying of CI/GI/DI/PPR pipe and getting out in any type of soil complete all as specified and directed. |
| 2 | Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 3 | Returning, filling in, and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 4 | Taking up old unserviceable CI water mains (including all fittings) of size 200 mm bore with spigot and socket ends, tail pieces, sluice valves and lead joints etc. including burning out joints and recovering lead complete all as specified and directed. |
| 5 | Taking up old unserviceable CI water mains (including all fittings) of size150 mm bore with spigot and socket ends, tail pieces, sluice valves and lead joints etc. including burning out joints and recovering lead complete all as specified and directed. |
| 6 | Taking up old unserviceable CI water mains (including all fittings) of size 100 mm bore with spigot and socket ends, tail pieces, sluice valves and lead joints etc. including burning out joints and recovering lead complete all as specified and directed. |
| 7 | Taking up old unserviceable CI water mains (including all fittings) of size 80 mm bore with spigot and socket ends, tail pieces, sluice valves and lead joints etc. including burning out joints and recovering lead complete all as specified and directed. |
| 8 | Supplying, laying, jointing and testing ductile iron pipe, K-7 type with spigot and socket ends of size 200 mm dia laid in trenches including rubber gasket (tyton ring) jointing materials, etc. complete all as specified and directed. Note : DI fittings, excavation and PCC to be measured and paid separately. |
| 9 | Supplying, laying, jointing and testing ductile iron pipe, K-7 type with spigot and socket ends of size 150 mm dia laid in trenches including rubber gasket (tyton ring) jointing materials, etc. complete all as specified and directed. Note : DI fittings, excavation and PCC to be measured and paid separately. |
| 10 | Supplying, laying, jointing and testing ductile iron pipe, K-7 type with spigot and socket ends of size 100 mm dia laid in trenches including rubber gasket (tyton ring) jointing materials, etc. complete all as specified and directed. Note : DI fittings, excavation and PCC to be measured and paid separately. |
| 11 | Supplying, laying, jointing and testing ductile iron pipe, K-7 type with spigot and socket ends of size 80 mm dia laid in trenches including rubber gasket (tyton ring) jointing materials, etc. complete all as specified and directed. Note : DI fittings, excavation and PCC to be measured and paid separately. |
| 12 | Supply and fixing ductile iron fittings for socketed spigot, Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs any shape, of size up to 150mm bore complete all as specified and directed. Note: Run lead joints shall be measured and paid separately. |
| 13 | Supply and fixing ductile iron fittings for socketed spigot, Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs any shape, of size 200mm to 300mm bore complete all as specified and directed. Note: Run lead joints shall be measured and paid separately. |
| 14 | Supply and fix ductile iron sluice valve flange type of size 200 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gasket (neoprene) complete all as specified and directed. |
| 15 | Supply and fix ductile iron sluice valve flange type of size 150 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gasket (neoprene) complete all as specified and directed. |
| 16 | Supply and fix ductile iron sluice valve flange type of size 100 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gasket (neoprene) complete all as specified and directed. |
| 17 | Supply and fix ductile iron sluice valve flange type of size 80 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gasket (neoprene) complete all as specified and directed. |
| 18 | Supply and fix in repair ductile iron Non return valve flange type of 200 mm dia PN 1.6 grade (conforming to IS - 5312-2004) including complete fittings and fixing to pipe line with nuts, bolt and washers, rubber gasket (neoprene) complete all as specified and directed. |
| 19 | Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 400mm bore spigot and socket pipes complete all as specified and directed. |
| 20 | Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 250mm bore spigot and socket pipes complete all as specified and directed. |
| 21 | Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 200mm bore spigot and socket pipes complete all as specified and directed. |
| 22 | Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 150mm bore spigot and socket pipes complete all as specified and directed. |
| 23 | Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 100mm bore spigot and socket pipes complete all as specified and directed. |
| 24 | Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 80mm bore spigot and socket pipes complete all as specified and directed. |
| 25 | Cutting cast iron pipes of size 200/150mm bore and reducing to required length before laying in position for insertion of new tees, branches, etc for taking branches connection complete all as specified and directed. |
| 26 | Cutting cast iron pipes of size 100/80mm bore and reducing to required length before laying in position for insertion of new tees, branches, etc for taking branches connection complete all as specified and directed. |
| 27 | Drilling and tapping DI/cast iron water mains (in position) for branch connections of the internal dia 15mm complete all as specified and directed. |
| 28 | Drilling and tapping DI/cast iron water mains (in position) for branch connections of the internal dia 20mm complete all as specified and directed. |
| 29 | Material and labour for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 including preparation of surfaces and applying two coats of synthetic enamel paint over a coat of red oxide premier complete all as specified and directed. |
| 30 | Material and labour for structural steel, rolled section such as joist, beam, channel, angle, tee, in available lengths Fe 410-W (Gde-E-250) quality-A including preparation of surface and applying two coats of synthetic enamel paint over a coat of red oxide premier complete all as specified and directed. |
| 31 | Material and labour for mild steel bolts purpose made with hexagonal or square head one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long and diameter of neck 12 mm complete all as specified and directed. |
| 32 | Material and labour for welding in repairs exc 2.5 cm but not exc 5 cm in length, thickness of metal to be welded exc 6mm but not exc 9 mm complete all as specified and directed. Note: Cost of mild/structural steel shall be measured and paid separetly. |
| 33 | Taking up old unserviceable GI pipe and connections of sizes 80 mm bore including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 34 | Taking up old unserviceable GI pipe and connections of sizes 50 mm bore including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 35 | Taking up old unserviceable GI pipe and connections of sizes 40 mm bore including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 36 | Taking up old unserviceable GI pipe and connections of sizes 25 mm bore including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 37 | Taking up old unserviceable GI pipe and connections of sizes 20 mm bore including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 38 | Supply and fixing or laying 80mm bore galvanised Iron pipe, medium grade, and fixed complete to walls and ceilings or laid in trenches with all fittings such as tees, bend, elbows, sockets reducer, nipples and union complete all as specified and directed. |
| 39 | Supply and fixing or laying 50mm bore galvanised Iron pipe, medium grade, and fixed complete to walls and ceilings or laid in trenches with all fittings such as tees, bend, elbows, sockets reducer, nipples and union complete all as specified and directed. |
| 40 | Supply and fixing or laying 40mm bore galvanised Iron pipe, medium grade, and fixed complete to walls and ceilings or laid in trenches with all fittings such as tees, bend, elbows, sockets reducer, nipples and union complete all as specified and directed. |
| 41 | Supply and fixing or laying 25mm bore galvanised Iron pipe, medium grade, and fixed complete to walls and ceilings or laid in trenches with all fittings such as tees, bend, elbows, sockets reducer, nipples and union complete all as specified and directed. |
| 42 | Supply and fixing or laying 20mm bore galvanised Iron pipe, medium grade, and fixed complete to walls and ceilings or laid in trenches with all fittings such as tees, bend, elbows, sockets reducer, nipples and union complete all as specified and directed. |
| 43 | M&L for preparation old painted surfaces for CI/ MS pipe lines, distribution header and any other type of surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 44 | Supply and fixing or laying 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings having thermal stability for hot & cold water supply including all random fittings complete and fixed to walls and ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed. |
| 45 | Supply and fixing or laying 32mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings having thermal stability for hot & cold water supply including all random fittings complete and fixed to walls and ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed. |
| 46 | Supply and fixing or laying 20mm outer dia 3-layer PP-R Polyproplene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed. |
| 47 | Supply and fixing or laying 25mm outer dia 3-layer PP-R Polyproplene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed. |
| 48 | Supply and fixing or laying 32mm outer dia 3-layer PP-R Polyproplene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed. |
| 49 | Supply and fixing or laying 50mm outer dia 3-layer PP-R Polyproplene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed. |
| 50 | Supply and fixing or laying 63mm outer dia 3-layer PP-R Polyproplene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed. |
| 51 | Supply and fixing 63mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed. |
| 52 | Supply and fixing 50mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed. |
| 53 | Supply and fixing 32mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed. |
| 54 | Supply and fixing 25mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed. |
| 55 | Supply and fixing 20mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed. |
| 56 | Supply and fixing 50mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable gate valve complete all as specified and directed. |
| 57 | Supply and fixing 40mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable gate valve complete all as specified and directed. |
| 58 | Supply and fixing 25mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable gate valve complete all as specified and directed. |
| 59 | Supply and fixing 20mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable gate valve complete all as specified and directed. |
| 60 | M&L construction of brick masonry valve chamber of size 1200mm x 1200mm x 1200mm (Internal dimension) with PCC 1:3:6 foundation 150mm thick, brick work 23cm thick built in CM 1:6, PCC 1:3:6 coping 50 mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surfaces including excavation earth work in any type of soil, MS sheet cover 3mm thick fixed with angle iron frame 30x30x4 mm including hinges of size 125mm with locking arrangement embedded in PCC and painting of MS cover with two coats of synthetic enamel paint over a coat of red oxide primer, etc. complete all as specified and directed. |
| 61 | M&L construction of brick masonry valve chamber of size 600mm x 600mm x 750mm (Internal dimension) with PCC 1:3:6 foundation 150mm thick, brick work 23cm thick built in CM 1:6, PCC 1:3:6 coping 50 mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surfaces including excavation earth work in any type of soil, MS sheet cover 3mm thick fixed with angle iron frame 30x30x4 mm including hinges of size 125mm with locking arrangement embedded in PCC and painting of MS cover with two coats of synthetic enamel paint over a coat of red oxide primer, etc. complete all as specified and directed. |
| 62 | Demolition of cement concrete (un-reinforced) of any description in ground floor n exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 63 | Material and labour for 100 mm thick PCC 1:3:6 Type C-2 (using 40 mm graded stone aggregate) as in path finishing concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 64 | Material and labour for Cement concrete 1:3:6 Type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 65 | Supply, fixing and installation Automatic water Pressure Pump of capacity 1 HP suitable for hot water circulation, RO, Shower, Geyser vibration less, noiseless operation working complete all as specified and directed . |
| 66 | M& L for repairing of 250 mm water pipe line(CI/DI) by deploying adequate labour and replacing damaged water pipeline 6 m in length with DI pipe K7 of same dia including excavation as required for taking out the damaged pipe and fixing new pipe with necessary fittings as suited at site for fixing including returning filling and removing the excess soil from site complete all as specified and directed.Note: Old damaged pipe obtained shall be deposited to MES store yard. |
| 67 | M& L for repairing of 200 mm water pipe line(CI/DI) by deploying adequate labour and replacing damaged water pipeline 6 m in length with DI pipe K7 of same dia including excavation as required for taking out the damaged pipe and fixing new pipe with necessary fittings as suited at site for fixing including returning filling and removing the excess soil from site complete all as specified and directed.Note: Old damaged pipe obtained shall be deposited to MES store yard. |
| 68 | M& L for repairing of 150 mm water pipe line(CI/DI) by deploying adequate labour and replacing damaged water pipeline 6 m in length with DI pipe K7 of same dia including excavation as required for taking out the damaged pipe and fixing new pipe with necessary fittings as suited at site for fixing including returning filling and removing the excess soil from site complete all as specified and directed.Note: Old damaged pipe obtained shall be deposited to MES store yard. |
| 69 | M& L for repairing of 100 mm water pipe line(CI/DI) by deploying adequate labour and replacing damaged water pipeline 6 m in length with DI pipe K7 of same dia including excavation as required for taking out the damaged pipe and fixing new pipe with necessary fittings as suited at site for fixing including returning filling and removing the excess soil from site complete all as specified and directed.Note: Old damaged pipe obtained shall be deposited to MES store yard. |
| 70 | M& L for repairing of 80 mm water pipe line(CI/DI) by deploying adequate labour and replacing damaged water pipeline 6 m in length with DI pipe K7 of same dia including excavation as required for taking out the damaged pipe and fixing new pipe with necessary fittings as suited at site for fixing including returning filling and removing the excess soil from site complete all as specified and directed.Note: Old damaged pipe obtained shall be deposited to MES store yard. |
| 71 | Supply and fix 450mm bore reinforced concrete pipes, class NP3, laid and jointed complete with collars for water supply pipe line protection complete all as specified and directed. |
| 72 | Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender