| Sl. No. | Item Description |
| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8136/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: REPAIRS AND MAINT OF SUMMER AND WINTER APPLIANCES AT ARTY CENTRE, MH/MD AREA AND ASIF NAGAR AREA UNDER GE GOLCONDA. Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc. Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Water CoolersTaking out burnt / unserviceable compressor from existing water cooler compressor and S & F new sealed compressor unit including necessary welding/brazing/pressure testing with refrigerant after charging leak proof condition and testing complete for water cooler of capacity 40/60 ltrs. complete all as specified and as directed.Note:- Rate quoted shall be inclusive of R-22 refrigerant gas charging, testing and commissioning. Make : kirloskar/Shriram/Voltas/OEM |
| 3 | Taking out burnt / unserviceable compressor from existing water cooler and S & F new sealed compressor unit including necessary welding/brazing/pressure testing with refrigerant after charging leak proof condition and testing complete for water cooler of capacity 80/100 ltrs. complete all as specified and as directed.Note:- Rate quoted shall be inclusive of R-22 or R-134a Refrigerant gas charging, testing and commissioning. Make : kirloskar/Shriram/Voltas/OEM |
| 4 | S & F relay assembly and connecting with necessary wiring complete for water cooler of 40/60/120 ltrs capacity and taking down unserviceable one complete all as specified and as directed.Make:- Renutraul/Annapurna/Usha |
| 5 | S & Fix Over load protector complete suitable for Water cooler of capacity 40/60/150 Ltr including removal of old Unserviceable complete all as specified and as directed.Make – Renutraul/Annapurna/Usha |
| 6 | S & Fix starting capacitor of 60/80 MFD for water cooler all as directed and taking out the old unserviceable one. complete all as specified and as directed.Make- CONCAP /BHEL/TIBCON |
| 7 | S & Fix Thermostat set complete for Water cooler of any make/model/capacity including removing the old unserviceable Make – Danfoss / Renutraul/Annapurna |
| 8 | S & Fix capacitor of 6/10 MFD for water cooler all as directed and taking out the old unserviceable one complete all as specified and as directed.Make- CONCAP/ BHEL/TIBCON |
| 9 | S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for Water cooler capacity 40/80/120/150 ltrs and taking out the old unserviceable one complete all as specified and as directed. |
| 10 | Cleaning the gas system with CTC, rectification of leakages, M&L Charging gas with refrigerant gas including cutting/welding/brazing and leak testing with nitrogen, testing including commissioning complete for Water cooler 40 /60/150 ltrs capacity complete all as specified and as directed.Note :- Gas charging will be measured separately against relevant item of this schedule. |
| 11 | S & Fix Connecting lead PVC sheathed 3 core copper wire cable, 4 sq. mm 3 meter long with plug top 15 Amps for water cooler/Deep Freezer and taking out the old unserviceable one complete all as specified and as directed. |
| 12 | S & Fix PVC Float assembly to the water coolers including removing of the unserviceable from the existing position complete all as specified and as directed. |
| 13 | S & Fix Tap assembly to the water coolers of SS make including removing of the damaged unserviceable existing tap from the existing position complete all as specified and as directed. Make:JAISON or techno commercially equivalent make as listed in list of makes and as approved. |
| 14 | S & Fix Water cooler condenser suitable for 40/60 ltrs cooling capacity including necessary welding/brazing/pressure testing with Nitrogen Complete and taking out the old unserviceable one complete all as specified and as directed. |
| 15 | S & Fix Water cooler condenser suitable for 80/120 ltrs cooling capacity including necessary welding/brazing/pressure testing with Nitrogen Complete and taking out the old unserviceable one complete all as specified and as directed. |
| 16 | S & Fix PVC drain pipe 40 mm dia for water cooler complete all as directed and taking out the old unserviceable one complete all as specified and as directed. |
| 17 | RefrigeratorsTaking out burnt / unserviceable compressor from existing refrigerator and S & F new sealed compressor unit including necessary welding/brazing/pressure testing with Nitrogen after charging leak proof condition and testing complete for refrigerator of up to 310 ltrs capacity complete all as specified and as directed. Note:- Rate quoted shall be inclusive of R-134a refrigerant gas charging, testing and commissioning. Make : kirloskar/Shriram/Voltas/OEM |
