Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #56002186

Tender For Repair To Roof, Ppgl Sheets, Roof Treatment, Flooring, Hard Standing And Misc B/R Related Works In Aop Area Including Hangers Of Army Avn Sqn Under Ge Nasik Road C

Issued by Statutory Bodies & Commissions/Committees · Nasik, Maharashtra
Tender Value
84 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
2 days left
EMD
1.51 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nasik → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair To Roof, Ppgl Sheets, Roof Treatment, Flooring, Hard Standing And Misc B/R Related Works In Aop Area Including Hangers Of Army Avn Sqn Under Ge Nasik Road C

BOQ

Name of Work:- REPAIR TO ROOF, PPGL SHEETS, ROOF TREATMENT, FLOORING, HARD STANDING AND MISC B/R RELATED WORKS IN AOP AREA INCLUDING HANGERS OF ARMY AVN SQN UNDER GE NASIK ROAD C
Sl. No. Item Description
1M&L for Applying two coats of distemper oil emulsion white or tinted on walls over a coat of primer, including preparation of surfaces by washing, rubbing down, stopping and complete removal of old distempered surface etc complete all as specified and directed.
2M&L for Applying 3mm thick wall care putty on wall complete all as specified and directed.
3M&L for Applying one coat of distemper oil emulsion white or tinted on walls including preparation of old surfaces by washing, rubbing down and stopping of distempered and painted surface complete all as specified and directed.
4M&L for Applying one coat of distemper oil emulsion white or tinted on ceilings , including preparation of old surfaces by washing, rubbing down and stopping of distempered and painted surface, etc. complete all as specified and directed. Note for Srl item No. 1 to 4 : Work to be executed upto 15 mtr height or any situation.
5Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs any thickness, including cover fillets complete all as specified.
6S&F Hollow PVC Wall Lining consisting of 5 to 7 mm thick Plain wood grain printed PVC sheet inclusive of solvent cement and fixing with 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall as per specifications. taking down carefully (copper/aluminium) point wiring/ switch board in wall and ceiling and refixing the same in any position, complete all as specified and directed.
7Supply and fixing position suspended false ceiling system using T-grid suspended ceiling grid system . The size of grid shall be 600x600mm with GI frame work main runner 38x24x3600mm, cross tee 25x24x600mm/25x24x1200mm and wall angle 24x24x2540mm (thickness of the materail of 0.30mm) using 9mm thick ceiling panel laminated with PVC film on front face and foil back available in the drop texture as per IS-2095, part-I 1996, fixed in the grid of T-grid suspended ceiling grid system duly susupended by 4mm dia GI bar hanged from the purlins of the roof with butter fly clips complete all as specified and directed by Engr-in-Charg. Note for Srl item No. 6 & 7 : Work to be executed upto 15 mtr height or any situation.
8Dismantling AC corrugated or semi corrugated sheets in wall cladding complete all as specified and directed.
9Dismantling Pre-painted galvalume aluminum, CGI corrugated and plain sheets in wall cladding or roof coverings including ridges and make good of aluminium earthing strips after fixing of sheets (at any height / any location) complete all as specified and directed.
10Dismantling fibre glass corrugated or semi corrugated sheets in wall cladding complete all as specified and directed. Note : Work to be executed upto 15 mtr height or any situation.
11Refixing old any thickness pre-painted galvalume aluminum, CGI corrugated sheet with two corrugations side lap, fixed with coach screws and washers, in roofs, after repair of roof (at any height / any location ) etc.complete all as directed.
12S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws (at any height / any location ) complete all as specified and directed.
13S&F for 2 mm fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with coach screw and washer in roof, wall (at any height / any location ) complete all as specified and directed.
14S&F for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, ridges fixed with self tapping screws as specified. Note : Work to be executed upto 15 mtr height or any situation.
15M&L PCC (1:3:6) type C-1 using 20 mm graded stone aggregates as in coping on top of wall and the like including weathering, slightly rounded or chamfered angles and throating including use of necessary form work and finishing exposed surfaces of concrete even and smooth without using extra cement complete all as specified and directed.
16S&F in repairs 0.63mm thick Plain, galvanised, mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 (at any height / any location) complete all as specified and directed.
17S&F for bands, straps, supports or stays for rainwater, ventilating pipes, valley guters and wind tie for ridge including bolts, bending, welding, riveting to supporting if required: hooks (stay), heavy, similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
18Dismantling PVC (SWR) pipe any size and in any position complete all as directed by Engr-in-Charge.
19S&F for 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls. Note : Work to be executed upto 15 mtr height or any situation.
20S&F for 110mm PVC (SWR) bends any radius all as directed
21S&F for 110mm PVC (SWR) branch piece, single (single Y) equal or unequal all as directed
22Excavation in post holes (or similar holes) each in n exc 0.5 cum getting out and removing surplus soil to a distance in n exc 50 m and making good surface in soft/loose soil complete all as specified and as directed.
23Dismantling wrought iron or mild steel work of any description and in any position complete all as directed by Engr-in-Charge.
24S & F framed work as in grill, doors or gates of angle or other section with gusset plates, braces, etc. complete, drilled for fixing of steel sheeting or other coverings,doors,etc to be prepared for hanging or sliding with and inlcluding either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe Grade 410W(Gde E-250) complete as specified and directed.
25S&F for steel work as in tabular trusses/supproting pipes etc complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240 all as directed
26S&F for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment all as directed
27M&L for preparing new steel surfaces of any description over 10 cm in width or girth and applying two coats sythetic enamel paint with one coat of red oxide as directed by Engr-in-charge inclnecessary scaffolding and other safety arrangement to work at any height at site if required all as directed
28Taking down anti bird netting of any description at any position and any height complete all as specified and directed by Engr-in-Charge.
29M&L for bird proofing net made of Anti Bird net in UV black colour made of material Polyolfin all weather proof Co-polymer of machine knotting using CNC machine with DSLS technology for anti silp knotting, heat setting should be steam saet for greater dimensional stability and knot firmness and diameter of the twine is 1mm and size of mesh 25x25mm (+2) and should achive twine breaking strength of 16 Kgf (160N) minimum and MBS (Knot breaking strength) 12 Kgf (120N) and KBS (Knot breaking strength) 22 Kgf (220N) minimum fixed complete all as per manufacturers instructions complete on trusses. Bird proofing arrangement shall fixed/tied to truss members (at any height / any location ) with nylon wire as per manufactures instructions & as per direction of Engr-in-Charge. Make : Leo Technova India or techno commercial equaivalent approved make. Note : Work to be executed upto 15 mtr height or any situation.
30Taking down chowkhats or frame with shutter (without taking off shutters from the frames) n.exc 1.50 sqm each removing from the site complete all as specified and directed.
31Taking down shutter of any description exc 1 sqm but n exc 2 sqm from chowkhat and removing to or from store as required complete all as specified.
32Taking down shutter of any description exc 2 sqm from chowkhat and removing to or from store as required complete all as specified.
33Taking down chowkhats or frame n.exc 1.50 sqm each removing from the site complete all as specified and directed.
34Taking down chowkhats or frame with shutter (without taking off shutters from the frames) exc 1.50 sqm but n. exc 4 sqm each removing from site complete all as specified and directed.
35S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
36S&F for 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides particle board core including two coat of synthetic enamal paint over one coat of pink primer all as specified and directed by Engr-in-charge.
37S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube etc all as specified and as directed.
38S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement,suppling & fixing in the frame at site as per specification & drawing all as specified and as directed.
39S&F mild steel flat iron for hold fasts, wall ties, hooks for hanging fans, plain angle, clamps for pipe and similar small articles conforming to Fe-290 Gde -E-165 complete all as specified and directed.
40M&L PCC 1:3:6 type C-1(using 20mm graded stone aggregate) as in bed blocks for grouting hold fasts, coping or similar work including necessary form work complete all as specified and directed.
41S&F 75mm butt hinges, medium weight, cold rolled mild steel all as directed.
42S&F 100mm butt hinges, medium weight, cold rolled mild steel all as directed.
43S&F aluminum anodised barrel tower bolts extruded section of size 150mm long (ISI Marked) in repairs complete all as specified and directed .
44S&F 150mm long extruded aluminum alloy (fabricated type) handles anodised ISI marked complete all as specified and directed.
45S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
46S&F for floor door stopper of brass 140mm body and tongue complete all as specified and directed.
47M&L preparing surfaces of wood an wood based surfaces of any description not otherwise described over 10cm width or girth and applying of two coats synthetic enamelled paint over a coat of pink primer complete all as specified and directed.
48Demolition of Brick work or stone/boulder masonry, built in CM including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles all as specified and as directed.
49M&L brick masonry with fly ash bricks, straight or curved or plain exc 6m mean radius built in cement mortar 1:6 all as specified and as directed.
50M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate in foundation mass concrete and filling complete all as specified and as directed.
51Material and labour for PCC 1:2:4, type B2, including necessary formwork using 40mm graded crushed stone aggregate, as in surface channels and drains etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engr-in-Charge
52Demolition of reinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) all as specified and as directed.
