| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 2 | M & L brick work with fly ash bricks, Straight or curved onplan exc 6m mean radius,built in 1:6 in cement mortar all as Specified and Directed |
| 3 | M & L for brick work with sub class \\"B\\" brick (old size) straight or curved on plan to any radius in half brick thick walls built in CM 1:4 to any radius complete all as specified and directed. |
| 4 | Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 5 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 6 | M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 7 | M&L for Preparation of Newly Plastered surfaces of Wall and applying Two coats of Oil Bound Distemper over a coat of primer all as specified and directed. |
| 8 | M&L for preparation of newly plastered surfaces of wall applying two coat of white wash over a coat of primer all as specified and directed. |
| 9 | M&L for preparation of old distempered surfaces of walls and applying one coat of oil bound distemper on walls all as specified and directed. |
| 10 | M&L for Preparation of old surfaces of Wall and applying One coat of Cement Base Paint on walls all as specified and directed by Engineer-in-Charge. |
| 11 | M&L for Complete Removal of existing treatment including preparation of old treated surface and applying Two coat of oil bound distemper over 3 mm thick wall care putty including preparation all as specified and directed. |
| 12 | M&L applying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly plastered wall surfaces/ old decorated wall surfaces, in case of old decorated wall surfaces includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed. |
| 13 | M&L preparation of old decorated Steel painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 14 | M&L preparation of old decorated wooden painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 15 | M & L for two coats of distempering with 1st quality washable plastic acrylic distemper (ready mixed) having VOC content less than 50gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification after preparation of plastered surface including a coat of primer on prepared surfaces including, rubbing with sand paper and applying and including 2 mm putty and old painting removal all as directed by Engr-in-Charge. |
| 16 | M&L for preparation of old decorated wall panelling, railing and as per site requirement etc and applying one coats of wooden french polish with gloss finish all as specified and as directed by Engr-in-charge. |
| 17 | M&L for preparation of existing sunken floor treatment incl plaster and removal of all debris with the following specification and sequence complete all directed by Engr-In-Chrg (a) Cleaning internal surface areas of sunken thoroughly to remove all dirt & loose materials by various mechanical/manual means.(b) Providing and making fillets at the junction of the walls and the slabs using CM 1:4. (c) Laying protection plaster 15mm th. in CM 1:4 on floor and wall with integral water proofing compound (d) Applying two coats of Epoxy resin polymer modified cementitious coating like brushbond of FOSROC/ Dr. Fixit Fastflex/ Bostic Powermix both on floor and wall of sunken. |
| 18 | Demolition of cement concrete unreinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 19 | M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate as in filling of sunken floor etc and mass concrete complete all as specified and directed. |
| 20 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in Sub base flooring 100 mm thick surface finished even and smooth complete all as specified and directed. |
| 21 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed. |
| 22 | M&L for Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment along external wall where the apron is not providedusing chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed. |
| 23 | M&L for Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre includingdrilling and plugging holes etc. in apron complete all as specified and directed. |
| 24 | M&L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. |
| 25 | M&L for Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment Of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed. |
| 26 | M&L for Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed. |
| 27 | M&L Anti-termite Treatment for Switch boards including removing the cover carefully and inserting adequate amount of chemical (powder) and closing the cover complete all as specified and directed |
| 28 | M&L for Making corner fillets, Grating, Nahani trap, Gully trap with Polymer modified cementitious (PMC) mortar (PMC:C:M :: 1:2:4 by weight) at all joints of horizontal and vertical surface and doing bore packing with PMC mortar complete. And M&L for application of one coat of Acrylic Polymer Modified Cementitious (APMC) slurry (APMC:C :: 1:2 by weight) coating over the RCC slab surface and carried upto finished floor level on vertical portion (walls) complete and also including new any dia, size, PVC Pipe, grating, NT, GT, ETC as site requirement all as specified and directed all as directed by Engr-in-Charge. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 30 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base flooring 100 mm thick complete all as specified and directed. |
| 31 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed. |
| 32 | M&L for Machine cut kota stone slab flooring mirror finished 18-20 mm thick (each slab not less than 0.25 Sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 15 mm thick screed bed or bedding layer in cement mortar 1:6, including rubbing and polishing complete all as specified and directed. |
| 33 | M&L for Machine cut kota stone in riser of steps, skirting, dado and pillar mirror finished 18-20 mm thick over cement base rendering laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 10 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and polishing complete all as specified and directed. |
| 34 | M& L Grinding and polishing mirror-ploished laidover with coloured wax for kota stone flooring complete all as specified and directed by Engr-in-Charge. |
| 35 | M/L Vitrified Ceramic tiles 10 mm thick (square/ rectagular) dark/light colour shade polished,area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floors over 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 36 | M&L Vitrified Ceramic tiles 10 mm thick on vertical surface of wall of size not exceeding 0.36 sqm,as in dado/skitting including 10 mm thick rendering in CM 1:4 complete all as specified and directed |
