| 1 | Dewatering of static watering tank, underground/semi underground tank by using machenical pump 7.5 HP for necessary cleaning and repairing works complete all as specified and directed. |
| 2 | M&L for repairing of damaged RCC Chajja, fascia, fins, roof projection, ceiling and balcony railing etc at any height by rendering 15 to 25mm thick in one or two layers as per site requirement in CM 1:3 incl hacking out old broken/damaged concrete portion, cleaning of old reinforcement etc and applying neat cemtnt slurry @ 3 Kg/Sqm complete all as specified and directed. (Note : Rate for all scaffolding required for repairing work shall be deemed included in this rate) |
| 3 | M & L for crack cutting & removing the concrete in side the crack line properly & maintain the groove size(50mmx25mm) of the bldg at any height and then all crack properly filling with micro concrete Renderoc RG (FOSROC) and all as specified and directed. |
| 4 | M & L Injecting Conbextra EP10 (FOSROC) through the prefixed nozzles under pressure using grout pump to fill all possible pores and gaps left within the concrete mass of the bldgs of any height and when the flow of grout stops, or when the grout flows out of the adjacent nozzle, pumping is stopped and the nozzle is tied up and allowed to set for 24 hours. The PVC nozzles shall be sealed off with a quick-setting waterproofing agent like Renderoc Plug. Grouting operation is carried out through the next nozzle till the entire area is covered.The grouting holes shall be finished by removing the nozzles and finishing flush with the surface. |
| 5 | Supply only liquid water proofing chemical complete all as specified and directed. |
| 6 | S&F 1.40mm dia GI netting (20mm mesh size) over/around exposed reinforcement of SWT walls, wall cracks etc and securing with screws, washers/ nails complete all as specified and directed by Eng-in-Charge. |
| 7 | M&L for Cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in kerbs or coping, mud stops, floor, hard standing etc rounded or chamfered on edges, slightly rounded chamfered angles and throating incl necessary form work complete all as specified and directed by Eng-in-Charge. |
| 8 | M&L for 75 mm thick plain cement concrete (1:3:6) type C1, using 20 mm graded stone aggregate as in Plinth protection and finishing the surface even & smooth without using extra cement complete all as specified and directed. |
| 9 | Complete removal of existing treatment on wall surface (any number of layers) and applying three coats of white wash including prepration complete all as specified and directed. |
| 10 | S&F in repairs 25mm bore Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 11 | S&F in repairs 40mm bore Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 12 | Dismantling wrought iron or mild steel work of any description at ant place not otherwise complete all as specified and directed. |
| 13 | Dismantling posts or struts (Wood, RCC) any section, including taking out embeded portion and making good distrubed ground, including any type fencing all as specified and directed. |
| 14 | Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cu. m, and getting out, and removing excavated n exc 50m depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 15 | M & L for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 16 | M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; fencing post, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 17 | M&L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.. |
| 18 | Fixing only in repairs of 4mm dia chain link fencing, of mesh (50mmx50mm) size, of any type to angle iron with MS Flat Iron, and fencing will be strengthened by fixing MS flat/round bars horizontally complete all as specified and directed.Note: (i) S&F of FI, Angle, round bar & bolts shall be measured and paid separately. (ii) Supply only of chain link fencing shall be measured and paid separately. |
| 19 | Supply only 4mm dia galvanised steel chain link fencing of mesh size 50mmx50mm with both ends of the fabric without knocking and twisting any size complete all as specified and directed. |
| 20 | S&F of mild steel screw bolts (machine made) 10 to 15mm dia of neck and length exc 5cm but n'exc 10cm, with hexagonal or square heads at one end and screwed ends fixed with two washers and one nuts complete all as specified and directed. |
| 21 | S&F in repair welded steel wire fabric mesh, exc 4kg/sqm cut to length , bent to shape required and fixing complete to steel member etc complete all as specified and directed. |
| 22 | Demolition of unreinforced cement concrete /pavement quality concrete in ground floors and pavings below or above ground level by means of machanical methed including cutting by machine of existing edges/ boundary of any thikness and removing the demolished material exc.1.5 km but not exc. 5 km from site /out of defence land complete all as specified and directed. |
| 23 | M&L for pavement quality control concrete using crushed stone aggregate having minimum field flexural sength of 40 Kg/Sq Cm and characteristic compressive strength 40 N/Sqmm in pavement using non circular/triangular synthetic fibre @ 0.25% by weight of cement used laid to level, gradient and camber including necessary form work and laying of polythene under and side of concrete complete all as specified and directed. Note : Non circular / trinagular fibre shall be measured and paid for seperately as supply only. |
| 24 | Supply only polyster non-circular /triangular fibres 12mm long with circum circle diameter 30-35 micron, designed for melting point of 240-260 degree celcius and having specific gravity of 1.34 to 1.40 complete all as specified and directed. |
| 25 | Forming 20mm thick Expansion joints full depth of slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed. |
| 26 | M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound complete all as specified and directed. |
| 27 | Demolition of stone slabs and paver tiles of any description or thickness in floors, aprons etc laid in any type of mortor complete all as specified and directed. |
| 28 | M&L for 60mm thick factory made cement concrete paver block with approved colour, design & pattern as in footparth, parks, lawns, drive ways or parking etc, over and including 50mm thick compacted bed of fine sand/stone dust compacting, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 29 | M&L 75mm thick cement concrete 1:4:8 Type D2 ( using 40mm graded stone aggregates) as in sub base complete all as specified and directed. |
| 30 | M&L for factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed. |
| 31 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete including demolition of brick work of any description and in any position built in cement mortar including all quoins, arches pillar etc including disposal of rubbish complete all as specified and directed.all as specified and directed. |
| 32 | All as pe item No 31 herein before above but except bricks.Note : Old serviceable bricks retreived from item no 31 shall be reused. |
| 33 | M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth (without using exrtra cement) complete all as specified and directed. |
| 34 | M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth (without using exrtra cement) including taking down cement plaster on brick surface or stone surfaces and raking out joints hacking for key, scrubbing down with water etc in at different locations complete all as specified and directed. |
| 35 | M&L for Preparation of newly plaster surface of wall and applying two coat of exterior emultion weather proof paint over a coat of primer white or tinted as approved all as specified and directed. |
| 36 | M&L for prepration of old painted steel/ iron surfaces by removing loose paint with sand paper/steel scrapers of any description exc 10cm in width or girth and applying two coat of synthetic enamel paint in camouflaging pattern on CCD scheme (Pattern as approved by User) over a coat of primer complete including necessary scafolding complete all as specified and directed. |
| 37 | M&L for Preparing old decorated plastered or unplastered surfaces of external walls and applying one coat of weather coat exterior emulsion paint including filling cracks/depressions with putty/POP to make the adjacent surface even and smooth complete all as specified and directed. |
| 38 | Demolition of cement concrete ( unreinforced) in Roofs, floors (other than ground floors), tiles including existing roof treatment (screed plaster,& tarfelt of any description) and removing to a distance exc. 500 m and n.exc. 5 Km from site complete all as specified and directed. |
| 39 | M & L 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in benching,kerbs and levelling course etc over roof surface complete all as specified and as directed |
| 40 | M & L for 10 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions (Note:Water proofing compound shall be measured and paid seprerately under respective item of \\"BoQ\\") |
| 41 | M&L for hybrid (acrylic+ polyurethene) based waterproofing flexible liquid applied membrane single component, three coat system reinforced with fibre mesh having crack bridging upto 2mm and elongation upto 200% and dry film thickness(DFT) 1000 microns with Heat reflective system for all types of exposed roof slabs (new and old) terraces (sloped and flat) complete all as specified and directed. |
| 42 | M&L for hybrid (acrylic+ polyurethene) based waterproofing flexible liquid applied membrane single component, three coat system having crack bridging upto 2mm and elongation upto 200% and dry film thickness(DFT) 1000microns with Heat reflective system for chajjas/Parapet walls (new and old) terraces (sloped and flat) complete all as specified and directed. Please Enable Macros to View BoQ information |