| 1 | Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in Hard/dense/any type soil for laying of GI pipe complete all as specified and directed. |
| 2 | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed. |
| 3 | Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point. |
| 4 | Taking up cast iron water mains 150mm bore (inc all fittings) with spigot and socket ends and lead joint including burning out joints and accessories from bakloh cantt area upto bharai area complete all as specified and directed by Engineer-in-Charge |
| 5 | Taking up or down GI Tubing and connections of 150mm dia complete with socket/flanged joint and accessories form bakloh cantt area upto bharai area incl cleanning for re-fixing/ re-laying or remove from site all as specified and directed by Engineer-in-charge. |
| 6 | All as per Item No 5 above but 100 mm dia |
| 7 | All as per Item No 5 above but 80 mm dia |
| 8 | All as per Item No 5 above but 50 mm dia |
| 9 | All as per Item No 5 above but 40 mm dia |
| 10 | All as per Item No 5 above but 25 mm dia |
| 11 | All as per Item No 5 above but 20mm dia |
| 12 | Re-fixing/ re-laying old GI/CI tubing and connections of 150 mm dia with fittings in new/old position incl. bend, elbow, reducer, union, flange, nipple etc complete all as specified and directed by Engineer-in-charge Note: Rate shall deemed to be include repair/renewal of all running existing connection/ branches from main water supply line, incl T&P used) |
| 13 | All as per Item No 12 above but 100 mm dia |
| 14 | All as per Item No 12 above but 80 mm dia |
| 15 | All as per Item No 12 above but 50 mm dia |
| 16 | All as per Item No 12 above but 40 mm dia |
| 17 | All as per Item No 12 above but 25 mm dia |
| 18 | All as per Item No 12 above but 20mm dia |
| 19 | Supply and laying in trench/fixed on wall/floors galvanized steel water tubing medium grade ISI marked incl all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc. of 150mm bore, by re-routing /original position of pipeline complete from Bakloh cantt area upto Kuddan nallah area all as specified and directed by Engineer-in-Charge. Note :- Necessary excavation and earth work shall be measured and paid separately |
| 20 | All as per Item No 19 above but 100 mm dia |
| 21 | All as per Item No 19 above but 80 mm dia |
| 22 | All as per Item No 19 above but 50 mm dia |
| 23 | All as per Item No 19 above but 40 mm dia |
| 24 | All as per Item No 19 above but 25 mm dia |
| 25 | All as per Item No 19 above but 20mm dia |
| 26 | S&F gunmetal globe or gate valve with iron wheel head screwed bolt ends for iron pipe of the sizes 20 mm dia complete incl taking down old gate valves all as specified and directed by Engineer-in-charge. |
| 27 | All as per Item No 26 above but 25 mm dia |
| 28 | All as per Item No 26 above but 40 mm dia |
| 29 | All as per Item No 26 above but 50 mm dia |
| 30 | Supply and fixing in replacement cast iron sluice valve of dia 150 mm dia flanged of class PN 1.6 with iron wheel installed complete with nut bolts, washers of suitable size and pair of rubber gasket of superior quality including taking down unsv sluice vlave all as specified and directed by Engineer-in-charge. Note: Rate shall deemed to be include cutting/disconnecting water supply line, inserting flange/nipple/union/socket as required at site and making good distrubed surface, incl T&P used. |
| 31 | All as per Item No 30 above but 80 mm dia |
| 32 | All as per Item No 30 above but 65 mm dia |
| 33 | M & L for taking out the existing sluice valve of the following sizes and taking out the worn-out gate and spindle, refixing back the gate and new spindle made out of stainless steel rod of suitable size to fix the existing gate inc check nut regrinding of the gate fixing of nuts & bolts, gaskets etc complete all as specified :- |
| 34 | (a) 150mm bore |
| 35 | (b) 80mm bore |
| 36 | Supply and fixing Ball brass valves high pressure with polythene flote and flynut complete secewed for iron pipe or brass feerrule 20mm dia including taking down u/S valve complete all as specified and directed by Engineer-in-Charge. |
| 37 | M&L for Cutting the existing CI/GI pipe 40/50/65/80/100/150 mm bore or screwing existing CI/GI pipe for addn or altn as required on site including GI fiitings complete all as directed. Note: Necessary earth work shall be measured and paid separately. |
| 38 | M&L for Cast iron bends of Bore upto 150 mm bore (any type,radius and angles) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces, single branch, 'Y' junction double branch, cross, Tail piece (all socket, spigot) collars, caps plughs complete all as specified and directed. |
| 39 | M&L construction of brick masonary valve pit built in cement mortar 1:6 including all excavation and earth work in any type of soil and disposal of surpluse soil to a distance not exc. 50 mtr all as directed by Engineer-in-charge including 10mm thick plastering internally in CM 1:4 and flush pointing in same mortar to brick work externally as work proceeds and cement concrete in foundation PCC (1:4:8) type D-2 15 cm thick & PCC 1:3:6 type C-1 coping, including 75 mm thick & hard core of gauge and exc. 63mm using broken stone /bolder, MS sheet cover 3.15 mm thick MS angle iron frame, handle locking arrangement and painting to steel surfaces including dismantling of old valve pit complete all as specified and directed by Engineer-in-Charge. incl necessary excavation earth work of the following sizes :- |