| 37 | M&L for Non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 38 | M&L for Non skid ceramic coloured tiles vertical surfaces area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm as skirting non skid ceramic tiles ncluding 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 39 | M&L for Non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 40 | M&L for Non skid ceramic coloured tiles vertical surfaces area of each tile exceeding 0.11 sq m but not exceeding 0.16 sqm as skirting non skid ceramic tiles ncluding 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 41 | M&L for 10 mm thick Double Charged Light shade vitrified ceramic tiles in floors, tiles size 600 mm x 1200 mm set & jointed in neat cement slurry and pointed in coloured cement to match as in floors over 20mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 42 | M&L for 10 mm thick Double Charged Light shade vitrified ceramic tiles on vertical surface of wall of size 600mm x 1200mm as in dado/skitting including 10 mm thick rendering in CM 1:4 complete all as specified and directed |
| 43 | M&L for anti non skid ceramic coloured tiles matt finish of design as approved by GE 10 mm thick (square) area of each tile size 600mm x 600 mm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 20 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 44 | M&L for glazed ceramic coloured tiles size 600mm x 450mm x 10 mm thick on vertical surface such as dado /skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment. |
| 45 | M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick coloured on vertical surface such as dado /skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. |
| 46 | M&L for 20 mm thick granite (of any type & colour) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms/shelves incl screed bed 15 mm th. in CM (1:6) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 47 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations |
| 48 | Taking up & down GI steel tubing & connections including cleaning for refixing or removal to store for 15mm bore of pipe complete all as specified and directed. |
| 49 | Taking up & down GI steel tubing & connections including cleaning for refixing or removal to store 20mm bore of pipe complete all as specified and directed. |
| 50 | Taking up & down GI steel tubing & connections including cleaning for refixing or removal to store 25mm bore of pipe complete all as specified and directed. |
| 51 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed. |
| 52 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed. |
| 53 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 25 mm bore of pipe complete all as specified and directed. |
| 54 | Supplying and laying of 20mm bore dia, CPVC pipes SDR 11 & plain and brass CPVC SDR 11 fittings incl all brass reducers,unions,Tee fixed on walls/ceiling or laid in floors, etc, complete all as specified and directed. |
| 55 | Supplying and laying of 25mm bore dia, CPVC pipes SDR 11 & plain and brass CPVC SDR 11 fittings, incl all brass reducers,unions,Tee fixed on walls/ceiling or laid in floors, etc, complete all as specified and directed. |
| 56 | Dismantling PVC water tanks exc 250 ltr but not exc 500 ltr capacity and removing to store |
| 57 | Dismantling PVC water tanks exc 500 ltr but not exc 1000 ltr capacity and removing to store |
| 58 | S&F 500 ltr capacity Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I |
| 59 | S&F 1000 ltr capacity Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I |
| 60 | Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete. |
| 61 | Taking down bib tap/wash basin pillar tap/ stop cock/mixture tap and refixing the same after repair/replacement of spindles for 15 mm bore size complete all as specified and directed. |
| 62 | S&F in repair bib tap cast copper alloy chromium plated with crutch or butterfly handle fixed to 15 mm dia GI tube/CPVC pipe all as specified and directed. |
| 63 | S&F in repair bib tap cast copper alloy chromium plated with crutch or butterfly handle fixed to 15 mm dia GI tube/CPVC pipe all as specified and directed. |
| 64 | S&F in repair bib tap 2 in 1 type cast copper alloy chromium plated with crutch or butterfly handle fixed to 15 mm dia GI tube/CPVC pipe all as specified and directed. |
| 65 | S&F in repair bib tap 2 in 1 type cast copper alloy chromium plated with crutch or butterfly handle fixed to 15 mm dia GI tube/CPVC pipe all as specified and directed. |
| 66 | S&F in repair 15 mm fancy type pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered ‘Hot’ or ‘cold’ with long screwed shanks and fly nuts . |
| 67 | S&F in repair 15 mm fancy type pillar taps chromium plated cast copper alloy of long swan neck type & quarter turn type with or without lettered ‘Hot’ or ‘cold’ with long screwed shanks and fly nuts . |
| 68 | S & F in repairs CP brass center hole mixer for wash basin for mixing hot and cold water screwed down for iron pipe and fixed for 15 mm bore pipe size complete all as specified and directed |
| 69 | S & F in repairs brass CP wall mixer for mixing hot & cold water with provision for over head shower with arm and long bend pipe and wall flanged screwed down for iron pipe of 15 mm bore size complete all as specified and directed. |
| 70 | S & F in repairs brass CP kitchen sink mixer for mixing hot & cold water with provision screwed down for iron pipe of 15 mm bore size complete all as specified and directed. |
| 71 | S&F in repair chromium plated wall mixer 3-in-1 system telephonic, connecting legs and wall flange complete all as specified and directed. |
| 72 | S&F in repair 15 mm fancy type stop valve/angle valve cast copper alloy chromium plated screwed high pressure with crutch or butter fly handle screwed both ends for iron or union and fixed to 15 mm GI tube complete all as specified and directed by Engineer-in-Charge. |
| 73 | S&F in repair 15 mm fancy type stop valve/angle valve cast copper alloy chromium plated screwed high pressure with crutch or butter fly handle screwed both ends for iron or union and fixed to 15 mm GI tube complete all as specified and directed by Engineer-in-Charge. |
| 74 | S & F in repairs stinless steel tie hangers, fixed to wall and including all accessories and complete all as specified and directed by Engr-in-Charge. |
| 75 | S & F in repairs glass brush stand size 150mm x150mm, fixed with wall and including all accessories and complete all as specified and directed by Engr-in-Charge. |
| 76 | S & F in repairs stainless steel towel rack dual foldable any shape and any size as required for ground/bath as directed by Engr-in-Charge to fixed with and including all accessories. |
| 77 | S & F PVC bath cabinet with looking mirror overall size 450 x 650 mm all as specified and as approved fixed to wall complete. |
| 78 | S&F in repair 20mm dia ball Brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed as in PVC Service tanks all as directed. |
| 79 | S&F in repair 25mm dia ball Brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed as in PVC Service tanks all as directed. |
| 80 | S & F in repairs 20mm bore gun metal gate valves with iron wheel head screwed both ends for iron pipe and fixed. |
