| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep, in any type of soil including forming sides and bottom surfaces to required level / slope / gradients etc for taking down/laying of the pipe lines complete all as specified and directed at site.Note: The disturbed surfaces of roads/paths/plinth etc shall be made good by the contractor to match with the existing surfaces without any extra cost). |
| 2 | Returning, filling in, excavated soil in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 3 | Removing of excavated surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | Disconnecting and taking down old existing steel tubing and connections of any description/ grade and in any position in trenches/under floors / on walls etc including all fittings/accessories and fixtures such as bends, union, elbow socket etc, all as directed and specified for the following sizes :- |
| 5 | 80 mm bore |
| 6 | 50 mm bore |
| 7 | 40 mm bore |
| 8 | 25 mm bore |
| 9 | 20 mm bore |
| 10 | 15 mm boreNote applicable for item no 04:- Excavation & earth work shall be measured and paid separately under respective item of Sch 'A'. |
| 11 | Supply, laying, jointing and testing galvanized iron water tubing, medium grade, including all necessary GI fittings /accessories laid in trenches complete all as specified and directed for the following sizes |
| 12 | 80mm bore |
| 13 | 50 mm bore |
| 14 | 40 mm bore |
| 15 | 25 mm bore |
| 16 | 20 mm bore |
| 17 | 15 mm bore |
| 18 | Disconnecting and taking down old existing cast iron/DI pipe line/ water main and connections of any description/ grade including lead if any and in any position in trenches/under floors / etc including all fittings/accessories and fixtures such as bends, union,elbow socket etc, all as directed and specified for the following sizes :- |
| 19 | 150 mm bore |
| 20 | 100 mm bore |
| 21 | Supplying ,laying, jointing & testing in trenches ductile iron pipes with spigot and socketed ends centrifugally cast (spun cast) class K-9 suitable for Titen joints complete all as specified and directed for the following size:- |
| 22 | 150 mm bore |
| 23 | 100 mm bore NOTE applicable for item no 07:- Earth work, and CI specials/ fittings of the pipes shall be measured and paid for separately under respective item of Schedule `A'. |
| 24 | Suplly and fixing Titen joint suitable for K-9 Ductile iron pipe complete all as specified and directed by Engineer-in-Charge for the following size:- |
| 25 | (a)150 mm bore |
| 26 | (b)100 mm bore |
| 27 | M & L for ISI Marked, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe complete all as specified and directed for following bore of pipes:- |
| 28 | 50mm bore |
| 29 | 40mm bore |
| 30 | 25mm bore |
| 31 | 20mm bore |
| 32 | 15mm bore |
| 33 | M & L for 15mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed . |
| 34 | Dismantling of leaked flanged joints and M&L for rubber gasket joints in flanged end cast iron pipes and fittings complete with and including minimum 3 mm thick rubber/fibre gasket and necessary mild steel nuts, bolts & washers all as specified and directed for following sizes:- |
| 35 | 150 mm bore |
| 36 | 100 mm bore |
| 37 | 80 mm bore |
| 38 | M&L for cutting of existing CI/GI pipe line in position for insertion of collars or other fittings including dewatering etc complete all as specified and directed for the following bore of pipes:- |
| 39 | 150 mm bore |
| 40 | 100 mm bore |
| 41 | 80 mm bore. Note applicable for item no 12 S&F of insertion of fittings etc shall be measured & paid for separately under appropriate item of Sch 'A'). |
| 42 | M& L for new run lead joint by new lead pig and making new joint by spun yarn and caulking etc all as specified and directed for the following sizes :- |
| 43 | 150 mm bore |
| 44 | 100mm bore |
| 45 | 80 mm bore |
| 46 | M& L for repairing of leaked lead joint by taking out lead and making lead joint by retrieved lead and extra lead required including spun yarn and caucking etc all as specified and directed for the following sizes :-Note (i) leakage shall be made functional within a 48 Hrs otherwise a penalty @ Rs 1000/- per day shall be recovered from the payment due |
| 47 | 150 mm bore |
| 48 | 100 mm bore |
| 49 | 80mm bore |
| 50 | M& L for repairing of leaked /broken GI pipe including necessary cutting threading and Re fixing with new GI Fitting, excavation and earth work, bailing out water etc complete all as specified and directed for the following sizes :Note; (i) The replacement of defective / nonfunctional parts of GI fittings shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’/BOQ(ii)Excavation shall be measured & paid for separately under appropriate item of Sch 'A'/BOQ and (iii)Necessary thread and white lead shall be deemed to be included in this item.(iv)leakage shall be made functional within a 48 Hrs otherwise a penalty @ Rs 1000/- per day shall be recovered from the payment due . |
| 51 | GI PIPE 80mm bore |
| 52 | GI pipe 50 mm dia |
| 53 | GI pipe 40 mm dia |
| 54 | GI pipe25 mm dia |
| 55 | GI pipe20 mm dia |
| 56 | GI pipe15 mm dia |
| 57 | Supply only GI union 50 mm medium grade |
| 58 | Supply only GI union 40 mm medium grade |
| 59 | Supply only GI union 25 mm medium grade |
| 60 | Supply only GI union 20 mm medium grade |
| 61 | Supply onlyGI union 15 mm medium grade |
| 62 | Supply only nipple 80 mm medium grade |
| 63 | Supply only nipple 50 mm medium grade |
| 64 | Supply only nipple 40 mm medium grade |
| 65 | Supply only nipple 25 mm medium grade |
| 66 | Supply only nipple 20 mm medium grade |
| 67 | Supply only nipple 15 mm medium grade |
| 68 | Supply only GI Socket 80 mm medium grade |
| 69 | Supply only GI Socket 50 mm medium grade |
| 70 | Supply only GI Socket 40 mm medium grade |
| 71 | Supply only GI Socket 25 mm medium grade |
| 72 | Supply only GI Socket 20 mm medium grade |
| 73 | Supply onlyGI Socket 15 mm medium grade |
| 74 | Supply only GI Tee 50 mm medium grade |
| 75 | Supply only GI Tee 40 mm medium grade |
| 76 | Supply only GI Tee 25 mm medium grade |
| 77 | Supply only GI Tee 20 mm medium grade |
| 78 | Supply only GI Tee 15mm medium grade |
| 79 | Supply only GI elbo 50mm medium grade |
| 80 | Supply only GI elbo 40mm medium grade |
| 81 | Supply only GI elbo 25mm medium grade |
| 82 | Supply only GI elbo 20mm medium grade |
| 83 | Supply only GI elbo 15mm medium grade |
| 84 | Supply only CI \\" D\\" Joint 80 mm medium grade |
| 85 | Taking up or down existing cast iron sluice valves of any description and in any position, removing from site including taking out joints complete all as specified and directed for the following sizes :- (NOTE : Sluice valves other than those dismantled with taking up or down of cast iron pipe lines shall be measured and paid for under this item) |
| 86 | 150 mm bore |
| 87 | 100 mm bore |
| 88 | 80 mm bore |
| 89 | Supply, installation, fixing, jointing and testing, ISI Marked, cast iron sluice valve of class PN-1.6 conforming to IS-14846 of 2000 both ends flanged with iron wheel head and stainless steel spindle, jointed with and including jointing material such as rubber or fibre gasket, nuts, bolts washers etc and tested complete all as specified and directed for following bores :- |
| 90 | 150 mm bore |
| 91 | 100 mm bore |
| 92 | 80 mm bore |
| 93 | Taking up or down exiting cast iron non return valves of any description and in any position, removing to stores including taking out joints complete all as specified and directed for the following sizes: |
| 94 | 100 mm bore |
| 95 | 80 mm Bore |
| 96 | Supply and fixing, 100mm bore, ISI Marked, cast iron non return valve, both ends flanged jointed and tested complete all as specified and directed. |
| 97 | Supply and fixing, 80mm bore, ISI Marked, cast iron non return valve, both ends flanged jointed and tested complete all as specified and directed. |
| 98 | Supply & fixing in Replacement of PVC float valve complete all as specified and directed for the following sizes: |
| 99 | 40 mm bore |
| 100 | 25mm bore |
| 101 | 20 mm bore |
| 102 | 15 mm bore |
| 103 | Supplying, fixing, jointing and testing cast iron/ductile iron specials/fittings such as bend, tee, socket, color, Reducer, Tail Pieces etc. suitable for spigot and socketed/ flanged end pipes of 150 mm bore and below complete all as specified and directed. |
| 104 | M&L for fabricating and fixing of pipe line MS clamp of flat iron made to shape alongwith nuts, bolt washers etc suitable for following pipe line all as specified and directed for stopping leaking of pipe lines of any description and in any position. Clamps shall be made to shape and size as approved, tightened with suitable nuts, bolts washers as directed. |
| 105 | 150mm bore |
| 106 | 100 mm bore |
| 107 | 80 mm bore. |
| 108 | 50 mm bore |
| 109 | 40 mm bore. Note: S&F of insertion of fittings etc shall be measured & paid for separately under appropriate item of Sch 'A'). |
| 110 | Cutting of Road/floor by electric hammer/manual for dismantling/laying of pipe line, complete all as specified and directed |
| 111 | M & L for cement plastering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finish even and fair complete all as specified and directed. |
| 112 | M & L for cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 113 | Supply and fixing for 15mm Stop valves PTMT any colour screwed down, high pressure screwed both ends for iron pipe complete all as specified and directed. |
| 114 | Supply and fixing for 20mm Stop valves PTMT any colour screwed down, high pressure screwed both ends for iron pipe complete all as specified and directed. |
| 115 | Supply & fixing in replacement MS flange With stud 100 mm complete all as specified and directed. |
| 116 | Supply & fixing in replacement MS flunge With stud 80 mm complete all as specified and directed. |
| 117 | Disconnecting the existing non functional submersible pump set from supply net work. dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacity and in any position, alongwith existing column pipe 80/50mm dia and existing submersible cable of any size from the bore well (approximately 50 mtr depth of pump set from GL) complete and lowering after repair with all accessories including testing all as specified and directed.NOTE: 1. Contractor shall take proper precautions while lifting out and removing motor/pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. Any items like cable, column pipe, clamps etc shall be measured andpaid separately under respective item as Supply only. 2 . Any repair to submersible pump & spares etc shall be paid and measured separately under relevant item in this schedule as Supply only |
| 118 | Dismantling and strip opening of submersible pump/motor of any description of Capacity up to 20 HP for repairing /overhauling, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts (To be paid separately) including minor parts such as washer, 'O' Rings, nut bolts and any machining work required re-threading of holes, lock nut etc required for smooth functioning of pump motor and reassembling the pump and motor, ensuring proper alignment of pump and motor, complete all as directed. Note: - (i) The replacement of defective / unserviceable parts shall be measured and paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under these item. (ii) Burnt out windings of motor shall be replaced, measured and paid separately under appropriate item of Sch ‘A’ for rewinding as M&L. |
| 119 | Supply only the following items / parts of submersible motor/pump of above mentioned types and capacity complete all as specified and directed:- |
| 120 | Upper & lower rubber housing bush |
| 121 | Stainless steel rotor sleeve. |
| 122 | Thrust bearing complete set. |
| 123 | MS Flange with stud. |
| 124 | Motor base of cast iron. |
| 125 | Neck Ring . |
| 126 | Pump Key |
| 127 | Sim wisher |
| 128 | Segment holder assembly. |
| 129 | Strainer. |
| 130 | Oil seal. |
| 131 | Coupling set with key of stainless steel |
| 132 | Discharge outlet of cast iron for pump |
| 133 | Rotor For15to20 HP Submersible motor. |
| 134 | Stage casing of Cast Iron |
| 135 | Gun metal body bush. |
| 136 | Impeller |
| 137 | Rotor machining, grinding and balancing |
| 138 | Motor tube boring, machining & reconditioning |
| 139 | motor lamination setting with material |
| 140 | Rotor reconditioning |
| 141 | slote repairing in stator |
| 142 | Stainless steel distance bush ( Spacer). |
| 143 | Inlet bracket |
| 144 | Cable Guard |
| 145 | Stainless Steel Connection Piece (Adopter Piece) |
| 146 | Cast iron Suction Housing including studs |
| 147 | Rotor up to 12.5 HP Submersible motor. |
| 148 | SS Pump shaft suitable up to 12.5 HP complete all as specified and directed. |
| 149 | SS Pump shaft suitable for 15 to 20 HP complete all as specified and directed. |
| 150 | Supply only water proof joint of submersible cable 3 core of any size using fine rubber and M Seal etc complete all as specified and directed. |
| 151 | Supply only flat copper conductor submersible cable of size 6 Sqmm, 3 core complete including necessary achoring accessies along the column pipe etc all as specified and directed. |
| 152 | Supply only flat copper conductor submersible cable of size 4 Sqmm, 3 core complete including necessary achoring accessies along the column pipe etc all as specified and directed. |
| 153 | Supply only flat copper conductor submersible cable of size 2.5 Sqmm, 3 core complete including necessary achoring accessies along the column pipe etc all as specified and directed. |
| 154 | Supply only GI socket, heavy duty, seamless, long threaded ISI marked for 80mm bore column pipes all as directed by Engineer-in-Charge. |
| 155 | Supply only GI socket, heavy duty, seamless, long threaded ISI marked for 50mm bore column pipes all as directed by Engineer-in-Charge. |
| 156 | Supply only Galvanised iron medium grade 3.00 mtr long 80 mm bore column pipe both ended threaded and long socket complete all as directed. |
| 157 | Supply only Galvanised iron medium grade 3.00 mtr long 50 mm bore column pipe both ended threaded and long socket complete all as directed. |
| 158 | Taking out and removing old burnt out windings of the submersible electric motors 15 to 20 HP, 3 Phase, 415 Volts of following capacity and re winding of submersible electric motors with existing size super enamel insulated, copper winding wire including cleaning the slots with carbon- tetra-chloride solution before re winding including repairing of stator including grinding, re-conditioning required lamination insulation material etc complete all as specified and directed. |
| 159 | All as per item no.42 above but submersible electric motor of 10 /12.5 HP |
| 160 | All as per item no. 42 above but submersible electric motor of 5 /7.5 HP |
| 161 | Repair to stage casing outer & inner diffuser of submersible pump of any description by cutting, balancing, brazing , welding, turning and Grinding complete all as specified and directed for the following capacities of the pumps coupled with submersible motors of capacity 15 to 20 HP |
| 162 | All as per item no. 45 above but submersible pump capacity upto 5.0 to 12.5 HP |
| 163 | Cutting out the unserviceable / damaged portion of the 80mm bore GI column pipe of any grade, making new threads to suitable lengths (for providing long threaded socket) for jointing the pipes with old/new pipes to replace the unserviceable length or to increase the length of column pipe specified etc complete all as directed. Please Enable Macros to View BoQ information |
| 164 | Cutting out the unserviceable / damaged portion of the 80mm bore GI column pipe of any grade, making new threads to suitable lengths (for providing long threaded socket) for jointing the pipes with old/new pipes to replace the unserviceable length or to increase the length of column pipe specified etc complete all as directed. Please Enable Macros to View BoQ information |