53M&L for pre-cast RCC 1:2:4 type B1 using 20mm graded stone aggregates as in cover slab/MH cover complete all as specified and directed.
54M&L for TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealled) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
55M&L for TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
56Moorum / Red Bajari filling in floor or pavings, laid in layers n.exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
57M & L broken stone hard core of gauge n. exc. 63 mm deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rolled / rammed to a true surfaces complete all as specified and as directed.
58Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level)all as directed.
59M & L for 100 mm thick PCC 1:4:8 Type D-2(using 40mm graded aggregate) as in sub base over rammed earth complete all as specified and as directed.
60Dismantling of stone slabs & tiles of any decsription or thickness in floors, aprons, steps, laid, bedded & pointed in any mortar all as specified and directed.
61M & L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper mbedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping complete all as specified and directed
62M & L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper mbedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping complete all as specified and directed
63M & L for Chequered cement concrete tiles with grey cement and pigment 30cmx30cmx25mm thick, with rubber moulded glossy finished surface, laid in floors over and including 15mm thick screed bed or beddingin CM 1:6 pointed in neat cement slurry in floors complete all as specified and as directed.
64M & L for 50 mm thick PCC 1:3:6 Type C-2(using 40mm graded aggregate) as in sub base over rammed earth complete all as specified and as directed.
65M & L for 100mm thick nominal mix concrete type A-1, M-20 (20mm graded aggregate) laying in floor with screed vibrator including finishing cement concrete surface even and smooth with brooming of top and cutting of construction/dummy joints10mm deep and 10 mm wide by early entry saw cut using diamond bi cutter of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil , vegetation and the debris concrete surface and filling with sealing compound Grade ‘B’complete all as specified and as directed.
66Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debris out of MOD land and rubbish off the premises.
67M & L for 40mm thick PCC 1:2:4,type B-0, (using 12.5 mm graded aggregate) as in subases/levelling course to flooring complete all as specified and directed.
68M&L Non skid ceramic tiles coloured 7 to 8mm thick (square/rectangular ) area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
69M & L for coloured glazed ceramic tile 7-8 mm thick as in dado/wall tiling over and including 10 mm thick backing coat in CM 1:4 in any position /shape/pattern complete all as specified and as directed.
70M & L for 8-10 mm thick double charged vitrified tiles as in flooring,laid in any shape/pattern over and including 15 mm thick screed in CM 1:6 as in floors.
71M & L for 10 mm thick 0.6 x 1.2 m double charged vitrified tiles as in flooring, laid in any pattern over and including 15 mm thick screed in CM 1:6 as in floors complete all as specified and as directed.
72Taking up or down 15mm/20mm tubes galvanized iron and connections & removing/ shifting to site/store incl cleaning for relaying/refixing where directed.
73Refixing 15mm galvanized iron tubes as directed incl renewal of threading/tread cutting at ends of GI pipes fixed to walls or laid in floor and jointing incl S/F new fitting such as socket, bends, elbows, union etc all as specified and directed of size all as specified and as directed.
74S&F for 15mm tubes medium grade galvanized with all fitting fixed to walls, ceiling and laid in floor (Concealed)
75Refixing old steel tubing and connections 20mm bore in new or old position in Walls, ceiling, floors, etc (Concealed ).
7620mm bore galvanised steel water tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors (Concealed ).
77Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
78Disconnecting existing tanks exc 250 n exc 500, ltrs setting aside (or lowering if required) cleaning and removing all scale, dirt etc from the mouth of circulating pipes and hoisting if required, reconnecting and re-fixing in position all as specified and as directed.Note: Work is to be executed at any height and situation.
79S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) double layer hoisted and fixed in position of capacity 1000 litres including 20/25mm dia PTMT float valve and dismantling water tanks and removing to store complete set all as specified and directed.
80S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) double layer hoisted and fixed in position of capacity 500 litres including 20/25mm dia PTMT float valve and dismantling water tanks and removing to store complete all as specified and directed.
81S&F Vitreous China (Squat pattern) size 630mm white, (excluding flushing cistern and flush pipe) with integral foot rest and P/S trap complete including lime concrete bedding including connection to drain (or outgoing pipe), and to flushing pipe & antisyphonage pipe etc complete all as specified and as directed.
82S&F in repairs vitreous chinaware wash hand basin white, flat back of size 550x400 mm excluding tap but including brackets fixing to wall and two Nos 10mm dia 100mm long nut and bolt over brackets including 32mm bore PVC waste pipe and CP waste coupling complete and fixed in repair complete all as specified and as directed.
