| 1 | Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed. |
| 2 | M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed. |
| 3 | M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 4 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 5 | M&L Random rubble masonry walling well bonded, bedded, solidly hearted, uncoursed built in CM 1:6.Complete all as specified and directed. |
| 6 | M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 7 | S&F pre- painted galvalume aluminum zinc corrugated steel based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping serews as specified and directed by Engr - in - Charge. |
| 8 | Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and directed. |
| 9 | M&L for Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 10 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 11 | Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out making good the disturbed surface if required in soft/ loose soil complete all as specified and directed. |
| 12 | M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete all as specified and directed. |
| 13 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for. Complete all as specified & directed. |
| 14 | M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete,drilled for fixing of steel sheeting or other covering. Doors,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening anf fixing complete all as specified and directed. |
| 15 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 16 | M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc all as specified and directed by Engr - in - Charge. |
| 17 | M&L preparation of new steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge |
| 18 | S&F machine pressed precast concrete interlocking paver block any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement & pigment complete all as specified & directed. |
| 19 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 20 | M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed. |
| 21 | M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 22 | M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in path/ hard standing surface finished even and fair complete all as specified and directed. |
| 23 | M&L 75 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in sub base,floor , plinth protection etc and finishing cement concrete even and fair specified and directed by Engr - in - Charge. |
| 24 | M&L Excavating over areas, n exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and directed. |
| 25 | M&L for 10 mm thick heavy duty exterior designer tiles of size 300 mm x 300 mm as in floor set, jointed in neat cement slurry and pointed with grey cement and pigment complete all as specified and directed. |
| 26 | M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed. |
| 27 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed. |
| 28 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 29 | M & L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed. |
| 30 | M&L for Pre painted Chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor complete all as specified and directed. |
| 31 | S&F in repairs 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed |
| 32 | S&F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 33 | M&L for finishing cement concrete even and smooth using extra cement complete all as specified and directed. |
| 34 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 250 ltr n.exc 500 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using bleaching powder @ 0.25 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 35 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 500 ltr n.exc 1000 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using with bleaching powder @ 0.50 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 36 | S&F in repairs ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 37 | S&F in repairs ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. |
| 38 | Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 39 | M&L for preparing new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed |
| 40 | M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed. |
| 41 | Dismantling posts or sturts (wood,steel or RCC) any section incl taking out embedded portion and making good disturbed ground etc all as specified and directed. |
| 42 | Dismantling fencing wire mesh any type etc all as specified and directed. |
| 43 | S&F Angle iron posts and rails,drilled and struts in fencing including cutting tops to shape as directed, driiling holes, notching for wire, etc, flat iron fillets (for secruing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165. |
| 44 | Mild Screw bolts (Machine made) with hexagonal or square head at one ends and to fitted with washers and one hexagonal or square n.exc 15cm long, dia of neck 11 to 15mm all as specified and directed by Engr-in-Charge. |
| 45 | Fixing only chain link fencing including line wire, any mesh, any size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 46 | Supply only PVC coated chain link of 3.16mm dia mild steel galvanised fencing of mesh size 75 mmx 75mm as per IS : 2721-2003 weight n exc 4.00 kg per sqm complete all as specified and directed by Engr - in - Charge. |
| 47 | S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified & directed. |
