| 1 | Surface excavation n.exc (not exceeding) 30cm deep and averaging 15 deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavation over areas n exc 1.5 m in depth for foundation and getting out.in soft/loose soil complete all as specified and directed. |
| 3 | All as per item No 2.00 above but beyond 1.5m depth and upto 3m depth complete all as specified and directed. |
| 4 | M&L cement concrete in foundations, filling and mass concrete type C2, (1:4:8) using 40mm graded stone aggregate complete all as specified and directed. |
| 5 | M&L for PCC 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete etc.complete all as specified and directed. |
| 6 | M&L RCC M-30 (using 20 mm graded stone aggregate) as in footing, foundation of raft complete all as specified and directed. |
| 7 | M&L RCC M-30 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors and roof etc and the like complete all as specified and directed. |
| 8 | M&L RCC M-30 (using 20 mm graded stone aggregate) as in wall, retaining wall, ballast wall, basement wall etc and the like any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. |
| 9 | Material & labour pre-cast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates as in pre-cast cover slabs/GT cover slab of any thickness, size or shape including all necessary form work , finishing concrete surface fair & even and set in CM 1:4 complete all as specified and directed. |
| 10 | M&L TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9 mm diameter complete all as specified and directed. |
| 11 | M&L TMT bars 6.00 mm to 8.00 mm dia , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9 mm diameter complete all as specified and directed. |
| 12 | M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; verticle or to batter finish even and fair finish complete all as specified and directed. |
| 13 | M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better finish even and fair finish complete all as specified and directed. |
| 14 | M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick finish even and fair finish complete all as specified and directed. |
| 15 | M & L for Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide finish even and fair finish complete all as specified and directed. |
| 16 | Returning, filling in, including spreading, levelling, watering and well remming in layers n exc 25 cm, in soil complete all as specified and directed. |
| 17 | Removing excavated soil, exc 50 m but n exc 100 m and deposited where directed at a level n exc 1.50 m above the starting point complete all as specified and directed. |
| 18 | M&L for hard core (with broken stone/boulders) gravel of gauge 40 to 60 mm, deposited, spread and levelled in layers n exc 15 cm thick to a true surfaces complete all as specified and directed. |
| 19 | M&L for filling with broken stone/boulders gravel of gauge 3 to 10 mm, deposited, spread and levelled in layers n exc 15 cm thick to a true surfaces complete all as specified and directed. |
| 20 | M&L for filling with broken stone/boulders pea gravel of gauge n.exc 3.6 mm, deposited, spread and levelled in layers n exc 15 cm thick to a true surfaces complete all as specified and directed. |
| 21 | M&L for sand filling with graded course sand under floors spreading and levelling in layers n exc 25cm thick as required complete all as specified and directed. |
| 22 | M&L Rendering 15 mm thick on brick/ concrete surfaces in CM (1:4) using water proofing compound mixing with cement as per manufacturer instruction and finish the surface even and smooth without using extra cement complete all as specified and directed. |
| 23 | Supply only Integral water proofing compound ISI marked complete all as specified and directed. |
| 24 | S&F 20 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors including taking down old steel tubing, connections with fittings complete all as specified and directed. |
| 25 | S&F 150mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches including necessary fixing etc complete all as specified and directed. |
| 26 | S&F 100mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches including necessary fixing etc complete all as specified and directed. |
| 27 | S&F PVC/ HDPE (SWR) Bends 150mm bore, without oval access doors complete all as specified and directed. |
| 28 | S&F PVC/ HDPE (SWR) Bends 100mm bore, without oval access doors complete all as specified and directed |
| 29 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters;cover slab frame,plates walk ways;drainage crossings , railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 30 | M&L preparing new steel surfaces over 10 cm in width or girth of any description and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 31 | M & L for 400mm dia Boring hole (recharge bore well) drilling including fixing of 250mm dia nominal bore UPVC plain & strainer pipe lowering in rain water harvesting pit up to 130 mtr deep in any type of strata with all accessories, ,mud picking, gravel, gravel packingwashing, air compressor cleaning finishing and other labour charges etc complete all as specified and directed. Please Enable Macros to View BoQ information |