| 18 | S & F relay assembly and connecting with necessary wiring complete for Refrigerator of 165/286 ltrs capacity and taking down unserviceable one complete all as specified and as directed. Make:- LG/Godrej /Whrilfool |
| 19 | All as per item No : 17 above but 310 ltrs capacity |
| 20 | S & Fix Thermostat set complete for Refrigerator of any make/model/capacity including removing the old unserviceable complete all as specified and as directed. Make – Danfoss / Renutraul/Annapurna |
| 21 | S & Fix Over load protector complete suitable for Refrigerator of any make/ model of165/280/310 Capacity including removal of old Un Serviceable complete all as specified and as directed.Make : Shriram /Renutraul / Voltas |
| 22 | S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for Refrigerators of capacity 280/310 ltrs and taking out the old unserviceable one. |
| 23 | Cleaning the gas system with CTC, rectification of leakages, M&L Charging gas with refrigerant gas including cutting/welding/brazing and leak testing with nitrogen, testing including commissioning complete for refrigerator 165 /310 ltrs capacity Note :- Gas charging will be measured separately against relevant item of this schedule. |
| 24 | S & Fix Connecting lead PVC sheathed 3 core copper wire cable, 4 sq. mm 3 meter long with plug top 15 Amps for water cooler/Deep Freezer and taking out the old unserviceable one. |
| 25 | S & Fix Magnetic door gasket for refrigerator of existing size and make including taking out the old gasket of refrigerator of capacity 165 / 286 / 310 ltrs. |
| 26 | S & Fix fan blade for Frost free motor of Refrigerator capacity 210/280/310 ltrs and taking out the old unserviceable one. |
| 27 | Removing burnt out fan motor of frost free Refrigerator/deep freezer motor and refixing with new one all as directed |
| 28 | Removing the burnt out Glass Heater of frost free refrigerator and fixing with new one all as directed. |
| 29 | S & Fix Refrigerator freezer box with door of capacity 165 Ltrs including necessary welding/brazing/pressure testing with Nitrogen of any make and taking out the old unserviceable one. |
| 30 | S & Fix Refrigerator freezer box with door of capacity 280 Ltrs including necessary welding/brazing/pressure testing with Nitrogen of any make and taking out the old unserviceable one. |
| 31 | S & Fix Refrigerator door handles suitable for any capacity and any make and taking out the old unserviceable one. |
| 32 | S & Fix Bi-metal fuse for refrigerator of any capacity and taking out the old unserviceable one. |
| 33 | S & Fix Refrigerator timer for frost free refrigerator of any capacity and taking out the old unserviceable one. |
| 34 | S & Fix Refrigerator condenser coil of 165 ltrs capacity including necessary welding/brazing/pressure testing with Nitrogen Complete and taking out the old unserviceable one. |
| 35 | S & Fix Refrigerator condenser coil of 310 ltrs capacity including necessary welding/brazing/pressure testing with Nitrogen and taking out the old unserviceable one. |
| 36 | S & Fix complete wiring kit for Refrigerator of any make/model of capacity 285/310 Ltrs with copper wire PVC insulated single core of size1.5 sq. mm,testing & complete all as directed. Note : any Accessories required for this job will be measured & paid separately and taking out the old unserviceable one. |
| 37 | Deep FreezersTaking out burnt / unserviceable compressor from existing Deep Freezer and S & F new sealed compressor unit including necessary welding/brazing/pressure testing with refrigerant after charging leak proof condition and testing complete for Deep freezers of any capacity. Note:- Rate quoted shall be inclusive of R-134a refrigerant gas charging, testing and commissioning.Make : Kirloskar/ Shriram/Voltas/Hitachi |
| 38 | S & Fix Over load protector complete suitable for Deep Freezer of any make/model of capacity 280/310 Ltrs including removal of old Un Serviceable Make : Shriram /Renutraul / Voltas |
| 39 | S & Fix Thermostat set complete for Deep Freezer of any make/model of capacity 280/310 Ltrs including removing the old unserviceable Make – Danfoss / Renutraul/Annapurna |
| 40 | S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for Deep Freezer and taking out the old unserviceable one. |
| 41 | Cleaning the gas system with CTC, rectification of leakages, M&L Charging gas with refrigerant gas including cutting/welding/brazing and leak testing with nitrogen, testing including commissioning complete for deep freezer 280/310 ltrs capacity Note :- Gas charging will be measured separately against relevant item of this schedule. |
| 42 | Desert CoolersS & Fix capacitor of 4/5 MFD for Desert Cooler all as directed and taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON |
| 43 | S & Fix Khas-khas screen(set of three) for desert coolers of any make and size and removing the old screen Complete. |
| 44 | S & Fix Fan blade of desert cooler Metallic/PVC as per existing model complete for desert coolers of any make complete for capacity 3000/4000 CUM and taking out the old unserviceable one. |
| 45 | S & Fix PVC water tube and distribution with 3 way PVC connection & bends assembly complete, for desert coolers of any make complete for capacity 3000/4000 CUM and taking out the old unserviceable one. |
| 46 | S & Fix Switch assembly as approved by the Engr-in-charge, for desert coolers of any make for capacity 3000/4000 CUM and taking out the old unserviceable one. |
| 47 | S & Fix in replacement of old unserviceable fan motor with new fan motors of desert coolers of 4000/5000 Cum capacity with nuts, bolts, brackets, connecting arrangements reconnecting including removing of the old U/S and testing complete all as directed. Make: OEM |
| 48 | S & Fix water circulating pump 1/7 HP, SP 1340 RPM having a head of 1.5 mtr suitable for desert cooler including nuts and bolts, washers brackets for fixing connecting with necessary wiring commissioning and testing and including taking down the old water circulating pump complete all as directed. Make-OEM |
| 49 | S & Fix Front grill / side grill of desert cooler suitable to existing one any make/model complete for capacity 3000/4000 CUM and taking out the old unserviceable one. |
| 50 | M&L for repairing of stabilizer of 1 KVA capacity including rewinding of Transformer, complete including replacement of PCBs, minor spare parts all as directed |
| 51 | Description all as per Item No-49 above but 4 KVA capacity for window /Split A/C 2.0 Ton complete all as directed. |
| 52 | Description all as per Item No-49 above but 5 KVA capacity for window /Split A/C 2.0 Ton complete all as directed. |
| 53 | Supply & charge refrigerant gas R-22 up to required level complete all as specified and directed. |
| 54 | Supply & charge refrigerant gas R-134a up to required level complete all as specified and directed. |
| 55 | S & Fix Sheet metal enclosure with single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps 'C' series, 230 Volts including removing of the old unserviceable. Make : STANDARD /INDOASIAN/C&S/OEM |
| 56 | S & Fix Plug top 3 Pin, 5 Amps 230 Volts including removing of the old unserviceable all as directed. Make : Anchor/Maru |
| 57 | All as per item No 55 here-in-before but 15 Amps. |
| 58 | S & Fix 3 pin industrial plug top suitable for industrial metal clad socket, single phase, 230 Volts, AC including MCB reconnecting complete all as directed and taking out the old unserviceable one. |
| 59 | Disconnecting and removing ceiling fan /wall mounting fan/exhaust fan from any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine & replacement of split pins, cotter pins and check nuts etc. overhauling, lubricating with approved lubricants, reassembling, including replacement of worn out/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including testing complete all as specified. NOTE :- (1) Necessary replacement of unserviceable parts/winding shall be measured and paid separately.(2)Labour element for replacing of unserviceable parts deemed to be included in rate quoted. |
| 60 | Supply only oil filled Capacitor, 2.5 mfd suitable for ceiling fan/ exhaust fan |
| 61 | Supply only oil filled Capacitor 4 mfd suitable for exhaust fan |
| 62 | Supply only Ball bearing suitable for ceiling fans /wall mounting fan/ exhaust fan including necessary greasing. Make: NBC/SKF/TATA |
| 63 | Supply only bushing suitable for ceiling fans /wall mounting fan/ exhaust fan |
| 64 | Supply only Rubber bush with clamp, nuts and bolts for ceiling fan |
| 65 | Supply only shaft made out of carbon steel including necessary lathe work for ceiling fan |
| 66 | S & fixing electronic ceiling fan regulator stepped type heavy duty suitable to work on 230 volts complete all as specified. Make : Bajaj/Havells/Crompton/Usha |
| 67 | S & Fixing Modular electronic ceiling fan regulator stepped type heavy duty suitable to work on 230 volts complete all as specified. |
| 68 | Taking out defective winding and rewinding of the ceiling fan of any sweep complete with equivalent new super enameled copper wire as per existing gauge and weight as per manufacturer's design and instructions including varnishing of ceiling fan of any make and any sweep complete all as specified and directed |
| 69 | All as per Item No.67 above but for exhaust fan of 225 to 305mm sweep |
| 70 | All as per Item No.67 above but for exhaust fan of 330 to 400mm sweep |
| 71 | All as per Item No.67 above but for exhaust fan of 450mm sweep |
| 72 | All as per Item No.67 above but for air circulator fan of any sweep |
| 73 | M & L for spray painting the Ceiling Fan/wall mounting fan and accessories of any make / model / sweep with one coat of synthetic enamel DUCO paint (white colour) complete all as specified and directed. |
| 74 | M & L for spray painting the Exhaust Fan/air circulator fan and accessories of any make / mode/sweep with one coat of synthetic enamel paint (smoke gray colour) complete all as specified and directed. |
| 75 | Taking down carefully old burnt/unserviceable compressor unit of 1.0 ton capacity window type/Split type AC and replacing the same with New compressor including necessary accessories and mounting materials, welding, brazing, leak testing, vaccumissing and charging the refrigerant gas to the required pressure and weight, reinstalling the AC unit on the same place including testing and commissioning complete to any make of AC all as directed. Note:- Rate quoted shall be inclusive of R-22 refrigerant gas charging, testing and commissioning.Make : Kirloskar / Voltas/ LG/OEM |
| 76 | All as per item No : 74 above but for Window/Split type AC 1.50 Ton Capacity |
| 77 | All as per item No : 74 above but for Window/Split type AC 2.00 Ton Capacity |
| 78 | S & Fix Relay assembly and connecting with necessary wiring complete suitable for Window/Split type of AC 1.0/1.5/2.0 Ton Capacity and taking out the old unserviceable one. Make : Shriram /Renutraul / Voltas |
| 79 | S & Fix Over load protector complete suitable for Window/Split type AC of 1.0/105/2.0 Ton Capacity including removal of old Un Serviceable :-Make : Shriram /Renutraul / Voltas |
| 80 | S & Fix Thermostat set complete for window/split type AC of any make/model of Capacity 1.0/1.5/2.0 Ton including removing the old unserviceable Make – Renutraul/Annapurna/Usha |
| 81 | S & Fix Blower fan motor, with fixing arrangement complete operating on 215 / 240 Volts, single phase AC supply, multi speed suitable for Window AC 1/1.5/2.0 Ton capacity including taking out the old one. Make : OEM |
| 82 | Rewinding of outdoor fan motor with same gauge and turns and weight of copper enameled wire and replacement of bearing, testing and commissioning of 1.0/1.5/2.0 Ton split type AC of any make/ model complete all as directed. |
| 83 | S & Fix capacitor of 36/45 MFD for Window/Split type AC's all as directed and taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON |
| 84 | S & Fix capacitor of 50/60 MFD for Window/Split type AC's all as directed and taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON |
| 85 | S & Fix Selector switch normal/Rotary complete for window type A/C 1 to 2 Ton capacity suitable for push button type including taking down the unserviceable one |
| 86 | S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for window /Split type AC 1 Ton to 2 Ton capacity and taking out the old unserviceable one. |
| 87 | S & Fix Wiring kit for window type AC of 1.0/1.5/2.0 Ton capacity with copper wire PVC insulated single core of size1.5 sq. mm, clips, terminal connector etc. complete all as directed and taking out the old unserviceable one. |
| 88 | Description same as per item No : 86 above but Split type AC of capacity 1.0/1.5/2.0 ton . |
| 89 | Cleaning the unit with CTC except evaporator and condenser and leak testing the system with Nitrogen gas and detecting the leak and repairing, brazing and sealing the leakage including charging the refrigerant R-22 gas to the required pressure and weight of gas for 1.0/1.5/2.0 Ton capacity window type ACof any make complete all as directed Note :- Gas charging will be measured separately against relevant item of this schedule. |
| 90 | Description same as per item No : 88 above but Split type AC of capacity 1.0/1.5/2.0 ton . |
| 91 | Servicing to the split type AC units of 1/1.5/2.0 ton capacity, cleaning of the evaporator coils externally with Caustic Soda / Chemical to remove the dust particles deposited on the cooling coil, cleaning of the condensing units to reduce the discharge pressure with the Caustic Soda / Chemical and testing complete all as directed. |
| 92 | Servicing to the window type Air Conditioners of capacity 1/1.5/2.0 ton capacity, cleaning of the evaporator coil externally with Caustic Soda / chemical to remove the dust particles, cleaning of the filters and testing complete all as directed. |
| 93 | S & Fix Air Filter to the window /Split type Air Conditioners of 1/1.5 /2.0 Ton capacity and taking out the old unserviceable one. |
| 94 | S & Fix Evaporator coil, including connected brazing welding work and provision of refrigerant suction/discharge line suitable for Window Ac / Split Type Ac 1.0/1.5 / 2.0 TR capacity including removing the unserviceable evaporator coil from the existing position all as directed. |
| 95 | S & Fix new remote control assembly for split type AC 1.5 /2.0 TR capacity including removing of the old unserviceable complete all as directed. |
| 96 | Taking out the unserviceable condenser coil and S & F new condenser coil made out of 25 SWG copper tubing having 30/34G aluminium fins per CM length for window AC/Split type AC 's of 1.5 Ton capacity all as directed including taking down old U/S condenser coil. |
| 97 | S & Fix Front grill for Window AC as existing make/model and taking out the old unserviceable one. |
| 98 | S & Fix indoor blower motor for split type AC of capacity 1.5/2.0 Ton as per existing model complete all as directed and taking out the old unserviceable one. Make : OEM |
| 99 | S & Fix PVC drain pipe 25 mm for rectifying water leakage from AC units complete all as directed and taking out the old unserviceable one. |
| 100 | S & Fix copper tube of size 3/8, 5/8 inch dia including necessary soldering , flooring and connecting and testing in between indoor to out door units of split type AC 1.5/2.0 Ton complete all as directed and taking out the old unserviceable one. |
| 101 | Description all as per Item No-99 above but size of copper tubing 1/2, 1/4 inch dia complete all as directed. |
| 102 | S & Fix insulation felt for split type AC 1.5 / 2.0 Ton copper tube inlet/outlet to out door unit up to 3 mtr in length complete all as directed. |
| 103 | Taking out unserviceable 1 Pole contactor from split AC and replacing the same with new contactor suitable for 240V,50Hz coil complete all as directed and taking out the old unserviceable one. |
| 104 | S & Fix Oscillation motor for the indoor unit of the split type AC of 1.5/2.0 Ton capacity complete all as directed and taking out the old unserviceable one. |
| 105 | Taking out unserviceable dummy nuts from the split AC units and S & Fix new Brass Dummy / Flare nuts of existing size complete all as directed and taking out the old unserviceable one. |
| 106 | S & Fix Fan blade for 1.5/2 Ton capacity window/Split type ACs as per existing size/ model complete all as directed and taking out the old unserviceable one. |
| 107 | Taking down unserviceable Indoor unit of Split type AC of 1.5 TR capacity any make, model and S & F new indoor unit of same capacity suitable to existing Outdoor Unit including the necessary connections and testing complete all as directed. Make : OEM |
| 108 | Repairs to PCB of split type AC 1.5 /2.0 TR capacity including of replacement of electronic spares complete all as directed. |
| 109 | Taking down water heater (Electric Geyser) of any type /make of 25/50 Ltrs capacity after disconnecting the existing electric wire , water pipe , inspecting the inner tank and components for necessary repairs including cleaning and removal of scales etc. servicing etc. and re-assembling in all respects after replacing unserviceable parts/components and testing for proper working after repairs and fixing in the original place/ position duly connecting up water supply and electric supply complete including civil work for grouting etc. all as specified and directed. NOTE:- (i) Necessary repairs /replacement parts shall be measured and paid separately .(ii) Labour for replacing of unserviceable spare parts deemed to be included in rate quoted. |
| 110 | Supply & fix chromium plated connecting pipe with two brass adopters and brass flexible tubing for Hot water pipe connection for geyser |
| 111 | Supply and fixing in repair PVC cold water connection pipe 60 cms long 15 mm dia for Hot water apparatus (Geyser 25 / 50 Ltrs Capacity) and as directed |
| 112 | Supply & fix non return valve 15/20mm dia for cold water connection of geyser |
| 113 | Supply & fix Pressure release valve suitable for 25 Ltrs capacity Geyser complete all as specified. |
| 114 | All as per item No.112 above but 50 Liters capacity |
| 115 | Supply & fix thermostat including rubber gasket for 25 litres capacity geyser |
| 116 | All as per item No.114 above but 50 Liters capacity |
| 117 | Supply & fix Indicator bulb neon AC 230 Volts (Round/Square) |
| 118 | Supply & fix Heating Element 1500 Watts including rubber/ PVC gasket of push type/threaded /round /triangle base type (as per sample) |
| 119 | Supply & fix Heating Element 2000 Watts including rubber/ PVC gasket of push type/threaded /round /triangle base type (as per sample) |
| 120 | Supply only Apparatus plate base assembly complete with drain plug and fixing element including clamps for geyser of 50 lit capacity |
| 121 | Supply only Apparatus plate base assembly complete with drain plug and fixing element including clamps for geyser of 25 lit capacity |
| 122 | Supply only for replacement of insulating material ( Glass wool 'A' class) for geyser of 25 lit capacity all as directed. |
| 123 | Supply only for replacement of insulating material ( Glass wool 'A' class) for geyser of 50 lit capacity all as directed. |
| 124 | S & F GI tubing medium grade 15mm bore with all fittings fixed to wall / laid in floor and including making good the disturbed surface to match with the existing surface including dismantling existing air released valve pipe and making proper connection for hot air releasing system complete all as specified. |
| 125 | S & F GI tubing medium grade 20mm bore with all fittings fixed to wall / laid in floor and including making good the disturbed surface to match with the existing surface including dismantling existing air released valve pipe and making proper connection for hot air releasing system complete all as specified. |
| 126 | S&F in repairs bib tap 15 mm bore dia, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 127 | S&F in replacement of 15A 3 pin plug top polycarbonate, AC, 240V all specified and directed. |
| 128 | Supply only Fan blades suitable for existing ceiling fans. |
| 129 | M&L fabricated of mild steel iron bands, straps, supports or stays for rain water ,ventilating pipes including bolts if required hooks(stay) heavy for large gates ,hook and pintle hinges, large hasps and staples ,chains, hand made sliding's bolts clamps hold fasts, wall ties hook for hanging fans, plain angles cleats for securing purlins to wood trusses or rafters ,knee piece inserts two way and three way straps plate washers and similar small articles conforming to Fe 290 Gde E-165, including clamps nuts,bold,fixing and old one complete all as specified and directed. |
| 130 | M&L fabricated ceiling fans down rod both side hole and fixing clamps arrangement size of 15mm heavy duty GI pipe of one feet including taking down old one and fixing complete all as specified and directed. |
| 131 | M&L fabricated ceiling fans down rod both side hole and fixing clamps arrangement size of 15mm heavy duty GI pipe of two feet including taking down old one and fixing complete all as specified and directed. |
| 132 | M&L fabricated ceiling fans down rod both side hole and fixing clamps arrangement size of 15mm heavy duty GI pipe of three feet including taking down old one and fixing complete all as specified and directed. |
| 133 | Supply and fix desert cooler (PVC body) electric driven single phase, having nominal air flow capacity of 6000 CUM per hour aluminium fan blade, copper winding fan motor, submersible pump of make khaitan Zolta (ISI marked) with float valve of 15mm dia Make : Khaithan/Crompton/Usha/Bajaj |
| 134 | Supply & fix Wall mounted fans AC single phase 230/ 240 V, of size 400 mm sweep, metal body, three blade with fixing arrangement including making of hole to the wall and making good the disturbed surface complete. Make : Bajaj/Havells/Crompton/Usha |
| 135 | Maintenance/Servicing, Cleaning, Descaling of solar water heating system of capacity 200 Ltr per day having 02 Nos of collector , 01 No of steel tank and 01 No of plastic make up tank 500 Ltr by replacement of washers, gasket, adaptor and worn out nut bolt ,GI fitting for water pipe line 20/25 mm for inlet and outlet of steel tank/collector /water make up tank and making fully leak proof all as specified and directed |
| 136 | S&F in repairs Hot water storage tank of cap 200 LPD made out of Stainless steel 304 grade having 1.5 mm thickness insulated with 100 mm puff insulation ( insulating material rockwool of 48 kg/cum density and covered with precoated sheet and other necessary connected items complete all as specified and directed |
| 137 | S&F in replacement flange threaded type suitable for 20/25mm dia hot water pipe for solar hot water system all as specified |
| 138 | S&F in replacement black hose pipe suitable for 20/25mm dia hot/cold water pipe for solar hot water system all as specified |
| 139 | M & L Submain wiring on surface with 2 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metallic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed. Note:-Two runs of cable, one run of earth continuity conductor and one run of conduit shall be measured as one unit length. |
| 140 | M & L Submain wiring on surface with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metallic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed. Note:-Two runs of cable, one run of earth continuity conductor and one run of conduit shall be measured as one unit length. |
| 141 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed |
| 142 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed |
| 143 | Supply and fix AC contactor 32 Amps, 3 phase ,415 volts, 50 Hz suitable for cold storage all as specified and directed |
| 144 | Supply and fix vent cover of existing size of exhaust fans complete and all as specified and directed |
| 145 | Supply and fix in repair outer cover body with Top and bottom cover made of MS Sheet of suitable thickness duly painted of white colour suitable for geyser of 25 ltr cap of any make complete all as specified and as directed. |
| 146 | Supply and fix in repair stainless steel inner tank suitable for geyser of 25 ltr cap of any make complete all as specified and as directed. |
| 147 | Supply and fix in repair stainless steel inner tank suitable for geyser of 50 ltr cap of any make complete all as specified and as directed. |
| 148 | Supply and fix in repair PVC hot water connection pipe 90 cms long 15 mm dia for Hot water apparatus (Geyser 25 / 50 Ltrs Capacity) and as directed |
| 149 | M&L for mild steel structural steel including nuts, bolts and washers including welding, bending, cold or hot drilling holes for bolts in any shape or size as directed inclusive of one coat of primer and two coats of black paint including removing the existing unserviceable one all as directed. |
| 150 | Supply and Fix stainless steel water tap suitable for existing water cooler capacity all as directed. |
| 151 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 3 Core ,2.5 Sq. mm 1100 Volts grade all as directed. |
| 152 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 3 Core ,4 Sq. mm 1100 Volts grade all as directed. |
| 153 | Supply and fix out door unit fan motor with blade water proof type suitable for cold storage unit all as specified and directed |
| 154 | M & L for providing point wiring with 3 runs of 1.5 sq. mm single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable, 1100 volts grade in and including non metallic rigid PVC conduit medium grade with appropriate size with all fittings concealed in wall including modular sunken box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators etc. complete for :-(a) one ceiling fan controlled by one switch & regulator. |
| 155 | (b) All as per item No. 153 but one exhaust fan controlled by one switch. |
| 156 | (c) All as per item No. 153 but one 3 pin socket 6 Amp on independent board. |
| 157 | (d) All as per item No. 153 but one 3 pin socket 6 Amp on same board. |
| 158 | All as per item No. 153 but for One 3 pin 15 Amps switch socket outlet point on independent board with 4.0 sqmm PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable all as specified and directed. |
| 159 | Supply and fix Modular switch, single pole, one way, 6 Amps one module complete. |
| 160 | Supply and fix Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and directed. |
| 161 | Supply and fix Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed. |
| 162 | Supply and fix Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed. |
| 163 | Supply and fix Ceiling rose surface bakelite three terminal / PVC / Polycarbonate / isolated body 65x50 mm, terminals 240 volts complete, all as specified and directed. |
| 164 | Supply and fixing 1.5sqmm copper wire single core with complete all as specified and directed at site. |
| 165 | Supply and fixing 2.5sqmm copper wire single core with complete all as specified and directed at site. |
| 166 | Maintenance / Repairs to Analog/ Digital Energy Meters of current coil, Potential Coil, Alu Disk, terminals, change of Display and magnets with complete all as specified and directed |
| 167 | M & L for Submain wiring on surface with 2 runs of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metallic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 4sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed. Note:-Two runs of cable, one run of earth continuity conductor and one run of conduit shall be measured as one unit length. Notes for all items :- The retrieved materials have been mentioned in the Schedule of credit in the tender documents in pdf form. The amount of Sch of credit will be deducted offline from the amount of BOQ at the time of acceptance.(i) AC Mechanic /electrician should note down complaints from Complaint Register or Instruction by JE / Phone and complaints shall be attended at various locations under GE Golconda areas which are 5 kms from complaint cell & complaint should be completed within 4 days. Major/Compressor replacement complaints with in 6 days. (ii) Old unserviceable compressors/motors will be handed over to contractor at the end of the Contract period by deshaping/ cutting them.(iii) AC Mechanic/electrician duties as measured in note (i) is deemed to be included in CA items. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail