| 1 | Taking down the defective compressor from the unit and supply and fix new and factory sealed compressor of approved make (including cleaning refrigeration circuit with, cleaning agents flushing through with CO2/N2, complete removal of dirt, oil and carbon etc pressure testing dehydrating, vaccuming, replacment of copper pipe, copper stainer etc) including testing and commissioning of window type AC units 1.5Ton capacity complete all as directed by the Engr-in-Charge. (Note:- Gas will be measured and paid seperately as supply only under relevent item of BOQ) |
| 2 | Supply and fix in repairs air cooled condenser assembly including pipe connections and brazing to the units for 1 Ton/1.5 Ton capacity window type AC complete all as specified and as directed. |
| 3 | Supply and fix in repairs running capacitor suitable for 1 Ton/1.5 Ton/2 Ton capacity window type AC complete all as specified and as directed. (Make: Sarada/Unistar.) |
| 4 | Supply and fix in repairs starting capacitor suitable for 1 Ton/1.5 Ton/2 Ton capacity window type AC complete all as specified and as directed. (Make: Sarada/Unistar.) |
| 5 | Supply and fix in repairs starting relay suitable for 1 Ton/1.5 Ton/2 Ton capacity window type AC complete all as specified and as directed. (Make: Rockwell/Aravind) |
| 6 | Supply and fix in repairs over load protecter suitable for 1 Ton/1.5 Ton/2 Ton capacity window type AC complete all as specified and as directed. (Make: Sriram /Kirloskar) |
| 7 | Supply and fix in repairs fan motor capacitor suitable for 1 Ton/1.5 Ton/2 Ton capacity window type AC complete all as specified and as directed. (Make: Sarada/Unistar) |
| 8 | Supply and fix in repairs wiring kit suitable for 1 Ton/1.5 Ton/2 Ton capacity window type AC complete all as specified and as directed. |
| 9 | Supply and fix in repairs capillary tube assembly suitable for 1 Ton/1.5 Ton/2 Ton capacity window type AC complete all as specified and as directed. |
| 10 | Supply and fix in repairs new selector switch suitable for 1 Ton/1.5 Ton/2.0 Ton capacity window type AC complete all as specified and as directed. |
| 11 | Supply and fix in repairs new fan blade assembly suitable for 1 Ton/1.5 Ton/2.0 Ton capacity window type AC complete all as specified and as directed. |
| 12 | Supply and fix in repairs new fan blower unit suitable for 1 Ton/1.5 Ton/2.0 Ton capacity window type AC complete all as specified and as directed. |
| 13 | Supply and fix in repairs new fan motor suitable for existing 1 Ton/1.5 Ton/2.0 Ton capacity window type AC complete all as specified and as directed. (Make:- AUE/Freeflow/MAGIC) |
| 14 | Supply and fix in repairs new air filter of PVC type suitable for 1 Ton/1.5 Ton/2.0 Ton capacity window type AC complete all as specified and as directed. |
| 15 | Taking down the corrorded AC units of 1Ton/1.5 Ton/2 Ton capacity and carring repairs to sheet metal parts, tinkering the parts and replacing fully corroded sheet metal parts like base plate, fan motor base plate etc. with MS sheet of appropriate gauge as per the existing one including bending to match with the existing size and shape, welding/brazing and assembling inculding repalcing all nuts and bolts, sheet metal screws and painting the complete body with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer after complete removal of existing treatment and preparation of surfaces complete all as specified and as directed. |
| 16 | Taking down the window type AC units of 1Ton/1.5 Ton/2 Ton capacity and scraping out, cleaning and preparing the surface of shell cover and painting with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer after complete removal of existing treatment and preparation of surfaces and refiuxing back to the existing position complete all as specified and as directed. |
| 17 | Taking down the burnt fan motor of 1Ton/1.5 Ton/2 Ton capacity AC unit, rewinding the same with appropriate gauge super enameled copper wire, varnishing, renewal of shaft and bushes stud bolts, terminal wire, reassembling and fixing back to its original position and testing complete all as directed by the Engr-in-Charge. |
| 18 | Supply and fix in repairs new thermostatic switch for window type Acs of any capacity complete all as specified and directed. (Make: Indfoss/Ranutrol) |
| 19 | Taking down the window type AC units of 1.0 Ton/1.5 Ton/2.0 Ton capacity for servicing, inculding dismantling the unit carefully, cleaning of filters, checking circuit of wiring and connections, removal of scale from the parts, chemical cleaning of cooling coil and condenser with appropriate cleaning agent, flushing throughly for proper air flow across the coil to improve the cooling effciency, reassembling the parts and installing the same to original position complete all as specified and as directed. |
| 20 | Supply and fix in repairs oscillation motor assembly with louvers for window type Acs of any capacity complete all as specified and as directed. |
| 21 | Supply and fix in repairs air cooled coling coil for window type Acs of any capacity complete all as specified and as directed. |
| 22 | Supply and fix in repairs operating knob for window type Acs of any capacity complete all as specified and as directed. |
| 23 | Supply and fix in repairs front grill assembly for 1.0 Ton/1.5 Ton/2.0 Ton capacity window AC complete all as specified and as directed. |
| 24 | S&F in repair temperature sensor probes in the main circuit of split Ac complete all as specified and directed |
| 25 | S & F in repairs PCB Card suitable for window type ACs of capacity 1.0/1.5/2.0 Ton complete all as specified and as directed. |
| 26 | S & F in repairs complete outer body of outdoor unit of Split type AC of 1.5/2 Ton capacity in situ as per the existing make and competible model without compressor but including fan motor connecting, necessary copper tubings by brazing/welding, gas charging with R-22 and testing after completion with entire satisfection of Engr-in-Charge complete all as specified and directed. (Note: Supply of Gas shall be measured and paid separately as supply only) (Make: Blue Star/LG/Hitachi/Voltas/Carrier) |
| 27 | S & F in repairs complete outer body of Indoor unit of Split type AC of 1.5/2 Ton capacity in situ as per the existing make and competible model with Cooling Unit, PCB, Blower Unit with motor, Swing motor, remote unit, necessary electrical connections and copper tubing by gas welding, gas charging with R-32 and testing after completion with entire satisfection of Engr-in-Charge complete all as specified and directed. (Note: Supply of Gas shall be measured and paid separately as supply only) (Make: Blue Star/LG/Hitachi/Voltas/Carrier) |
| 28 | S & F in repairs complete outer body of window AC of 1.5 Ton capacity including fan motor, evaporator, condenser and all other accessories but exluding compressor complete all as per the existing make and specifications complete all as specified and as directed. |
| 29 | S&F in repair voltage stabiliser of any make and phase with input voltage 135-190 Volts and output voltage 180-270volts, capacity upto 4 KVA by dismantling and taking out burnt main transformer and rewinding the same with suitable guage super enamelled copper winding wire, varnishing, etc., complete including replacement of unserviceable/ defective volt meter (0-300 volts), relay, indicator, terminal plate complete all as specified and directed.(Make of voltmeter: AE/Primer) |
| 30 | M & L for Repair to voltage stabiliser of any make phase with input voltage 135-190 Volts and output voltage 200-240 volts, capacity upto 5 KVA by dismantling and taking out burnt main transformer and rewinding the same with suitable guage super enamelled copper winding wire, varnishing, etc., complete including replacement of unserviceable/defective volt meter (0-300 volts), relay, indicator, terminal plate complete all as specified and directed.(Make of voltmeter: AE/Primer) |
| 31 | Water cooler :Taking down unserviceable water cooler of capacity 40/80 ltr from the existing position and transporting the same to workshop for repair, removing unserviceable burnt sealed compressor unit from the water cooler and S & F factory sealed new compressor duly charged with compressor oil and gas including welding in position and testing at required pressure and transporting the water cooler to its original location complete all as specified and as directed. (Make : Usha/Arco/Sidhwal or approved make) (Note : Gas shall be measured and paid separately as supply only under respective item of BOQ.) |
| 32 | M & L for Cleaning the water cooler of capacity 40/80 ltr with CTC and charging with refrigent gas as required and checking of leakage in the water cooler complete all as specified and as directed. |
| 33 | Supply and fix in repairs running capacitor suitable for water cooler of capacity 40/80 Ltrs complete all as specified and as directed. |
| 34 | Supply and fix in repairs starting relay suitable for water cooler of capacity 40/80 Ltrs complete all as specified and as directed. |
| 35 | Supply and fix in repairs over load protector suitable for water cooler of capacity 40/80 Ltrs complete all as specified and as directed. (Make : Renutral/Techno Mech) |
| 36 | Supply and fix in repairs Starting capacitor suitable for water cooler of capacity 40/80 Ltrs complete all as specified and as directed. (Make : Asian/Unistar/Arvind.) |
| 37 | Taking out old unserviceable internal wiring and rewiring the same with 40/0.0076 size flexible copper conductor single core with terminal clips etc including screws, washers etc required for fastening with body complete all as specified and as directed. |
| 38 | Taking down rusted back body MS cover and S & F new 2mm thick MS plate cover of duly painted to match the existing water cooler of capapcity 40/80 Ltrs complete all as specified and as directed. |
| 39 | All as per serial item No. 38above but front panel body complete and ditto |
| 40 | S & F in repairs MS chromium plated drip tray assembly of water cooler of capacity 40/80 Ltrs complete with elbow complete all as specified and as directed. |
| 41 | S & F in repair float valve with polythene ball complete all as per existing specifications, 15mm bore suitable for water cooler of capacity 40/80 ltrs complete all as specified and as directed. |
| 42 | S & F in repair self closing chromium plated push cock, 15mm bore heavy duty suitable for water cooler of capacity 40/80 ltrs complete all as specified and as directed. |
| 43 | Taking out unserviceable fan motor and rewinding the same with suitable gauge copper winding wire including replacement of bushes, rubber, mounting clips, insulation and commissioning for 40/80 ltr water cooler complete all as specified and as directed. |
| 44 | S & F in repairs fan motor suitable for water cooler of capacity 40/80 ltr complete all as specified and as directed. (Make – Cool/EME/Crompton.) |
| 45 | M & L for cleaning of water cooler of capacity 40/80 Ltrs complete internally and externally including scraping and removing all scales and dirt etc and applying two coats of synthetic enamel hammer tone paint over one coat of red oxide of primer and writing of SM/MES No in 3 cm high complete all as specified and as directed. |
| 46 | Refrigerators :Taking down unserviceable refrigerator of capacity 310/286 ltr from the site and transporting the same to work shop for repair/removing unserviceable burnt compressor sealed unit and supply and fix factory sealed new compressor duly charged with compressor oil and gas including welding in position and testing on required pressure and transporting back to its site and fix in original location complete all as specified and as directed.(Note : Supply of Gas shall be measured and paid separately as supply only.) |
| 47 | All as per serial item No. 46 above but for 190 Ltr capacity refrigerator complete ditto |
| 48 | All as per serial item No. 46 above but for 165 Ltr capacity refrigerator complete ditto |
| 49 | M & L for Cleaning the complete system of refrigerator of capacity 310/286/190/165 ltrs and recharging of gas, checking leakage from system and testing complete all as specified and as directed. |
| 50 | S & F in repairs freezer door (plastic) complete with tension spring as per the original one suitable for refrigerator of capacity 310/286/190/165 Ltrs complete all as specified and as directed. |
| 51 | S & F in repairs refrigerator tray as per the original one suitable for refrigerator of capacity 310/286/190/165 Ltrs complete all as specified and as directed. |
| 52 | S & F in repairs fruit/vegetable tray as per the original one suitable for refrigerator of capacity 310/286/190/165 Ltrs complete all as specified and as directed. |
| 53 | S & F in repairs pigmy lamp (bulb) as per the original one suitable for refrigerator of capacity 310/286/190/165 Ltrs complete all as specified and as directed. |
| 54 | S & F in repairs door lever (PVC) as per the original one suitable for refrigerator of capacity 310/286/190/165 Ltrs complete all as specified and as directed. |
| 55 | S & F in repairs relay, box type as per the original one suitable for refrigerator of capacity 310/286/190/165 Ltrs complete all as specified and as directed. |
| 56 | S & F in repairs overload protector as per the original one suitable for refrigerator of capacity 310/286/190/165 Ltrs complete all as specified and as directed.(Make: Renutral/Sriram) |
| 57 | M & L for Opening of regrigator of capacity 310/286 ltr and refixing the same after flushing out and removal of blockage, brazing, replacement of liquid line filter and rechanging the gas to obtain the desired cooling complete all as specified and as directed.(Note : Supply of Gas shall be measured and paid separately as supply only). |
| 58 | All as per serial item No. 57 above but for refrigerator of capacity 190 ltrs complete and ditto. |
| 59 | All as per serial item No. 57 above but for refrigerator of capacity 165 ltrs complete and ditto. |
| 60 | S & F in repair door lock with two keys as per the existing specifications complete all as directed |
| 61 | M & L for preparation of surfaces after complete removal of existing treatment and applying spray painting with two coats synthetic enamel paint over a coat of red oxide primer to refrigerator of capacity 310/286/190/165 ltr of any make/model complete all as specified and as directed. |
| 62 | Supply only Refrigerant gas in company sealed cylinder for R-22/ R-32/R-600/R-134A/R-407C Gas as required at site for all types of cooling appliances complete all as specified and as directed. |
| 63 | Cutting the existing ceiling, making/providing holes for the repair of the inner unit if leakage is found, brazing /scaling the same with approved sealing materials and making good as per the existing ceiling complete all as specified and directed Please Enable Macros to View BoQ information |
| 64 | Cutting the existing ceiling, making/providing holes for the repair of the inner unit if leakage is found, brazing /scaling the same with approved sealing materials and making good as per the existing ceiling complete all as specified and directed Please Enable Macros to View BoQ information |