| 1 | SITC of Vertical Turbine Pump capacity 201 HP or 150KW suitable for 415V 50 HZ 3 Phase AC supply with discharge cap minimum 20 CUS or 2038 M3 per Hr with head 20 meter as per OEM recommendations | SITC of Vertical Turbine Pump capacity 201 HP or 150KW suitable for 415V 50 HZ 3 Phase AC supply with discharge cap minimum 20 CUS or 2038 M3 per Hr with head 20 meter as per OEM recommendations |
| 2 | Construction of RCC precast UG sump well of diameter 3.0 mtr along with RCC precast drain and MS framed structure with galvalume sheet complete as per Drg | Construction of RCC precast UG sump well of diameter 3.0 mtr along with RCC precast drain and MS framed structure with galvalume sheet complete as per Drg |
| 3 | SITC of Electrical control panel for 201 HP or 150 KW VT Pump set complete with starter VFP instrumentation and Control as per OEM recommendation of VT Pump all as specified and directed | SITC of Electrical control panel for 201 HP or 150 KW VT Pump set complete with starter VFP instrumentation and Control as per OEM recommendation of VT Pump all as specified and directed |
| 4 | SITC of feeder pillar box kiosk type CPRI approved with one no 630 Amp MCCB as Incoming and 02 Nos 320 Amps and 01 No 40 Amp etc complete all as per description | SITC of feeder pillar box kiosk type CPRI approved with one no 630 Amp MCCB as Incoming and 02 Nos 320 Amps and 01 No 40 Amp etc complete all as per description |
| 5 | Supply laying and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor of size 240 sq mm 3.5 core complete all as per description | Supply laying and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor of size 240 sq mm 3.5 core complete all as per description |
| 6 | Supply laying and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor of size 16 sq mm 4 core | Supply laying and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor of size 16 sq mm 4 core |
| 7 | SITC of Voltage stabilizer for automatic operation, three phase naturally oil cooled Outdoor type of capacity 400 KVA complete including foundation as per OEM recommendations | SITC of Voltage stabilizer for automatic operation, three phase naturally oil cooled Outdoor type of capacity 400 KVA complete including foundation as per OEM recommendations |
| 8 | Supply layingconnecting jointing and testing ductile iron pressure pipe of standrad length of K - 9 specification of size 500 mm dia bore including tyton joint complete | Supply layingconnecting jointing and testing ductile iron pressure pipe of standrad length of K - 9 specification of size 500 mm dia bore including tyton joint complete |
| 9 | S and F for Tee reducer sockets spigots caps pligs Bends Bell mouth or Tail pieces flange joints Y Junction Straight Tappers for spigot socket pipes size upto 500mm as required at site | S and F for Tee reducer sockets spigots caps pligs Bends Bell mouth or Tail pieces flange joints Y Junction Straight Tappers for spigot socket pipes size upto 500mm as required at site |
| 10 | Supply and fixing Non return Valve NRV of Size 500mm dia Cast Iron class PN - 1.6 heavy grade complete | Supply and fixing Non return Valve NRV of Size 500mm dia Cast Iron class PN - 1.6 heavy grade complete |
| 11 | SITC of 400 KVA outdoor type silent DG Set 415 Volts AC 3 Phase 4 wire system with builtin AMF Panel sound proof canopy and foundation etc as per OEM recommendations | SITC of 400 KVA outdoor type silent DG Set 415 Volts AC 3 Phase 4 wire system with builtin AMF Panel sound proof canopy and foundation etc as per OEM recommendations |
| 12 | SITC of 11 KV 630 Amps outdoor type 5 way RMU Ring Main Unit comprising of 02 Nos Load Break Switches and 03 Nos 630 Amp VCBs complete as per OEM recommendations | SITC of 11 KV 630 Amps outdoor type 5 way RMU Ring Main Unit comprising of 02 Nos Load Break Switches and 03 Nos 630 Amp VCBs complete as per OEM recommendations |
| 13 | SITC of 400 KVA cap 11 KV and 433 V AC 3 phase 50 Hz Outdoor type step down transformer double copper wound oil immersed ONAN vector group Dyn 11 and conforming to EEL - 3 as per IS - 1180 part - I | SITC of 400 KVA cap 11 KV and 433 V AC 3 phase 50 Hz Outdoor type step down transformer double copper wound oil immersed ONAN vector group Dyn 11 and conforming to EEL - 3 as per IS - 1180 part - I |
| 14 | M and L for construction of Platform for Transformer Galvanised chain link fencing 1 Mtr wide PCC along the fencing 1 Mtr wide Steel gate Gravels Danger notice plate all as per description | M and L for construction of Platform for Transformer Galvanised chain link fencing 1 Mtr wide PCC along the fencing 1 Mtr wide Steel gate Gravels Danger notice plate all as per description |
| 15 | M and L for earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick including galvanized iron earth strip 25 x 4 mm complete | M and L for earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick including galvanized iron earth strip 25 x 4 mm complete |
| 16 | SITC of LT Panel out door type CPRI approved out door type with 01 no incoming 630 Amp ACB and 2 no 630 amp outgoing MCCBs complete all as per description | SITC of LT Panel out door type CPRI approved out door type with 01 no incoming 630 Amp ACB and 2 no 630 amp outgoing MCCBs complete all as per description |
| 17 | Supply laying and testing of 11 KV HT XLPE insulated screened PVC bedded armoured electric power cable with aluminium conductor of sizes 3 Core 95 Sqmm complete all as per description | Supply laying and testing of 11 KV HT XLPE insulated screened PVC bedded armoured electric power cable with aluminium conductor of sizes 3 Core 95 Sqmm complete all as per description |
| 18 | S and F heat shrink type outdoor termination cable jointing kit for 11 KV 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as per description | S and F heat shrink type outdoor termination cable jointing kit for 11 KV 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as per description |
| 19 | S and F heat shrink type indoor termination cable jointing kit for 11 KV 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as per description | S and F heat shrink type indoor termination cable jointing kit for 11 KV 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as per description |
| 20 | Supply laying and testing 1100 volts grade XLPE insulated and PVC sheathed armoured multistrand aluminium conductors cable of size single core 630 sqmm complete all as per description | Supply laying and testing 1100 volts grade XLPE insulated and PVC sheathed armoured multistrand aluminium conductors cable of size single core 630 sqmm complete all as per description |
| 21 | Boring of hole under road or pavement or hard standing suitable for passing of GI or DWC pipe upto 150 mm bore and making good complete all as per description | Boring of hole under road or pavement or hard standing suitable for passing of GI or DWC pipe upto 150 mm bore and making good complete all as per description |
| 22 | S and F GI pipe 100mm bore steel tube light grade with all fittings complete all as per description | S and F GI pipe 100mm bore steel tube light grade with all fittings complete all as per description |
| 23 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for laying of cable etc and getting out in soft or loose soil complete all as per description | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for laying of cable etc and getting out in soft or loose soil complete all as per description |
| 24 | M and L for Sand cushioning 230 mm thickness with dry sand and punned down to 180 mm in trenches for protection of cable complete all as per description | M and L for Sand cushioning 230 mm thickness with dry sand and punned down to 180 mm in trenches for protection of cable complete all as per description |
| 25 | M and L for brick covering to underground electric cable using sub class B bricks complete all as per description | M and L for brick covering to underground electric cable using sub class B bricks complete all as per description |
| 26 | Supplying and laying un - reinfoced precast concrete cable cover of class HV type 1 with flat size 300 x 180 x 40 mm complete all as per description | Supplying and laying un - reinfoced precast concrete cable cover of class HV type 1 with flat size 300 x 180 x 40 mm complete all as per description |
| 27 | M and L for returning filling in approved excavated soil including spreading levelling and well ramming in layers n.exc 25 cm thick complete all as specified and directed | M and L for returning filling in approved excavated soil including spreading levelling and well ramming in layers n.exc 25 cm thick complete all as specified and directed |
| 28 | M and L for removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed | M and L for removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed |
| 29 | Supply and fixing in vertical position pre stressed concrete pole conforming to IS -1678 of 11 mtr long 152 mm x 152 mm at top and 152 mm x 260 mm at bottom class 9 complete all as per description | Supply and fixing in vertical position pre stressed concrete pole conforming to IS -1678 of 11 mtr long 152 mm x 152 mm at top and 152 mm x 260 mm at bottom class 9 complete all as per description |
| 30 | M and L for Cross Arms bracings supports clamps eye hook and back plates fabricated from structural steel sections complete all as per description | M and L for Cross Arms bracings supports clamps eye hook and back plates fabricated from structural steel sections complete all as per description |
| 31 | SITC gang operated air break switch mounted on insulators HT 11KV 200 Amps rating triple pole fifteen insulator suitable for vertical mounting complete all as per description | SITC gang operated air break switch mounted on insulators HT 11KV 200 Amps rating triple pole fifteen insulator suitable for vertical mounting complete all as per description |
| 32 | M and L for lightning arresters expulsion type complete with all fittings transmission class discharge capacity 65 Kilo Amps 11000 volts complete all as specified and directed | M and L for lightning arresters expulsion type complete with all fittings transmission class discharge capacity 65 Kilo Amps 11000 volts complete all as specified and directed |
| 33 | M and L for PCC 1 ratio 4 ratio 8 type D - 2 using 40 mm graded stone aggregate in mass concrete and filling complete for foundation complete all as specified and directed | M and L for PCC 1 ratio 4 ratio 8 type D - 2 using 40 mm graded stone aggregate in mass concrete and filling complete for foundation complete all as specified and directed |