| 1 | Septic tank and pipe line work |
| 2 | OD247869/2025-2026:Removing the existing factory made coloured chamfered edge Cement Concrete paver blocks and relaying the same after levelling the bed of metal chips, compacting and filling the joints and cutting of paver blocks as per required size and pattern, finishing etc. complete as per manufacturer's specifications & direction of Engineerin-Charge. |
| 3 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 4 | 2.20.2:Open timbering in trenches including strutting and shoring complete ( measurements to be taken of the face area timbered ):Depth exceeding 1.5 m but not exceeding 3 m |
| 5 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 6 | 13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 7 | OD248393/2025-2026:Sinking of 120 cm dia concrete ring in ordinary soil including cost of all materials, labour charge necessary scooping etc. all complete as per direction of engineer in charge |
| 8 | 4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 9 | OD248261/2025-2026:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement cost shall not be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cementAll work upto plinth level: Concrete of M30 grade with minimum cement content of 340 kg /cum |
| 10 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 11 | 50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete |
| 12 | 50.18.9.10.1:Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 |
| 13 | OD51783/2026-2027:Constructing Concrete masonry manhole in C.C. 1:2:4 mix with wall thickness 15 cm (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) wth foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x90 cm and up to 30 cm deep with low duty cast iron covering slab |
| 14 | OD51784/2026-2027:Extra for additional height of manhole with cement concrete 1:2:4 with wall thickness 15 cm for inside size 90x90cm |
| 15 | 50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 16 | OD247983/2025-2026:Engaging labour for various works |
| 17 | OD247984/2025-2026:Disposal of building rubbish /malda/similar unserviceable , dismantled or waste materials by machanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer in charge beyond 50 m initial lead, for all leads including all lifts involved. |
| 18 | OD247985/2025-2026:Cleaning the blocked up sewage line using sewage cleaning rod and put up the same in working order etc |
| 19 | OD247986/2025-2026:Cleaning the blocked up and not working sewer manhole of size 0.60 x 0.60x1.20m including of black earth etc. |
| 20 | 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete Please Enable Macros to View BoQ information |