| 81 | S & F in repairs 25mm bore gun metal gate valves with iron wheel head screwed both ends for iron pipe and fixed. |
| 82 | S&F in repairs PVC connection 15mm size with PTMT nuts, of 450mm length complete all as specified and directed. |
| 83 | S & F in repairs, vitreous china wash basin, white, flat back, size 550x400mm with brackets, inc.cutting for fixing & pinning in ends of brackets complete all as directed by Engr-in-Chrg |
| 84 | S&F vitreous pedestal china for WHB as per suilable for WHB size as per site requirement complete all as specified and directed. |
| 85 | S & F in repairs, vitreous china wash basin oval type, white, for fixing in shelves standard size inc.cutting for fixing & pinning in ends of brackets complete all as directed by Engr-in-Chrg |
| 86 | S&F WHB table top or under counter-type any shape and any size including coupling complete all as specified and directed by Engr-in-Charge. |
| 87 | S&F in repairs viterious china squatting pan orissa pattern size 580x440mm white integal foot rest including concrete bedding & including P or S trap 100mm complete all as directed by Engr-in-Charge. |
| 88 | S & F in repairs, vitreous china wash down water closet pan (pedestal pattern), white, incl 'P' or 'S' trap and plastic water closet seat, black, closed pattern with flat bottom and cover & MS chromium plated or aluminised hinging device, complete all as directed by Engr-in-Charge. |
| 89 | S & F in repair Europian WC floor mounted cascade pattern vitreous china with dual core flushing cistern incl all fitting flush pipe etc complete all as specified and directed. |
| 90 | S & F in repair Vitreous china rimless wall hung pedestal pattern water closet incl seat cover, rack bolts hinges incl all accessories incl slim type flushing cistern wall hung 08 to 10 Ltr Capacity compatible with 39mm drainage pipe complete all as directed |
| 91 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed. |
| 92 | S&F Bottle trap chromium plated for WHB/urinal etc as per approved quality all as per specified and directed |
| 93 | S&F Vitreous China urinals, full stall type urinal, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement including waste pipe complete all as specified and directed. |
| 94 | S & F in repairs Vitreous China urinals, bowl type flat back size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement etc complete all as sapecified and directed. |
| 95 | S&F in repair PVC low level flushing cistern (white) 10 Ltrs capacity with inlet, ball valve, float and handle internal fitting, push button operated type with and including brackets etc complete. |
| 96 | S/F in repair CP health faucet with flex pipe and hand shover ,the length of hose 1.50 mtr fitted to the tap.complete all as specified. |
| 97 | S/F in repair CP health faucet with flex pipe and hand shover ,the length of hose 1.50 mtr fitted to the tap.complete all as specified. |
| 98 | S&F in repairs EWC seat cover of any pattern including cover and Mild steel chromium plated hinging devices of any colour all as specified and directed. |
| 99 | S&F in repairs EWC seat cover of any pattern including cover and Mild steel chromium plated hinging devices of any colour all as specified and directed. |
| 100 | S&F Iin repair CP Grating doom 75 mm dia with PVC (SWR) nahani/floor trap incl jointing with solvent cement complete all as specified and directed. |
| 101 | S&F in repair CP brass towel rail `D’ type 60Cm long fixed to wall all as spd and directed by Engr-in-Charge. |
| 102 | S&F in repair CP brass towel rail `D’ type 60Cm long fixed to wall all as spd and directed by Engr-in-Charge. |
| 103 | S&F Chromium plated Towel Ring fixed with and including Chromium plated brass screws and wooden/plastic cleats(Minimum weight 90 gms). |
| 104 | S&F Chromium plated Towel Ring fixed with and including Chromium plated brass screws and wooden/plastic cleats(Minimum weight 90 gms). |
| 105 | S&F in repair soap dish any type fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 106 | S&F in repair soap dish any type fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 107 | S&F Looking mirror 5.5 mm thick of selected quality glass of size 600 x 450 mm bevelled edge ,mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screw and cup washers including aluminium anodized frame complete all as specified and directed. |
| 108 | S & F in repair bevelled edge Looking mirror of any size without frame of selected quality glass mounted on wall with chromium plated stainless screws complete all as specified and directed |
| 109 | S&F in repair brass shower rose 125 mm dia any type fixed to plugs with chromium plated brass screws complete all as specified and directed |
| 110 | S&F in repair stainless steel overhead shower rose square type 150/200 mm with CP arms 400/350 mm long as per ground requriment etc complete all as specified and directed by Engr-in-Charge. Make Jquar, cera or equivalent. |
| 111 | S&F as in repair glass shelf assembly consisting of 5.5mm thick sheet 12cm wide with chromium plated bracket guard railing 60cm long complete all as specified and directed |
| 112 | S&F as in repair glass shelf assembly consisting of 5.5mm thick sheet 12cm wide with chromium plated bracket guard railing 60cm long complete all as specified and directed. Make Jquar, cera or equivalent. |
| 113 | S&F as in repair cornner glass shelf of size 9\\"*9\\" shelf and frond,circle in design fixed over chromium plated brackets of heavy duty with frond linings with glass fixed in wall with necessary screws complete all as specified and directed. |
| 114 | S&F as in repair cornner glass shelf of size 9\\"*9\\" shelf and frond,circle in design fixed over chromium plated brackets of heavy duty with frond linings with glass fixed in wall with necessary screws complete all as specified and directed. |
| 115 | S & F in repair Toilet paper holder, S S box type complete all as specified and directed |
| 116 | S & F in repair LId of water tank capacity of 500/1000/2000 Ltrs including necessary cleats/clamps complete all as specified and directed. |
| 117 | M&L for cleaning of water storage tank of capacity upto 500 ltrs mountred on roof incl removal of all vegetation if any, loose dirt and all other materials with help of tank cleaning motor jet pressure machine and pouring bleaching powder @0.25 kg per tank with date of cleaning clearly written over tank incl Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in positionall as directed by Engr-in-Chrge. |
| 118 | M&L for cleaning of water storage tank of capacity exc 500 ltr but not exc 1000 ltrs ,size,type etc.mountred on roof incl removal of all vegetation if any, loose dirt and all other materials with help of tank cleaning motor jet pressure machine and pouring bleaching powder @0.25 kg per tank with date of cleaning clearly written over tank ncl Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in positionall as directed by Engr-in-Chrge. |
