| 1 | Taking of liquid/solid content from sump/septic tank/drain either manually or by pumping clearing thoroughly including disposal of liquid/solid content out of the airforce area ,depositing in pit and covering with layers of earth and taking all precautions against foul/hazzardous gas etc, complete all as specified and directed . |
| 2 | Cleaning of sewage/Drain line of any size and section below ground level by mechanical or manual operation all as specified and directed. |
| 3 | M&L for cleaning the sewage septic tanks of 50 users any size and depth by de-watering and getting out the sludge/decompose scum (MALVA) and foreign material by adequate capacity mechanical motar pump of close containar of municipal corporation /owened vehical and Burring the Malva/foriegn material out side the defence land in the trenches in incl excavation in any type of soil & refilling with & incl spreading of bleaching powder @ 2kg /sqm of surface area of dump complete all as specified & as directed.by EIC. |
| 4 | All as per Srl item No.03 above but 25 Users. |
| 5 | All as per Srl item No.03 above but 10 Users. |
| 6 | Cleaning of manholes upto 0.9m depth by de-watering and getting out the sludge and foreign materials and removing the same out side the defense land all as directed (Rate also included plugging to manhole & removing the plug after cleaning). |
| 7 | Cleaning of manholes depth above 0.9m and upto 1.5m depth by de-watering and getting out the sludge and foreign materials and removing the same out side the defense land all as directed (Rate also included plugging to manhole & removing the plug after cleaning). |
| 8 | M&L for cleaning the sewage soakage wells of 2.40m dia and 3.00m depth and by de-watering by adequate capacity mechanical motar pump of close containar of municipal corporation owned vehical and Burring the material out side the defence land in the trenches in incl excavation in any type of soil & refilling with & incl spreading of bleaching powder @2kg /sqm of surface area of dump complete all as specified & as directed.by EIC. |
| 9 | All as per item No 08 here-in-before but 1.80m dia and 3.00 m depth. |
| 10 | All as per item No 08 here-in-before but 1.20m dia and 3.00 m depth. |
| 11 | Cleaning of gully trap of any size and depth by dewatering and getting out foreign material sludge etc. and removing out side exc. 50 M apart including CI/SWG pipe of any dia from gulley trap to 1st man hole of bldg complete all as directed. |
| 12 | Cutting into existing manholes for connecting new drain making good to pipes and rendering, cutting out existing benching for forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 finished smooth good to pipe complete to match with the existing works for 150mm dia pipe all as specified and directed |
| 13 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth in soft/loose soil etc complete all as specified and directed |
| 14 | Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed |
| 15 | Removal of excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed |
| 16 | Demolition/Dismantling and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 150 mm internal dia of pipe complete all as specified and directed. |
| 17 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling,sub base and mass concrete complete all as specified and directed. |
| 18 | M&L salt Glazed stone ware drain pipe 150 mm bore grade 'A' laid in trenches and jointed and testing complete all as specified & directed. |
| 19 | M&L for laying DWCP 150 mm Minimum internal dia pipes in trenches Class SN-8 conforming to IS 16098 (Part -2) in 6 mtr length with coupler complete all as specified and directed by Engr-in-charge |
| 20 | M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and directed. |
| 21 | M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 22 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 23 | M&L Brick work using old size bricks with sub class 'B' bricks in one brick thick honey comb walling built in cement mortar 1:4 complete all as specified and directed. |
| 24 | M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) all as specified |
| 25 | All as per Srl item No 24 above but except brick |
| 26 | M&L Broken bricks of gauge not exceeding 63 mm for loose filling in sokage pit, sokage wells complete all as specified and directed. |
| 27 | Supply only integral water proofing compound all as specified and directed. |
| 28 | M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:4 with water proofing compound @2% of weight of cement and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 29 | M & L applying three coat of white wash on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified. |
| 30 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and directed. |
| 31 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 32 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed. |
| 33 | M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) ,slab and similar work including necessary form work and set in CM 1:6 complete all as specified and directed. |
| 34 | Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete. |
| 35 | Mild Steel TMT bar 6 to 8mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete. |
| 36 | S&F framed work such as grills, gratings etc with ends of bars shouldered and or reiverted or forged into spikes, framed guard bars and similar work conferming to Fe 410-0 or Fe 310-0 |
| 37 | M&L two coat of synthetic enamel pinting over a coat of red oxide primer incl preparation of steel new surface over 10 cm width or girth etc complete all as specified and directed. |
| 38 | Taking down of eves gutter,rain water pipes of any size or pattern including all fittings etc complete all as specified and directed. |
| 39 | S&F, PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and directed. |
| 40 | S&F, PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and directed. |
| 41 | S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed. |
| 42 | S & F PVC (SWR) bends any radius, 75 mm bore complete all as specified and directed. |
| 43 | PVC (SWR) 110mm bore 'T' equal or unequal complete all as specified and directed. |
| 44 | S & F in Cast iron soil (Sand Cast Pipes) 100mm waste and vent pipes in any length with or without ears, with cement joints, laid in wall complete all as specified and directed. |
| 45 | S & F in Cast iron soil (Sand Cast Pipes) 75mm waste and vent pipes in any length with or without ears, with cement joints, laid in wall complete all as specified and directed. |
| 46 | S & F Bends (any radius) with duck's foot or heel rest 100mm complete all as specified and directed. |
| 47 | S & F Bends (any radius) with duck's foot or heel rest 100mm complete all as specified and directed. |
| 48 | S & F Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches 100mm bore with oval access door all as specified and directed by Engr-in-charge. |
| 49 | S&F in repair vitreous china squatting pan white orissa pattern size 580 x 440mm with integral foot rests (excludig flushing cistern & flush pipe) with cast iron trap and make good to match with the existing surface of floor all as specified and directed by Engr-in-charge. |
| 50 | S&F in repair vitreous china wash down water closet pan including seat cover (pedestal pattern) white excluding flushing cistern & flush pipe including connection to out going pipe and flushing pipe complete all as specified and directed by Engr-in-charge. |
| 51 | S&F in repair 10 Ltr capacity PVC valveless shyphonic action type low level flushing cistern white with inlet, ball valve, float valve and handle incl bracket and flush pipe of low level of 32mm dia fixed to wall complete. |
| 52 | M&L for Removal of Land Sliding Material/Snow/Debris by removing the same by JCB to a distance exc 50 mtr and making the surface good complete all as directed. Note :- Per Hour Charge will be started when JCB will reached actual site only working hours will be measured and paid. |
| 53 | Water proofing treatment to sunken floor of RCC slab as following steps- (a) Applying first coat of chemical pidifin 2K (DR Fixit or equivalent) on cleaned plastered surfaces @ 0.86 kg/sqm (min) as recommended by manufacturers. Then Provide a layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) over first coat of chemical pidifin 2K as manufactures recommendations. After Apply second coat of chemical pidifin 2K (DR Fixit or equivalent) @ 0.86 kg/sqm (min) layer glass fibre mesh as recommended by manufacturers. |
| 54 | (b) Spouts of 50mm dia PVC pipes projecting at least by 150mm clear of face of the outer wall. |
| 55 | (c) 30 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate mixed with WPC @ 3% by weight of cement shall be provided on bottom. |
| 56 | (d) The sunken portion shall be filled with PCC 1:7:12 type F2 using 40mm brick aggregate after carrying out required test for joints/water proofing.Note 1:- The treatment shall also be provided over side wall upto a ht of 150 mm above FFLNote 2:- Water proofing treatment will be carried out through authorised applicators approved by GE and testing charge included in item rate. |
| 57 | Clearing away roots, and trees not exceeding 30 cm girth on buildings at any height including all grass vegetation, saplings, shrubs, brushwood, undergrowth, and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance except in the case of surface dressing which includes for all the foregoing except clearing away of trees complete all as specified and as directed. |
| 58 | Dismantling floor, hearth or wall tiling in-cluding cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 59 | M&L for Non Skid ceramic tiles 7 to 8 mm thick ( square / rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match (in patches to match the existing colour /shed) over and including screed bed 15mm thick rendering in CM 1:6 all as directed. |
| 60 | M&L for glazed ceramic tiles colour 350x250x7mm / 450x350x7mm thick in vertical surfaces such as skirting, dado and risers to steps set and jointed in neat cement slurry and pointed in coloured cement to match over 10mm thick cement mortar 1:4 on fair faces of brick work or concrete surfaces as backing for tiles complete all as specified. |
| 61 | S & F in Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified and directed by Engr-in-charge. |
| 62 | S&F in repair 100 mm/ 125mm dia mild steel chromium plated grating fixed on floor trap / nahani trap in Cement mortar 1:6 , all as specified and directed by Engr-in-charge. |
| 63 | S&F PVC (SWR) floor trap with grating 75 mm dia incl jointing with solvent cement all as specified and directed by Engr-in-charge Please Enable Macros to View BoQ information |