| 40 | (a) 900 mm x 900mm x 900mm. |
| 41 | (b) 1200mmx1200mmx1200mm |
| 42 | Supply only chlorine chemical test kit in replacement of old u/s kit for testing of water complete all as specified and directed by Engineer-in-Charge.Make: Declibac Tech. Pvt Ltd. or equivalent. |
| 43 | M & L for excavation including returning filling in and all earth work for repair the leakage of CI line lead joint including burning out the old lead joints and repairing including filling the lead as required at site and testing of water main after repairing of 150mm bore complete all as specified and directed. Note : Lead will be measured and paid separately in the relevant Item of BOQ. |
| 44 | Supply only leather buffalo superior quality not less than 3.00mm thick all as specified and directed by Engr-in-Charge. |
| 45 | Supply only GI Flange heavy duty suitable for 150mm bore of pipe complete all as specified and directed. |
| 46 | Supply only carbon steel nut/bols/washers of any size as per sample complete all as specified and directed. |
| 47 | M & L for arragnement and fixing of tripot stand and taking up submersible motor upto 7.5HP including dismantling of 40/50mm dia MS ERW flanged column pipe joints with nut/bolts/washers upto 130 mtr length from borewell and keeping aside in safe custody and lowering the same after repairing/rewinding the motor and pump including repalcment of rubber gasket and nut/bolts/washers as required at site complete all as specified and directed. |
| 48 | M & L transportation of submersible pump to the nearest workshop including dismantling, cleaning and taking out old inserviceable parts impellor/distance/ connecting pieces/base plate bearing etc and repalcment with as per existing parts as required and testing complete after repair all as specified and directed by Engr-in-Charge. |
| 49 | M & L for dismantling and taking out old burnt winding of submersible motor upto 7.5 HP and rewinding after cleaning of all slots with super enamelled copper conductor wire with F Class insulation complete including replacement of sand guard and both end bearing as required and testing complete all as specified and directed by Engr-in-Charge. |
| 50 | M&L for taking out old unserviceable submersible motor starter and S&F single phase pre wired submersible starter comprising relay/timer including MPCB with sheet metal enclosure suitable upto 7.5 HP motor complete all as specified and directed. |
| 51 | M & L for dismantling centrifugal pump set of 5 HP and transportation to workshop for servicing, greasing and reapir/replacement of both end bearing, coupling key and fixing gland packing including taking out old burnt winding of motor and rewinding with super enamelled copper conductor as per exisiting gauge after cleaning of all slots and testing at site after making all electric connections complete all as specified and directed. |
| 52 | M&L for replacement in repair single phase DOL motor starter suitable for 5HP comprsing relay/contractor/capacitor with sheet metal enclosure including all electirc connections all as specified |
| 53 | Supply only white lead as per sample complete all as specified and directed. |
| 54 | M&L for demolition of existing unserviceable throust block/pillar/retaining wall of any kind and PCC (1:2:4) type B2 using 40mm graded aggregate in walls or retaining wall, any thickness, size or shapr including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 55 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions of rough finished concrete complete all as specified and directed. |
| 56 | M&L for servicing of water purification system with replacement of choked filter, memberan, pvc pipe, UV protection memberan with complete cleaning and proper testing of water after complete replacement of all unserviceable items inside the water pruification system for capacity of 8 Ltr to 14 Ltr for make of Kent/ Aquaguard or equivalent other make all as specified and directed by Engineer-in-Charge |
| 57 | M&L for servicing of water Dispenser system with replacement of water guard, up middle plate, switch plate, hot thermostat, drier filter, hot taps, drain box with fillign of refregent ges R-134a with complete testing of Cold and Hot water system and proper testing of all electrical wiring after complete replacement of all unserviceable items inside the Water Dispenser system for capacity of 20 Ltr for make of VOLTAS or equivalent other make all as specified and directed by Engineer-in-Charge |
| 58 | M&L for general servicing/ repair and maintenance of split type AC's of capacity 1.5 TR comprising of the following tasks at different location of any condition & and transporting to contractor workshop to carry out necessary repair including refixing at site, commissioning, testing, painting of AC's and writing of MES Number complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (ii) Carry out running test of operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting for leakage in the system. (iv) Checking the earth continuity of electrical parts. (v) Checking the functioning of thermostat. (vi) Inspection of electrical parts. (vii) Testing the machine for satisfactory operation. Note:- (i) Any part found unserviceable / defective shall be measured and paid separately under respective item here-in-after. (ii) Make of parts shall be as per original window type AC. Please Enable Macros to View BoQ information |