| 119 | S & F in repair LDPE waste pipe for WHB, sink, urinal etc. pipes of pressure rating 6 kgf/sq. cm complete. |
| 120 | S & F in repair HDPE waste pipe 32 mm dia for EWC,Flushing cistern etc. pipes of pressure rating 6 kgf/sq. cm complete. |
| 121 | S & F in repair HDPE pipe 40 mm dia of pressure rating 6 kgf/sq. cm complete. |
| 122 | S & F in repair 32mm dia Bottle trap of PTMT having minimum water seal of 25 mm all as spd. |
| 123 | S & F in repair 32mm dia bore Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed as in repairs |
| 124 | Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete,PVC ) set in cement mortor for any size & type complete all as specified and directed. |
| 125 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or in floors of 75 mm bore of pipe etc complete all as specified and directed. |
| 126 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls or in floors of 110 mm bore of pipe etc complete all as specified and directed. |
| 127 | S&F PVC (SWR) bends any radius of 75 mm bore with out access door complete all as specified and directed. |
| 128 | S&F PVC (SWR) bends any radius of 110 mm bore with out access door complete all as specified and directed. |
| 129 | S&F PVC (SWR) bends any radius of 75 mm bore with access door complete all as specified and directed. |
| 130 | S&F PVC (SWR) bends any radius of 110 mm bore with access door complete all as specified and directed. |
| 131 | S&F PVC (SWR) vent cowl 75 mm bore complete all as specified and directed. |
| 132 | S&F PVC (SWR) vent cowl 100 mm bore complete all as specified and directed. |
| 133 | Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to or from store complete all as specified and directed |
| 134 | Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to or from store complete all as specified and directed |
| 135 | S & F for solid PVC door frame of size 50x47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supplied and fixing in opening as specified and shown on drawing made on section 8 of SSR 2010 Part-II complete all as specified and directed |
| 136 | S & F factory made solid panel PVC door shutter 30 mm thick style consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, S & F in the frame as per specifications and shown on drawing in section 8 of SSR-2010 Part-II complete all as specified and directed |
| 137 | S&F 100 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised type B-21 complete all as specified and directed. |
| 138 | S&F 150 mm size extruded aluminium alloy handles fabricated type anodised of complete all as specified and directed. |
| 139 | S&F 150 mm long aluminium,anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 140 | S&F in repair 100 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised type B-21 complete all as specified and directed. |
| 141 | S&F in repair 150 mm size extruded aluminium alloy handles fabricated type anodised of complete all as specified and directed. |
| 142 | S&F in repair 150 mm long aluminium,anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 143 | S&F in repair 300 mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 144 | S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4 mm fixed with stainless steel wire staples or with necessary beads complete all as specified and directed. |
| 145 | S&F in repair fancy type heavy duty easy-to-fit wall-to-bracket holder for for 20/25mm dia stainless steel curtain rod, as per site requuirement approved by Engr-in-Charge complete all as specified and directed |
| 146 | S&F in repair for 25mm dia Stainless Steel Curtain Rod with brackets on both ends incl T/D of any type old curtain rods and making good disturbed surfaces with cement mortar or putty complete all as specified and directed |
| 147 | S&F in repairs 18/19 mm thick high density PVC/ WPC solid fibre board with prelaminated PVC sheet as Kitchen cupboard and frame including taking down the old cupboard shutters and removing to store complete all as specified and directed. |
| 148 | M&L in repair 6 mm thick ACP sheet, fixed with screws to aluminium door frame work incl taking down old aluminium doors etc. complete all as specified and directed. |
| 149 | M&L in repair 18/19 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work incl taking down old cupboards etc. complete all as specified and directed. |
| 150 | S&F 6 mm thick teak wood liping 18/19 mm width prelaminated particle board fixed with screws complete all as specified and directed. |
| 151 | S & F in repair Continuous (piano) hinges, 40 mm width of mild steel, bright finish or electrogalvanisd complete all as specified and directed. |
| 152 | S&F in repaur Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed. |
| 153 | S&F 100 mm long Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws |
| 154 | S & F magnetic catcher catcher with nut and screw of mild steel bright finish all as specified and directed. |
| 155 | S & F 40 mm dia cupboard knobs fixed with nuts screw and washer of mild steel bright finish complete all as specified and directed. |
| 156 | Hacking out old broken glass (any thickness, size quality or description) form wooden frames or stone, concrete or brick surrounds glazed with oil putty or fixed with beads complete all as specified and directed. |
| 157 | S&F 3 mm thick sheet glass ordinary quality and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 158 | S&F 3 mm thick figured glass pin headed type and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 159 | S&F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 160 | S&F in repair floor door stopper of aluminium alloy body and tongue, anodised, over all length of cover plate 140 mm with hard drawn steel spring fixed in door etc complete all as specified and directed. |
| 161 | S&F in repair 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed |
| 162 | S & F in repair stainless steel SC-Premium Dual Edge - 8 PIN cloth hanger bathroom wall door Hooks, complete all as specified and directed. |
| 163 | S&F in repairs door seal with aluminium beading and 50 mm wide rubber seal complete fixed to aluminium/ Wooden doors complete all as specified and directed. |
| 164 | Taking down shutter of any description not exceeding 1 sqm each leaf and refixing, in same opening after easing and adjusting building hard ware etc complete all as specified and directed |
| 165 | Taking down shutter of any description exceeding 1 sqm but not exiding 2 Sqmeach leaf and refixing, in same opening after easing and adjusting building hard ware etc complete all as specified and directed |
| 166 | S&F 2nd class hardwood Beads, straight (any size) for glazed or gauzed joinery, renewed, including mitres etc., and removing old beads to Store |
| 167 | M&L Mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,frame work of watertanks and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 168 | S&F in repairs Aluminium Mortice lock 2 lever, vertical type, size 100 mm with escutcheon plates and two keys complete all as specified and directed. |
| 169 | S&F in repairs Aluminium Mortice lock 4 lever, vertical type, size 100 mm with escutcheon plates and two keys complete all as specified and directed. |
| 170 | S&F in repair floor door stopper of brass body and tongue, anodised, over all length of cover plate 140 mm with hard drawn brass spring fixed in door etc complete all as specified and directed. |
| 171 | S&F in repair 250 mm long brass, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, brass extruded section and fixing bolts and sliding bolts of extruded section brass complete all as specified and directed |
| 172 | S&F in repair 100 mm long butt hinges brass with galvanised mild steel hinge pin anodised type B-21 complete all as specified and directed. |
| 173 | S&F in repair 150 mm size extruded brass handles fabricated type anodised of complete all as specified and directed. |
| 174 | S&F in repair 150 mm long Brass barrel tower bolts of extruded section complete all as specified and directed. |
| 175 | Dismantling of wall and ceiling boards (fibre,pulp,insulation,etc)or insulation boards/slabs/blankets,any thickness,including cover fillets. complete alll as specified and directed |
| 176 | S&F 12 mm thick plain Gypsum Board False Ceiling with GI frame including all necessary drilling cutting to fix electric items complete all as specified and directed with following:- (a) GI Grid channel 30x25x20 mm of 24 gauge fixed with rawl plug and screw 450 mm centre to centre alongwith perimeter walls. (b) GI channel made to shape 50x40x40 mm of 24 gauge placed @ 600 mm centre to centre from perimeter at wall except long wall (in one span). (c) GI intermediate runners of size 45x10x10 mm of 24 gauge fixed @ 1200 mm centre to centre leaving frame of one side walls (in other span). (d) GI sheet 25 mm wide and 20 mm gauge suspended fixed with steel fastner to roof ceiling and 1200 mm centre to centre including pluging of RCC Slab/GI based shed/truss/purleen. (e) 12 mm thick gypsum board filling joints with POP and finishing complete with two coat of plastic emulsion paint over one coat of primer on ceiling and including 2mm thickness putty. |
| 177 | Providing & fixing false ceiling at all heights with Semi perforated 12 mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 1200 x 600 mm of approved texture,design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-inCharge. |
| 178 | M&L for applying 3 mm thick wall care Putty in two layers on ceiling surfaces absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper including and applying two coats of Oil bound distemper on ceiling complete complete all as specified and directed. |
| 179 | M&L 4 mm thick non asbestos fibre cement board fixied to GI/Aluminium framework with screws fixed in ceilings of size 600 x 600mm board incl anodised aluminium snap grid frame work for false ceiling all as specified and directed by Engr-In-Charge |
| 180 | S&F solid PVC wall lining consisting of 5mm thick single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame and including 5 mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and also including dismantling of wall panels and directed by Engr-in-Charge. |
| 181 | S&F 12mm thick Toughned glass as in hinged doors, partitions automatic doors, windows and similar work etc including cutting to shape, drilling holes required completed and also including SS handles requried dia, size and shape all as specified and directed as in Engr-in-Charage. |
| 182 | M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. |
| 183 | Supply and fixing factory made UPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension,including Pinhead Glass with thickness of 4mm required for fixing & louvers strips, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc.Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Note: For UPVC frame, sash and mullion extruded profiles minus 5% tolerance in imension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made and 4mm thick glazing with selected quality glass and including taking down aluminium/wooden/steel/uPVC ventilator (Note: The unit rate quoted by contractor include cost of glass and includes all other connected accessories). |
| 184 | Supply and fixing factory made uPVC white colour casement door with 3D hinges made of (big series) frame 67 x 64 mm & ash 67 x 110 mm both having wall thickness of 2.3+ or - 0.2 mm and sinle glazing bead/double glazing bead of appropriate dimension. (area of ddor up to 2.00 Sqm) comprising of uPVC multi-chambered frame, sash and million (where ever required) ex truded rofiles duly reinforced with 1.60+ or - mm thick galvanied mild steel section made from roll forming process of requied length (shape & size according to UPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, Zinc alloy white powder coated 3D higes and one handle on each side of panels along with zick plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, GI fasterners 100 x 8 size for fixing frame to finished wall and necessary stainless stell screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and draingage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete and including WPC/PVC board as required size and thickness and 4 mm thickness glass and including taking down aluminium/wooden/steel/uPVC door all as secified and directed by Engr-in-Charge. |
| 185 | Providing and fixing factory made uPVC white colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 4mm thick glazing with selected quality glass or tinted glass. (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories and including taking down aluminium/uPVC/wooden/steel windows/ventilator all as directed by Engr-in-Charge. |
| 186 | Supply and fixing factory made UPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. and provided with Clear glass of Saint Gobain / Modiguard make with thickness of 4mm and stainless steel wire cloth of 0.19mm nominal dia. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified.Note: For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made and 4mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor include cost of glass and includes all other connected accessories and taking down aluminium/wooden/steel/uPVC windows) all as directed by Engr-in-Charge. |
| 187 | S&F Powder coated Aluminium anodised glazed side hung door with following specifications and making good the adjacent surfaces complete including taking down all as specified and directed.(a) Cross section of chowkhat/frame 101.60x44.45x2mm thick(b) Cross section of hanging and meeting style 83x44x2mm thick.(c) Top rail of cross section 114x44x2mm thick(d) Bottom rail of cross section 114x44x2mm thick.(e) Lockingrail (middle rail) rail of cross section 100x44x2mm thick.(f) 5 mm thick tinted glass of approved make(g) Aluminium handle elsc type -02 Nos per shutter (inside and outside) (h) Aluminium door stopper heavy duty-01 Nos per shutter.(i) Aluminum tower bolt 200 mm long-01 Nos per shutter (inside)(j) Mortice brass Lock- 01 Nos per shutter with key superior quality as spd by Engr-In-Charge |
| 188 | Supply and fixing factory made uPVC white colour/selected colour (Jali door) frame 67 x 64 mm & ash 67 x 110 mm both having wall thickness of 2.3+ or - 0.2 mm and sinle glazing bead/double glazing bead of appropriate dimension. (area of ddor up to 2.00 Sqm) comprising of uPVC multi-chambered frame, sash and million (where ever required) ex truded rofiles duly reinforced with 1.60+ or - mm thick galvanied mild steel section made from roll forming process of requied length (shape & size according to UPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, Zinc alloy white powder coated 3D higes and one handle on each side of panels along with zick plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, GI fasterners 100 x 8 size for fixing frame to finished wall and necessary stainless stell screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and draingage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete, including taking down all as secified and directed by Engr-in-Charge. |
| 189 | S&F Powder coated Aluminium anodised Jali door with following specifications and making good the adjacent surfaces complete, including taking down all as specified and directed.(a) Cross section of chowkhat/frame 101.60x44.45x2mm thick(b) Cross section of hanging and meeting style 83x44x2mm thick.(c) Top rail of cross section 114x44x2mm thick(d) Bottom rail of cross section 114x44x2mm thick.(e) Lockingrail (middle rail) rail of cross section 100x44x2mm thick.(f) Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm (g) Aluminium handle elsc type -02 Nos per shutter (inside and outside) (h) Aluminium door stopper heavy duty-01 Nos per shutter.(i) Aluminum tower bolt 200 mm long-01 Nos per shutter (inside)(j) Mortice brass Lock- 01 Nos per shutter with key superior quality as spd by Engr-In-Charge |
| 190 | S&F Powder coated Aluminium sliding glazed windows with three track and three shutter sliding with following specifications and making good the adjacent surfaces complete, including taking down all as specified and directed.(a) Three way track for sliding shutters of Cross section 91.8 mm x31.8 mm x1.1 mm thick.(b) Sliding shutters frame of Cross section 40 mm x18 mm x1.1 mm thick(c) 5 mm thick tinted glass of approved make(d) IDPE rubber gasket for fixing of glass.(e) Locking cleats per shutter-01 Nos.(f) Sliding rollers per shutter-02 Nos.(g) Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.56mm for shutters-01 Nos(h) Fixing screws for frame with wall per window-08 Nos |
| 191 | S&F in repair door closer hydraulically regulated designation No 2, universal type, suitable for door shutter of weight not more than 60 Kg of aluminium (extruded section body) complete all as specified and directed. |
| 192 | S&F 7 mm thick aluminium grills of god quality surrounded by aluminium 'C' channel with mesh size 75 X 75mm incl taking down old grills of any type complete all as specified and directed. |
| 193 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings i.e removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made for conditions separately ) and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing without andulations complete all as specified and directed.( Note:- All credit materials should be deposited in MES yard as available on work site the same materials should be issued to contractor through gate pass as per contract schedule of credit materials against contract agreement or taken on ledger with approval by accepting officer). |
| 194 | Material and labour for cutting chasing,pinning of brick/ stone/concrete wall at any height wall cutting and chases for concealed wiring for 20/25 mm PVC conduit dia pipe,water tubing,etc and making good to facings where required and pointing in cement motor 1:3 to ends or edges of landigs,wall surfaces etc,cutting not exc 10 cm girth and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed |
| 195 | M&L for point wiring using approved colour coding incl providing circuit wiring with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conf to IS-694/1990 unsheathed, multistranded, single core, copper cable 1100 volts grade cables drawn through in PVC Conduit 20/25 mm dia medium grade ISI marked (MMS) at any height/places and all accessories are concealed in walls / roofs / floors / ceiling etc. including suitable arrangements for flush mounting modular MS/GI boxes as per site requirement/suitable for modular top cover and frame for fixing of modular switches,sockets,fan regulators, blank plate etc and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with necessary putty for smooth finishing complete all as specified and directed for the following:- (a) One light point controlled by one 10amps switch. |
| 196 | (b) One fan point controlled by one switch 10 amps, and one regulator. |
| 197 | (c) One exhaust fan point controlled by one 10 amps switch . |
| 198 | (d) One 5 pin 6 amps socket point controlled by one 10 amps switch on independent board . |
| 199 | (e) One 5 pin 6 amps socket point controlled by one 10 amps switch on same board . |
| 200 | (f) One bell/buzzer point controlled by one bell push. |
| 201 | (g) One light point controlled by two 2 way switches/bed switch point |
| 202 | All as per item No.198 & 199 above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm incl circuit wiring complete all as specified and directed for the following:-(a) One 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switch on independent board. |
| 203 | (b) One 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switch on same board. |
| 204 | All as per item No.199 above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm incl circuit wiring complete all as specified and directed. |
| 205 | M&L for point wiring using approved colour coding incl providing circuit wiring with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conf to IS-694/1990 unsheathed, multistranded, single core, copper cable 1100 volts grade cables drawn through PVC casing and caping 20/25 mm width double locking medium grade ISI marked (MMS) at any height and all accessories such as Tee,bend,short piece & elbow on surface on walls / roofs / floors / ceiling etc. including providing suitable arrangements for flush mounting modular MS boxes as per site requirement/suitable for modular top cover and frame for fixing of modular switches,sockets,fan regulators, blank plate etc and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with necessary putty for smooth finishing complete all as specified and directed for the following: (a) One light point controlled by on switch |
| 206 | (b) One fan point controlled by one switch and regulator |
| 207 | (c) One exhaust fan point controlled by one switch. |
| 208 | (d) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . |
| 209 | (e) One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . |
| 210 | (f) One bell point controlled by one bell push. |
| 211 | (g) One light point controlled by two 2 way switches. |
| 212 | All as per item No.208 & 209 above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm and incl providing circuit wiring complete all as specified and directed for the following:- (a) One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board. |
| 213 | (b) One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board. |
| 214 | All as per item No.208 above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm incl providing circuit wiring complete all as specified and directed. |
| 215 | Supply & fixing and fixing in repairs modular type switch 10 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 216 | Supply & fixing and fixing in repairs modular type switch 10 Amps ,2way,single pole,1 module,240V,AC, ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 217 | Supply & fixing and fixing in repairs modular type bell push 6 Amps,1 module, single pole, 240 volts,AC, ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 218 | Supply & fixing and fixing in repairs modular type switch 16 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 219 | Supply & fixing and fixing in repairs modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 220 | Supply & fixing and fixing in repairs modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module,240V,AC ISI Marked complete all as specified and directed by Engr-in-Charge |
| 221 | Supply & fixing and fixing in repairs red color lighting indication lamp 6 Amps, single pole,240volts,AC,50 Hz suitable for 1 module ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 222 | Supply & fixing and fixing in repairs modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 0 to 4/5 steps, ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 223 | Supply & fixing and fixing in repairs call bell AC, 230 Volts single pole, multi music type ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 224 | Supply & fixing and fixing in repairs call bell ding dong AC, 230 Volts single pole, multi music type ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 225 | Supply & fixing and fixing in repairs angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed by Engr-in-Charge. |
| 226 | Supply & fixing and fixing in repairs ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 227 | Supply & fix decorative box type 20 watt light fitting,blue coloured end caps, pre-wired and including providing single/double side LED tubelight(tube rod) white/warm 20 watt-01 No made of aluminium extrusion with high efficient LED driver,IP-20, including PVC/Wooden round/square block -02 Nos and connected with LED fitting to ceiling rose and including removing old unserviceable fitting complete all as specified and directed by Engr-in-Charge. |
| 228 | Supply & fix decorative box type 9 watt light fitting,blue coloured end caps, pre-wired providing single side LED tube 9 watt-01 No, and including PVC/Wooden round/square block -02 Nos and connected with LED fitting to ceiling rose and including removing old unserviceable fitting complete all as specified and directed by Engr-in-Charge. |
| 229 | Supply and fixing, in repairs 20 watt LED pride plus batten white decorative type,high quality materials,240V,50Hz, and slim integrated body,easy to install,,PC diffuser and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed by Engr-in-Charge. |
| 230 | Supply & fixing, in repairs 40 watt LED light fitting white lighting, high quality materials and intergrated design, PC diffuser, reliable and robust housing structure, easy to install, efficency 125 lm/w necessary arrangements for fixing with LED fitting to ceiling rose complete all as specified and directed by Engr-in-Charge. |
| 231 | S & F Energy efficient and energy saving new generation 10 watts LED bulk head light fitting IP-65 luminaire with opel diffuser pre-wired of luminaires including LED light driver and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed by Engr-in-Charge. |
| 232 | Supply & fixing , in repairs LED bldg secruity light fitting sensor based of capacity 35 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection and including removing of old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 233 | Supply and fix GI bracket pipe of size 25 to 32 mm dia as suitable medium grade of 1.2 mtr long bent to shape suitable degree of bending as per site requirement with hot or cold bending method of process for making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on wall surfaces and including providing suitable fabricate galvanised flat iron clamps of 20X4 mm thick -02 Nos suitable for fixing at any place/height with hole fastners,nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 234 | Supply & fixing , in repairs in sheet metal enclosure, 415 volts AC,TPN DB, 4 way,8+12 modules, flush mounting with copper busbar, 2 neutral/earth bars links and MCB incomer, and MCB SPN/SP/TPN as outgoing and complete for IP43&54 DBs protection and including removing old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed by Engr-in-Charge. |
| 235 | Supply & fixing , in repairs in sheet metal enclosure, double door ,415 volts AC,VTPN DB, 4 way,8+12 modules, flush mounting copper busbar, 2 neutral/earth bars links and MCCB incomer, and MCB SPN/SP/TPN as outgoing and complete for IP43&54 DBs protection and including removing old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed by Engr-in-Charge. |
| 236 | Supply & fixing , in repairs sheet metal enclosure, double door, 240 volts AC,SPN,DB, 12 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed by Engr-in-Charge. |
| 237 | Supply & fixing in repairs sheet metal enclosure, double door, 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed by Engr-in-Charge. |
| 238 | Supply & fix and fixing in repairs and sheet metal enclosure, with acrylic type double door, 240 volts AC,SPN,DB, 4 way, flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer,MCB SPN/DP, and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed by Engr-in-Charge. |
| 239 | Supply & fix and fixing in repairs MCB SP 6 to 32 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed by Engr-in-Charge. |
| 240 | Supply & fix and fixing in repairs MCB SPN 32 to 40 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed by Engr-in-Charge. |
| 241 | Supply & fix and fixing in repairs MCB SPN 40 to 63 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed by Engr-in-Charge. |
| 242 | Supply & fix and fixing in repairs MCB TPN 40 to 63/100 Amps 10 KA,\\"C\\" series,AC,440Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed by Engr-in-Charge. |
| 243 | M & L for sub main wiring complete in repairs with 2 run of 10 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn drawn through and including PVC conduit in concealed ISI marked medium grade(MMS) accessories such as Tee,corner, overlaping connector etc and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 244 | All as per ditto item No 243 but 2 run x 6 sqmm+1 run earth wire complete all as specified and directed. |
| 245 | All as per ditto item No 243 but 2 run x 4 sqmm+1 run earth wire complete all as specified and directed. |
| 246 | All as per ditto item No 243 but 2 run x 2.5 sqmm+1 run earth wire complete all as specified and directed. |
| 247 | All as per ditto item No 243 but 2 run x 1.5 sqmm+1 run earth wire complete all as specified and directed. |
| 248 | Supply & fix and fixing in repairs suitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C 'series, 230 Volts,50Hz suitable for AC's/Geysers complete all as specified and directed by Engr-in-Charge. |
| 249 | Supply & fix and fixing in repairs MCCB, 125 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washers and including removing old unserviceable item complete all as specified and as directed by Engr-in-Charge. |
| 250 | Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed. |
| 251 | S&F for PVC non-metalic rigid conduit incl boxes,junctions boxes 1 to 4 way & terminals but incl of all tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers lock nuts,saddles,pipes hookes etc ISI marked heavy duty of size 20/25 mm dia for LAN,telephone and TV connections cablesincluding cutting,chasses and making good disturbed surfaces to match with existing surfaces with plaster/putty and including removing of old unserviceable item complete all as specified and directed. |
| 252 | Supply & fix and fixing in repairs copper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade 3 core ;2.5 sqmm and including electric connection through PVC conduit in concealed/casing caping in surface from ceiling fan to ceiling rose and including removing old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 253 | Supply & fix and fixing in repairs 40 watts LED post top lantern made in cast aluminium spigot housing with decorative opal polycarbonate diffser and IP65 protection and providing suitable fixing arrangements ,nuts,bolts and washers and including removing old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 254 | Supply & fix and fixing in repairs LED flood light light fitting of capacity 120 Watt LED, light fitting in aluminium PDC housing, toughened glass cover with IP-65 protection and including removing of old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 255 | Supply & fix and fixing in repairs LED flood light light fitting of capacity 100 Watt LED, light fitting in aluminium PDC housing, toughened glass cover with IP-65 protection and including removing of old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 256 | Supply and fixing and in repairs galvanised metal flush box 1/2 module, ISI marked,and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed by Engr-in-Charge. |
| 257 | All as per item No-256 ditto but meteal box 3 module |
| 258 | All as per item No-256 ditto but meteal box 4/5 module |
| 259 | All as per item No-256 ditto but meteal box 6 module |
| 260 | All as per item No-256 ditto but meteal box 8/9 module |
| 261 | All as per item No-256 ditto but meteal box 12 module |
| 262 | All as per item No-256 ditto but meteal box 16 module |
| 263 | All as per item No-256 ditto but meteal box 18 module |
| 264 | Supply and fixing in repairs modular white/wood/glazed type cover plate with frame 1 module,ISI marked and suitable for existing type as per site requirement and incl screws,washears etc and including removing old unserviceable item from existing loaction complete all as specified and as directed by Engr-in-Charge. |
| 265 | All as per item No-264 ditto but modular white/wood/glazed type cover plate with frame 2 module |
| 266 | All as per item No-264 ditto modular white/wood/glazed type cover plate with frame 3 module |
| 267 | All as per item No-264 ditto but modular white/wood/glazed type cover plate with frame 4/5 module |
| 268 | All as per item No-264 ditto modular white/wood/glazed type cover plate with frame 6 module |
| 269 | All as per item No-264 ditto but modular white/wood/glazed type cover plate with frame 8/9 module |
| 270 | All as per item No-264 ditto but modular white/wood/glazed type cover plate with frame 12 module |
| 271 | All as per item No-264 ditto but modular white/wood/glazed type cover plate with frame 16 module |
| 272 | All as per item No-264 ditto butmodular white/wood/glazed type cover plate with frame 18 module |
| 273 | Supply and fix in repairs of PVC/bakalite sheet round cover blanking plate as per site requirement with screws of existing fan junctions/ wiring junctions boxes etc |
| 274 | M&L for preparation of new plastered of wall/ceiling or concrete surface of walls or concrete and applying two coats of 3 mm thick wall care putty complete all as specified and directed |
| 275 | M&L for preparation of old decorated surface of wall and apply two coats of white wash complete all as specified and directed |
| 276 | Fixing only and connecting electric meters 10-60 Amps any type single or three phase complete all as specified and directed and including providing necessary accessories complete all as specified and as directed. |
| 277 | Taking down carefully existing electric meters of any type/capacity from work site and deposit to MES store yard/ Charge holder without damage for safe custody and supply and fixing single phase electronic meters temper proof LCD display with polycarbonate cover 230Volts,10-60 Amps, accuracy class-I,50Hz, confirming to IS-13779,IP-54,with parameters to show data,time current reading,load,PF,voltage and KWH including connected necessary items for functioning complete all as specified and directed. |
| 278 | M&L for applying two coats of oil bound distember on wall or concrete over a coat of primer on prepared surfaces including,rubbing with sand paper after complete removal of existing treatment complete |
| 279 | Supply & Fixing of SITC of LED Patient bed head light with Up-Down twin side glow 20W+20W batten type wall mounted luminaire. CCT 6500K (CW) on down side & 3000K (WW) on up side & total system lumen not less than 2000Lm on each side. Color Rendering Index (CRI) ≥80, long life of 35000hrs of operation, Fully diffused optics with eye comfort technology, Inbuilt electronic driver, PF >0.90 and THD <20% with operating voltage 160-270V AC, 50Hz. Inbuilt surge protection minimum 2.5 KV, complete in all specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail