| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in concrete, brick work, masonry etc. and making good disturbed ground complete all as specified and as directed. |
| 2 | Dismantling fencing wire mesh of any type of any description fixed to any type of fencing posts complete all as specified and as directed. |
| 3 | Dismantling structural steel work including door gates etc complete all as specified and as directed. |
| 4 | Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 5 | Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/ brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed. |
| 6 | Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface in soft/ loose soil complete all as specified & as directed. |
| 7 | Supply & fixing mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, MS flat iron, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290, Grade E-165 (Fe 290), complete all as specified & as directed. |
| 8 | S & F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 9 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Dismantling of plain or corrugated steel sheeting any gauge or thickness in roof coverings incl ridge complete all as specified and as directed by Engineer-in-Charge. |
| 11 | M & L for Cement concrete 1:3:6, type C-2 using 40 mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 12 | Fixing only mild steel galvanized chain link fencing, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire complete all as specified and as directed.Note :- Supply only chain link fencing shall be measured and paid for separately. |
| 13 | Supply only chain link mild steel galvanised fencing (mesh size 75mm x 75mm of 3mm dia wire) complete all as specified and directed.Note : The weight of chain link fencing shall be ascertained by BOO as ordered by GE and payment shall be made accordingly. |
| 14 | Supply & fixing mild steel round bars 10mm dia as in tie bars fixed to fencing posts including cut to length, bent to shape, welding of bar at spots as directed and other similar works, conforming to Grade E-165 (Fe 290), complete all as specified & as directed. |
| 15 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc 5 cm long and dia of neck 11 to 15 mm complete all as specified & as directed. |
| 16 | S&F mild steel framed work as in doors, gates, steel frames, chowkats, etc. of angle or other section with gusset plates, rails, braces, etc., complete conforming to Grade E-165 (Fe 290), drilled for fixing of steel sheeting or other covering including necessary welding etc and fixing in position complete all as specified and as directed. |
| 17 | Supply & fixing mild steel flat iron as in fencing including drilling holes, MS flat iron, notching for wire, etc. (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Grade E-165 (Fe 290), complete all as specified & as directed. |
| 18 | Supply & fixing galvanized 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc complete all as specified & as directed.Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment. |
| 19 | M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 20 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed. |
| 21 | Dismantling of PCC paver blocks of any description laid bedded dry from path/hard standing including removal dry screed bed complete all as specified and as directed by Engineer-in-Charge. |
| 22 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed. |
| 23 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified & as directed. |
| 24 | M&L for 75 mm thick PCC (1:4:8), type D2 using 40mm graded stone agg as in sub base of floors etc finished even and rough complete all as specified and as directed. |
| 25 | Material and labour for 25mm thick sand filling under floor, cushioning under interlocking tiles or in foundation including watering and consolidation complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 27 | M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 28 | M&L for factory made chequered cement concrete tiles, 30cm x 30cm x 25mm thick, rubber finish glazed top with grey cement & pigment, machine pressed, set, jointed and pointed in neat cement slurry in floors with grey cement & pigment, over & including 20mm thick screed bed in cement & sand mortar 1:6, complete all as specified & as directed. |
| 29 | M&L for 75mm thick PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in plinth protection/ hard standing surface finished even and smooth without using extra cement complete all as specified and directed. Note :- Plinth protection/hard standing shall be of width as directed and shall be laid with an outward slope of 1:30 in alternative bays not exceeding 4 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3). |
| 30 | M&L for 70mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in flooring/hardstanding surface finished even and smooth without using extra cement in alternate panels including necessary formwork complete all as specified and as directed. Note :- Hard standing shall be of width as directed and shall be laid in alternative bays not exceeding 2.5 Sqmtr each panel,. Joints shall be filled with bitumen mastic (1:3). |
| 31 | M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed. |
| 32 | M&L for Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 33 | M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed. |
| 34 | M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed. |
| 35 | M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed. |
| 36 | M&L for welding metal of thickness exc 6mm but not exc 9mm and length n.exc 2.5cm complete all as specified and as directed. |
| 37 | M&L for repairing of chajjas/roof projection/roof spouts by taking down old plaster and applying 10-20mm thick rendering in cement mortar 1:3 and finished without using extra cement and finished with two coats of exterior emulsion paint over a coat of cement primer, complete all as specified and as directed. |
| 38 | Demolition of stone or boulder masonary, built in lime mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone and pre-cast articles complete all as specified and as directed. |
| 39 | M&L for factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without groove (thickness of joint except at sharp curve shall not to more than 5mm), including making drainage opening complete all as specified & as directed. Please Enable Macros to View BoQ information |