83Supply and fixing plastic sheet cover closed pattern with flat bottom and cover including chromium plated hinge device complete all as specified and directed by Engr-in-Charge.
84S&F in repairs PVC valveless, syphonic action type 10 ltr capacity flushing cistern, low level, white or coloured, with inlet, ball valve,float and handle including brackets complete all as specified and as directed.
85Supply and fixing in repairs 15mm dia Bib Taps, CP fancy type with crutch or butter fly handle screwed down pipe or for screwed iron pipe complete all as specified and directed
86Supply and fixing in repairs 15mm dia CP stop cock concealed type cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for union all as specified and as directed.
87Supply and fixing in repairs pillar taps, 15mm bore cast copper alloy with capstern head, chromium plated screwed down high pressure with or without lettered hot or cold complete all as specified and directed by Engr-in-Charge.
88Supply and fixing in repairs 15mm dia PVC connection with brass check nut of length 450mm complete all as specified and directed by Engr-in-Charge.
89S & F in repairs 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and as directed.
90S&F Health facuet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25mm long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and directed by Engr-in-Charge.
91S&F in repair PVC waste pipe 32 mm dia including WHB coupling CP 32mm complete all as specified and directed
92S&F in repairs Viterous China urinal, flat back of size 465x355x265mm white (minimum) with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal plugs with and including 60mm long brass screws, pointing around urinal back in cement including 32mm bore PVC waste pipe fixed in repair complete all as specified
93Taking down carefully existing bituminous membrane/tarfelt treatment any description and cleaning and making good damaged surface of roof, parapet, facia etc in cement mortar 1:3/PCC 1:2:4 including complete removal of swollen plaster and concrete wherever directed and removing rubbish out of defence land all as directed by Engr-in-charge
94Demolition of concrete (unreinforced) of any description and in any position not otherwise secifically provided for all as directed.
95Providing cement concrete type B0 1:2:4 (12.5mm graded aggregate) in roof kerbs or mud stops,ridge, padding, rounded or chamfered on edges all as directed.
96M and L for rendering 15mm thick in CM 1:4 with intergral waterproofing compound (200 ml per bag of cement used) on roof surfaces, parapets, facias all as specified and as directed.Note: waterproofing compound shall be measured and paid separately.
97Supplying only integral water proofing compound ISI marked all as specified and as directed.
98M and L for applying evenly a coat of hot blown bitumen grade 85/25 over roof, facia, parapet surfaces at the rate 1.20 kg per sqm for fixing APP membrane etc including cleaning surfaces complete all as specified and as directed.Note: Make shall be same as of APP membrane.
99M & L for Waterproofing treatment on roof including flashing and junctions of parapet, kerb, wall etc as under :- (a) Laying a layer of APP based polymeric membrane, 3 mm thick(minimum), weighing not less than 3.60 kg/Sqm prefabricated five layer waterproofing membrane reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over compatible primer at 0.40 litre/Sqm of density at 25 degree Centigrade 0.87-0.89 Kg /Litre and viscosity 70-160 cps or cold sticker, application of APP modified membrance shall be by torch application. The overlaps shall be minimum 150mm on the transverse direction and 100 mm on the longitudinal direction. (b) APP membrane, Primer and bitumastic aluminium paint and bitumen shall be of same brand.(c) For vertical surfaces of parapet, wall etc APP membrane shall be tucked into groove and sealed with silicon sealant (full width/depth of groove) i.e. \\"Dowsil 789 weatherproof silicon sealant\\" using gun.(d) Bitumen and aluminium paint shall be paid separately.Note: Work is to be executed at any height and situation.
100M & L for applying two coats of solar reflective bitumastic aluminium paint at the rate 0.15 kg per sqm per two coats over exposed APP membrance surfaces (old/new) including cleaning of surfaces to the entire satisfaction complete all as specified and as directed..Make: Make shall be same as of APP membrane.
101S&F 5.5 mm thick toughened glass as in hinged door, partitions, automatic door & similar work including shaping, drilling holes required and provn of handle complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56002186
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 84 Lakhs
LAST DATE 13-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Roof, Ppgl Sheets, Roof Treatment, Flooring, Hard Standing And Misc B/R Related Works In Aop Area Including Hangers Of Army Avn Sqn Under Ge Nasik Road C
Basic Detail
Tender No 83758/E8
Bidding Type Tender
Location
City Nasik
State Maharashtra
Key Dates
Publish Date 15 Jun 2026
Submission Date 13 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 84 Lakhs
Tender Fee 1000
EMD 1.51 Lakhs
Exemption Available
Document List
042723e0-010e-4d15-ba65-c536906e732e.html
83758TENDERDOCSALL.pdf
BOQ_864718.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

042723e0-010e-4d15-ba65-c536906e732e.html

pdf

83758TENDERDOCSALL.pdf

xls

BOQ_864718.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail