Housing Urban and Rular Development Government Departments Closing in 0 days TDR #55999522

Tender For Construction Of Sale Building No. S-34 Consisting Of 208 Tenements In The Slum Rehabilitation Scheme At Turbhe Mandale, Mankhurd

Issued by Government Departments · Turbhe, Maharashtra
Tender Value
58.36 Crore
Estimated cost
Bid Submission
10 Jul 2026
0 days left
EMD
29.18 Lakhs
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Turbhe → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Sale Building No. S-34 Consisting Of 208 Tenements In The Slum Rehabilitation Scheme At Turbhe Mandale, Mankhurd

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 02-Jul-2026 Common Set of Deviation / Addendum Technical Bid 10-Jul-2026

BOQ

Name of Work:- Construction of sale building no. S-34 Consisting of 208 tenements in the slum rehabilitation scheme at Turbhe Mandale, Mankhurd
Sl. No. Item Description
1Excavation for foundation in earth, Soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area & stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
2Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary)
3Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc.complete.
4Coveyance of material/Debris at a distance of 15 km as directed by the Engineer In charge ( Lead charges of \\" Rubbish as per Lead statement C-1 page 560 of SSR 2022-23 for 5 Km
5Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of chloropyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.
6Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.
7Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed), with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
8Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete.
91st Floor
102nd Floor
11Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )
12Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)
13Raft,Retaining wall - Providing and applying required coats of a water based Evercrete Deep Penetrating Sealer (DPS) on cement concrete surface like roads, beams, and columns, plastered walls, basements, roofs, potable water tanks etc to react with cement and to penetrate concrete structure thereby making it resistant to chemicals / chlorides water to make it dust proof and to act as a water resistant at the same time which Strengthens the treated surface and reduce the curing period etc complete. - Note -- for item One Number 7 to 4 prior approval of Superintending Engineer will be necessary
144th Floor
15Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap metal for R.C.C. pile caps as per detailed designs and drawings, including bailing out water manually, centering, formwork, laying/ pumping, compacting, finishing and curing etc. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) complete. (Excluding steel reinforcement)
16Providing supply and installation of Driven RCC Precast vertical / raker piles of circular shape of M35 grade as per IS 2911 (Part 1, Section 3) from the approved manufacturer (Manufacture of precast concrete piles shall confirm to the guidelines in clause no. 7.1, 7.2 and 7.3 of IS 2911 (Part 1, Section 3)) and handling, lifting, pitching and driving of piles through loose to medium sands (casted with MS Shoe (flat/ conical)) by Vibrating Pile driving hammer to the specified depth or refusal as specified for the desired set criteria (to be finalzed during detailed engineering stage ) so as to achieve the safe load carrying capcity as per the design. Breaking/chipping pile head to cutoff level and exposing pile reinforcement for embedment in pile cap and including approved MS shoe ( design and drawing of MS shoe shall be submitted for approval without any extra cost to MCGM), all complete for piles having diameter of ( vertical /raker piles will be measured for payment for a length between pile tip to cut-off level along the pile axis) 500mm
17600mm
18750mm
19Carrying out low strain pile integrity test including all arrangements for test, equipments/accessories, materials, labour, submission of test report etc but excluding the cost of installation of job pile (installation of pile shall be paid seperately as per relevent items)all complete as per specification and as directed by the engineer-in-charge.600mm
20750mm
21Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement
22Ground Floor
231st Floor
242nd Floor
253rd Floor
264th Floor
27Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement
28Ground Floor
291st Floor
302nd Floor
313rd Floor
324th Floor
33Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement
341st Floor
352nd Floor
363rd Floor
374th Floor
38Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 5th Floor
396th Floor
407th Floor
418th Floor
42Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for R.C.C. Beams as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 5th Floor
436th Floor
447th Floor
458th Floor
46Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for R.C.C. Slab as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 5th Floor
476th Floor
487th Floor
498th Floor
50Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for External Structural Wall as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 5th Floor
516th Floor
527th Floor
538th Floor
54Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 9th Floor
5510th Floor
5611th Floor
5712th Floor
5813th Floor
5914th Floor
6015th Floor
61Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite /quartzite/ gneiss metal for R.C.C. Beams as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 9th Floor
6210th Floor
6311th Floor
6412th Floor
6513th Floor
6614th Floor
6715th Floor
68Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite /quartzite/ gneiss metal for R.C.C. Slab as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 9th Floor
6910th Floor
7011th Floor
7112th Floor
7213th Floor
7314th Floor
7415th Floor
75Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite /quartzite/ gneiss metal for External Structural Wall as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 9th Floor
7610th Floor
7711th Floor
7812th Floor
7913th Floor
8014th Floor
8115th Floor
82Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 16th Floor
8317th Floor
8418th Floor
8519th Floor
8620th Floor
8721st Floor
8822nd Floor
89Terrace Floor
90Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. Beams as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 16th Floor
9117th Floor
9218th Floor
9319th Floor
9420th Floor
9521st Floor
9622nd Floor
97Terrace Floor
98Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. Slab as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 16th Floor
9917th Floor
10018th Floor
10119th Floor
10220th Floor
10321st Floor
10422nd Floor
105Terrace Floor
106Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for External Structural Wall as per detailed designs and drawing or as directed cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel, centering, formwork,).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 16th Floor
10717th Floor
10818th Floor
10919th Floor
11020th Floor
11121st Floor
11222nd Floor
113Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
114Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
115Providing & fixing of costomized Aluminium formwork for monolithic construction RCC member with respective uses of 100 times using grade 5052 aluminium for panel sheet of minimum 4 mm thick and grade 6061 (type 6) aluminium for extruded section. The formwork includes beam i.e. beam side component prop head for soffit beam , beam soffit panel, beam soffit bulk head and deck component i.e. deck panel, deck prop, prop lenght, deck mid, soffit lenght, deck beam bar, and wall component,i.e. wall panel, rocker, kiker, and internal soffit corner, externel soffit corner internal corner, externel corners etc, The panels are held in position by a simple pin and wedge system that passes through holes in the out side rub of each panel. The tolerence of finished panel to be (1 mm) shall be confirmed to IS 14687:1999 pins and wedges to be made of high grade mild steel, All complete as per direction of engineer incharge ( Cost of RCC work shall be paid seperately)
116Providing and fixing in position TMT FE-500bar Reinforcement of various diaMetres for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels,pardies coping, fins, arches, etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete.Basement
117Ground Floor
1181st Floor
1192nd Floor
1203rd Floor
1214th Floor
1225th Floor
1236th Floor
1247th Floor
1258th Floor
1269th Floor
12710th Floor
12811th Floor
12912th Floor
13013th Floor
13114th Floor
13215th Floor
13316th Floor
13417th Floor
13518th Floor
13619th Floor
13720th Floor
13821st Floor
13922nd Floor
140Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Basement
141Ground Floor
1421st Floor
1432nd Floor
1443rd Floor
1454th Floor
1465th Floor
1476th Floor
1487th Floor
1498th Floor
1509th Floor
15110th Floor
15211th Floor
15312th Floor
15413th Floor
15514th Floor
15615th Floor
15716th Floor
15817th Floor
15918th Floor
16019th Floor
16120th Floor
16221st Floor
16322nd Floor
164Terrace Floor
165Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Basement
166Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Basement
167Ground Floor
1681st Floor
1692nd Floor
1703rd Floor
1714th Floor
1725th Floor
1736th Floor
1747th Floor
1758th Floor
1769th Floor
17710th Floor
17811th Floor
17912th Floor
18013th Floor
18114th Floor
18215th Floor
18316th Floor
18417th Floor
18518th Floor
18619th Floor
18720th Floor
18821st Floor
18922nd Floor
190Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
1913rd Floor
1925th Floor
1936th Floor
1947th Floor
1958th Floor
1969th Floor
19710th Floor
19811th Floor
19912th Floor
20013th Floor
20114th Floor
20215th Floor
20316th Floor
20417th Floor
20518th Floor
20619th Floor
20720th Floor
20821st Floor
20922nd Floor
210Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Basement
211Ground Floor
2121st Floor
2132nd Floor
2143rd Floor
2154th Floor
2165th Floor
2176th Floor
2187th Floor
2198th Floor
2209th Floor
22110th Floor
22211th Floor
22312th Floor
22413th Floor
22514th Floor
22615th Floor
22716th Floor
22817th Floor
22918th Floor
23019th Floor
23120th Floor
23221st Floor
23322nd Floor
234Providing and applying a base coat comprising of 1Kilogram Polydee-MC and 1Kilogram fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. Basement
2354th Floor
236Providing cement based Water Proofing Treatment to Terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
237Terrace Floor
238Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc.complete. Ground Floor
2393rd Floor
2405th Floor
2416th Floor
2427th Floor
2438th Floor
2449th Floor
24510th Floor
24611th Floor
24712th Floor
24813th Floor
24914th Floor
25015th Floor
25116th Floor
25217th Floor
25318th Floor
25419th Floor
25520th Floor
25621st Floor
25722nd Floor
258Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. 5th Floor
2596th Floor
2607th Floor
2618th Floor
2629th Floor
26310th Floor
26411th Floor
26512th Floor
26613th Floor
26714th Floor
26815th Floor
26916th Floor
27017th Floor
27118th Floor
27219th Floor
27320th Floor
27421st Floor
27522nd Floor
276Providing and laying Vitrified tlles (Matt and Antiskid finish) In floor in 800milimeter x 1200milimeter sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S: 15622, of approved brand and manufacturer, in all colours and shade, lald on 20 millmeter thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slury @3.3 kg/sgm including grouting the joints with white cement and matching pigments excetra The tiles must be cut with the zero chipping diametermond cutter only Laying of tiles will be done with the notch trowel, plier, wedge clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.as directed by engineer-in- Charge. Basement Floor
277Ground Floor
2781st Floor
2792nd Floor
2803rd Floor
2814th Floor
2825th Floor
2836th Floor
2847th Floor
2858th Floor
2869th Floor
28710th Floor
28811th Floor
28912th Floor
29013th Floor
29114th Floor
29215th Floor
29316th Floor
29417th Floor
29518th Floor
29619th Floor
29720th Floor
29821st Floor
29922nd Floor
300Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.
3011st Floor
3023rd Floor
3034th Floor
3045th Floor
3056th Floor
3067th Floor
3078th Floor
3089th Floor
30910th Floor
31011th Floor
31112th Floor
31213th Floor
31314th Floor
31415th Floor
31516th Floor
31617th Floor
31718th Floor
31819th Floor
31920th Floor
32021st Floor
32122nd Floor
322Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete
3231st Floor
3243rd Floor
3255th Floor
3266th Floor
3277th Floor
3288th Floor
3299th Floor
33010th Floor
33111th Floor
33212th Floor
33313th Floor
33414th Floor
33515th Floor
33616th Floor
33717th Floor
33818th Floor
33919th Floor
34020th Floor
34121st Floor
34222nd Floor
343Providing and laying Vitrified Matt finish tiles having size 590mm to 605mm x 590 mm to 605mm of 8 to10 mm thickness and confirming to IS.15622-2006 (groupBla)of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc.complete.
3443rd Floor
3455th Floor
3466th Floor
3477th Floor
3488th Floor
3499th Floor
35010th Floor
35111th Floor
35212th Floor
35313th Floor
35414th Floor
35515th Floor
35616th Floor
35717th Floor
35818th Floor
35919th Floor
36020th Floor
36121st Floor
36222nd Floor
363Providing and laying telephone black / Amba White / Cadburybrown / RBI red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.
3641st Floor
3652nd Floor
3663rd Floor
3674th Floor
3685th Floor
3696th Floor
3707th Floor
3718th Floor
3729th Floor
37310th Floor
37411th Floor
37512th Floor
37613th Floor
37714th Floor
37815th Floor
37916th Floor
38017th Floor
38118th Floor
38219th Floor
38320th Floor
38421st Floor
38522nd Floor
386Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement ftoats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Basement
387Ground Floor
3881st Floor
3892nd Floor
3903rd Floor
3914th Floor
3925th Floor
3936th Floor
3947th Floor
3958th Floor
3969th Floor
39710th Floor
39811th Floor
39912th Floor
40013th Floor
40114th Floor
40215th Floor
40316th Floor
40417th Floor
40518th Floor
40619th Floor
40720th Floor
40821st Floor
40922nd Floor
410Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Basement
411Ground Floor
4121st Floor
4132nd Floor
4143rd Floor
4154th Floor
4165th Floor
4176th Floor
4187th Floor
4198th Floor
4209th Floor
42110th Floor
42211th Floor
42312th Floor
42413th Floor
42514th Floor
42615th Floor
42716th Floor
42817th Floor
42918th Floor
43019th Floor
43120th Floor
43221st Floor
43322nd Floor
434Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.Ground Floor
4353rd Floor
4364th Floor
4377th Floor
43812th Floor
43917th Floor
440Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. Ground Floor
4413rd Floor
4427th Floor
44312th Floor
44417th Floor
445Providing and constructing Granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.0 m x 0.60 m and height is 0.75 m). 3rd Floor
4465th Floor
4476th Floor
4487th Floor
4498th Floor
4509th Floor
45110th Floor
45211th Floor
45312th Floor
45413th Floor
45514th Floor
45615th Floor
45716th Floor
45817th Floor
45918th Floor
46019th Floor
46120th Floor
46221st Floor
46322nd Floor
464Providing & Fixing in position, Carpet more than 800 + gsm, made with100 % stain proof fibres of approved make along with 5mm underlay as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishing etc complete. 3rd Floor
465Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. Basement
466Ground Floor
4671st Floor
4682nd Floor
4693rd Floor
4704th Floor
471Providing and applying priming coat on concrete/ masonry/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Basement
472Ground Floor
4731st Floor
4742nd Floor
4753rd Floor
4764th Floor
4775th Floor
4786th Floor
4797th Floor
4808th Floor
4819th Floor
48210th Floor
48311th Floor
48412th Floor
48513th Floor
48614th Floor
48715th Floor
48816th Floor
48917th Floor
49018th Floor
49119th Floor
49220th Floor
49321st Floor
49422nd Floor
495Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. Basement
496Ground Floor
4971st Floor
4982nd Floor
4993rd Floor
5004th Floor
5015th Floor
5026th Floor
5037th Floor
5048th Floor
5059th Floor
50610th Floor
50711th Floor
50812th Floor
50913th Floor
51014th Floor
51115th Floor
51216th Floor
51317th Floor
51418th Floor
51519th Floor
51620th Floor
51721st Floor
51822nd Floor
519Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applying wall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.)
5201st Floor
5213rd Floor
5224th Floor
5235th Floor
5246th Floor
5257th Floor
5268th Floor
5279th Floor
52810th Floor
52911th Floor
53012th Floor
53113th Floor
53214th Floor
53315th Floor
53416th Floor
53517th Floor
53618th Floor
53719th Floor
53820th Floor
53921st Floor
54022nd Floor
541Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary
5421st Floor
5432nd Floor
5443rd Floor
5454th Floor
5465th Floor
5476th Floor
5487th Floor
5498th Floor
5509th Floor
55110th Floor
55211th Floor
55312th Floor
55413th Floor
55514th Floor
55615th Floor
55716th Floor
55817th Floor
55918th Floor
56019th Floor
56120th Floor
56221st Floor
56322nd Floor
564Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Basement
565Ground Floor
5661st Floor
5672nd Floor
5683rd Floor
5694th Floor
5705th Floor
5716th Floor
5727th Floor
5738th Floor
5749th Floor
57510th Floor
57611th Floor
57712th Floor
57813th Floor
57914th Floor
58015th Floor
58116th Floor
58217th Floor
58318th Floor
58419th Floor
58520th Floor
58621st Floor
58722nd Floor
588Terrace Floor
589Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Basement
5901st Floor
5913rd Floor
5924th Floor
5935th Floor
5946th Floor
5957th Floor
5968th Floor
5979th Floor
59810th Floor
59911th Floor
60012th Floor
60113th Floor
60214th Floor
60315th Floor
60416th Floor
60517th Floor
60618th Floor
60719th Floor
60820th Floor
60921st Floor
61022nd Floor
611Terrace Floor
612Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter Basement
613Ground Floor
6141st Floor
6152nd Floor
6163rd Floor
6174th Floor
6185th Floor
6196th Floor
6207th Floor
6218th Floor
6229th Floor
62310th Floor
62411th Floor
62512th Floor
62613th Floor
62714th Floor
62815th Floor
62916th Floor
63017th Floor
63118th Floor
63219th Floor
63320th Floor
63421st Floor
63522nd Floor
636Providing & fixing factory-made Single leaf 2 hour fire rated door as per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80, tested at NTL/CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143 \times 58 \text{ mm}$ and thickness of $1.6 \text{ mm}$ thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of $46 \text{ mm}$ thickness and constructed from $1.2 \text{ mm}$ thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of $5 \text{mm}$ thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness $60 \text{ micron}$ e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt, Mortise latch, Door closer, Panic bar and external trim lock and Flush bolts complete. Basement
637Ground Floor
6381st Floor
6392nd Floor
6403rd Floor
6414th Floor
6425th Floor
6436th Floor
6447th Floor
6458th Floor
6469th Floor
64710th Floor
64811th Floor
64912th Floor
65013th Floor
65114th Floor
65215th Floor
65316th Floor
65417th Floor
65518th Floor
65619th Floor
65720th Floor
65821st Floor
65922nd Floor
660Providing and fixing glazing panels & doors using 12mm thk toughen clear glass (confirming to ASTM Standards C-1048) supported byc-channel (embedded in the floor) at the bottom & side edge and wall connecting profile at the top edge,stainless steel articulated countersunk bolts threaded bolts,chemical fasterners,etc., glass panel size as per design and drawing including applying colourless sealant of joint incl. required edge polish, making glazing water tight etc. Destructive node joint test reports to be submitted forestablishing the safety factor, including operating hardware, SS patch fittings, fabricated long length satin finish SS 304 handles,patchlock, floor springs etc., complete as directed by the architect for frameless patch doors,single or twin leaf shutters with fixed panel on top. Hardware-Droma BTS 80 Floor Spring.
6611st Floor
662Providing and fixing Rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)
663Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating without box
6641st Floor
6652nd Floor
6663rd Floor
6674th Floor
6685th Floor
6696th Floor
6707th Floor
6718th Floor
6729th Floor
67310th Floor
67411th Floor
67512th Floor
67613th Floor
67714th Floor
67815th Floor
67916th Floor
68017th Floor
68118th Floor
68219th Floor
68320th Floor
68421st Floor
68522nd Floor
686Terrace Floor
687Providing and fixing SS Mosquito mesh in anodised (anodic film must not be less than 15 microns i.e. AC-15 as per IS, the anodising must be scaleted by keeping the anodized section in boiling de-anodized water for a period of one hour) aluminium shutter fixed in sliding / openable / fixed windows conforming to IS:1948-1961 as per drawing and directed by Engineer In Charge. (Note: For Aluminum Sections, total weight shall be upto 3.5 kg/sq.m.)
6881st Floor
6892nd Floor
6903rd Floor
6914th Floor
6925th Floor
6936th Floor
6947th Floor
6958th Floor
6969th Floor
69710th Floor
69811th Floor
69912th Floor
70013th Floor
70114th Floor
70215th Floor
70316th Floor
70417th Floor
70518th Floor
70619th Floor
70720th Floor
70821st Floor
70922nd Floor
710Terrace
711Providing and fixing in position powder coated Aluminum louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminum frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Ground Floor
7123rd Floor
7135th Floor
7146th Floor
7157th Floor
7168th Floor
7179th Floor
71810th Floor
71911th Floor
72012th Floor
72113th Floor
72214th Floor
72315th Floor
72416th Floor
72517th Floor
72618th Floor
72719th Floor
72820th Floor
72921st Floor
73022nd Floor
731Providing and fixing in position Top/side hung window of extruded modular and anodised aluminum sections of approved make and of size 38.10 mm x 25.40 mm x 1.44 mm thk (wt. 0.471 kg/Rm) for outer rectangular tube, 40 mm x 31.5 mm x 1.5 mm (wt. 0.549 kg/Rm) for outer frame, 40 mm x 31.50 mm x 1.50 mm thk (wt. 0.502 kg/Rm) for central mullion, 40 mm x 31.50 mm x 1.50 mm thk (wt. 0.549 kg/Rm) for shutter and 16.50 mm x 14.50 mm x 1.20 mm thk (wt. 0.157 kg/Rm) for glazing clip with 5 mm thick plain / frosted / tinted glass fixed in shutter including neoprene gasket, fixtures, fastenings and accessories like hinges, locking arrangement etc. complete as directed by Engineer In Charge. (Note: anodic film must not be less than 15 microns i.e. AC-15 as per IS, the anodizing must be scaleted by keeping the anodized section in boiling de-anodized water for a period of one hour)
7321st Floor
7332nd Floor
7343rd Floor
7354th Floor
7365th Floor
7376th Floor
7387th Floor
7398th Floor
7409th Floor
74110th Floor
74211th Floor
74312th Floor
74413th Floor
74514th Floor
74615th Floor
74716th Floor
74817th Floor
74918th Floor
75019th Floor
75120th Floor
75221st Floor
75322nd Floor
754Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating, fixtures, erecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complet Basement
755Ground Floor
7561st Floor
7572nd Floor
7583rd Floor
7594th Floor
7605th Floor
7616th Floor
7627th Floor
7638th Floor
7649th Floor
76510th Floor
76611th Floor
76712th Floor
76813th Floor
76914th Floor
77015th Floor
77116th Floor
77217th Floor
77318th Floor
77419th Floor
77520th Floor
77621st Floor
77722nd Floor
778Providing and fixing mild steel grill railing weighing 20Kilogram/ One Square Metre. with PVC handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing PVC handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, etc. complete. Spec. One Number : As directed by Engineer in charge.5th Floor
7796th Floor
7807th Floor
7818th Floor
7829th Floor
78310th Floor
78411th Floor
78512th Floor
78613th Floor
78714th Floor
78815th Floor
78916th Floor
79017th Floor
79118th Floor
79219th Floor
79320th Floor
79421st Floor
79522nd Floor
796Providing and fixing Modular false ceiling of 600 x 600 mm center to center and 13 mm thick square mineral fiber board to be fixed on frame work of aluminum sections for suspended false ceiling consisting of aluminum T 2”x1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/m at 60 cms center to center and fixed with ½” x ½” (15 x 15 mm) flanges weighing 0.19 Kilogram/m suspended on 6 mm dia mild steel rod weighing 0.22 Kilogram/m, fixed on wall and beams including rounding of the edges with aluminum T of 2” x 1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/m etc. (all aluminum sections shall be anodized) including all labour, material, lifts etc. complete.
7973rd Floor
7984th Floor
7995th Floor
8006th Floor
8017th Floor
8028th Floor
8039th Floor
80410th Floor
80511th Floor
80612th Floor
80713th Floor
80814th Floor
80915th Floor
81016th Floor
81117th Floor
81218th Floor
81319th Floor
81420th Floor
81521st Floor
81622nd Floor
817Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed /fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600-millimeter perimeter channel and intermediate channels at maximum center to center distance 1200-millimeter galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200-millimeter item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
8181st Floor
8193rd Floor
8204th Floor
8215th Floor
8226th Floor
8237th Floor
8248th Floor
8259th Floor
82610th Floor
82711th Floor
82812th Floor
82913th Floor
83014th Floor
83115th Floor
83216th Floor
83317th Floor
83418th Floor
83519th Floor
83620th Floor
83721st Floor
83822nd Floor
839Providing and fixing in position after hoisting ,precast1:2 cement mortar reinforced jali 50mm thic kwith 3mm diameter mild steel bar reinforcement, of approved design on both side, fixing in cement mortar 1:3 and curing etc. complete 5th Floor
8406th Floor
8417th Floor
8428th Floor
8439th Floor
84410th Floor
84511th Floor
84612th Floor
84713th Floor
84814th Floor
84915th Floor
85016th Floor
85117th Floor
85218th Floor
85319th Floor
85420th Floor
85521st Floor
85622nd Floor
857Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength,thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine fine aggregate (natural sand/crushed sand VSI grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and complete as per manufacturer spsecifications & direction of Engineer-in-Charge. 60mm thick CC paver block of M-35 grade concrete with approved colour and design & pattern.
858Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 80MM thick in M-40 grade of approved size and shape for City streets, small /medium market roads,low volume roads, utility cuts on arterial roads etc. as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of natural sand / crushed sand of 50 mm thickness including necessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete.
859Providing and fixing European type Colour glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 liter enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete. ( prior approval of sample and brand by Ex. Engineer is necessary before use) ( S. S. R. 2022-2023 I. No. 43.21 & Page No. 289 )
860Providing and fixing coloured glazed earthenware Wash Hand Basin of 63 cm x 45 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including chromium plated coupling bottle - Trap, P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565 ( S. S. R. 2022-2023 I. No. 41.65 & Page No. 272 )
861Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (S. S. R. 2022-2023 Material Rate Sr. No. 234 & Page No. 536)
862Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge. ( S. S. R. 2022-2023 I. No. 42.80 & Page No. 282)
863Providing and fixing C.P.pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. ( S. S. R. 2022-23 I. No. 42.82 & Page No. 282)
864Providing and fixing C.P. Toilet paper holder jaquar make continental (Cat. No. AQ 7751 ) including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. 2022-2023 Material Rate Sr. No. 232 & Page No. 536)
865Providing and fixing 450mm x 550mm size Superior Type Belgium Mirror with 16mm dia.nickel plated towel rod etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. 2022-2023 I. No. 42.20 & Page No.276)
866Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge. ( S. S. R. 2020-2023 I. No. 42.79 & Page No. 282)
867Providing and fixing C.P. sink cock with raised J\\" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete. Spec. No. As Directed By Engineer In Charge. ( S. S. R. 2022-2023 I. No. 42.84 & Page No. 283)
868Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No. As Directed By Engineer In Charge. ( S. S. R. 2022-2023 I. No. 42.83 & Page No. 283)
869Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No. As Directed By Engineer In Charge. ( S. S. R. 2022-2023 I. No. 42.31 & Page No. 277
870Providing and fixing Soap dish hooker jaquar including all accessories complete. Spec. No. As Directed By Engineer In Charge. ( S. S. R. 2022-2023 Material Rate Sr. No. 230 & Page No. 536)
871Grabbars - Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below. ( 1nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set ) 27 a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR-700mm and of DIA : 32MM and thickness 1.5 mm of the roved brand and make. 27 b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of I Z E -600MM (H) X 600MM (D) and 32MM DIA. and thickness mm of the approved brand and make. 27 c) Straight grab bar (2 NOS) Providing S. STEEL 304 GRAB RAIL (600MM), 32MM DIA. and thickness 1.5mm of the approved brand and make. (S. S. R. 2022-2023 I. No. 51.89 & Page No. 373)
872Providing and fixing coloured glazed earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap brackets for fixing the cistern 32mm dia. P.V.C. flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connection up to the outside face of the wall. (S. S. R. 2022-2023 I. No. 41.59 & Page No. 271)
873Providing, fixing, testing & commissioning of Automatic sensor for urinal with 15 mm dia control cock, C.P. brass flush pipe, nuts, vaccum breaker set with coupling nut, clamp and screws, C.P. spreader and wall flange including complete connection to urinal complete as required. (NON SSR)
874For Urinal's Sensors 1.5 sq.mm and 3 core concleaded wiring shall be provided with all necessary works. (Lumpsum length) (NON SSR)
875Providing and fixing solid state, no touch operating, fully hygienic hand dryer of approved shade with single blower, with time delay, summer & winter control, music while drying, volume ON/OFF controls including providing necessary brackets, cable from drier to Plug, Plug top key and lock etc, complete as required. (NON SSR)
876Providing and fixing solid state, no touch operating, fully hygienic hand dryer of approved shade with single blower, with time delay, summer & winter control, music while drying, volume ON/OFF controls including providing necessary brackets, cable from drier to Plug, Plug top key and lock etc, complete as required. (NON SSR)
877Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge ( S. S. R. 2022-2023 I. No. 42.55 & Page No. 280)
878Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge ( S. S. R. 2022-2023 I. No. 42.56 & Page No. 280)
879Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge ( S. S. R. 2022-2023 I. No. 42.57 & Page No. 280)
880Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge ( S. S. R. 2022-2023 I. No. 42.58 & Page No. 280)
881Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge ( S. S. R. 2022-2023 I. No. 42.58 & Page No. 280)
882Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge ( S. S. R. 2022-2023 I. No. 42.60 & Page No. 280)
883Providing and fixing G.I. Pipe 65mm dia. Heavy type (ExcludingGST) SSR 2022-23 SR. No. 16 & Page No. 532)
884Providing and fixing G.I. Pipe 80mm dia. Heavy type (ExcludingGST) SSR 2022-23 SR. No. 18 & Page No. 532)
885Providing and fixing G.I. Pipe 100mm dia. Heavy type (ExcludingGST) SSR 2022-23 SR. No. 2 & Page No. 532)
886Providing and fixing Ductile iron manhole cover of light/medium/heavy duty with frame of any size over inspection chamber etc. complete (Prior permission of S.E. is to be obtained before inclusion of this item in the estimate) Spec. No. As directed by Engineer in charge ( S. S. R. 2022-2023 I. No. 50.30 & Page No. 336)
887Providing & fixing Ball cock for 15mm dia (ExcludingGST) NON SSR )
888Providing & fixing Ball cock for 20mm dia (ExcludingGST) NON SSR )
889Providing & fixing Ball cock for 25mm dia (ExcludingGST) SSR 2022-23 SR. No. 290 & Page No. 537)
890Providing & fixing Ball cock for 32mm dia (ExcludingGST) SSR 2022-23 SR. No. 291 & Page No. 537)
891Providing & fixing Ball cock for 40mm dia (ExcludingGST) SSR 2022-23 SR. No. 292 & Page No. 537
892Providing & fixing Ball valves for 50mm dia (ExcludingGST) SSR 2022-23 SR. No. 294 & Page No. 538
893Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV ( C. S. R. 2022-2023 ITEM NO 13-7-18)
894Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV ( C. S. R. 2022-2023 ITEM NO 13-7-19)
895Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV ( C. S. R. 2022-2023 ITEM NO 13-7-19)
896Supplying, Fixing & Testing Pressure reducing Valve Bronze compact approved make with strainer and cleanning assembly and with necessary connectors.(NON SSR) PRV for 25mm Di
897PRV for 32mm Di
898PRV for 50mm Di
899Supply,installation,testing and commissioning of Heavy quality Y-strainer with blowdown with PN 16 GM body & SS jali / mesh 0.8 mm perforation size including all accessories. including built-in ball valve (screwed/ flanged flanges and nuts and bolts etc .(NON SSR) 80mm Di
900100mm Di
901OHT LEVEL CONTROL SYSTEM - SOLENOID VALVE - IP55CB - 24VAC Pilot Operated / slow closing Diaphragm Type Solenoid Valve Screwed end with IP 65 Coil and Manual Override. (below 40 mm) / (40mm and above ) Motorized operated BUTTERFLY VALVE - IP55CB-23 0VAC On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type with CI Body & SS Disc. (including Y-Strainer, Level Float Switch with 5Mtr cable length, with bypass arrangement, necessary accessories)CONTROL BOX FOR OHTIP 55 LED Lamps, (Tank Full, Tank Empty, power) Power supply toggle switch, Accepts 230V Single Phase power supply and provides 24VAC to float switch and 24VAC to valve coil / 230V AC 2 valve. Accepts NO/NC feedback from float switch.(NON SSR) 65mm Di
90280mm Di
903Providing and fixing floor trap connection 75mm diameter unplasticized polyvinyl chloride (UPVC) ultra violet stabilized deep seal Nahani trap including PVC grating confirming to IS 4985, rubber plug and piece of PVC pipes of suitable diameter and length upto outside face of wall and making all joints water tight with providing rubber socketed packing and sealing with suitable and durable water tight resins and making holes in masonry / concrete, redoing the same with cement mortar 1:4 and curing etc. complete. As directed by Engineer in charge. ( NON SSR)
904Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) complete Spec. No. Specfications ( S. S. R. 2022-2023 I. No. 43.18 & Page No. 288)
905Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete Spec. No. As directed by Engineer in charge ( S. S. R. 2022-23 I. No. 42.51 & Page No. 279)
906Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec. No. As directed by Engineer in charge. ( S. S. R. 2022-2023 I. No. 42.52 & Page No. 279)
907Providing & fixing P.V.C.pipe 160mm dia.Soil Pipe (Excluding GST) SSR 2022-23 SR. No. 292 & Page No. 537
908Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592- 1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Spec. No. As directed by Engineer in charge ( S. S. R. 2022-2023 I. No. 42.85 & Page No. 283)
909Providing and fixing PVC Pipe of Standard Length, the wall thickness of P.V.C pipe confirm to IS-4985-2000 Of 10 Kg / Sqcm (Class-3). This shall include connection from fixtures to floor trap, all fittings, supports from wall/ceiling, clamps & hangers cutting & making good the walls & floor where ever required. Jointing complete with PVC solvent cement. (S. S. R. 2020-2023 Material Rate Sr. No. 180 & Page No. 535)P.V.C. pipe 40mm dia.10kg/cm2 pressure(class IV)
910Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete (S. S. R. 2017-18 I. No. 43.25 & Page No. 361) ( S. S. R. 2022-2023 I. No. 43.25 & Page No. 290)
911Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical MeansSpec.No. : Bd.A.3, Page No. 259. ( S. S. R. 2022-2023 I. No. 21.10 & Page No. 154)
912Filling in plinth and floors with approved excavated material in 15cm.to 20cm. layers including watering and compacting etc. complete. Spec. No Bd.A.10 Page No. 262 ( S. S. R. 2022-2023 I. No. 21.36 & Page No. 157)
913Providing and laying in trenches 100 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 12.43 kg/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. Bd.V.5 Page No. 551 ( S. S. R. 2022-2023 I. No. 41.25 & Page No. 269)
914Providing and fixing 100mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangements and lock. [Without chamber]. Spec. No. BD.V 7 Page 554 (S. S. R. 2022-2023 I. No. 41.25 & Page No. 269)
915Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge. Spec. No. As per directed by engineer In-charge (S. S. R. 2022-2023 I. No. 48.49 & Page No. 318)
916Providing & constructing Brick Masonry Inspection Chamber 60 Cm x 45 Cm x 90 Cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. lid 65 kg with frame fixed in cement concrete etc. complete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (S. S. R. 2022-2023 I. No. 42.12, P. No. 275 )
917Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical MeansSpec.No. : Bd.A.3, Page No. 259. (S. S. R. 2022-2023 I. No. 21.10 & P. No. 154)
918Excavation for Foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259. (S. S. R. 2022-2023 I. No. 21.14 & P. No. 154)
919Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete. Spec. No. Bd.A.10 Page No.262 (S. S. R. S.S.R. 2022-2023 I. No. 21.36 & P. No. 157)
920Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. (S. S. R. 2022-2023 I. No. 21.40 & P. No. 157)
921Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287 (S. S. R. 2022-2023 I. No. 24.01 & P. No. 175)
922Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.3 Page No. 298 and B.7, Page No.38 (S. S. R. 2022-2023 I. No. 25.13 & P. No. 178)
923Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.8 Page No. 302 and B.7, Page No.38 (S. S. R. 2022-2023 I. No. 25.72 & P. No. 182)
924Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 (S. S. R. 2022-2023 I. No. 26.19 & Page No. 231)
925Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No. Bd.F.17, Page No. 306 (S. S. R. 2022-2023 I. No. 26.33 & Page No. 188)
926Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Spec. No. Bd.G. 1. Page No. 313. (S. S. R. 2022-2023 I. No. 27.01 & Page No. 197)
927Providing Internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Spec. No. Bd.L. 2 Page No. 368 (S. S. R. 2022-23 I. No. 32.04 & Page No. 209)
928Providing Fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Spec.No. : As Directed By Engineer In Charge. (S. S. R. 2018-19 I. No. 32.21 & Page No. 262)
929Providing and Fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Spec. No. Bd.C.2 Page No. 275 (S. S. R. 2022-2023 I. No. 23.01 & Page No. 173)
930Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (S. S. R. 2022-2023 I. No. 42.12, P. No. 275)
931Providing and constructing Ductile Iron circular manhole 45 cm dia. At top 90 cm at bottom up to 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concrete bedding 15 cm thick burnt brick mansonry with 1:1 cement mortar plaster 25 mm thick inside and outside 20 mm (1:3) ductile iron heavy type cover with ring 125 kg in weight. High strength. More life and Durability, Good Antiskid Grip, Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. with prior approval of concerned Superitending Engineer. Spec. No. As directed by Engineer-in-charge (S. S. R. 2022-2023 I. No. 50.31, P. No. 337)
932Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. Spec. No. As Directected By Engineer Incharge (S. S. R. 2022-2023 I. No. 43.31 & Page No. 291)
933Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. Spec. No. As Directected By Engineer Incharge (S. S. R. 2022-2023 I. No. 43.32 & Page No. 363)
934Providing and constructing Brick Masonry Inspection Chamber 45cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (NON.S. S. R)
935Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP (Electrical SSR 12-3-1)
936Supplying & erecting minimum three & above star rated Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C. supply of 5.625 KW/7.5 HP with discharge of 780/170 Litres per Minute (LPM) for head of 33/54 m and 80mm suction/ 65mm delivery pipe of size, on provided C.C. foundation as per specification No. WP-CGP (Electrical SSR 12-1-10)Supply, installation, testing and commissioning of monoblock Transfer type centrifugal pumps comprising a) Control Starter Panel with autochange over and BMS conectivity with on off status.b) All accessories required for the control of system as per control scheme.c) All interconnection piping,pressure gauges with isolation valve, flexible connectors etc., as shown in the drawing and as required.d) Electrical connection to pumps from panel using suitable con ductors and earthing of equipment. e) Water Lvl sensers , etc..f) Required cabling with terminations etc g) Guide Rail & chain for pulling the pumps h) Auto change over mechanism with control panel for 1+1 configuration
937Transfer system for domestic water supply as per the Pump Data Sheet-DWP1 (NON CSR)
938Transfer system for flushing water supply as per the Pump Data Sheet-FWP1 (NON CSR)
939Hydropneumatic system for domestic water supply as per the Pump Data Sheet-BDWP1 (NON CSR)
940Providing and fixing WTP 13,000 LPH
941Basic Test of Cement Standard Consistancy, Fineness, Specific Gravity, setting time (Intinal & Final), Compressive Strength, Soundness.
942Basic Test of AggregateWater absorption,Specific Gravity,Impact value, Crushing value
943Sieve Analysis
944Flakiness Index
945Fine AggregateFiness Modulus
946BricksWater Absorption, (Set of 5 Bricks), Compressive Strength (Set of 5 Bricks), Efflorescence (Set of 5 Bricks).
947Ceramic Tiles & Vitrified Tiles Water Absorption, Modulus of Rupture (Set of 6 Tiles).
948Concrete Compressive Strength of C.C Cube (Set of 3 Cubes).
949Conrete Mix Design (With all Testes on basic material).
950MortorCompressive Strength (Set of 3 Cubes)
951Stone / Rubble Crushing Value / Compressive Strength,Water Absorption, Specific Gravity.
952Soil / Murum Liquid limit & Plastic Limit.
953Soil / Murum Compaction Test (Proctor Density).
954Aluminium Section Thickness , Mass per running meter.
955Water PH Value, Sulphate & Chloride Content.
956Wood Density, Moisture Content.
957Flush Door Knife Test, Adhesion test, end immersion Test.
958Steel Bar Testing Upto 16 mm (Set of 3 bars)
959Above 16 mm (Set of 3 bars) (Tensile strength % Elongation, Yield Stress, Weight -per meter, Bend / Rebend test, proof stress.)
960Non - Destructive Test Rebound Hammer Test
961Non - Destructive Test Ultrasonic Pulse velocity
962Royalty Charges sand
963Royalty Charges Other than Sand
964Supplying, erecting, testing and commissioning of diesel generating set with alternator of 500 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 81.90 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 690 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
965Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, 1000A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s),with standard accessories with ready to close indication, individual fault trip indication, indications for alarm and trip, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCDdisplay release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB
966Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides,with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note: 18563 x 20%= 3712.6 ie 18563 + 3712.6 = 22275.6
967Providing & erecting 3 Pole MCCB 415V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCBNote: 25327 x 20%= 5065.4 ie 25327 + 5065.4 = 30392.4
968Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCBNote: 10604 x 20%= 2120.8 ie 10604 + 2120.8 = 12724.8
969Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specificationno. SW-SWR/MCCBNote: 5309 x 20%= 1061.8 ie 6309 + 1061.8 = 6370.8
970Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
971Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
972Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
973Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
974Supplying and erecting intelligent flush mounted maximum demandcontroller panel meter three phase four wire 50-550 V Phase to phase aux supply 90-300V AC/DC CT secondary site selectable 1A/5A, class I flush mounted 96 x 96 mm meter, data log 8 MB, 4 real output time of day (TOD) 6 slots available, block / sliding window site selectable with V, A, F, kW, kVA, kVAr, kWh, kVAh, kVArh, PF, run hr, ON hrs, Intr, phase angle, THD, events, neutral current, max demand (with RTC) viewing in LCD multi-function meter with LCD display complete class -I accuracy with RS 485 communication protocol with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
975Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
976Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 630A having 50mm (Width) X 10 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB
977Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 400A having 50mm (Width) X 5 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB
978Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 200A having 25mm (Width) X 5 mm (Thickness) , with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB
979Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB
980Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
981Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
982Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
983Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 315A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6
984Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 100-125A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
985Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
986Supplying & erecting Fully Automatic Star/delta starter suitable for above 25 H.P. up to 35 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame.
987Supplying & erecting Fully Automatic Star/delta starter suitable for 12.5 H.P to 15 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame.
988Supplying and erecting pump protection relay comprising current sensing phase failure and UV+OV relay with dry run and overload protection suitable for 3 phase pumps.
989Supplying and erecting 50 kVAr, 3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC
990Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
991Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400 A, 6 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
992Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
993Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specificationno. SW-SWR/MCCB Note: 5309 x 20%= 1061.8 ie 5309 + 1061.8 = 6370.8
994Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP BB
995Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
996Supplying erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board complete.
997Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB / RCCB / RCBO complete erected on angle iron/GI frame.
998Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
999Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW Note - 3) Rates for the earth wire shall be calculated as one half rate of mains of bunch of two wire.
1000Supplying and erecting 25 mm dia. corrugated flexible polypropyleneconduit.
1001Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
1002Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1003Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP BB
1004Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010
1005Supplying and erecting static energy Trivector meter 440 V 50 Hz. 20-100A ISI mark meter AC 3 phase 4 wires LCD/LED display (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested for class 1.0 accuracy by electric supply company.
1006Supplying and erecting static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proofPVC wires duly tested by electric supply company.
1007Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
1008Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
1009Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
1010Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
1011Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
1012Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1013Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1014Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
1015Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
1016Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1017Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1018Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1019Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1020Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1021Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1022Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1023Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1024Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1025Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1026Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1027Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1028Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1029Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 240 to 300 sq mm., with necessary material as per specification no. CB-JT/LT
1030Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 150 to 185 sq mm., with necessary material as per specification No. CB-JT/LT
1031Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 70 to 120 sq mm., with necessary material as per specification No. CB-JT/LT
1032Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sq mm., with necessary material as per specification No. CB-JT/LT
1033Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification No. CB-JT/LT
1034Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware.
1035Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
1036Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / woodenboard with 3 years warranty.
1037Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
1038Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVCBlock / wooden board with 3 years warranty.
1039Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
1040Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,Complete
1041Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1042Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW Note - 3) Rates for the earth wire shall be calculated as one half rate of mains of bunch of two wire.
1043Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WGPW/ SW.
1044Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
1045Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW
1046Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
1047Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
1048Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
1049Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
1050Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
1051Supplying & erecting 4 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
1052Supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
1053Supplying & erecting 100 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW
1054Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG- 11 as per specification No. WG-TW
1055Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG- 6 as per specification No. WG-TW
1056Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
1057Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
1058Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
1059Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.
1060Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall with insulating and non-corrosive bond with required joints. As per specification no. EA-EP.
1061Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protectionsas per specification no. AP-UPS
1062Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
1063Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
1064Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
1065Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.
1066Providing and back filling ground enhancing compound 25 kg bag complete
1067Supplying, installing, testing and commissioning of 10 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 30 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 years including net chargesfor RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG
1068Supplying and erecting AC three phase LT CT multifunction net meterDLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
1069Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU.
1070Supplying, erecting and marking triple pole isolators only switch version of miniature circuit breaker of 100A with required wiring connections and lugs etc. in provided distribution board.
1071Supplying, erecting, testing and commissioning of 10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) having minimum IK08/IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming and 3 nos. output as per IEC 60309 industrial sockets having capacity of output current of 16A 240V AC at each socket with 3.5\\"TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 Coated M.S, Erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification.
1072Supply, Installation, Testing and Commissioning 7.2 kW AC Electric Vehicle charger (suitable for 4 wheeler) having minimum IK08 & IP54 protection suitable for single phase, 230V AC, 50Hz, incoming and 1 nos. output having capacity of output current of 32A at 230V with Type two connector as per IEC 62196-2 , Interlocking arrangement & minimum 5 meter charging cablelength, 3.5\\" TFT screen for human interface & LED light for status indication and metering for measurement of consumed energy having metering accuracy +/- 1%, one hour battery backup for server communication, emergency push stop button, with user interface by mobile application/QR Code/RIFD Card/Password Login and having short circuit, over & under voltage, overload,earth leakage ,Over temperature, surge protection and enclosure made of minimum 1.5mm duly RAL7035 coated M.S, erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification
1073Supplying & erecting Aviation obstruction light consisting of yellow painted die cast aluminium alloy housing with Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete.
1074Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
1075Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
1076Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982
1077Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
1078· Rated capacity :- 13 Passenger/884Kg ·Floors :- B+G+22 floor (24 Stops/24 Landings) · Travel :- 75 mtrs. · Location of Lift Machine:- MR · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 900/1000 mm wide x 2000 mmhigh · Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters, The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves,suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting andhoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
1079Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
1080Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1081Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
1082Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
1083Supplying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
1084SITC of IP Dome/ Bullet CameraSupply Installation commissioning of 4 MP Full HD IP Dome/Bullet Camera Image SenCSR 1/3\\" 4 megapixel progressivescan CMOS Effective Pixels 2304 (H) X 1296 (V)Electronic Shutter Speed 1-1/100000 s Min. Illumination0.5 lux F2.1 (Color); 0 lux (IR LEDs on IR Distance - nUp to 100 ft(30 m) Day/Night -auto (ICR)/Color/BW Backlight Compensation BLC/HLC/DWDR White Balance - Auto/Manual Gain Control - Auto/Manual Noise Reduction - 3D Privacy Masking - Up to 4 areas Lens Focal Length - 2.8mm Horizontal Angle of View 92° 86°-28 CompressionH.265 (Main/High/Baseline Profile) /JPEG Resolution 3 MP(2304x1296) 1080p Main Stream 4 MP ,30 fps 16x Digital zoom 60 fps, Resolution- Verifocal lens, 320 db Corridor Mode Support Network Protocol IPv4/IPV6 HTTP HTTPS CP/IP UDP UPnP ICMP IGMP RTSP RTP SMTP NTP DHCPDNS PPPOE DDNS FTP IP Filter QoS Compatibility - nONVIF Profile SCGI Max. User Access 20 users Mobile App for iPhone iPad Android Phone and Tablet Power Supply PoE (802.3af)12 V DC Working Environment -22°F to 140°F (-30°C to 60°C); 10% to 100% RH condensing ngress
1085SITC of Network Video RecorderSupplying and erecting Supplying, erecting, testing & commissioning of NVR 64 Channel professional series 4K HD Network Video Server Processor Industrial embedded micro-processor Operating System : LINUX Two-way Talk: 1channel Input, 1 channel Output, RCA Video Output : 1 HDMI, 1 VGA Video Resolution 3840×2160,1920×1080,1280x1024, 1280x720, 1024×768 Channel : 64channel Bandwidth Incoming Max. 200Mbps Incoming and 96Mbpsoutgoing bandwidth Motion Detection : MD Zones: 396(22×18). Alarm Input 16 Channel, Low Level Effective, Green Terminal Interface Alarm Output 4 Channel, NO/NC Programmable, Green Terminal Interface Smart Phone:iPhone, iPad, Android Phone Hard Disk : 8 SATA III ports, up to 10TB Each Trigger Events : Recording, PTZ, Tour,Alarm out, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips Recording Mode Manual, Schedule (Regular,Continuous), MD (Video detection: Motion Detection, Tampering, Video Loss), Stop Search Mode:Time/Date,Alarm, MD & Exact search (accurate to second), Smart search Backup Mode : USB Device/Network Playback: Play, Pause, Stop, Rewind, Fast play, Slow play, Next file, Previous file, Next camera, Previous camera, Full screen, Repeat, Shuffle, Backup selection, Digital zoomMax User Account : 128 users Record Interval 1~120 min (default: 60
1086SITC of 8 TB Surveillance Hard Disk ciard disc product dimensions 10.2 x 2.5 x 15.2 cm item mode nuymber ST4000VX007 memory Storage capacitry 4 TB Flash Memory installed Size 4 TB Digital Storage Capacity 4 TB Hard Drive Rotation Sppeed 5900 RPM Survillance DVRs Hardware Interface SATA 6.0 gB/s Graphics Card Interface PCI-E Compatible Devices Desktop Buffer Size 64 MB(NON-CSR).
1087Supplying, Erecting, Testing & Commissioning of Full HD commercial display DISPLAY-Screen Size 55-inch Aspect Ratio 16:9 Backlight Scanning 100Hz Resolution 1920x 1080 pixels Viewing Angle178° /178° TERMINAL- VIDEO IN RCA X1 AUDIO IN (L/R) RCA Pin Type X 2 HDMI IN HDMI 1.4 X3 USB Input USB 2.0 X 2 RS232C Yes HDMI CEC Yes VGA IN Yes PC AUDIO IN Yes (1) (Share with AC) (NON- CSR).
1088Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
1089SITC of cat-6 UTP cable with all necessary accessories as required in 25mm dia black enamelled MMS PVC conduit surface conduit/recessed Hard 2mm thick PVC conduit with all accessories.
1090SITC & termination of RJ45 CONNECTOR
1091Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1092Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW Note - 3) Rates for the earth wire shall be calculated as one half rate of mains of bunch of two wire.
1093Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
1094LIGHT Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
1095Secondary point wiring for additional light/ bell point in PVC trunking(casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
1096FAN Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
1097BELL Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WGPW/ SW
1098Wiring for plug on board with flush Switch socket, copper wiring and earthing as per specification No:WG-PW/SW
1099Supplying and erecting flush, shock proof plug socket 6 pin 6A and 16A with switch 16A combined unit erected in recess in 16 gauge M.S sheet box duly painted and connected with earth terminal and leads
1100Point wiring for independent plug in PVC trunking (casingcapping) with 1.5 sq.mm FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
1101Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
1102Supplying and erecting PVC trunking (PVC casing-n-capping) of size 20 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1103Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1104Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 3) Rates for the earth wire shall be calculated as one half rate of mains of bunch of two wire.
1105Supplying and erecting ISI mark modular type T.V. Socket single outlet, duly erected on provided plate and box with wiring connections complete.
1106Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1107Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW Note - 3) Rates for the earth wire shall be calculated as one half rate of mains of bunch of two wire.
1108Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
1109LIGHT Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
1110Secondary point wiring for additional light/ bell point in PVC trunking(casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
1111FAN Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
1112Wiring for plug on board with flush Switch socket, copper wiring and earthing as per specification No:WG-PW/SW
1113Supplying and erecting flush, shock proof plug socket 6 pin 6A and 16A with switch 16A combined unit erected in recess in 16 gauge M.S sheet box duly painted and connected with earth terminal and leads
1114Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
1115Supplying and erecting PVC trunking (PVC casing-n-capping) of size 20 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1116Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1117Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 3) Rates for the earth wire shall be calculated as one half rate of mains of bunch of two wire.
1118Supplying & erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
1119Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
1120Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specificationno. SW-SWR/MCCB Note: 5309 x 20%= 1061.8 ie 5309 + 1061.8 = 6370.8
1121Supplying, fixing and commissioning 4 pole RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO
1122Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP (FOR TRANFER OF RAIN WATER)
1123Supplying & erecting Fully Automatic Star/delta starter suitable for 12.5 H.P to 15 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame.
1124Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P. (FOR TRANFER OF RAIN WATER)
1125Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/BP
1126Supplying, installation, testing and commissioning of main fire pump(MFP /EP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 75kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
1127Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
1128Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 110 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 11 kW or ofsuitable kW capacity for manual/automatic operation and consisting of following:(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/JP
1129Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
1130Supplying and installing G.I. pipe above ground of ‘C’ class ERW conforming to IS: 1239, alongwith necessary fittings and M.S. angle iron supports, with one coat of red oxide primer and two coats of Post office fire red enamel paint, duly tested to 1.5 times of working pressure, in an approved manner.
1131Supplying and erecting G.I.pipe above ground of ‘C’ class ERW of size 75/80 mm dia. with necessary fittings complete as per specification No. FF-PP
1132Supplying and erecting G.I.pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings complete as per specification no.FF-PP
1133Supplying and installing G.I.pipe underground of ‘C’ class ERW conforming to IS: 1239, alongwith necessary fittings and excavation upto 1000mm in all type of soil and backfilling the excavated stuff in 3 layers, compacting the soil and disposing the surplus soil within a lead of 100m including wrapping of 2mm thick PYPKOTE insulation with adhesive coat duly tested to 1.5 times of working pressure, in an approved manner.
1134Supplying and erecting G.I.pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings complete as per specification no.FF-PP
1135Supplying and installing cast iron foot valve ball type / flap type of size150 mm dia with strainer for negative suction as per specification No.FF-VL/FV
1136Supplying and installing cast iron Butterfly valve with EPDM rubber gasket conforming to IS:5312 (Part-I) PN1.6 with nut bolts, gaskets etc. and tested to1.5 times of working pressure, in an approved manner.
1137Supplying & Installing cast iron double flange butterfly valve of size 75/80 mm dia. as per specification No. FF-VL/BFV
1138Supplying & Installing cast iron double flange butterfly valve of size 100 mm dia. as per specification No. FF-VL/BFV
1139Supplying & Installing cast iron double flange butterfly valve of size 150 mm dia. as per specification No. FF-VL/BFV
1140Supplying & erecting cast iron double flange butterfly valve of size200 mm dia. complete as per specification no. FF-VL/BFV
1141Supplying and installing 'Y' strainer fabricated out of brass perforated sheet of 14 SWG (2.0 mm thick) duly with brazing to flange or pipe with nut bolts, gaskets, washers, etc. in position for only suction in an approved manner.
1142Supplying and installing 100 mm dia end line straine + ve suction complete as per specification No. FF-VL/ELS
1143Supplying and installing 200 mm dia end line straine + ve suction complete as per specification No. FF-VL/ELS
1144Supplying and installing double flange NRV conforming to IS:5312 (Part-I), ISI marks, PN1.6 having cast iron body and gun metal working parts with nut bolts, gaskets, etc. and tested to 1.5 times of working pressure in an approved manner.
1145Supplying and erecting cast iron double flange NRV of size 75 / 80 mm dia complete as per specification No. FF-VL/NRV
1146Supplying and erecting cast iron double flange NRV of size 150 mm dia complete as per specification No. FF-VL/NRV
1147Supplying & erecting gun metal gate valve of size 25 mm dia as per specification No. FF-VL/GV
1148Supplying & installing One piece moulded HDP / Fibre water tank.for -ve suction only, having capacity 1000 ltrs.fitted with necessary accessories complete as per specification No.FF-FFA/PT
1149Supplying and installing gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification No. FF-VL/HV
1150Supplying gunmetal double outlet hydrant valve fittedwith necessary accessories complete as per specification no. FF-VL/HV
1151Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
1152Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m high pressure polypropylene (Polyhose) long fitted with necessary accessories complete as per specification No. FF-FFA/HV
1153Supplying fire fighting C.P. (controlled percolation) Hose pipe, 63mm dia, 15min length, fitted with necessary accessories complete as per specification no. FF-FFA/CPH
1154Supplying Stainless Steel branch Pipe 63 mm Ø fitted with 20 mm dia detachable hexagonal nozzle as per specifications No. FF-FFA/NZ
1155Supplying and installing Air Vessel of 300 mm Ø 1.5m in height M.S. tank installed inside pump house as per specification No. FF-FFA/ACT
1156Supplying and erecting 20 / 25mm Ø G.M.air release cock, with necessary G.I. coupling to be fitted on top of Air vesselor on wet riser as per specification No.FF-FFA/ARV
1157Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm Ø. Pad cock valve, and G.I. pipe, elbow etc. as per requirement in an approved manner as per specification No. FF-FFA/PG
1158Supplying and installing pressure switch with 12/15 mm Ø isolation valve, G.I. nipple, elbow etc. in an approved manner as per specification No. FF-FFA/PS
1159Supplying and erecting one no. Brass orifice plate having 6 mm. thickness, 140 mm outer dia and required/proper diameter of inner hole at every single outlet hydrant valve as per specification No. FF-FFA/OP
1160Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
1161Supplying and installing fire brigade Header of 150 mm Ø, for supplying water in fire tank as per specification No. FFFA/FBC
1162Supplying and installing fire brigade Header (Siamese Connection) of 150 mm Ø for supplying water to wet riser system as per specification No. FF-FFA/SMC
1163Supplying and erecting 100 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
1164Supplying and installing G.I.pipe of ‘C’ class ERW conforming to IS: 1239, alongwith necessary fittings and M.S. angle iron supports or GI threaded U clamps, pipe supports with one coat of red oxide primer and two coats of Post office fire red enamel paint, duly tested to 1.5 times of working pressure, in an approved manner.
1165Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 25 mm dia with necessary fittings as per specification no.FF-PP
1166Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 32 mm dia with necessary fittings as per specification no.FF-PP
1167Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 40 mm dia with necessary fittings as per specification no.FF-PP
1168Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 50 mm dia with necessary fittings as per specification no.FF-PP
1169Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 65 mm dia with necessary fittings complete as per specification no. FF-PP
1170Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 75 / 80 mm dia with necessary fittings as per specification no.FF-PP
1171Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings as per specification no.FF-PP
1172Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings as per specification no.FF-PP
1173Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 200 mm dia with necessary fittings as per specification no.FF-PP
1174Supplying and erecting, testing and commissioning of 15 mm (½\\") dia. NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction as per specification No. FF-SPR
1175Supplying & erecting, testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 100 mm dia having following features 1) Visual Switch Activation 2) Rugged Switch Assembly 3) Heavy Duty Alluminium pipe Saddles 4) Durable Metal Encloser 5) Steel U Bolts For Secure Mounting 6) Two SPDT ( Single Pole Double Track ) Synchronised Switches 7) Serviceable Without Draining Pipes
1176Providing Round bottom FIRE Bucket of 9 Litrescapacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
1177Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
1178Supplying and erecting D.C.P. type Fire Extinguisher 9 kg capacity cartridge type with Gun Metal cap 150 gram CO2 gascartridge, powder and brackets conforming to IS 2171-1985and complete erected with necessary clamps made from 50x6mm M.S. flat with nuts & bolts grouted in wall complete.
1179Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clampfor erection on wall
1180Supplying and erecting Fire resistant Mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings with all kinds of cables, pipes and cable support system in steel and aluminium and plastic profiles ( Except hollow core conductors). The residual openings shall be closed with filler, as per specification No. FF-FRM
1181Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
1182Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
1183Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300μA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF- AFAS/SD
1184Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistorcomplete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD
1185Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \\"Break Glass\\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
1186Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
1187Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
1188Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relaysFF-AFAS/ISM
1189Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH
1190Supply, installation and testing & comminssioning of Fire fighter's telephone jack with suitable interface module complete with required mountings.
1191Supply, installation and testing & comminssioning of gas detector Rate of Rise Cum Fixed temperature detector , complete with MS Powder coated Junction Box for mouting on Surface / on False Ceiling / Below False Floor.
1192Supplying, erecting, testing and commissioning vane type water flow detector75/80 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3)Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches7) serviceable without draining pipes
1193Supplying, installing, testing and commissioning FR, XLPE armoured cable 2core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
1194Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
1195Supplying, erecting, testing and commissioning 15 to 30 Watts soundcolumn or ceiling mounted complete as per specification no. FF-A/SOC
1196Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367mm) as per specification No. WG-NAS/RAK
1197Supplying, erecting, testing and commissioning rust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete.
1198Supplying, erecting, testing and commissioning stand mounted / handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
1199Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
1200Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
1201Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. (red lead paints & 2coats of enamel paint nor required. fabrication for recturangular duct not for panel boxes)
1202Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paintteel(red lead paints & 2coats of enamel paint nor required. fabrication for recturangular duct not for panel boxes)
1203Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.(red lead paints & 2coats of enamel paint nor required. fabrication for recturangular duct not for panel boxes)
1204Supplying and fixing wire mesh (Jali) cover suitable for fitting / fan or for any purpose, complete with necessary materials. The jali cover shall be made from good quality G.I. wire mesh size 25 x 25 (mm) and made up of 14 SWG G.I. wire with side / supporting MS strips of suitable size.
1205Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.Flexible Duct
1206Inter Connecting Flexible Circular Ducting dia 150mm
1207Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.
1208Circular Exhaust Air Disc Valve in Plastic Construction suitable for Toilet Exhaust with VCD
1209Supplying and installing of collar damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of suitable size.
1210Lift Core Pressurization Fan - Tube Axial Type Direct Drive with Motor having capacity of :suitable for 250 deg. C X 2 Hrs Rating 32000 CFM Vs 40 mm swg
1211Exhaust Air Fan - Tube Axial Type Direct Drive with Motor(Car Park ) having capacity of :suitable for 250 deg. C X 2 Hrs Rating11500 CFM Vs 20 mm swg
1212Fresh Air Fan - Tube Axial Type Direct Drive with Motor(Car Park ) having capacity of :suitable for 250 deg. C X 2 Hrs Rating11500 CFM Vs 20 mm swg
1213Exhaust Air Fan - Tube Axial Type Direct Drive with Motor(,PUMP RM ) having capacity of :suitable for 250 deg. C X 2 Hrs Rating4000 CFM Vs 20 mm swg
1214Fresh Air Tube axial fan (FOR PUMP Room )CFM-3500 MODE - Normal TOTAL STATIC-20 mm W.G
1215Lift Lobby Pressurization FanCFM-5000 MODE - Fire TOTAL STATIC-1.2In W.G
1216Staircase Pressurization Fan CFM-5000MODE - Fire TOTAL STATIC-1.2In W.G
1217Exhaust Air - Jet Fan (Car Park ) :suitable for 250 deg. C X 2 Hrs Rating 2750 CFM Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55999522
AUTHORITY Government Departments
TENDER VALUE 58.36 Crore
LAST DATE 10-07-2026
Authority
Authority Name Shivshahi Punrvasan Prakalp Limited
Work Description Tender for Construction Of Sale Building No. S-34 Consisting Of 208 Tenements In The Slum Rehabilitation Scheme At Turbhe Mandale, Mankhurd
Basic Detail
Tender No 01/2026-27
Bidding Type Tender
Location
City Turbhe
State Maharashtra
Key Dates
Publish Date 02 Jul 2026
Submission Date 10 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 58.36 Crore
Tender Fee 3540
EMD 29.18 Lakhs
Exemption Not Available
Document List
721cacca-d0c1-4995-a278-bf875db7e8bf.html
BOQ_2245744.xls
DTDraftSPPL.pdf
Tendernotice_1 (21).pdf
Vol2DRAWINGLIST.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 10, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed

Tender Documents

Download All (ZIP) ↓
html

721cacca-d0c1-4995-a278-bf875db7e8bf.html

xls

BOQ_2245744.xls

pdf

DTDraftSPPL.pdf

pdf

Tendernotice_1 (21).pdf

pdf

Vol2DRAWINGLIST.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender