Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #56002325

Tender For Repair/Replacement Of Old Ci/Gi Main Pipeline And Connected Pipeline, Valve Pits And Connected Items In Zone I, Ii, Iii & Iv At Umroi Mil Stn Under Ge Umroi

Issued by Statutory Bodies & Commissions/Committees · Umroi, Meghalaya
Tender Value
38 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
1 days left
EMD
76000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Umroi → Meghalaya
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Old Ci/Gi Main Pipeline And Connected Pipeline, Valve Pits And Connected Items In Zone I, Ii, Iii & Iv At Umroi Mil Stn Under Ge Umroi

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Jul-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-Jul-2026
2 27-Jul-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-Jul-2026

BOQ

Name of Work:- REPAIR/REPLACEMENT OF OLD CI/GI MAIN PIPELINE AND CONNECTED PIPELINE, VALVE PITS AND CONNECTED ITEMS IN ZONE I, II, III & IV AT UMROI MIL STN UNDER GE UMROI
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of pole and laying of CI/GI/DI/PPR pipe and getting out in any type of soil complete all as specified and directed.
2Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
3Returning, filling in, and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
4Taking up old unserviceable CI water mains (including all fittings) of size 200 mm bore with spigot and socket ends, tail pieces, sluice valves and lead joints etc. including burning out joints and recovering lead complete all as specified and directed.
5Taking up old unserviceable CI water mains (including all fittings) of size150 mm bore with spigot and socket ends, tail pieces, sluice valves and lead joints etc. including burning out joints and recovering lead complete all as specified and directed.
6Taking up old unserviceable CI water mains (including all fittings) of size 100 mm bore with spigot and socket ends, tail pieces, sluice valves and lead joints etc. including burning out joints and recovering lead complete all as specified and directed.
7Taking up old unserviceable CI water mains (including all fittings) of size 80 mm bore with spigot and socket ends, tail pieces, sluice valves and lead joints etc. including burning out joints and recovering lead complete all as specified and directed.
8Supplying, laying, jointing and testing ductile iron pipe, K-7 type with spigot and socket ends of size 200 mm dia laid in trenches including rubber gasket (tyton ring) jointing materials, etc. complete all as specified and directed. Note : DI fittings, excavation and PCC to be measured and paid separately.
9Supplying, laying, jointing and testing ductile iron pipe, K-7 type with spigot and socket ends of size 150 mm dia laid in trenches including rubber gasket (tyton ring) jointing materials, etc. complete all as specified and directed. Note : DI fittings, excavation and PCC to be measured and paid separately.
10Supplying, laying, jointing and testing ductile iron pipe, K-7 type with spigot and socket ends of size 100 mm dia laid in trenches including rubber gasket (tyton ring) jointing materials, etc. complete all as specified and directed. Note : DI fittings, excavation and PCC to be measured and paid separately.
11Supplying, laying, jointing and testing ductile iron pipe, K-7 type with spigot and socket ends of size 80 mm dia laid in trenches including rubber gasket (tyton ring) jointing materials, etc. complete all as specified and directed. Note : DI fittings, excavation and PCC to be measured and paid separately.
12Supply and fixing ductile iron fittings for socketed spigot, Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs any shape, of size up to 150mm bore complete all as specified and directed. Note: Run lead joints shall be measured and paid separately.
13Supply and fixing ductile iron fittings for socketed spigot, Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs any shape, of size 200mm to 300mm bore complete all as specified and directed. Note: Run lead joints shall be measured and paid separately.
14Supply and fix ductile iron sluice valve flange type of size 200 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gasket (neoprene) complete all as specified and directed.
15Supply and fix ductile iron sluice valve flange type of size 150 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gasket (neoprene) complete all as specified and directed.
16Supply and fix ductile iron sluice valve flange type of size 100 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gasket (neoprene) complete all as specified and directed.
17Supply and fix ductile iron sluice valve flange type of size 80 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gasket (neoprene) complete all as specified and directed.
18Supply and fix in repair ductile iron Non return valve flange type of 200 mm dia PN 1.6 grade (conforming to IS - 5312-2004) including complete fittings and fixing to pipe line with nuts, bolt and washers, rubber gasket (neoprene) complete all as specified and directed.
19Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 400mm bore spigot and socket pipes complete all as specified and directed.
20Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 250mm bore spigot and socket pipes complete all as specified and directed.
21Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 200mm bore spigot and socket pipes complete all as specified and directed.
22Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 150mm bore spigot and socket pipes complete all as specified and directed.
23Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 100mm bore spigot and socket pipes complete all as specified and directed.
24Material and labour for run lead joints for CI/DI pipe (water main) and fittings of size 80mm bore spigot and socket pipes complete all as specified and directed.
25Cutting cast iron pipes of size 200/150mm bore and reducing to required length before laying in position for insertion of new tees, branches, etc for taking branches connection complete all as specified and directed.
26Cutting cast iron pipes of size 100/80mm bore and reducing to required length before laying in position for insertion of new tees, branches, etc for taking branches connection complete all as specified and directed.
27Drilling and tapping DI/cast iron water mains (in position) for branch connections of the internal dia 15mm complete all as specified and directed.
28Drilling and tapping DI/cast iron water mains (in position) for branch connections of the internal dia 20mm complete all as specified and directed.
29Material and labour for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 including preparation of surfaces and applying two coats of synthetic enamel paint over a coat of red oxide premier complete all as specified and directed.
30Material and labour for structural steel, rolled section such as joist, beam, channel, angle, tee, in available lengths Fe 410-W (Gde-E-250) quality-A including preparation of surface and applying two coats of synthetic enamel paint over a coat of red oxide premier complete all as specified and directed.
31Material and labour for mild steel bolts purpose made with hexagonal or square head one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long and diameter of neck 12 mm complete all as specified and directed.
32Material and labour for welding in repairs exc 2.5 cm but not exc 5 cm in length, thickness of metal to be welded exc 6mm but not exc 9 mm complete all as specified and directed. Note: Cost of mild/structural steel shall be measured and paid separetly.
33Taking up old unserviceable GI pipe and connections of sizes 80 mm bore including cleaning for re-fixing or removal to store complete all as specified and directed.
34Taking up old unserviceable GI pipe and connections of sizes 50 mm bore including cleaning for re-fixing or removal to store complete all as specified and directed.
35Taking up old unserviceable GI pipe and connections of sizes 40 mm bore including cleaning for re-fixing or removal to store complete all as specified and directed.
36Taking up old unserviceable GI pipe and connections of sizes 25 mm bore including cleaning for re-fixing or removal to store complete all as specified and directed.
37Taking up old unserviceable GI pipe and connections of sizes 20 mm bore including cleaning for re-fixing or removal to store complete all as specified and directed.
38Supply and fixing or laying 80mm bore galvanised Iron pipe, medium grade, and fixed complete to walls and ceilings or laid in trenches with all fittings such as tees, bend, elbows, sockets reducer, nipples and union complete all as specified and directed.
39Supply and fixing or laying 50mm bore galvanised Iron pipe, medium grade, and fixed complete to walls and ceilings or laid in trenches with all fittings such as tees, bend, elbows, sockets reducer, nipples and union complete all as specified and directed.
40Supply and fixing or laying 40mm bore galvanised Iron pipe, medium grade, and fixed complete to walls and ceilings or laid in trenches with all fittings such as tees, bend, elbows, sockets reducer, nipples and union complete all as specified and directed.
41Supply and fixing or laying 25mm bore galvanised Iron pipe, medium grade, and fixed complete to walls and ceilings or laid in trenches with all fittings such as tees, bend, elbows, sockets reducer, nipples and union complete all as specified and directed.
42Supply and fixing or laying 20mm bore galvanised Iron pipe, medium grade, and fixed complete to walls and ceilings or laid in trenches with all fittings such as tees, bend, elbows, sockets reducer, nipples and union complete all as specified and directed.
43M&L for preparation old painted surfaces for CI/ MS pipe lines, distribution header and any other type of surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
44Supply and fixing or laying 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings having thermal stability for hot & cold water supply including all random fittings complete and fixed to walls and ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed.
45Supply and fixing or laying 32mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings having thermal stability for hot & cold water supply including all random fittings complete and fixed to walls and ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed.
46Supply and fixing or laying 20mm outer dia 3-layer PP-R Polyproplene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed.
47Supply and fixing or laying 25mm outer dia 3-layer PP-R Polyproplene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed.
48Supply and fixing or laying 32mm outer dia 3-layer PP-R Polyproplene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed.
49Supply and fixing or laying 50mm outer dia 3-layer PP-R Polyproplene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed.
50Supply and fixing or laying 63mm outer dia 3-layer PP-R Polyproplene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc. complete all as specified and directed.
51Supply and fixing 63mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
52Supply and fixing 50mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
53Supply and fixing 32mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
54Supply and fixing 25mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
55Supply and fixing 20mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
56Supply and fixing 50mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable gate valve complete all as specified and directed.
57Supply and fixing 40mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable gate valve complete all as specified and directed.
58Supply and fixing 25mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable gate valve complete all as specified and directed.
59Supply and fixing 20mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable gate valve complete all as specified and directed.
60M&L construction of brick masonry valve chamber of size 1200mm x 1200mm x 1200mm (Internal dimension) with PCC 1:3:6 foundation 150mm thick, brick work 23cm thick built in CM 1:6, PCC 1:3:6 coping 50 mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surfaces including excavation earth work in any type of soil, MS sheet cover 3mm thick fixed with angle iron frame 30x30x4 mm including hinges of size 125mm with locking arrangement embedded in PCC and painting of MS cover with two coats of synthetic enamel paint over a coat of red oxide primer, etc. complete all as specified and directed.
61M&L construction of brick masonry valve chamber of size 600mm x 600mm x 750mm (Internal dimension) with PCC 1:3:6 foundation 150mm thick, brick work 23cm thick built in CM 1:6, PCC 1:3:6 coping 50 mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surfaces including excavation earth work in any type of soil, MS sheet cover 3mm thick fixed with angle iron frame 30x30x4 mm including hinges of size 125mm with locking arrangement embedded in PCC and painting of MS cover with two coats of synthetic enamel paint over a coat of red oxide primer, etc. complete all as specified and directed.
62Demolition of cement concrete (un-reinforced) of any description in ground floor n exc 15cm thickness (below or above ground level) complete all as specified and directed.
63Material and labour for 100 mm thick PCC 1:3:6 Type C-2 (using 40 mm graded stone aggregate) as in path finishing concrete surface even and smooth without using extra cement complete all as specified and directed.
64Material and labour for Cement concrete 1:3:6 Type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
65Supply, fixing and installation Automatic water Pressure Pump of capacity 1 HP suitable for hot water circulation, RO, Shower, Geyser vibration less, noiseless operation working complete all as specified and directed .
66M& L for repairing of 250 mm water pipe line(CI/DI) by deploying adequate labour and replacing damaged water pipeline 6 m in length with DI pipe K7 of same dia including excavation as required for taking out the damaged pipe and fixing new pipe with necessary fittings as suited at site for fixing including returning filling and removing the excess soil from site complete all as specified and directed.Note: Old damaged pipe obtained shall be deposited to MES store yard.
67M& L for repairing of 200 mm water pipe line(CI/DI) by deploying adequate labour and replacing damaged water pipeline 6 m in length with DI pipe K7 of same dia including excavation as required for taking out the damaged pipe and fixing new pipe with necessary fittings as suited at site for fixing including returning filling and removing the excess soil from site complete all as specified and directed.Note: Old damaged pipe obtained shall be deposited to MES store yard.
68M& L for repairing of 150 mm water pipe line(CI/DI) by deploying adequate labour and replacing damaged water pipeline 6 m in length with DI pipe K7 of same dia including excavation as required for taking out the damaged pipe and fixing new pipe with necessary fittings as suited at site for fixing including returning filling and removing the excess soil from site complete all as specified and directed.Note: Old damaged pipe obtained shall be deposited to MES store yard.
69M& L for repairing of 100 mm water pipe line(CI/DI) by deploying adequate labour and replacing damaged water pipeline 6 m in length with DI pipe K7 of same dia including excavation as required for taking out the damaged pipe and fixing new pipe with necessary fittings as suited at site for fixing including returning filling and removing the excess soil from site complete all as specified and directed.Note: Old damaged pipe obtained shall be deposited to MES store yard.
70M& L for repairing of 80 mm water pipe line(CI/DI) by deploying adequate labour and replacing damaged water pipeline 6 m in length with DI pipe K7 of same dia including excavation as required for taking out the damaged pipe and fixing new pipe with necessary fittings as suited at site for fixing including returning filling and removing the excess soil from site complete all as specified and directed.Note: Old damaged pipe obtained shall be deposited to MES store yard.
71Supply and fix 450mm bore reinforced concrete pipes, class NP3, laid and jointed complete with collars for water supply pipe line protection complete all as specified and directed.
72Schedule of Credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56002325
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38 Lakhs
LAST DATE 30-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Old Ci/Gi Main Pipeline And Connected Pipeline, Valve Pits And Connected Items In Zone I, Ii, Iii & Iv At Umroi Mil Stn Under Ge Umroi
Basic Detail
Tender No 8985/E8
Bidding Type Tender
Location
City Umroi
State Meghalaya
Key Dates
Publish Date 27 Jul 2026
Submission Date 30 Jul 2026
Open Date 01 Aug 2026
Finance
Tender Value 38 Lakhs
Tender Fee 500
EMD 76000
Exemption Available
Document List
17fed1ad-19f0-4dc9-9a61-0f807acefe05.html
8985TENDERDOCUMENTS.pdf
BOQ_864933.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 30, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

17fed1ad-19f0-4dc9-9a61-0f807acefe05.html

pdf

8985TENDERDOCUMENTS.pdf

xls

BOQ_864933.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail