| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.50 mtr depth for foundation etc or for shafts, wells, cesspits, main holes, pier holes etc complete in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling including spreading, levelling, watering and well ramming in layers n.exe. 25 cm thick in soft/loose soil complete all as specified and directed. |
| 3 | Removing excavated materials not exc 50 mtr and deposited where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and as directed. |
| 4 | M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate in foundation , filing and mass concrete complete all as specified and directed. |
| 5 | M&L for PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in coping complete all as specified and directed. |
| 6 | Demolition of brick work of any description and in any position built in cement mortar and removing rubbish n.exc 50m complete all as specified and directed. |
| 7 | M&L for brick work with sub class 'B' bricks old size straight or curved on plan exc 6mtr mean radius, built in CM (1:4) complete all as specified and directed. |
| 8 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM in (1:4) finished fair and even external surface complete all as specified and directed. |
| 9 | M & L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening with Fe 410 -W (Gde- E- 250) quality- A and fixing two coats of black bituminous paint over one coat of red oxide primer complete as directed by Engineer-in charge. |
| 10 | Taking up/down CI/DI defective/leaked water mains 80mm dia bore (including fittings) with spigot and socket ends & rubber joint, lead joints including burning out joint and recovering lead complete all as specified and directed by Engineer-in-Charge. |
| 11 | All as per item No 10 above but 100mm dia bore |
| 12 | All as per item No 10 above but 150mm dia bore |
| 13 | All as per item No 10 above but 200mm dia bore |
| 14 | All as per item No 10 above but 250mm dia bore |
| 15 | All as per item No 10 above but 300mm dia bore |
| 16 | All as per item No 10 above but 400mm dia bore |
| 17 | Suplying, laying, jointing & testing in repair of ductile iron (DI) pipes of 100mm dia bore with spigot ends, class K-7, centrifugaly cast conforming to IS-8329 specifications, lining, in any length, laid in trenches complete with and including necessary rubber gasket joints complete all as specified and directed. (Both for 100 mm Pipe & 80 mm CI Pipe replacement) |
| 18 | Suplying, laying, jointing & testing in repair of ductile iron (DI) pipes of 150mm dia bore with spigot ends, class K-7, centrifugaly cast conforming to IS-8329 specifications, lining, in any length, laid in trenches complete with and including necessary rubber gasket joints complete all as specified and directed. |
| 19 | Suplying, laying, jointing & testing in repair of ductile iron (DI) pipes of 200mm dia bore with spigot ends, class K-9, centrifugaly cast conforming to IS-8329 specifications, lining, in any length, laid in trenches complete with and including necessary rubber gasket joints complete all as specified and directed. |
| 20 | Suplying, laying, jointing & testing in repair of ductile iron (DI) pipes of 250mm dia bore with spigot ends, class K-9, centrifugaly cast conforming to IS-8329 specifications, lining, in any length, laid in trenches complete with and including necessary rubber gasket joints complete all as specified and directed. |
| 21 | Suplying, laying, jointing & testing in repair of ductile iron (DI) pipes of 300mm dia bore with spigot ends, class K-9, centrifugaly cast conforming to IS-8329 specifications, lining, in any length, laid in trenches complete with and including necessary rubber gasket joints complete all as specified and directed. |
| 22 | Suplying, laying, jointing & testing in repair of ductile iron (DI) pipes of 400mm dia bore with spigot ends, class K-9, centrifugaly cast conforming to IS-8329 specifications, lining, in any length, laid in trenches complete with and including necessary rubber gasket joints complete all as specified and directed.Note for BOQ Ser item No 10 to 22 :- Excavation & earth work for pipes shall be measured and paid for seperately under appropriate item of this schedule. |
| 23 | S&F Cast iron fittings of any descripition, i.e. bends (any type, radius and angle), Tapers any type, (straight, bend, increasing , decreasing or double socket etc.) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot end or flanged ends as directed) including collars, caps and plugs, upto 150 mm bore of pipes, ISI Marked, complete including all neccessary earth work, lifting of pipe, dewatering & taking out old fitting all as specified and directed. |
| 24 | S&F Cast iron fittings of any descripition, i.e. bends (any type, radius and angle), Tapers any type, (straight, bend, increasing , decreasing or double socket etc.) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot end or flanged ends as directed) including collars, caps and plugs, 200 mm to 250 mm bore of pipes, ISI Marked, complete including all neccessary earth work, lifting of pipe, dewatering & taking out old fitting all as specified and directed. |
| 25 | S&F Ductile iron fittings of such as i.e. bends (any type, radius and angle), Tapers any type, (straight, bend, increasing , decreasing or double socket etc.) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot and/ or flanged ends as directed) including collars, caps and plugs above 250 mm bore of pipes, ISI Marked, complete including all neccessary earth work, lifting of pipe, dewatering & taking out old fitting all as specified and directed. |
| 26 | Taking out unservicable GI pipe 80mm dia and supplying & laying of 80mm dia pipe (including GI fittings) laid in the same trench complete all are specified and directed.Note :- Necessary excavation & earth work for pipes shall be measured and paid for seperately under appropriate item of this schedule. Please Enable Macros to View BoQ information |
| 27 | Taking out unservicable GI pipe 80mm dia and supplying & laying of 80mm dia pipe (including GI fittings) laid in the same trench complete all are specified and directed.Note :- Necessary excavation & earth work for pipes shall be measured and paid for seperately under appropriate item of this schedule. Please Enable Macros to View BoQ information |