| 1 | Supply, installation, tesing and commissioning of Split AC 2.0 TR capacity, inverter type, Hot & Cold air conditioner electric driven, single phase, energy efficient , ISEER rating should be in the highest bracket of the BEE's star rating policy, charged with Eco friendly Refrigerent R410/R32 and all connected accessories including fixing of copper pipe & wire from indoor unit to outdoor unit, making of suitable size of hole in any type of masoury wall and making good. Fixing of PVC drain pipe from indoor unit to plinth protection of building, outdoor unit wall mounted stand/ floor mounted stand, flexible PVC casing pipe minimum 40mm dia covered on all exposed copper insulated pipe line and PVC wire complete all as specified and directed. (Note : Cost of copper pipe, drain pipe paid separately under respective items of this schedule) |
| 2 | S&F polycarbonate Modular AC box with Single pole MCB 25 Amps,with heavy duty ISI Marked 3 Pin Plug Top complete all as specified and directed. |
| 3 | Supply and fix Copper pipe of 1\4'' size, thickness 21 SWG, with nitrile rubber insulation complete all as specified and directed. |
| 4 | Supply and fix Copper pipe of 1\2'' size. Thickness 19 SWG, with nitrile rubber insulation complete all as specified and directed. |
| 5 | M&L for sub main wiring with 2 runs of 4.0 sqmm single core, PVC insulated & unsheathed (FRLSH) cable 1100 Volts grade with multi stranded, copper conductor drawn through casing and caping as per ISS and one run of 4.0 sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of cable and one run of earth conductor shall be measured as one unit) |
| 6 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA |
| 7 | S&F of 4mm thick ACP (Alum composite panel) cladding of approved quality and colours as approved by GE, Fixing in MS frame at any height and incl MS Frame of size not exc 0.36 Sqm (used in MS rectangular tubes of size 50.8mmx25.4mmx2.9mm or square tubes 38mmx38mmx2.9mm are used in frame) and filling the joints with all weather silicon sealant incl all mouldings, cutting etc complete all as specified and as directed. |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises complete all as specified and directed. |
| 9 | M&L for Non - skid coloued Ceramic tiles, light shade, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and incl 15mm thick screed bed Cm 1:6, complete all as specified and directed. |
| 10 | M&L for Glazed ceramic tiles in vertical surface as in dado 600X 300X 7 to 8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 11 | M&L for Vitrified Ceramic Coloured tiles 8 to 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36sqm in floors over and incl 15mm thick screed beeding layer in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles complete all as specified. |
| 12 | M&L for vitrified coloued Ceramic tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36sqm,on vertical surfaces as in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over 10mm thick rendering in Cm 1:4, complete all as specified and directed. |
| 13 | Taking down shutter and refixing in same opening after easing and adjusting, area of shutter exc 1 sqm but not exc 2 sqm each complete all as specified. |
| 14 | S&F 15mm dia bore water tubing, medium grade, galvanised with all fitting laid in trenches/wall including taking down old pipe complete all as specified and directed. |
| 15 | S&F in repairs 15 MM brass CP Mixer for mixing hot & Cold water screwed down for iron pipe complete all as specified and directed. |
| 16 | S&F in repairs Vitreous China wash down water closet pan ( pedestal pattern) , white, complete all as specified and directed. |
| 17 | S&F in repair Plastic water closet seat, back, closed pattern with flat bottom , and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 18 | S&F in repair 10 ltrs PVC valveless, syphonic ac-tion type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 19 | S&F PVC connection 15mm sizes with PTMT nuts of length 450 mm complete all as specified and directed. |
| 20 | S&F in repair vitreous china wash basin, white , flat back , size 550 x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed. |
| 21 | Supply only waste fitting 32mm dia, CP for WHB with long screwed shunks and nuts complete all as specified and directed |
| 22 | S&F in repair PVC waste pipe 32mm dia 60 cm long suitable for WHB/Sink complete |
| 23 | S&F in repair sheet glass shelf assembly consisting of 5.5mm thk sheet glass shelf 12cm wide with CP bracket guard and railing 60cm long complete all as specified and directed. |
| 24 | S&F in repair 125 mm size Brass chromium plated shower rose suitable for 15 mm bore pipe complete all as specified and directed. |
| 25 | S&F in repairs 15mm dia bib taps fancy type , CP cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or brass ferrule fancy type complete all as specified and directed. |
| 26 | S&F looking mirror size 600x450mm bevelled edges miror of selected quality glass mounted of 6mm thk AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers complete. |
| 27 | S&F in repair 15mm bore angle stop valve chromium plated brass with flange complete all as spd & directed |
| 28 | S&F in repair Toilet paper holder of stainless steel fixed to walls with chromium plated (CP) brass screws complete all as spd & directed |
| 29 | S&F CP health faucet with 1.00mtr long CP flexible pipe as per approved samplecomplete all as spd and directed |
| 30 | S&F in repair CP , tubular towel rail 60cm long fixed with and including CP brass screws and wooden /plastic cleats complete |
| 31 | S&F grating doom 100mm dia of PTMT complete. |
| 32 | S&F in repair viterous china white soap dish fixed to plugs with chromium plated brass screws in position complete all as specified complete. |
| 33 | Taking down cement plaster of any description on brick walls, etc including raking out joints, hacking for key scrubbing down with water complete |
| 34 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed |
| 35 | M&L for two coats of oil emultion distemper on new plaster surfaces of wall over a coat of chalk whitening including prepration of surface complete all as specified and as directed. |
| 36 | Taking down chowkhats or frames with shutters (w/o taking off shutters from the frame) area not exc 1.5 Sqm each complete all as specified and as directed. |
| 37 | Taking down chowkhats or frames with shutters (w/o taking off shutters from the frame) area exc 1.5 Sqm and not exc 4 Sqm each complete all as specified and as directed. |
| 38 | S&F powder coated aluminium frame for windows and ventilators with one or more rebated incl jointing cleats for fixing etc complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 39 | S&F powder coated aluminium frame for windows and ventilators with one or more rebated incl jointing cleats for fixing etc complete all as specified and as directed. Please Enable Macros to View BoQ information |