| 48 | M&L for writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 cm high etc complete all as specified and as directed by Engineer-in-Charge. (Note : Rates to be deemed fit for all security measures while working in heights more than 6m from GL). |
| 49 | M&L preparation of old painted surfaces and applying one coat of cement based on walls complete all as directed by Engineer-in-Charge |
| 50 | M & L for two coats of cement based paint over a coat of primer on new plastered surface of walls including preparation of surface complete all as specified and directed by Engr-in-Charge/GE. |
| 51 | M&L applying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly plastered wall surfaces/ old decorated wall surfaces, in case of old decorated wall surfaces includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed by Engr-in-Charge/GE. |
| 52 | S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. |
| 53 | S & F in repairs cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. |
| 54 | S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. |
| 55 | S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. |
| 56 | S & F in repairs cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. |
| 57 | S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. |
| 58 | Supply & Lay , testing and commissioning in repairs XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas complete |
| 59 | Repairing / Servicing the Air break isolating switch HT 33 KV/11 KV 200/400 Amps by replacing the defective major spares including provn of minor bolts nuts etc all as specified. Note :- Major spare will be measured & paid seperately under relevant item of Sch'A' item No. 27 |
| 60 | Supply only 33 KV/11 Airbreak switch spares all as directed.(a) Male contact/moving Contact Blade |
| 61 | (b) All as per item no 60 but for Female contact/Fix Contact Jaw |
| 62 | (c) All as per item no 60 but for Rotating contactor pipe 200A/400 A |
| 63 | (d) All as per item no 60 but for MS jumper carrier |
| 64 | (e) All as per item no 60 but for Back Connector plate |
| 65 | S & F in repairs lighting arrestor Zinc oxide gap less type , station class suitable for 11 KV / 65 KA complete with all fittings all as specified and directed .(Make : M/s Crompton Greaves / M/s Lamco / M/s Elpro / M/s Oblum) |
| 66 | M & L for removing vegitation, grass, scrubs and bushes growing in Sub station yard along with fancing by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. |
| 67 | S & F in repairs insulating rubber mat ISI marked of size 1 m x 2 m x19mm suitable for 11 KV at 33 KV MRS |
| 68 | Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in soft/ loose soil all as specified and directed. |
| 69 | Excavating in trenches not exceeding 1.5 meter wide and exceeding 1.5 meter and not exceeding 3meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in soft/loose soil all as specified and directed. |
| 70 | Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata |
| 71 | Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5M above the starting point |
| 72 | Supply/ Lay dry river sand /m -sand in trenches for cable protection all as directed.Note : Punned thickness only will be measured & Paid |
| 73 | M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard for laying all as directed and specified. |
| 74 | M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation. |
| 75 | M & L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate including use and waste of form work for pole filling/ any description all as directed. |
| 76 | M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including use and waste of form work for pole filling/ any description all as directed. |
| 77 | S & F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of the following sizes as in repairs :-(a) 80 mm dia |
| 78 | (b) All as per item no 77 but for 100 mm dia |
| 79 | M & L for Prestressed concrete pole, 9.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complete all as specified and directed. |
| 80 | S & F in repairs Galvanaised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces incl taking down / dismantling the old items complete all as directed. |
| 81 | S & F in repairs Disc type porcelain vitreous, brown or white insulator suitable for 11 KV HT working Pressure of size 145 mm height, 255 mm dia , including. one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete all as directed. |
| 82 | S & F in repairs Pin type porcelain vitreous,brown of white insulator suitable for 11KV HT of working pressure of size 150mm height, 150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete all as directed. |
| 83 | Taking down carefully the existing 11KV/433 V distribution transformer of capacity 63 KVA to 250 KVA by disconnecting HT overhead connection/underground cables and earth strips etc. from any substation / locations using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer; transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed by Engr-in-charge. Note : All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted. |
| 84 | Taking down carefully the existing 11KV/433 V distribution transformer of capacity 315KVA to 630 KVA by disconnecting HT overhead connection/underground cables and earth strips etc. from any substation / locations using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer; transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed by Engr-in-charge. Note : All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted. |
| 85 | Taking down carefully the existing 33KV/433 V distribution transformer of capacity 25 KVA by disconnecting HT 33 KV overhead connection/underground cables and earth strips etc. from MRS using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop/ or repair at site/inside store yard and unloading carefully. Reloading the tranformer after repairs and testing of transformer; transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed by Engr-in-charge. Note : All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted. |
| 86 | M & L for repairs toTransformer step down 11KV/0.433 KV any type of capacity 63 KVA to 250 KVA, after dismantling the transformer body carefully, opening the top cover of Transformer for inspection /repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, renewal/replacement of u/s rubber bushes and washers , replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, Painting of complete transformer body from outside and inside by weather proof type using spray gun, Marking of MES/SM Number etc, replacement of conservator tank glass, re-intalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed by Engr-in-Charge. Note :- Winding wire including labour for making of coils and LT/HT bushes will be measured & paid seperately. |
| 87 | All as per Srl item No 86 above but of capacity 11 KV/0.433 KV, 315 KVA to 630 KVA complete all as directed. |
| 88 | All as per Srl item No 86 above but of capacity 33 KV/0.433 KV, 25 KVA complete all as directed. |
| 89 | Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration in distribution 11 KV transformer /Distribution transformer 63 to 650 KVA or for replacement complete including removing of old unservicable transformer oil all as specified and directed. |
| 90 | M & L for conducting oil filtration by stream line / Vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for min for distribution transformer incl routine testing after filtration for any capacity of transformers/CT/PT units all as directed. (Note : The contractor shall change the filter assy before starting the filtration of power/ distribution transformer of any capacity in presence of Engr In charge) |
| 91 | Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 63KVA to 250 KVA complete. |
| 92 | Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 315KVA to 630 KVA complete. |
| 93 | All as per item No 91 above but LT side. |
| 94 | All as per item No 92 above but LT side. |
| 95 | Material and labour for repalcement of gasket for complete transformer all as specified and directed |
| 96 | Material and labour for repalcement of silica gel breather for transformer 1.6 MVA complete all as specified and directed |
| 97 | Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 63 KVA to 250 KVA. |
| 98 | Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 315 KVA to 630 KVA. |
| 99 | All as per item 97& 98 above but LT side. |
| 100 | Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 63 KVA to 250 KVA transformer. |
| 101 | Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA to 650 KVA transformer. |
| 102 | M & L for painting using spray painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 63 KVA to 650 KVA (Indoor/outdoor type). |
| 103 | M & L for painting using spray painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 1.6 MVA complete |
| 104 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below normal ground level, connecting to the Galvanised iron earth lead 32x6mm size, by means of bolts, nuts, check nuts and washers of galvanised iron and 32x6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4kg/Sqm) and frame of angle iron 25x25x3 mm with lugs-02 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom 1.5 meter long placed on top edge of earth plate common salt and charcoal filling, test point with fixing arrangements, funnel wire mesh and earth work in hard/dence soil returning filling in and removal of surplus soil to a distance not exceeding 50 m, all as per electrical plate No 5 of SSR-2010 Part-I and connecting to earth test point all as specified and directed. |
| 105 | M&L for replacement off load tap changer for distribution transformer of any make and capacity from 63-650 KVA |
| 106 | M&L for super enamelled copper conductor wire of suitable gauge and size including making suitable coil bobbins as per existing size and shape with proper insulating materials, spacers, warnishing as per required grade and insulatin and assembling on core, heating the same in oven as per standard procedure at appropriate temerature to obtained desired insulatin level for the power/ distribution transformer of any capacity / any make complete all as directed. |
| 107 | Painting of two pole stucture consistig of 2 Nos PCC pole 11 M height, 1 no GOS, 1 set support insulators with channels, with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code to the metal structure and cement paint to the PCC structures all as specified and as directed |
| 108 | Painting of two pole stucture consistig of 2 Nos (Metal Strucure) 11 M height, 1 no GOS, 1 set support insulators with channels, with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code to the metal structure and cement paint to the PCC structures all as specified and as directed |
| 109 | Painting of four pole stucture consisting of 4 Nos pole(metal structure) 11 M height, 3 no GOS, 1 set Fuse with channels,1Bus bars 1 No LA etc with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code all as specified and as directed |
| 110 | Painting of four pole stucture consistig of 4 Nos pole(PCC) 11 M height, 3 no GOS, 1 set Fuse with channels,1Bus bars 1 No LA etc with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code all as specified and as directed |
| 111 | Supply & Fixing in replacement precast PCC cable route indicator duly marked and painted for HT /LT cable of size 80 x 25 x 7.5 CM with suitable size of base complete all as specified and as directed. |
| 112 | Supplying & laying of precast concrete cable cover, class LV, type 1 peak type size 250mmx150mmx40mm complete all as specified and directed.. |
| 113 | S & F in repair horn gap fuse 11 kv 200 Amps horizontal/vertical type for outdoor use including all connected accessorises complete all as specified and as directed |
| 114 | Supply and install HT 11 KV 3 phase 50 cycles out door type air break switch suitable for horiandal/Vertical mounting fixed type complete operating handle and all clamps,nuts,bolts etc of rating upto 200 Amp all as specified and as directed |
| 115 | M&L in repairs danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete |
| 116 | Supply and fixing of fuse wire tinned copper of different capacity as per ground requirement complete all as specified and directed.. |
| 117 | M&L for cable fault locator vehicle mounted to locate fault at any type of location with one fault locate at a time complete all as specified and directed by Engr-in-Charge |
| 118 | M&L for in repairs aluminium conductor steel reinforced complete all as specified and directed to be used as jumpers |
| 119 | M & L for Cutting and trimming of tree branches 5 mtr all around of any size which is coming over the two/four pole structure of 11 KV line by using required tools and plants incl removing trimmed tree branches. (Note : Each cleaning will be measured and paid separetely) |
| 120 | S & F in repair horn gap fuse 33 kv (Polymer) 200 Amps horizontal/vertical type for outdoor use including all connected accessorises complete all as specified and as directed |
| 121 | S&F in repair 33 KV disc insulator polymer type with hardware fittings complete all as specfied and directed |
| 122 | S&F in repairs power aluminium bolted type connectors to be fixed on jumpers/aluminum conductors/AB conductors of any size complete all as specified and directed |
| 123 | S&F in repairs of AB conductor of size 95 Sqmm with colour code (RYB) as required on ground for MRS structure complete all as specified and directed |
| 124 | S&F in repairs of 33 KV post insulators complete all as specfied and directed |
| 125 | S&F in repairs of 11 KV post insualtors complete all as specified and directed |
| 126 | Boring of holes horizontally for laying of 80mm dia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
| 127 | M&L for attending day to day breakdown complaints of any nature in high tension line after receiving complaint from complaint cell/ JE concerened and rectifying the same as soon as possibble complete all as specified and directed. |
| 128 | Supply and fixing FRP fencing made up with using FRP rod 12 mm dia, channel size 50x24x4 mm box section 50x25 mm I Section 38x15x3 mm and square box section 50x50mm in post embedded in plain cement concrete (1:4:8) type D2 using 20 mm graded stone aggrerate (45x45x45cm) including necessary excavation and earthwork at 1.25 m C/C with height of fencing 2 m from GL including entracne gate of size 1mx2m of same material MS aldrop bolt 300mm long , 150 mm size pressed steel handles and 2 Nos tower bolts MS hinges as required etc complete all as specified and directed Make : Sintex/ Sanlec or equivalent as approved by GENote :- Verticle posts and rail section shall be manufactured of fibre glass reinforcement min 45% and formulation of polystrbased thermoset resigns. |
| 129 | M& L for Brickwork with straight or curved on plan with Fly ash bricks, exc 6 m mean radius built in CM 1:6 complete all as specified and as directed. |
| 130 | M & L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement water proofing compound complete all as specified and as directed |
| 131 | M&L for plain Cement Concrete 1:3:6, Type C-2 of grade using 40mm graded stone aggregate in foundations, filling and mass concrete, etc. for embedding fencing posts, complete all as specified and as directed. |
| 132 | Taking out old UNSV XLPE/PVC insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor from trenches, from poles/walls etc cross sectional area for following sizes complete, all as specified and directed :-(Excavation/Earth wk will be measured and paid seperately) (a) 10 Sqmm to 16 sqmm 4 / 2 Core |
| 133 | (b) All as per item no 132 but for 25 to 50 Sqmm 3.5 Core/4 core. |
| 134 | (c) All as per item no 132 but for 50 to 185 Sqmm 3.5 Core/4 core. |
| 135 | Relaying of serviceable U/G cable retrived from site of size 10 to 16 sqmm 2/4 core ( Cable protection pipe /sand brick,jointing kit,cable lugs etc will be measured and paid seperately) |
| 136 | Relaying of serviceable U/G cable retrived from site of size 25 to 35 sqmm 2/3.5/4 core ( Cable protection pipe /sand brick,jointing kit, cable lugs,etc will be measured and paid seperately) |
| 137 | Relaying of serviceable U/G cable retrived from site of size 50 to 185 sqmm 2/3.5/4 core ( Cable protection pipe /sand brick,jointing kit, cable lugs etc will be measured and paid seperately) Please Enable Macros to View BoQ information |